Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suvicha Sasivimolkul has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Phitsini Suvarnaphaet

    College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand

    2 shared publications
  • Suejit Pechprasarn

    College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand

    2 shared publications
  • Chayanisa Sukkasem

    College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand

    1 shared publication
  • Michael G. Somekh

    Nanophotonics Research Center, Shenzhen Key Laboratory for Micro-Scale Optical Information Technology & Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China, and Faculty of Engineering, University of Nottingham, Nottingham, NG7 2RD, UK

    1 shared publication
  • Suejit Pechprasarn

    College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand, and Nanophotonics Research Center, Shenzhen Key Laboratory for Micro-Scale Optical Information Technology & Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China

    1 shared publication

Latest Publications

  • Open Access

    Fabry–Perot Resonance in 2D Dielectric Grating for Figure of Merit Enhancement in Refractive Index Sensing

    by Suejit Pechprasarn, Suvicha Sasivimolkul, Phitsini Suvarnaphaet

    We have recently reported in our previous work that one-dimensional dielectric grating can provide an open structure for Fabry–Perot mode excitation. The grating gaps allow the sample refractive index to fill up the grating spaces enabling the sample to perturb the Fabry–Perot mode resonant condition. Thus, the grating structure can be utilized as a refractive index sensor and provides convenient sample access from the open end of the grating with an enhanced figure of merit compared to the other thin-film technologies. Here, we demonstrate that 2D grating structures, such as rectangular pillars and circular pillars, can further enhance refractive index sensing performance. The refractive index theory for rectangular pillars and circular pillars are proposed and validated with rigorous coupled wave theory. An effective refractive index theory is proposed to simplify the 2D grating computation and accurately predict the Fabry–Perot mode positions. The 2D gratings have more grating space leading to a higher resonant condition perturbation and sensitivity. They also provide narrower Fabry–Perot mode reflectance dips leading to a 4.5 times figure of merit enhancement than the Fabry–Perot modes excited in the 1D grating. The performance comparison for thin-film technologies for refractive index sensing is also presented and discussed.


  • Open Access

    Analysis of Embedded Optical Interferometry in Transparent Elastic Grating for Optical Detection of Ultrasonic Waves

    by Chayanisa Sukkasem, Suvicha Sasivimolkul, Phitsini Suvarnaphaet, Suejit Pechprasarn

    In this paper, we propose a theoretical framework to explain how the transparent elastic grating structure can be employed to enhance the mechanical and optical properties for ultrasonic detection. Incident ultrasonic waves can compress the flexible material, where the change in thickness of the elastic film can be measured through an optical interferometer. Herein, the polydimethylsiloxane (PDMS) was employed in the design of a thin film grating pattern. The PDMS grating with the grating period shorter than the ultrasound wavelength allowed the ultrasound to be coupled into surface acoustic wave (SAW) mode. The grating gaps provided spaces for the PDMS grating to be compressed when the ultrasound illuminated on it. This grating pattern can provide an embedded thin film based optical interferometer through Fabry–Perot resonant modes. Several optical thin film-based technologies for ultrasonic detection were compared. The proposed elastic grating gave rise to higher sensitivity to ultrasonic detection than a surface plasmon resonance-based sensor, a uniform PDMS thin film, a PDMS sensor with shearing interference, and a conventional Fabry–Perot-based sensor. The PDMS grating achieved the enhancement of sensitivity up to 1.3 × 10−5 Pa−1 and figure of merit of 1.4 × 10−5 Pa−1 which were higher than those of conventional Fabry–Perot structure by 7 times and 4 times, respectively.


  • Open Access

    Analysis of Open Grating-Based Fabry–Pérot Resonance Structures With Potential Applications for Ultrasensitive Refractive Index Sensing

    by Suvicha Sasivimolkul, Suejit Pechprasarn, Michael G. Somekh

    We report a theoretical framework to explain the characteristics of Fabry-Pérot (FP) resonances excited in a thin film-based grating consisting of a thin gold layer and a rectangular dielectric grating in the sub-wavelength and near-wavelength grating regimes. The zeroth-order diffraction inside the grating layer forms an FP resonant cavity with effective refractive index arising from an averaging effect between the refractive indices of the grating material and the filling material between the grating grooves. A simplified model based on Fresnel equations and phase matching condition is proposed to predict the FP resonant mode for the grating structure, this is compared with rigorous coupled-wave analysis to determine its range of validity. We also compare the performance of the proposed structure with other thin film-based interferometers for refractive index sensing applications, in terms of, sensitivity, full width at half maximum, figure of merit and dynamic range. The proposed structure has a full width at half maximum around 10 times to 60 times narrower than conventional surface plasmon resonance and conventional FP resonators. Thus, the figure of merit is higher than Kretschmann based surface plasmon resonance and FP structures by a factor of 20 and 2 respectively with a wider dynamic range. The total energy stored in the grating resonant cavity is 5 and 20-fold greater than the surface plasmon resonance configuration and the conventional FP structures. Since the resonator discussed here is an open structure, it is far better suited for liquid sensing compared to a closed FP structure.