I. V. Yanishen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
I. V. Yanishen has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- O. V. Sidorova
Kharkiv National Medical University of the Ministry of Health of Ukraine, Kharkiv, Ukraine
4 shared publications - O.L. Fedotova
Kharkiv National Medical University of the Ministry of Health of Ukraine, Kharkiv, Ukraine
4 shared publications - Roman Kuznetsov
Kharkiv National Medical University, Kharkiv, Ukraine
4 shared publications - A. V. Pogorila
Харківський національний медичний університет, Харків, Україна
3 shared publications - K.YU. Andriienko
Kharkiv National Medical University, Kharkiv, Ukraine
3 shared publications - A.V. Pohorila
Kharkiv National Medical University of the Ministry of Health of Ukraine, Kharkiv, Ukraine
2 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Higher State Educational Establishment of Ukraine Bukovinian State Medical University in Clinical and experimental pathology
- Vol. 25 (3)
CLINICAL-FUNCTIONAL EVALUATION OF ORTHOPEDIC TREATMENT OF PATIENTS ON DENTAL IMPLANTS
Modern prosthodontics is characterized by the rapid development of digital technologies that encompass virtually all stages of prosthetic treatment, from initial diagnosis to the fabrication and fixation of definitive prosthetic restorations. Despite the active implementation of digital technologies into clinical practice, the issue of comparative evaluation of conventional and digital impression techniques during implant-supported prosthetic treatment remains relevant. In this regard, the comparative clinical and functional assessment of the outcomes of prosthetic rehabilitation on dental implants using conventional and digital impression techniques represents an important scientific and practical task aimed at improving contemporary prosthetic rehabilitation protocols. Objective. To increase the effectiveness of prosthetic rehabilitation in patients with partial edentulism through the fabrication of implant-supported fixed prosthetic restorations. Materials and Methods. The study was conducted at the Department of Prosthetic Dentistry and the University Dental Center of Kharkiv National Medical University. A total of 48 patients aged 28 to 67 years with partial secondary edentulism who underwent prosthetic rehabilitation using dental implants were included in the study. All patients were divided into two clinical groups according to the implant system used. Ethical considerations were addressed in accordance with the legislation of Ukraine, Articles 7, 8, and 12 of the Law of Ukraine “On Medicinal Products” (1996), the principles of Good Clinical Practice (International Council for Harmonisation Good Clinical Practice, ICH GCP, 2008), Order of the Ministry of Health of Ukraine No. 690 dated September 23, 2009, “On Approval of the Procedure for Conducting Clinical Trials of Medicinal Products and Expert Evaluation of Clinical Trial Materials and the Standard Regulations on Ethics Committees,” with amendments and additions, as well as the Declaration of Helsinki of the World Medical Association (1964, latest revision – 2024). The article is a fragment of the planned research project of the Department of Prosthetic Dentistry of Kharkiv National Medical University entitled “Integration of Modern Achievements in Medicine, Materials Science, and Technologies of Diagnosis, Treatment, and Rehabilitation of Patients in the Clinic of Prosthetic Dentistry” (State Registration No. 0125U000939, implementation period: 2025–2027; Principal Investigator – Head of the Department of Prosthetic Dentistry, Doctor of Medical Sciences, Professor I.V. Yanishen). All patients were in satisfactory general health and had no absolute contraindications to dental implantation and subsequent prosthetic treatment. After completion of osseointegration and maturation of peri-implant tissues, the prosthetic stage of treatment was performed. Within each clinical group, two impression protocols were applied: a conventional technique using an open-tray impression and A-silicone impression material, and a digital technique using an intraoral scanner and scan bodies. Follow-up examinations were performed at 1, 3, 6, and 12 months after fixation of the prosthetic restorations. Statistical analysis was carried out using methods of descriptive and inferential statistics with determination of the mean value (M), standard deviation (SD), Student’s t-test, and the level of statistical significance at p < 0.05. Results A total of 106 dental implants were placed, including 52 Alfabio implants and 54 Megagen implants. The average number of implants per patient was 2.21 ± 0.8. During follow-up examinations at 1, 3, 6, and 12 months, no cases of implant loss or impaired osseointegration were recorded, resulting in an implant survival rate of 100%. The obtained results are consistent with contemporary studies and confirm the high effectiveness of digital technologies in implant-supported prosthodontics. The use of intraoral scanners allows optimization of both clinical and laboratory stages of treatment, improves the accuracy of prosthetic restorations, and enhances patients’ quality of life. Conclusions. The use of digital intraoral scanning reduces the duration of the clinical impression-taking stage by 1.9 times compared with conventional A-silicone impression materials. Implant-supported fixed prosthetic restorations provide a statistically significant improvement in masticatory efficiency, as confirmed by functional assessment at all follow-up periods. Following prosthetic rehabilitation, patients demonstrated a substantial improvement in quality-of-life indicators according to the treatment satisfaction questionnaire.
- 14 October 2026
- Published by Higher State Educational Establishment of Ukraine Bukovinian State Medical University in Clinical and experimental pathology
- Vol. 25 (3)
Open AccessCLINICAL-FUNCTIONAL EVALUATION OF ORTHOPEDIC TREATMENT OF PATIENTS ON DENTAL IMPLANTS
Modern prosthodontics is characterized by the rapid development of digital technologies that encompass virtually all stages of prosthetic treatment, from initial diagnosis to the fabrication and fixation of definitive prosthetic restorations. Despite the active implementation of digital technologies into clinical practice, the issue of comparative evaluation of conventional and digital impression techniques during implant-supported prosthetic treatment remains relevant. In this regard, the comparative clinical and functional assessment of the outcomes of prosthetic rehabilitation on dental implants using conventional and digital impression techniques represents an important scientific and practical task aimed at improving contemporary prosthetic rehabilitation protocols. Objective. To increase the effectiveness of prosthetic rehabilitation in patients with partial edentulism through the fabrication of implant-supported fixed prosthetic restorations. Materials and Methods. The study was conducted at the Department of Prosthetic Dentistry and the University Dental Center of Kharkiv National Medical University. A total of 48 patients aged 28 to 67 years with partial secondary edentulism who underwent prosthetic rehabilitation using dental implants were included in the study. All patients were divided into two clinical groups according to the implant system used. Ethical considerations were addressed in accordance with the legislation of Ukraine, Articles 7, 8, and 12 of the Law of Ukraine “On Medicinal Products” (1996), the principles of Good Clinical Practice (International Council for Harmonisation Good Clinical Practice, ICH GCP, 2008), Order of the Ministry of Health of Ukraine No. 690 dated September 23, 2009, “On Approval of the Procedure for Conducting Clinical Trials of Medicinal Products and Expert Evaluation of Clinical Trial Materials and the Standard Regulations on Ethics Committees,” with amendments and additions, as well as the Declaration of Helsinki of the World Medical Association (1964, latest revision – 2024). The article is a fragment of the planned research project of the Department of Prosthetic Dentistry of Kharkiv National Medical University entitled “Integration of Modern Achievements in Medicine, Materials Science, and Technologies of Diagnosis, Treatment, and Rehabilitation of Patients in the Clinic of Prosthetic Dentistry” (State Registration No. 0125U000939, implementation period: 2025–2027; Principal Investigator – Head of the Department of Prosthetic Dentistry, Doctor of Medical Sciences, Professor I.V. Yanishen). All patients were in satisfactory general health and had no absolute contraindications to dental implantation and subsequent prosthetic treatment. After completion of osseointegration and maturation of peri-implant tissues, the prosthetic stage of treatment was performed. Within each clinical group, two impression protocols were applied: a conventional technique using an open-tray impression and A-silicone impression material, and a digital technique using an intraoral scanner and scan bodies. Follow-up examinations were performed at 1, 3, 6, and 12 months after fixation of the prosthetic restorations. Statistical analysis was carried out using methods of descriptive and inferential statistics with determination of the mean value (M), standard deviation (SD), Student’s t-test, and the level of statistical significance at p < 0.05. Results A total of 106 dental implants were placed, including 52 Alfabio implants and 54 Megagen implants. The average number of implants per patient was 2.21 ± 0.8. During follow-up examinations at 1, 3, 6, and 12 months, no cases of implant loss or impaired osseointegration were recorded, resulting in an implant survival rate of 100%. The obtained results are consistent with contemporary studies and confirm the high effectiveness of digital technologies in implant-supported prosthodontics. The use of intraoral scanners allows optimization of both clinical and laboratory stages of treatment, improves the accuracy of prosthetic restorations, and enhances patients’ quality of life. Conclusions. The use of digital intraoral scanning reduces the duration of the clinical impression-taking stage by 1.9 times compared with conventional A-silicone impression materials. Implant-supported fixed prosthetic restorations provide a statistically significant improvement in masticatory efficiency, as confirmed by functional assessment at all follow-up periods. Following prosthetic rehabilitation, patients demonstrated a substantial improvement in quality-of-life indicators according to the treatment satisfaction questionnaire.
- Open Access
- 30 June 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- Vol. 3 (2(8)) , 453-466
Comparative evaluation of acrylic base of complete removable dentures using vacuum post-polymerization method
Background. Complete secondary edentulism of the mandible remains one of the most common clinical problems in middle-aged and elderly patients and has signi-ficant medical and social importance. Comparative clinical and functional evaluation using vacuum post-polymerization treatment is scientifically substantiated and practically significant. Purpose – to improve the effectiveness of orthopedic treatment of patients with complete edentulism through comparative clinical and functional evaluation of complete removable dentures and implant-supported overdentures with vacuum-processed acrylic bases, and by analyzing oral fluid parameters at different stages of rehabilitation. Materials and methods. Group I included 16 patients treated with complete removable laminar dentures with an acrylic base manufactured using vacuum post-polymerization treatment. Group II consisted of 17 patients who underwent orthopedic treatment with implant-supported overdentures retained on two intraosseous dental implants with a locator attachment system. Results. During the observation period, adaptation occurred gradually with positive dynamics, but was better in Group II. After 1 month, denture stability in Group I was 68.7%, while in Group II it was 94.1%; after 3–6 months, stability in Group II reached 100% (p < 0.05). Masticatory efficiency increased by 28.6% in Group I and by 46.3% in Group II. The OHIP-14 score decreased by 32.4% and 51.7%, respectively. By 6 months, biochemical parameters of oral fluid normalized faster in Group II (p < 0.05). Conclusions. Implant-supported overdentures with a vacuum-treated acrylic base provide more stable functional characteristics, faster restoration of masticatory function, and better quality of life compared with conventional complete removable laminar dentures.
- 30 June 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- Vol. 3 (2(8)) , 453-466
Open AccessComparative evaluation of acrylic base of complete removable dentures using vacuum post-polymerization method
Background. Complete secondary edentulism of the mandible remains one of the most common clinical problems in middle-aged and elderly patients and has signi-ficant medical and social importance. Comparative clinical and functional evaluation using vacuum post-polymerization treatment is scientifically substantiated and practically significant. Purpose – to improve the effectiveness of orthopedic treatment of patients with complete edentulism through comparative clinical and functional evaluation of complete removable dentures and implant-supported overdentures with vacuum-processed acrylic bases, and by analyzing oral fluid parameters at different stages of rehabilitation. Materials and methods. Group I included 16 patients treated with complete removable laminar dentures with an acrylic base manufactured using vacuum post-polymerization treatment. Group II consisted of 17 patients who underwent orthopedic treatment with implant-supported overdentures retained on two intraosseous dental implants with a locator attachment system. Results. During the observation period, adaptation occurred gradually with positive dynamics, but was better in Group II. After 1 month, denture stability in Group I was 68.7%, while in Group II it was 94.1%; after 3–6 months, stability in Group II reached 100% (p < 0.05). Masticatory efficiency increased by 28.6% in Group I and by 46.3% in Group II. The OHIP-14 score decreased by 32.4% and 51.7%, respectively. By 6 months, biochemical parameters of oral fluid normalized faster in Group II (p < 0.05). Conclusions. Implant-supported overdentures with a vacuum-treated acrylic base provide more stable functional characteristics, faster restoration of masticatory function, and better quality of life compared with conventional complete removable laminar dentures.
- Open Access
- 30 June 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- Vol. 3 (2(8)) , 423-433
Comparative evaluation of fluoride ion release from glass ionomer cements for permanent fixation
Background. In modern prosthodontics, the long-term stability of fixed restorations depends largely on the properties of the bonding materials. Glass ionomer cements are of great importance, as they combine reliable adhesion to hard dental tissues, biocompatibility, and the ability to release fluoride ions over an extended period. Purpose – of this study is to evaluate the ability of glass ionomer cements to release fluoride ions after final setting, based on the results of laboratory studies. Materials and Methods. The release of fluoride ions from glass ionomer cements for permanent restoration was investigated at the laboratory of Stoma JSC. Forty-five discshaped specimens (d = 8.60 mm; h = 1.65 mm) were prepared and divided into three groups (n = 15): «Ketac Cem» (Germany), «Riva» (Australia), and glass ionomer cement based on polycarboxylic and tartaric acids (Ukraine). The specimens were incubated in buffer, demineralization (pH 4.3), and remineralization (pH 7.0) solutions. Fluoride ion concentration was determined on days 9, 15, 21, and 30. Results. A comparative evaluation was conducted based on changes in fluoride ion release by three glass ionomer cements over a 30-day period in various solutions. For «Ketac Cem», a 32.6% decrease was observed in solution «A» (p0.05); in «B», 9.4% (p<0.05); and in «C», 17.1% (p<0.01). Conclusions. All of the glass ionomer cements studied are capable of releasing fluoride ions after setting, with the rate of release depending on the material composition and environmental conditions. The most pronounced changes in indicators were observed in «Ketac Cem» and «Riva» cements, whereas the glass ionomer cement based on polycarboxylic and tartaric acids was characterized by more stable fluoride release.
- 30 June 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- Vol. 3 (2(8)) , 423-433
Open AccessComparative evaluation of fluoride ion release from glass ionomer cements for permanent fixation
Background. In modern prosthodontics, the long-term stability of fixed restorations depends largely on the properties of the bonding materials. Glass ionomer cements are of great importance, as they combine reliable adhesion to hard dental tissues, biocompatibility, and the ability to release fluoride ions over an extended period. Purpose – of this study is to evaluate the ability of glass ionomer cements to release fluoride ions after final setting, based on the results of laboratory studies. Materials and Methods. The release of fluoride ions from glass ionomer cements for permanent restoration was investigated at the laboratory of Stoma JSC. Forty-five discshaped specimens (d = 8.60 mm; h = 1.65 mm) were prepared and divided into three groups (n = 15): «Ketac Cem» (Germany), «Riva» (Australia), and glass ionomer cement based on polycarboxylic and tartaric acids (Ukraine). The specimens were incubated in buffer, demineralization (pH 4.3), and remineralization (pH 7.0) solutions. Fluoride ion concentration was determined on days 9, 15, 21, and 30. Results. A comparative evaluation was conducted based on changes in fluoride ion release by three glass ionomer cements over a 30-day period in various solutions. For «Ketac Cem», a 32.6% decrease was observed in solution «A» (p0.05); in «B», 9.4% (p<0.05); and in «C», 17.1% (p<0.01). Conclusions. All of the glass ionomer cements studied are capable of releasing fluoride ions after setting, with the rate of release depending on the material composition and environmental conditions. The most pronounced changes in indicators were observed in «Ketac Cem» and «Riva» cements, whereas the glass ionomer cement based on polycarboxylic and tartaric acids was characterized by more stable fluoride release.
- Open Access
- 17 June 2026
- Published by Poltava State Medical University (PSMU) in Актуальні проблеми сучасної медицини: Вісник Української медичної стоматологічної академії
- Vol. 26 (2) , 118-124
ASSESSMENT OF PATIENT ADAPTATION TO REMOVABLE DENTURES OVER TIME
Partial and complete edentulism remains common dental condition, leading to a growing need for prosthetic correction. The use of prosthetic appliances is often accompanied by adaptation difficulties, including discomfort, pain, speech impairment, and poor prosthesis retention, particularly in older patients. Therefore, studying the specifics of adaptation to removable prostheses is a pressing issue in modern prosthetic dentistry. Objective. To assess the adaptation and changes in quality of life among patients using partial and complete removable dentures over time. Participants and Methods. The study included 185 patients (90 men and 95 women) aged 35–85 years who underwent prosthetic correction with partial and complete removable dentures at the Department of Prosthodontics. The choice of prosthesis design was made on an individual basis, taking into account the clinical situation following an examination by prosthetic dentist. A clinical and statistical analysis of 185 outpatient records was conducted, along with a patient survey regarding adaptation time, quality of life, and primary complaints related to prosthesis use. Results. On the day the dentures were fitted, a statistically significant decline in quality of life was observed in all groups (p<0.001), followed by a gradual improvement in adaptation over the course of 14–33 days. The most pronounced difficulties in adaptation were observed in patients in the older age groups. The main complaints associated with the use of removable dentures were discomfort, speech difficulties, the gag reflex, and excessive salivation. In patients with complete removable dentures, these symptoms were observed significantly more frequently compared to partial dentures: gag reflex – 18.42±1.36% vs. 12.16±1.14% (p<0.05), excessive salivation – 14.83±1.11% vs. 6.17±0.21% (p0.01), speech impairment – 34.57±2.74% vs. 26.82±2.62% (p0.05), discomfort – 61.38±3.94% vs. 50.43±3.68% (p0.05). Patients with complete edentulism adapted to dentures more quickly compared to those with partial edentulism. Conclusion. A statistically significant association was found between patient age and the type of removable orthopedic prosthesis (p<0.05): partial dentures were more commonly used in patients in Group I, while complete dentures were more common in Group II. On the day of prosthesis placement, a significant decrease in quality of life indicators was observed in all groups (p<0.001), most pronounced in patients in the older age groups. The main complaints during the adaptation period were discomfort, pain, and speech impairment (p<0.05).
- 17 June 2026
- Published by Poltava State Medical University (PSMU) in Актуальні проблеми сучасної медицини: Вісник Української медичної стоматологічної академії
- Vol. 26 (2) , 118-124
Open AccessASSESSMENT OF PATIENT ADAPTATION TO REMOVABLE DENTURES OVER TIME
Partial and complete edentulism remains common dental condition, leading to a growing need for prosthetic correction. The use of prosthetic appliances is often accompanied by adaptation difficulties, including discomfort, pain, speech impairment, and poor prosthesis retention, particularly in older patients. Therefore, studying the specifics of adaptation to removable prostheses is a pressing issue in modern prosthetic dentistry. Objective. To assess the adaptation and changes in quality of life among patients using partial and complete removable dentures over time. Participants and Methods. The study included 185 patients (90 men and 95 women) aged 35–85 years who underwent prosthetic correction with partial and complete removable dentures at the Department of Prosthodontics. The choice of prosthesis design was made on an individual basis, taking into account the clinical situation following an examination by prosthetic dentist. A clinical and statistical analysis of 185 outpatient records was conducted, along with a patient survey regarding adaptation time, quality of life, and primary complaints related to prosthesis use. Results. On the day the dentures were fitted, a statistically significant decline in quality of life was observed in all groups (p<0.001), followed by a gradual improvement in adaptation over the course of 14–33 days. The most pronounced difficulties in adaptation were observed in patients in the older age groups. The main complaints associated with the use of removable dentures were discomfort, speech difficulties, the gag reflex, and excessive salivation. In patients with complete removable dentures, these symptoms were observed significantly more frequently compared to partial dentures: gag reflex – 18.42±1.36% vs. 12.16±1.14% (p<0.05), excessive salivation – 14.83±1.11% vs. 6.17±0.21% (p0.01), speech impairment – 34.57±2.74% vs. 26.82±2.62% (p0.05), discomfort – 61.38±3.94% vs. 50.43±3.68% (p0.05). Patients with complete edentulism adapted to dentures more quickly compared to those with partial edentulism. Conclusion. A statistically significant association was found between patient age and the type of removable orthopedic prosthesis (p<0.05): partial dentures were more commonly used in patients in Group I, while complete dentures were more common in Group II. On the day of prosthesis placement, a significant decrease in quality of life indicators was observed in all groups (p<0.001), most pronounced in patients in the older age groups. The main complaints during the adaptation period were discomfort, pain, and speech impairment (p<0.05).
- Open Access
- 8 May 2026
- Published by Individual entrepreneur Kondratets Kateryna in DENTISTRY. MEDICINE. REHABILITATION
Differentiated Application of Dental Materials in the Treatment with Fixed Dental Prostheses: A Literature Review
The article reviews modern approaches to selecting materials and fixation systems for the manufacture of fixed orthopedic dental structures. It is shown that their reliability and durability depend not only on the material's properties but also on the type of cement and adhesive system. The physico-mechanical properties of metal-ceramics, ceramics, zirconia, composite materials, and metal alloys are analyzed. It was established that modified glass ionomer and composite adhesive cements provide stronger fixation than traditional cements. The importance of digital CAD/CAM technologies and pressing, which improve the fit of structures and reduce the risk of microleakage and complications, is demonstrated. The need for differentiated material selection and fixation systems to increase the effectiveness of orthopedic treatment and the durability of fixed structures is substantiated. Objective: To analyze the scientific and practical works of domestic and foreign authors regarding the differentiated use of modern dental materials in the manufacture and fixation of fixed denture structures. Results: A search for scientific publications in the PubMed, Scopus, Web of Science, and Google Scholar databases identified 428 sources potentially relevant to the research topic. After removing 112 duplicates, 316 publications remained for further analysis. During the initial screening of titles and abstracts, 198 works were excluded, leaving 118 articles selected for full-text analysis. After a detailed analysis of the content, another 72 publications were excluded for irrelevance to the topic or for lacking relevant results. Ultimately, 46 scientific articles were included in the systematic review. The analysis included original research, systematic reviews, and meta-analyses dedicated to the use of dental materials in fixed orthopedic prosthetics and the evaluation of their physico-mechanical or clinical properties. Full-text articles in Ukrainian and English were considered. Duplicates, conference abstracts, short communications, clinical cases, and publications without full text were excluded from the analysis. Conclusions: The effectiveness of orthopedic treatment with fixed dentures largely depends on the selection of dental materials tailored to the various clinical stages. The physico-mechanical properties of materials, their adhesive characteristics, and dimensional stability affect the accuracy of structure fabrication, the quality of marginal fit, and the durability of restorations. The use of modern elastomeric impression materials and digital technologies increases the accuracy of anatomical structure transfer, while the use of adhesive composite cements ensures a stronger bond with tooth tissues and reduces the risk of microleakage.
- 8 May 2026
- Published by Individual entrepreneur Kondratets Kateryna in DENTISTRY. MEDICINE. REHABILITATION
Open AccessDifferentiated Application of Dental Materials in the Treatment with Fixed Dental Prostheses: A Literature Review
The article reviews modern approaches to selecting materials and fixation systems for the manufacture of fixed orthopedic dental structures. It is shown that their reliability and durability depend not only on the material's properties but also on the type of cement and adhesive system. The physico-mechanical properties of metal-ceramics, ceramics, zirconia, composite materials, and metal alloys are analyzed. It was established that modified glass ionomer and composite adhesive cements provide stronger fixation than traditional cements. The importance of digital CAD/CAM technologies and pressing, which improve the fit of structures and reduce the risk of microleakage and complications, is demonstrated. The need for differentiated material selection and fixation systems to increase the effectiveness of orthopedic treatment and the durability of fixed structures is substantiated. Objective: To analyze the scientific and practical works of domestic and foreign authors regarding the differentiated use of modern dental materials in the manufacture and fixation of fixed denture structures. Results: A search for scientific publications in the PubMed, Scopus, Web of Science, and Google Scholar databases identified 428 sources potentially relevant to the research topic. After removing 112 duplicates, 316 publications remained for further analysis. During the initial screening of titles and abstracts, 198 works were excluded, leaving 118 articles selected for full-text analysis. After a detailed analysis of the content, another 72 publications were excluded for irrelevance to the topic or for lacking relevant results. Ultimately, 46 scientific articles were included in the systematic review. The analysis included original research, systematic reviews, and meta-analyses dedicated to the use of dental materials in fixed orthopedic prosthetics and the evaluation of their physico-mechanical or clinical properties. Full-text articles in Ukrainian and English were considered. Duplicates, conference abstracts, short communications, clinical cases, and publications without full text were excluded from the analysis. Conclusions: The effectiveness of orthopedic treatment with fixed dentures largely depends on the selection of dental materials tailored to the various clinical stages. The physico-mechanical properties of materials, their adhesive characteristics, and dimensional stability affect the accuracy of structure fabrication, the quality of marginal fit, and the durability of restorations. The use of modern elastomeric impression materials and digital technologies increases the accuracy of anatomical structure transfer, while the use of adhesive composite cements ensures a stronger bond with tooth tissues and reduces the risk of microleakage.
- Open Access
- 3 April 2026
- Published by Poltava State Medical University (PSMU) in Актуальні проблеми сучасної медицини: Вісник Української медичної стоматологічної академії
- Vol. 26 (1) , 119-122
METHOD FOR FABRICATING INDIVIDUAL OCCLUSAL SPLINTS USING IMPROVED ACRYLIC-FREE PLASTIC
Increased wear of hard dental tissues is a common non-carious lesion accompanied by disturbances in occlusal relationships and a reduction in vertical occlusal dimension. This condition is often associated with bruxism and occlusal abnormalities, which complicate the clinical course of the disease. Purpose: to improve the technique for fabricating individual occlusal splints during the orthopedic treatment of excessive tooth wear using acrylic-free cold-curing plastic. Materials and methods. The study included 48 patients who sought care at the University Dental Center of Kharkiv National Medical University, Department of Prosthodontics. All patients underwent clinical and functional examination with assessment of the temporomandibular joint, masticatory muscles, occlusal relationships, and degree of tooth wear; orthopantomography, cone-beam computed tomography, or magnetic resonance imaging of the temporomandibular joint were performed as indicated. Anatomical impressions were taken with A-silicone material, the central relationship of the jaws was recorded, and plaster diagnostic models were made, which were plastered in a semi-adjustable articulator. The occlusal splint cap was modeled on the lower jaw, taking into account the principles of stabilization occlusion; the thickness in the chewing teeth area was 2-3 mm. The splint was made of acrylic-free plastic using cold polymerization, followed by clinical fitting. The wearing regimen was determined individually; follow-up examinations were conducted after 7-14 days and then every 1-3 months. Results. The use of individual dental splints in patients with increased abrasion of hard tooth tissues provided a significant improvement in clinical and functional indicators. After 1-3 months of treatment, 89% of patients reported a reduction or disappearance of pain syndrome and muscle tension, and 87.5% reported normalization of masticatory muscle tone. Stable occlusal contacts in the central relationship and adequate disocclusion of the lateral teeth were achieved in 91% and 85% of cases, respectively, and stabilization of the interalveolar height was achieved in 86% of patients. No progression of wear was detected in 92% of individuals, confirming the stabilizing effect of splints and their effectiveness as a preparatory stage of orthopedic treatment. Conclusion. A positive clinical outcome was observed in 83.3% of patients, and no adverse effects or complications were detected. These findings confirm the statistically significant effectiveness of the standardized method of occlusal splint therapy and support its application in both clinical practice and scientific research.
- 3 April 2026
- Published by Poltava State Medical University (PSMU) in Актуальні проблеми сучасної медицини: Вісник Української медичної стоматологічної академії
- Vol. 26 (1) , 119-122
Open AccessMETHOD FOR FABRICATING INDIVIDUAL OCCLUSAL SPLINTS USING IMPROVED ACRYLIC-FREE PLASTIC
Increased wear of hard dental tissues is a common non-carious lesion accompanied by disturbances in occlusal relationships and a reduction in vertical occlusal dimension. This condition is often associated with bruxism and occlusal abnormalities, which complicate the clinical course of the disease. Purpose: to improve the technique for fabricating individual occlusal splints during the orthopedic treatment of excessive tooth wear using acrylic-free cold-curing plastic. Materials and methods. The study included 48 patients who sought care at the University Dental Center of Kharkiv National Medical University, Department of Prosthodontics. All patients underwent clinical and functional examination with assessment of the temporomandibular joint, masticatory muscles, occlusal relationships, and degree of tooth wear; orthopantomography, cone-beam computed tomography, or magnetic resonance imaging of the temporomandibular joint were performed as indicated. Anatomical impressions were taken with A-silicone material, the central relationship of the jaws was recorded, and plaster diagnostic models were made, which were plastered in a semi-adjustable articulator. The occlusal splint cap was modeled on the lower jaw, taking into account the principles of stabilization occlusion; the thickness in the chewing teeth area was 2-3 mm. The splint was made of acrylic-free plastic using cold polymerization, followed by clinical fitting. The wearing regimen was determined individually; follow-up examinations were conducted after 7-14 days and then every 1-3 months. Results. The use of individual dental splints in patients with increased abrasion of hard tooth tissues provided a significant improvement in clinical and functional indicators. After 1-3 months of treatment, 89% of patients reported a reduction or disappearance of pain syndrome and muscle tension, and 87.5% reported normalization of masticatory muscle tone. Stable occlusal contacts in the central relationship and adequate disocclusion of the lateral teeth were achieved in 91% and 85% of cases, respectively, and stabilization of the interalveolar height was achieved in 86% of patients. No progression of wear was detected in 92% of individuals, confirming the stabilizing effect of splints and their effectiveness as a preparatory stage of orthopedic treatment. Conclusion. A positive clinical outcome was observed in 83.3% of patients, and no adverse effects or complications were detected. These findings confirm the statistically significant effectiveness of the standardized method of occlusal splint therapy and support its application in both clinical practice and scientific research.
- 31 March 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- p. 36
Designing compositions and features of crystallisation and structure formation of glass-crystalline materials for coating dental implants
Background. One of the key issues in modern implant rehabilitation in dental endoprosthetics is the overall reduction in rehabilitation time, which is associated with accelerated bone tissue regeneration. Purpose – to develop and investigate glass-ceramic coatings for dental implants that are used under immediate loading and to ensure their ability to simultaneously exhibit biological activity and strength. Materials and Methods. The goal was achieved by developing compositions of glass-crystalline coatings based on titanium alloys with a calcium phosphate silicate glass matrix, modified with biologically active components for dental implantology. Results. Glass compositions based on the R2O–RO–RO2–CaF2–R2O3–P2O5–SiO2 system were modified with a phase-forming component ratio of CaO/P2O5 = 1.28–1.67 and a CaF2 content of 2.0 ÷ 2.5 wt. %. The glass formation region was investigated and the compositions of experimental glasses were synthesised. The peculiarities of the crystallisation mechanism of experimental glasses were established, which consists in the occurrence of phase separation and self-organisation of the structure at the softening temperature, followed by volumetric fine-dispersed crystallisation with a content of crystalline phases of calcium phosphates of 50–60% with a size of 0.1–1 μm under low-temperature heat treatment conditions. The mecha- nism of structure formation of modified calcium phosphate silicate glass materials has been established, which consists in the formation of crystallisation nucleators after glass melting with clear phase boundaries at a viscosity of h = 108.89–9.1 Pa·s, which is a positive trend in the formation of a strengthened sialised structure in a short period of time. Conclusions. Thus, we have developed, researched and analysed the compositions and properties of bioactive glass-crystalline coatings on titanium alloys. The main hypothesis of the study is the ability to exhibit biological activity while ensuring strength by applying a bioactive glass-crystalline coating to the surface of the titanium alloy, which is characterised by its ability to osseointegrate within a short period of time, rapid bone tissue regeneration and non-toxicity.
- 31 March 2026
- Published by V. N. Karazin Kharkiv National University in Kharkiv Dental Journal
- p. 36
Designing compositions and features of crystallisation and structure formation of glass-crystalline materials for coating dental implants
Background. One of the key issues in modern implant rehabilitation in dental endoprosthetics is the overall reduction in rehabilitation time, which is associated with accelerated bone tissue regeneration. Purpose – to develop and investigate glass-ceramic coatings for dental implants that are used under immediate loading and to ensure their ability to simultaneously exhibit biological activity and strength. Materials and Methods. The goal was achieved by developing compositions of glass-crystalline coatings based on titanium alloys with a calcium phosphate silicate glass matrix, modified with biologically active components for dental implantology. Results. Glass compositions based on the R2O–RO–RO2–CaF2–R2O3–P2O5–SiO2 system were modified with a phase-forming component ratio of CaO/P2O5 = 1.28–1.67 and a CaF2 content of 2.0 ÷ 2.5 wt. %. The glass formation region was investigated and the compositions of experimental glasses were synthesised. The peculiarities of the crystallisation mechanism of experimental glasses were established, which consists in the occurrence of phase separation and self-organisation of the structure at the softening temperature, followed by volumetric fine-dispersed crystallisation with a content of crystalline phases of calcium phosphates of 50–60% with a size of 0.1–1 μm under low-temperature heat treatment conditions. The mecha- nism of structure formation of modified calcium phosphate silicate glass materials has been established, which consists in the formation of crystallisation nucleators after glass melting with clear phase boundaries at a viscosity of h = 108.89–9.1 Pa·s, which is a positive trend in the formation of a strengthened sialised structure in a short period of time. Conclusions. Thus, we have developed, researched and analysed the compositions and properties of bioactive glass-crystalline coatings on titanium alloys. The main hypothesis of the study is the ability to exhibit biological activity while ensuring strength by applying a bioactive glass-crystalline coating to the surface of the titanium alloy, which is characterised by its ability to osseointegrate within a short period of time, rapid bone tissue regeneration and non-toxicity.
- Open Access
- 11 February 2026
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Zaporozhye Medical Journal
- Vol. 28 (1) , 53-57
Orthopedic treatment of dentition defect in frontal division with compensated form of pathological attrition by adhesive dental bridge
In pathological attrition, teeth change the anatomical shape of the crown part of the teeth and the character of the mastication pressure distribution on the cutting and chewing surfaces. Dentition defects accompany this process and need the use of adhesive dental bridge (ADB), which is more suited to modern biotechnological requirements. Aim. To statistically analyze the dimensions of the oral surfaces of the anterior teeth in patients with a compensated form of pathological attrition, and to evaluate the potential applicability of these teeth as abutment elements for ADB. Materials and methods. We selected 30 patients (18 men and 12 women) aged 35–55 years with first-degree (attrition up to 1/3 of crown height) or second-degree (attrition up to 2/3 of crown height). From these, we formed two groups of 15 patients each. A third control group comprised 15 patients with intact dentition and physiological occlusion. We used a mathematical model from prior work for rational planning of ADB abutments in specific patients. Results. The examination results of 45 patients (270 teeth) conducted on models allowed us to determine the oral surface area of the anterior teeth, depending on the degree of pathological attrition. Conclusions. The mean occlusal surface areas of upper and lower jaw teeth have been identified. Based on clinical and laboratory experiments, this made it possible to plan the supporting elements of ADB for patients with a horizontal form of pathological dental attrition.
- 11 February 2026
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Zaporozhye Medical Journal
- Vol. 28 (1) , 53-57
Open AccessOrthopedic treatment of dentition defect in frontal division with compensated form of pathological attrition by adhesive dental bridge
In pathological attrition, teeth change the anatomical shape of the crown part of the teeth and the character of the mastication pressure distribution on the cutting and chewing surfaces. Dentition defects accompany this process and need the use of adhesive dental bridge (ADB), which is more suited to modern biotechnological requirements. Aim. To statistically analyze the dimensions of the oral surfaces of the anterior teeth in patients with a compensated form of pathological attrition, and to evaluate the potential applicability of these teeth as abutment elements for ADB. Materials and methods. We selected 30 patients (18 men and 12 women) aged 35–55 years with first-degree (attrition up to 1/3 of crown height) or second-degree (attrition up to 2/3 of crown height). From these, we formed two groups of 15 patients each. A third control group comprised 15 patients with intact dentition and physiological occlusion. We used a mathematical model from prior work for rational planning of ADB abutments in specific patients. Results. The examination results of 45 patients (270 teeth) conducted on models allowed us to determine the oral surface area of the anterior teeth, depending on the degree of pathological attrition. Conclusions. The mean occlusal surface areas of upper and lower jaw teeth have been identified. Based on clinical and laboratory experiments, this made it possible to plan the supporting elements of ADB for patients with a horizontal form of pathological dental attrition.
- Open Access
- 18 June 2025
- Published by Suchasna Stomatolohiya in SUCHASNA STOMATOLOHIYA
- No. 3,p. 126-131
Comparative Assessment of Peri-Implant Tissue Hemodynamics at the Stages of Treatment of Dental Patients with Immediate and Delayed Loading with Fixed Orthopedic Structures
The traditional approach to dental implantation assumes that to achieve proper osseointegration, implants should remain without any load for 3–4 months on the lower jaw and 4–5 months on the upper jaw. However, reducing the treatment period is desirable for both patients and dentists. This study aimed to improve the quality of life for dental patients with dentition defects by reducing the time required for osseointegration when using implants coated with a new domestic bioactive calcium phosphate silicate glass ceramic, while also studying the hemodynamic indicators of peri-implant tissues under control conditions. Materials and methods of the study. Blood microcirculation studies were performed in 20 patients of the leading group, in which implants with bioactive calcium phosphate silicate glass ceramic coating were integrated (9 women, 11 men, age from 21 to 62 years) and in 19 patients of the control group (10 women, nine men, age from 19 to 58 years), who underwent implantation according to the standard protocol for the use of conventional implants. Results of the study. In patients of the leading group, the values fluctuated slightly throughout the survey, from (10.32 ± 0.61) p. u. and a maximum of (12.47 ± 0.21) p. u., and at no stage did they differ significantly between delayed and immediate prosthetics, returning at stage 4 almost to the initial figures. As for the results of the control group, the values of all stages were within the range of (11.08 ± 0.45) p. u. to (15.23 ± 0.76) p. u. and significantly worsened (p < 0.05) at the 2nd stage of the study. Although the indicators no longer showed a significant difference after 6 months compared to the 1st stage, the detected instability still significantly affects the rate of osseointegration. Measurements taken before implantation revealed no significant difference in microcirculation among all subjects, indicating equal conditions. However, after one month, data were obtained on a substantial (p < 0.05) difference between the results of the leading and control groups for both subgroups — (12.3 ± 0.3) p. u. and (14.7 ± 0.69) p. u. respectively. Conclusions. Thus, the study indicated that when using implants coated with a new domestic bioactive calcium phosphate silicate glass ceramic, even with immediate loading, changes in the microcirculatory bed of peri-implant tissues at all stages of the study do not differ significantly.
- 18 June 2025
- Published by Suchasna Stomatolohiya in SUCHASNA STOMATOLOHIYA
- No. 3,p. 126-131
Open AccessComparative Assessment of Peri-Implant Tissue Hemodynamics at the Stages of Treatment of Dental Patients with Immediate and Delayed Loading with Fixed Orthopedic Structures
The traditional approach to dental implantation assumes that to achieve proper osseointegration, implants should remain without any load for 3–4 months on the lower jaw and 4–5 months on the upper jaw. However, reducing the treatment period is desirable for both patients and dentists. This study aimed to improve the quality of life for dental patients with dentition defects by reducing the time required for osseointegration when using implants coated with a new domestic bioactive calcium phosphate silicate glass ceramic, while also studying the hemodynamic indicators of peri-implant tissues under control conditions. Materials and methods of the study. Blood microcirculation studies were performed in 20 patients of the leading group, in which implants with bioactive calcium phosphate silicate glass ceramic coating were integrated (9 women, 11 men, age from 21 to 62 years) and in 19 patients of the control group (10 women, nine men, age from 19 to 58 years), who underwent implantation according to the standard protocol for the use of conventional implants. Results of the study. In patients of the leading group, the values fluctuated slightly throughout the survey, from (10.32 ± 0.61) p. u. and a maximum of (12.47 ± 0.21) p. u., and at no stage did they differ significantly between delayed and immediate prosthetics, returning at stage 4 almost to the initial figures. As for the results of the control group, the values of all stages were within the range of (11.08 ± 0.45) p. u. to (15.23 ± 0.76) p. u. and significantly worsened (p < 0.05) at the 2nd stage of the study. Although the indicators no longer showed a significant difference after 6 months compared to the 1st stage, the detected instability still significantly affects the rate of osseointegration. Measurements taken before implantation revealed no significant difference in microcirculation among all subjects, indicating equal conditions. However, after one month, data were obtained on a substantial (p < 0.05) difference between the results of the leading and control groups for both subgroups — (12.3 ± 0.3) p. u. and (14.7 ± 0.69) p. u. respectively. Conclusions. Thus, the study indicated that when using implants coated with a new domestic bioactive calcium phosphate silicate glass ceramic, even with immediate loading, changes in the microcirculatory bed of peri-implant tissues at all stages of the study do not differ significantly.
- Open Access
- 4 October 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Zaporozhye Medical Journal
- Vol. 26 (5) , 430-433
Effect of adhesives on the sensitivity of dental tissues
Currently, the issue of increased dentin sensitivity after operations for hard dental tissue preparation during the therapeutic treatment of the carious process, as well as during orthopedic treatment of various types with non-removable dentures, has retained its relevance. Pain management is the prevention of postoperative complication development and ensures high-quality treatment results. Aim. The purpose of the literature review in this paper was to draw specialists’ attention to the use of low-solvent adhesive systems of various types to manage postoperative sensitivity of hard dental tissues. Materials and methods. More than 30 literature sources focused on studying action mechanisms of known generations of dental adhesive systems and their effects on changes in postoperative sensitivity of dental hard tissues as a result of a high-quality protective film formation on the dentin surface have been analyzed. Results. The use of various adhesive systems to reduce postoperative sensitivity of soft tissues with the formation of a high-quality protective film on the dentin surface that seals the dentinal tubules is of great importance for obtaining qualitative treatment results and increasing its effectiveness. However, various reactive substances (solvents, acetone), which are components of most adhesives, have a strong impact on their quality and significantly reduce the indications for their use. Conclusions. Thus, studying the action mechanisms of adhesives on dental tissues, searching for the formulation of new adhesive systems with a lower solvent content would expand the indications for their use as therapeutic and prophylactic drugs to reduce pain sensitivity of hard dental tissues after preparation.
- 4 October 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Zaporozhye Medical Journal
- Vol. 26 (5) , 430-433
Open AccessEffect of adhesives on the sensitivity of dental tissues
Currently, the issue of increased dentin sensitivity after operations for hard dental tissue preparation during the therapeutic treatment of the carious process, as well as during orthopedic treatment of various types with non-removable dentures, has retained its relevance. Pain management is the prevention of postoperative complication development and ensures high-quality treatment results. Aim. The purpose of the literature review in this paper was to draw specialists’ attention to the use of low-solvent adhesive systems of various types to manage postoperative sensitivity of hard dental tissues. Materials and methods. More than 30 literature sources focused on studying action mechanisms of known generations of dental adhesive systems and their effects on changes in postoperative sensitivity of dental hard tissues as a result of a high-quality protective film formation on the dentin surface have been analyzed. Results. The use of various adhesive systems to reduce postoperative sensitivity of soft tissues with the formation of a high-quality protective film on the dentin surface that seals the dentinal tubules is of great importance for obtaining qualitative treatment results and increasing its effectiveness. However, various reactive substances (solvents, acetone), which are components of most adhesives, have a strong impact on their quality and significantly reduce the indications for their use. Conclusions. Thus, studying the action mechanisms of adhesives on dental tissues, searching for the formulation of new adhesive systems with a lower solvent content would expand the indications for their use as therapeutic and prophylactic drugs to reduce pain sensitivity of hard dental tissues after preparation.