Roman Ozhohan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roman Ozhohan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Zinovii Ozhogan
Івано-Франківський національний медичний університет
3 shared publications - Ihor Viklyuk
Ivano-Frankivsk National Medical University, Ivano-Frankivsk, Ukraine
2 shared publications - Mykola Kirilyuk
Івано-Франківський національний медичний університет, кафедра ортопедичної стоматології, м. Івано-Франківськ, Україна
2 shared publications - I. V. Yanishen
Kharkiv National Medical University of the Ministry of Health of Ukraine, Kharkiv, Ukraine
1 shared publication - I.R. Kumhyr
Ivano-Frankivsk National Medical University of the Ministry of Health of Ukraine, Ivano-Frankivsk, Ukraine
1 shared publication - L.V. Miziuk
Ivano-Frankivsk National Medical University of the Ministry of Health of Ukraine, Ivano-Frankivsk, Ukraine
1 shared publication
Latest Publications
- Open Access
- 3 July 2026
- Published by Poltava State Medical University (PSMU) in Ukrainian Dental Almanac
- No. 2,p. 56-61
PSYCHOSOCIAL STATUS AND OCCLUSAL SUPPORT IN PATIENTS WITH MUSCLE AND DISC TEMPOROMANDIBULAR DISORDERS
Background. The relationship between occlusal disorders, psychosocial status, and various clinical forms of temporomandibular disorders (TMDs) remains a subject of scientific debate. This study aims to identify and analyze the specific characteristics of the disease course in patients with muscle and disc disorders. Objective. To study and compare the indicators of psychoemotional status (PHQ-9, GAD-7), functional limitations (JFLS-8), and occlusal support (Eichner index) in adult patients with muscle and disc forms of TMDs. Methods. 71 patients with a verified diagnosis of TMD according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) were examined. The participants were divided into two groups: group 1 (n=37) – patients with muscle disorders, and group 2 (n=34) – patients with disc disorders (predominantly disc displacement with reduction). Psychosocial status was assessed using the PHQ-9 and GAD-7 scales, functional limitations using the JFLS-8, and dentition status using the Eichner index. Results. Patients with muscle disorders were significantly older (42.0 ± 7.7 years) and demonstrated significantly higher levels of depression (7.95 ± 3.13) and anxiety (7.11 ± 2.78) compared to the disc disorders group (p < 0.001). In the disc disorders group, 79.4% of patients had preserved dentition (Eichner class A), whereas in the muscle disorders group, more than half of the patients (51.4%) had partial loss of occlusal support zones (class B). No statistically significant difference in the JFLS-8 functional limitation scale was found between the groups (p = 0.066). Conclusions. The loss of occlusal support is closely associated with myogenic disorders; however, this association may be partially mediated by the older age of patients in this group. Meanwhile, disc disorders more frequently develop in the presence of preserved dentition. Patients with muscle pain are characterized by higher levels of comorbid anxiety and depression, which requires a comprehensive diagnostic approach. These findings underscore the need for differentiated treatment planning for various TMD subtypes.
- 3 July 2026
- Published by Poltava State Medical University (PSMU) in Ukrainian Dental Almanac
- No. 2,p. 56-61
Open AccessPSYCHOSOCIAL STATUS AND OCCLUSAL SUPPORT IN PATIENTS WITH MUSCLE AND DISC TEMPOROMANDIBULAR DISORDERS
Background. The relationship between occlusal disorders, psychosocial status, and various clinical forms of temporomandibular disorders (TMDs) remains a subject of scientific debate. This study aims to identify and analyze the specific characteristics of the disease course in patients with muscle and disc disorders. Objective. To study and compare the indicators of psychoemotional status (PHQ-9, GAD-7), functional limitations (JFLS-8), and occlusal support (Eichner index) in adult patients with muscle and disc forms of TMDs. Methods. 71 patients with a verified diagnosis of TMD according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) were examined. The participants were divided into two groups: group 1 (n=37) – patients with muscle disorders, and group 2 (n=34) – patients with disc disorders (predominantly disc displacement with reduction). Psychosocial status was assessed using the PHQ-9 and GAD-7 scales, functional limitations using the JFLS-8, and dentition status using the Eichner index. Results. Patients with muscle disorders were significantly older (42.0 ± 7.7 years) and demonstrated significantly higher levels of depression (7.95 ± 3.13) and anxiety (7.11 ± 2.78) compared to the disc disorders group (p < 0.001). In the disc disorders group, 79.4% of patients had preserved dentition (Eichner class A), whereas in the muscle disorders group, more than half of the patients (51.4%) had partial loss of occlusal support zones (class B). No statistically significant difference in the JFLS-8 functional limitation scale was found between the groups (p = 0.066). Conclusions. The loss of occlusal support is closely associated with myogenic disorders; however, this association may be partially mediated by the older age of patients in this group. Meanwhile, disc disorders more frequently develop in the presence of preserved dentition. Patients with muscle pain are characterized by higher levels of comorbid anxiety and depression, which requires a comprehensive diagnostic approach. These findings underscore the need for differentiated treatment planning for various TMD subtypes.
- Open Access
- 3 April 2026
- Published by Poltava State Medical University (PSMU) in Ukrainian Dental Almanac
- No. 1,p. 53-60
EFFECT OF THE OPTIGLAZE PROTECTIVE COATING ON THE ADHESION OF ORAL MICROORGANISMS TO DENTURE BASE MATERIALS
To reduce microbial adhesion and improve the antimicrobial properties of dental materials, surface-modification strategies have been proposed, including mechanical polishing, bioactive chemical coatings, nanocomposite surface treatment, and advanced CAD/CAM technologies. The aim of this study was to compare the adhesion of a broad spectrum of bacteria and fungi of the oral microflora to acrylic and elastic denture base plastics coated with Optiglaze, as a measure to prevent biofilm formation. Materials and Methods. The study used specimens 2 mm thick and 1 cm² in area, fabricated from the acrylic denture base resin Villacryl (40 specimens) and the elastic resin Acron (40 specimens), as well as a control material—glass (40 specimens). After sandblasting, a thin layer of Optiglaze (GC Corp., Japan) was applied to all surfaces of each specimen in three groups (40 specimens per group), polymerized with an LED curing light, and sterilized by X-ray irradiation. The study employed strains of opportunistic microorganisms representing facultative anaerobic transient microflora of the oral cavity. Microbial adhesive capacity was assessed in an in vitro experiment using a modified Lassila L. method, which involves ultrasonic elution of cells attached to the surface followed by counting colony-forming units (CFU). Results. Optiglaze significantly reduced microbial adhesion on Villacryl and glass. Exceptions included S. epidermidis and P. aeruginosa, for which no reduction was observed, and C. lipolytica, for which the reduction was partial. Two-way ANOVA for each strain demonstrated significant main effects of both material type and Optiglaze coating for most microorganisms. A significant material × coating interaction was observed for S. aureus (MSSA and MRSA), S. gordonii, E. coli, A. baumannii, C. albicans, and C. lipolytica, indicating that the effect of Optiglaze depends on the base material. Overall, Optiglaze significantly decreased adhesion on all tested materials, with the strongest effect observed on Villacryl (Holm p = 3.99 × 10⁻¹⁰; BH p = 3.99 × 10⁻¹⁰), and a moderate effect on Acron (Holm p = 2.41 × 10⁻⁶; BH p = 1.81 × 10⁻⁶) and glass (Holm/BH p = 1.63 × 10⁻⁵). Conclusion. The type of denture base material and the presence of the Optiglaze coating significantly affect the adhesion of oral microbial strains to the surface of experimental specimens. The Optiglaze protective coating reduces microbial adhesion on all three materials: most pronounced on glass (almost all strains showed significant differences), and moderate on Villacryl and Acron.
- 3 April 2026
- Published by Poltava State Medical University (PSMU) in Ukrainian Dental Almanac
- No. 1,p. 53-60
Open AccessEFFECT OF THE OPTIGLAZE PROTECTIVE COATING ON THE ADHESION OF ORAL MICROORGANISMS TO DENTURE BASE MATERIALS
To reduce microbial adhesion and improve the antimicrobial properties of dental materials, surface-modification strategies have been proposed, including mechanical polishing, bioactive chemical coatings, nanocomposite surface treatment, and advanced CAD/CAM technologies. The aim of this study was to compare the adhesion of a broad spectrum of bacteria and fungi of the oral microflora to acrylic and elastic denture base plastics coated with Optiglaze, as a measure to prevent biofilm formation. Materials and Methods. The study used specimens 2 mm thick and 1 cm² in area, fabricated from the acrylic denture base resin Villacryl (40 specimens) and the elastic resin Acron (40 specimens), as well as a control material—glass (40 specimens). After sandblasting, a thin layer of Optiglaze (GC Corp., Japan) was applied to all surfaces of each specimen in three groups (40 specimens per group), polymerized with an LED curing light, and sterilized by X-ray irradiation. The study employed strains of opportunistic microorganisms representing facultative anaerobic transient microflora of the oral cavity. Microbial adhesive capacity was assessed in an in vitro experiment using a modified Lassila L. method, which involves ultrasonic elution of cells attached to the surface followed by counting colony-forming units (CFU). Results. Optiglaze significantly reduced microbial adhesion on Villacryl and glass. Exceptions included S. epidermidis and P. aeruginosa, for which no reduction was observed, and C. lipolytica, for which the reduction was partial. Two-way ANOVA for each strain demonstrated significant main effects of both material type and Optiglaze coating for most microorganisms. A significant material × coating interaction was observed for S. aureus (MSSA and MRSA), S. gordonii, E. coli, A. baumannii, C. albicans, and C. lipolytica, indicating that the effect of Optiglaze depends on the base material. Overall, Optiglaze significantly decreased adhesion on all tested materials, with the strongest effect observed on Villacryl (Holm p = 3.99 × 10⁻¹⁰; BH p = 3.99 × 10⁻¹⁰), and a moderate effect on Acron (Holm p = 2.41 × 10⁻⁶; BH p = 1.81 × 10⁻⁶) and glass (Holm/BH p = 1.63 × 10⁻⁵). Conclusion. The type of denture base material and the presence of the Optiglaze coating significantly affect the adhesion of oral microbial strains to the surface of experimental specimens. The Optiglaze protective coating reduces microbial adhesion on all three materials: most pronounced on glass (almost all strains showed significant differences), and moderate on Villacryl and Acron.
- Open Access
- 30 December 2024
- Published by Ivano-Frankivsk National Medical University in Archive of Clinical Medicine
- Vol. 30 (2) , 75-78
The Method of Splinting Mobile Teeth in the Presence of Small Defects of the Dentitions with Aesthetic Polymer Adhesive Splinting Prosthesis
To the presence healthy teeth is an integral part of human health. Their partial or complete loss can have complex consequences for our functioning and quality of life. There are a number of factors that lead to tooth loss. In particular, genetic factors, periodontal diseases, caries complications, poor diet and bad habits. In some cases, tooth loss can be hereditary, caused by an increased tendency to develop caries or periodontal diseases. The presence of various abnormalities in the development of teeth can also be the reason for their loss in the future. Furthermore, the most common methods of treating partial defects of the dentition combined with periodontal tissue diseases are fixed partial and adhesive metal-ceramic prostheses, the design of which involves significant preparation of the hard tissues of the teeth that limit the defect. An adhesive metal-ceramic prosthesis, the design of which consists of an artificial tooth and fixing elements made in the form of cores or overlays, completely covered with ceramic material, has a number of disadvantages and limited indications for use. For the proposed adhesive splint prosthesis allows minimally dissection of supporting teeth hard tissues; at the expense of high accuracy production maybe to be used for minor deformations of the dentition, if present carious and non-carious lesions; due to high bioinertness recommended construction of choice for periodontal tissue diseases. The purpose of the study. To increase the effectiveness of orthopedic treatment of patients with chronic periodontitis of moderate severity and to substantiate the method of splinting mobile teeth in the presence of small dentition defects in the frontal area, taking into account the anatomical features, functionality and aesthetic appearance of the structure. Materials and methods. With the help of adhesive splint prosthesis are made of high-tech polymer PEEK-"Bio Hpp" proposed a new approach to the problem of treating small dentition defects in the frontal area. A comparative analysis was conducted and the advantages of the proposed design with similar prostheses were proven. Research results. The obtained results indicate that the proposed design allows for splinting and restoration of the aesthetic appearance and integrity of the dentition, preventing the occurrence of deformations and ensuring the functionality of the maxillofacial system. Conclusions 1. The proposed design of the adhesive splint prosthesis made of high-tech polymer PEEK-"Bio Hpp" allows you to restore the integrity of the dentitions in the presence of small included defects in the frontal area and provides a good splinting result. 2. Production of a frame from high-tech polymer PEEK-"Bio Hpp”, allows to significantly reduce the depth of preparation of teeth hard tissues, providing an excellent aesthetic result, which makes it possible to significantly expand the indications for use. 3. The long-term results of the treatment indicate the absence of marginal staining at the border of the hard tissue of the tooth - indirect restoration, i.e. marginal detachment, which provides good aesthetics, functional integrity of the structure and a satisfactory splinting result.
- 30 December 2024
- Published by Ivano-Frankivsk National Medical University in Archive of Clinical Medicine
- Vol. 30 (2) , 75-78
Open AccessThe Method of Splinting Mobile Teeth in the Presence of Small Defects of the Dentitions with Aesthetic Polymer Adhesive Splinting Prosthesis
To the presence healthy teeth is an integral part of human health. Their partial or complete loss can have complex consequences for our functioning and quality of life. There are a number of factors that lead to tooth loss. In particular, genetic factors, periodontal diseases, caries complications, poor diet and bad habits. In some cases, tooth loss can be hereditary, caused by an increased tendency to develop caries or periodontal diseases. The presence of various abnormalities in the development of teeth can also be the reason for their loss in the future. Furthermore, the most common methods of treating partial defects of the dentition combined with periodontal tissue diseases are fixed partial and adhesive metal-ceramic prostheses, the design of which involves significant preparation of the hard tissues of the teeth that limit the defect. An adhesive metal-ceramic prosthesis, the design of which consists of an artificial tooth and fixing elements made in the form of cores or overlays, completely covered with ceramic material, has a number of disadvantages and limited indications for use. For the proposed adhesive splint prosthesis allows minimally dissection of supporting teeth hard tissues; at the expense of high accuracy production maybe to be used for minor deformations of the dentition, if present carious and non-carious lesions; due to high bioinertness recommended construction of choice for periodontal tissue diseases. The purpose of the study. To increase the effectiveness of orthopedic treatment of patients with chronic periodontitis of moderate severity and to substantiate the method of splinting mobile teeth in the presence of small dentition defects in the frontal area, taking into account the anatomical features, functionality and aesthetic appearance of the structure. Materials and methods. With the help of adhesive splint prosthesis are made of high-tech polymer PEEK-"Bio Hpp" proposed a new approach to the problem of treating small dentition defects in the frontal area. A comparative analysis was conducted and the advantages of the proposed design with similar prostheses were proven. Research results. The obtained results indicate that the proposed design allows for splinting and restoration of the aesthetic appearance and integrity of the dentition, preventing the occurrence of deformations and ensuring the functionality of the maxillofacial system. Conclusions 1. The proposed design of the adhesive splint prosthesis made of high-tech polymer PEEK-"Bio Hpp" allows you to restore the integrity of the dentitions in the presence of small included defects in the frontal area and provides a good splinting result. 2. Production of a frame from high-tech polymer PEEK-"Bio Hpp”, allows to significantly reduce the depth of preparation of teeth hard tissues, providing an excellent aesthetic result, which makes it possible to significantly expand the indications for use. 3. The long-term results of the treatment indicate the absence of marginal staining at the border of the hard tissue of the tooth - indirect restoration, i.e. marginal detachment, which provides good aesthetics, functional integrity of the structure and a satisfactory splinting result.
- Open Access
- 18 May 2021
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 18 (1) , 112-116
Orthopedic treatment with fixed dentures taking into account the distribution and causes of defects in dental hard tissues
The aim of this work was to analyze the causes of complications of orthopedic treatment of dentition defects with metal-ceramic crowns and non-removable metal-ceramic bridges. Materials and methods. A total of 140 patients aged 34 to 49 years were examined during the work, who underwent the production of both single metal-ceramic crowns and non-removable metal-ceramic bridges. All patients were divided into 2 groups (70 patients each): the first one included patients with vital abutment teeth, the second one – with depulped. The abutment teeth had a different functional state – they were filled, had wedge-shaped defects or increased abrasion. Results. Orthopedic treatment showed that the manufacture of solid metal-ceramic crowns on dental teeth, which were filled more than 1 year ago, led to complications in 18 of 35 (51.4 %) patients in this group, which is insignificantly (P ˃ 0.05) by 17.2 % less than with similar prosthetics on depulped teeth. Regarding the manufacture of bridges, the trend of more complications in prosthetics on devital teeth persists, because in group I we had 20 (57.7 %) patients with complications, and in group II – 29 (82.9 %) cases, which is significantly different at the level of P < 0.05. In prosthetics of vital teeth, defects of hard tissues of which are replaced by filling material immediately before prosthetics, single crowns of complications occurred in 3 patients, i.e. in 8.6 %, which is insignificantly (P ˃ 0.05) less by 5.6 % than in group II where complications were found in 5 (14.2 %) people. Analysis of orthopedic treatment of patients with included defects of dentitions with metal-ceramic bridge prostheses revealed that when using filled teeth (filled for 1 year before prosthetics) in the case, when they were depulped, as abutment, complications were observed in 9 people, i.e. in 25.7 % of this group. This indicator insignificantly (P ˃ 0.05) exceeds the identical one from the first group (14.3 %) by 11.4 %, therefore, there is a tendency to reduce tooth resistance to negative external and internal factors, which has not acquired statistical significance. Conclusions. The study found that the frequency of complications that occur after prosthetics with fixed dentures depends on the condition of the tooth pulp, because the viable pulp provides metabolism, renewal of tooth cells and response to any damage. The need to replace fillings that were made more than 1 year ago to reduce the risk of secondary caries has been proven. Defects of hard tissues in the form of a wedge-shaped defect and the increased attrition do not increase frequency of complications in prosthetics by fixed dentures.
- 18 May 2021
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 18 (1) , 112-116
Open AccessOrthopedic treatment with fixed dentures taking into account the distribution and causes of defects in dental hard tissues
The aim of this work was to analyze the causes of complications of orthopedic treatment of dentition defects with metal-ceramic crowns and non-removable metal-ceramic bridges. Materials and methods. A total of 140 patients aged 34 to 49 years were examined during the work, who underwent the production of both single metal-ceramic crowns and non-removable metal-ceramic bridges. All patients were divided into 2 groups (70 patients each): the first one included patients with vital abutment teeth, the second one – with depulped. The abutment teeth had a different functional state – they were filled, had wedge-shaped defects or increased abrasion. Results. Orthopedic treatment showed that the manufacture of solid metal-ceramic crowns on dental teeth, which were filled more than 1 year ago, led to complications in 18 of 35 (51.4 %) patients in this group, which is insignificantly (P ˃ 0.05) by 17.2 % less than with similar prosthetics on depulped teeth. Regarding the manufacture of bridges, the trend of more complications in prosthetics on devital teeth persists, because in group I we had 20 (57.7 %) patients with complications, and in group II – 29 (82.9 %) cases, which is significantly different at the level of P < 0.05. In prosthetics of vital teeth, defects of hard tissues of which are replaced by filling material immediately before prosthetics, single crowns of complications occurred in 3 patients, i.e. in 8.6 %, which is insignificantly (P ˃ 0.05) less by 5.6 % than in group II where complications were found in 5 (14.2 %) people. Analysis of orthopedic treatment of patients with included defects of dentitions with metal-ceramic bridge prostheses revealed that when using filled teeth (filled for 1 year before prosthetics) in the case, when they were depulped, as abutment, complications were observed in 9 people, i.e. in 25.7 % of this group. This indicator insignificantly (P ˃ 0.05) exceeds the identical one from the first group (14.3 %) by 11.4 %, therefore, there is a tendency to reduce tooth resistance to negative external and internal factors, which has not acquired statistical significance. Conclusions. The study found that the frequency of complications that occur after prosthetics with fixed dentures depends on the condition of the tooth pulp, because the viable pulp provides metabolism, renewal of tooth cells and response to any damage. The need to replace fillings that were made more than 1 year ago to reduce the risk of secondary caries has been proven. Defects of hard tissues in the form of a wedge-shaped defect and the increased attrition do not increase frequency of complications in prosthetics by fixed dentures.