Branislav Petrović
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Branislav Petrović has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Miloš Banjac
Univerzitet u Beogradu, Mašinski fakultet
5 shared publications - Marija Vasilev
Univerzitet u Beogradu, Mašinski fakultet
2 shared publications - Sandra Kovačević
Mašinski fakultet Univerziteta u Beogradu, Kraljice Marije 16, Beograd
2 shared publications - Bogdan Ristić
University of Belgrade Faculty of Mechanical Engineering
1 shared publication - Ivan Božić
University of Belgrade Faculty of Mechanical Engineering
1 shared publication Kraljice Marije 16 Mašinski fakultet Univerziteta u Beogradu
1 shared publication
Latest Publications
- 23 October 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (2)
Tehnoekonomska analiza kompresionog i apsorpcionog sistema za solarno hlađenje
U radu je prikazana tehnoekonomska analiza rada i sprovedeno poređenje dva rashladna postrojenja kojima je moguće ostvariti tzv. solarno hlađenje: kompresionog rashladnog postrojenja i apsorpcionog rashladnog postrojenja. Energija sunčevog zračenja predstavlja primarni energetski izvor za oba postrojenja. Razlike između sistema odnose se na način konverzije energije i princip ostvarivanja rashladnog procesa. Kod kompresionog rashladnog postrojenja solarna energija se konvertuje u električnu energiju primenom fotonaponskih prijemnika sunčeve energije, koja se zatim koristi za pogon kompresora. Kod apsorpcionog rashladnog postrojenja rashladni proces se ostvaruje korišćenjem toplote, koja se obezbeđuje pomoću termičkih prijemnika sunčeve energije. Radi obezbeđivanja uporedivosti rezultata, oba rashladna sistema analizirana su za istu nominalnu rashladnu snagu od 15 kW.
- 23 October 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (2)
Tehnoekonomska analiza kompresionog i apsorpcionog sistema za solarno hlađenje
U radu je prikazana tehnoekonomska analiza rada i sprovedeno poređenje dva rashladna postrojenja kojima je moguće ostvariti tzv. solarno hlađenje: kompresionog rashladnog postrojenja i apsorpcionog rashladnog postrojenja. Energija sunčevog zračenja predstavlja primarni energetski izvor za oba postrojenja. Razlike između sistema odnose se na način konverzije energije i princip ostvarivanja rashladnog procesa. Kod kompresionog rashladnog postrojenja solarna energija se konvertuje u električnu energiju primenom fotonaponskih prijemnika sunčeve energije, koja se zatim koristi za pogon kompresora. Kod apsorpcionog rashladnog postrojenja rashladni proces se ostvaruje korišćenjem toplote, koja se obezbeđuje pomoću termičkih prijemnika sunčeve energije. Radi obezbeđivanja uporedivosti rezultata, oba rashladna sistema analizirana su za istu nominalnu rashladnu snagu od 15 kW.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Poređenje i analiza vrednosti koeficijenta transmisionih gubitaka toplote prema tlu određenog prema EN ISO 13790:2010 i EN ISO 13370:2017
U nameri da se ustanovi kolike razlike nastaju pri korišćenju u Srbiji trenutno aktuelnog proračuna za određivanje koeficijenta transmisionih gubitaka toplote prema tlu prema EN ISO 13790:2010, čija je upotreba propisana Pravilnikom o energetskoj efikasnosti zgrada („Sl. glasnik RS“, br. 61/2011) i proračuna prema standardu EN ISO 13370:2017, koga propisuje nova revidirana direktiva EPBD EU/2024/1275 u radu su predstavljene obe metode, a rezultati proračuna i odstupanja upoređeni i analizirani na konkretnom primeru. Između ostalog, ustanovljeno je da za razliku od prethodne mesečne/sezonske metode, utvrđene standardom EN ISO 13790, koja ne obuhvata inerciju tla, metoda iz standarda EN ISO 13370:2017 obuhvata ne samo razlike temperature zemljišta u odnosu na temperaturu spoljašnjeg vazduha, već i inertnost, tj. kašnjenje promene temperature tla u odnosu na temperaturu spoljašnjeg vazduha, što je čini superiornijom, a rezultate dobijene njenim korišćenjem kvalitetnijim i pouzdanijim.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Poređenje i analiza vrednosti koeficijenta transmisionih gubitaka toplote prema tlu određenog prema EN ISO 13790:2010 i EN ISO 13370:2017
U nameri da se ustanovi kolike razlike nastaju pri korišćenju u Srbiji trenutno aktuelnog proračuna za određivanje koeficijenta transmisionih gubitaka toplote prema tlu prema EN ISO 13790:2010, čija je upotreba propisana Pravilnikom o energetskoj efikasnosti zgrada („Sl. glasnik RS“, br. 61/2011) i proračuna prema standardu EN ISO 13370:2017, koga propisuje nova revidirana direktiva EPBD EU/2024/1275 u radu su predstavljene obe metode, a rezultati proračuna i odstupanja upoređeni i analizirani na konkretnom primeru. Između ostalog, ustanovljeno je da za razliku od prethodne mesečne/sezonske metode, utvrđene standardom EN ISO 13790, koja ne obuhvata inerciju tla, metoda iz standarda EN ISO 13370:2017 obuhvata ne samo razlike temperature zemljišta u odnosu na temperaturu spoljašnjeg vazduha, već i inertnost, tj. kašnjenje promene temperature tla u odnosu na temperaturu spoljašnjeg vazduha, što je čini superiornijom, a rezultate dobijene njenim korišćenjem kvalitetnijim i pouzdanijim.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Određivnje količine toplote akumulisane u zidu pri nestacionarnim promenama temperature spoljašnjeg vazduh
Iako standard EN ISO 13790:2010 „Energetske performanse zgrada – Proračun energije koja se koristi za grejanje i hlađenje“ definiše tri metode proračuna (kvazi-stacionarni mesečni metod i dva dinamička – jednostavan i detaljan časovni metod), trenutno važeći Pravilnik o energetskoj efikasnosti zgrada (Sl. glasnik RS, br. 61/2011) i dalje propisuje primenu najjednostavnijeg i najnepouzdanijeg kvazi-stacionarnog mesečnog metoda za određivanje godišnje potrebne količine toplote potrebne za grejanje zgrada. Ovaj pristup se zasniva na pretpostavci stacionarnog prolaženja toplote, pri čemu se zanemaruju vremenske promene temperature spoljašnjeg vazduha i efekti akumulacije toplote u građevinskim elementima, što može dovesti do značajnih odstupanja u proceni toplotnih gubitaka. Sa ciljem utvrđivanja greške koja nastaje primenom ova dva pristupa, u radu je izvršeno poređenje vrednosti toplotnih protoka dobijenih stacionarnim i nestacionarnim, odnosno dinamičkim pristupom proračunu prolaženja toplote kroz spoljašnji zid tokom zimskog perioda. Analizirana su dva karakteristična slučaja: zid od pune opeke debljine 25 cm i zid od opeke sa dodatnim termoizolacionim slojem debljine 10 cm sa spoljašnje strane. Nestacionarno harmonijsko prolaženje toplote modelirano je numeričkim rešavanjem Furijeove jednačine metodom konačnih razlika, uz potpuno implicitnu vremensku diskretizaciju, primenom simulacija razvijenih u programskom jeziku Python. Dobijeni rezultati pokazuju da stacionarni proračun nije u stanju da opiše razliku između ulaznog i izlaznog toplotnog protoka, niti da kvantifikuje količinu toplote akumulisane u zidu, dok nestacionarni, odnosno dinamički pristup, koji obuhvata vremenske promene temperature spoljašnjeg vazduha i efekte akumulacije toplote u građevinskim elementima, omogućava znatno realniji opis termičkog ponašanja konstrukcije.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Određivnje količine toplote akumulisane u zidu pri nestacionarnim promenama temperature spoljašnjeg vazduh
Iako standard EN ISO 13790:2010 „Energetske performanse zgrada – Proračun energije koja se koristi za grejanje i hlađenje“ definiše tri metode proračuna (kvazi-stacionarni mesečni metod i dva dinamička – jednostavan i detaljan časovni metod), trenutno važeći Pravilnik o energetskoj efikasnosti zgrada (Sl. glasnik RS, br. 61/2011) i dalje propisuje primenu najjednostavnijeg i najnepouzdanijeg kvazi-stacionarnog mesečnog metoda za određivanje godišnje potrebne količine toplote potrebne za grejanje zgrada. Ovaj pristup se zasniva na pretpostavci stacionarnog prolaženja toplote, pri čemu se zanemaruju vremenske promene temperature spoljašnjeg vazduha i efekti akumulacije toplote u građevinskim elementima, što može dovesti do značajnih odstupanja u proceni toplotnih gubitaka. Sa ciljem utvrđivanja greške koja nastaje primenom ova dva pristupa, u radu je izvršeno poređenje vrednosti toplotnih protoka dobijenih stacionarnim i nestacionarnim, odnosno dinamičkim pristupom proračunu prolaženja toplote kroz spoljašnji zid tokom zimskog perioda. Analizirana su dva karakteristična slučaja: zid od pune opeke debljine 25 cm i zid od opeke sa dodatnim termoizolacionim slojem debljine 10 cm sa spoljašnje strane. Nestacionarno harmonijsko prolaženje toplote modelirano je numeričkim rešavanjem Furijeove jednačine metodom konačnih razlika, uz potpuno implicitnu vremensku diskretizaciju, primenom simulacija razvijenih u programskom jeziku Python. Dobijeni rezultati pokazuju da stacionarni proračun nije u stanju da opiše razliku između ulaznog i izlaznog toplotnog protoka, niti da kvantifikuje količinu toplote akumulisane u zidu, dok nestacionarni, odnosno dinamički pristup, koji obuhvata vremenske promene temperature spoljašnjeg vazduha i efekte akumulacije toplote u građevinskim elementima, omogućava znatno realniji opis termičkog ponašanja konstrukcije.
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (3) , 21-29
Calculation of Annual Energy Consumption of a Heat Pump by the Bin-method
Heat pumps are electrical devices that transfer thermal energy from the environment into a heated space. Thanks to their ability, compared to electric resistance heaters, to deliver three to six times more thermal energy to the conditioned space, heat pumps represent an unrivaled solution in heating technology in terms of efficiency. When the thermal energy source is outdoor air — as in the case of air-to-air heat pumps — their efficiency directly depends on the temperature of the outdoor air. Therefore, the assessment of the total energy consumption of a heat pump must be based on a methodology that takes into account the variation of this temperature. According to Standard EN 15316, two methods are defined for determining the total energy consumption of a heat pump: the degree-day method and the temperature-bin method. In domestic practice, only the simpler and less accurate degree-day method is used. The temperature-bin method, although more reliable, has remained almost unknown, probably due to the need for hourly outdoor air temperature data. To present and bring this method closer to engineering practice, the paper describes the theoretical background and outlines the main steps of the method, while its application is demonstrated through a case study of the EPS AD office building in Bajina Bašta. By grouping actual hourly outdoor air temperature data into temperature bins and linking them with the operating points of the heat pump, while including the operation of auxiliary equipment and backup heaters, the total annual electricity consumption was determined. The obtained consumption of 56,150 kWh of electricity — of which 86% occurs in the heating and 14% in the cooling mode — clearly indicates the dominant influence of winter hours on total energy use.
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (3) , 21-29
Calculation of Annual Energy Consumption of a Heat Pump by the Bin-method
Heat pumps are electrical devices that transfer thermal energy from the environment into a heated space. Thanks to their ability, compared to electric resistance heaters, to deliver three to six times more thermal energy to the conditioned space, heat pumps represent an unrivaled solution in heating technology in terms of efficiency. When the thermal energy source is outdoor air — as in the case of air-to-air heat pumps — their efficiency directly depends on the temperature of the outdoor air. Therefore, the assessment of the total energy consumption of a heat pump must be based on a methodology that takes into account the variation of this temperature. According to Standard EN 15316, two methods are defined for determining the total energy consumption of a heat pump: the degree-day method and the temperature-bin method. In domestic practice, only the simpler and less accurate degree-day method is used. The temperature-bin method, although more reliable, has remained almost unknown, probably due to the need for hourly outdoor air temperature data. To present and bring this method closer to engineering practice, the paper describes the theoretical background and outlines the main steps of the method, while its application is demonstrated through a case study of the EPS AD office building in Bajina Bašta. By grouping actual hourly outdoor air temperature data into temperature bins and linking them with the operating points of the heat pump, while including the operation of auxiliary equipment and backup heaters, the total annual electricity consumption was determined. The obtained consumption of 56,150 kWh of electricity — of which 86% occurs in the heating and 14% in the cooling mode — clearly indicates the dominant influence of winter hours on total energy use.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Energy eff,p. 188-196
Analytical assessment of cooling degree-days for estimating energy consumption in building sector during cooling season in Belgrade
Although the degree-day method for heating is classified as a single-parameter method, as it only accounts for daily changes in outdoor air temperature to estimate the heating demand of a building due to climatic influences, it has proven to be highly reliable over decades of practice and is now widely regarded as a standard method for determining heating requirements. However, due to evident climate changes and rising outdoor air temperatures, treating the heating degree days as a prescribed constant value for the specified location, leads to significantly inaccurate results, as demonstrated in this paper through an analysis of data from the Republic Hydrometeorological Service. Meanwhile, the use of the cooling degree days method to determine cooling demand has proven to be highly unreliable. This is because the method does not account for solar radiation, which, during the summer months, is as significant a factor as outdoor air temperature. To address this issue, while preserving the core concept of the method the heat load to be removed from a cooled space is proportional to the difference between the average daily outdoor air temperature and the base indoor temperature, a considerably lower base indoor temperature can be used in place of the internal design (reference) temperature. This paper presents the corrected method, along with international experiences and best practices, and includes data from the Republic Hydrometeorological Service. Additionally, cooling degree days for Belgrade have been calculated and presented, providing more accurate and reliable cooling demand forecasts.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Energy eff,p. 188-196
Open AccessAnalytical assessment of cooling degree-days for estimating energy consumption in building sector during cooling season in Belgrade
Although the degree-day method for heating is classified as a single-parameter method, as it only accounts for daily changes in outdoor air temperature to estimate the heating demand of a building due to climatic influences, it has proven to be highly reliable over decades of practice and is now widely regarded as a standard method for determining heating requirements. However, due to evident climate changes and rising outdoor air temperatures, treating the heating degree days as a prescribed constant value for the specified location, leads to significantly inaccurate results, as demonstrated in this paper through an analysis of data from the Republic Hydrometeorological Service. Meanwhile, the use of the cooling degree days method to determine cooling demand has proven to be highly unreliable. This is because the method does not account for solar radiation, which, during the summer months, is as significant a factor as outdoor air temperature. To address this issue, while preserving the core concept of the method the heat load to be removed from a cooled space is proportional to the difference between the average daily outdoor air temperature and the base indoor temperature, a considerably lower base indoor temperature can be used in place of the internal design (reference) temperature. This paper presents the corrected method, along with international experiences and best practices, and includes data from the Republic Hydrometeorological Service. Additionally, cooling degree days for Belgrade have been calculated and presented, providing more accurate and reliable cooling demand forecasts.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. vol. 20, i,p. 132-141
An overview on optimal modeling of hybrid renewable energy systems for enhancing energy management strategies
To meet the growing demand for electricity generation, the use of renewable energy sources represents an ideal alternative to traditional resources. Compared to individual systems utilizing renewable energy sources, hybrid renewable energy systems (HRES) for electricity generation combine renewable energy sources and/or fossil fuels, providing more reliable electricity supply while achieving environmental and economic sustainability. It is crucial to optimally model all components of hybrid energy systems to meet overall electricity demands with minimal investment and operational costs. This paper provides an overview of currently available commercial software for optimizing hybrid renewable energy systems, with a specific focus on the software Homer (Hybrid Optimization of Multiple Electric Renewables). Approaches and phases of the optimization process for these systems are presented, as well as key parameters that must be considered during analysis.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. vol. 20, i,p. 132-141
Open AccessAn overview on optimal modeling of hybrid renewable energy systems for enhancing energy management strategies
To meet the growing demand for electricity generation, the use of renewable energy sources represents an ideal alternative to traditional resources. Compared to individual systems utilizing renewable energy sources, hybrid renewable energy systems (HRES) for electricity generation combine renewable energy sources and/or fossil fuels, providing more reliable electricity supply while achieving environmental and economic sustainability. It is crucial to optimally model all components of hybrid energy systems to meet overall electricity demands with minimal investment and operational costs. This paper provides an overview of currently available commercial software for optimizing hybrid renewable energy systems, with a specific focus on the software Homer (Hybrid Optimization of Multiple Electric Renewables). Approaches and phases of the optimization process for these systems are presented, as well as key parameters that must be considered during analysis.