Oliver Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Oliver Smith has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Reuben D. O'DEa
University of Nottingham
2 shared publications - Argyris Oraiopoulos
Building Stock Lab, University College London, London WC1H 0NN, UK
1 shared publication David Shipworth
1 shared publication- Dominic Humphrey
UCL Energy Institute, Bartlett Faculty of the Built Environment, University College London, London
1 shared publication E. Farcot
School of Mathematical Sciences, University of Nottingham, Nottingham NG7 2RD, United Kingdom
1 shared publication- Etienne Farcot
School of Mathematical Sciences, University of Nottingham, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Quantifying the impact of hybrid heat pump uptake in a flexibly operated UK urban low-voltage distribution network
As an alternative to domestic monovalent heat pumps (MHP, i.e., pure electric heat pumps), hybrid heat pumps (HHP) combine gas boilers and lower-capacity electric heat pumps to provide residential heating. A potential major impact of flexibly operated HHPs is reducing or deferring the need for upgrading low-voltage distribution networks, especially secondary substations. Where heat pump deployment is limited by network capacity, HHPs may also provide more electrification of domestic heat demand and thus carbon reduction. This paper aims to quantify the impact at the secondary substation level on a UK urban residential low-voltage distribution network (LVDN) of different mixtures of EVs, MHPs, and HHPs, using a bottom-up stochastic framework. The domestic heating demand is modelled dynamically and estimated endogenously using empirically fitted dwelling-level grey-box thermal models to represent heterogeneous building thermal inertia and its role in flexible heat-pump operation. The dwelling energy demand results are aggregated to estimate substation stress in the local network. We first replicate observed findings that undiversified cost-minimizing control can synchronize flexible heating and EV charging, creating rebound peaks. We then test a uniformly randomized temporal offset applied to a day-ahead time-of-use tariff and find that a two-hour maximum offset in both directions substantially reduces aggregated peak demand with a limited increase in total LVDN energy cost.It is found that an HHP reduces the After Diversity Maximum Demand by 0.7-1.0kW per average dwelling compared to an MHP. HHPs unlock 20-40% additional carbon savings compared to MHPs in constrained LVDN cases, while EV penetration dominates the increase in aggregated peak electricity load. The results also suggest the significance of integrating local network constraints into the deployment and operation of flexible residential electricity demands.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessQuantifying the impact of hybrid heat pump uptake in a flexibly operated UK urban low-voltage distribution network
As an alternative to domestic monovalent heat pumps (MHP, i.e., pure electric heat pumps), hybrid heat pumps (HHP) combine gas boilers and lower-capacity electric heat pumps to provide residential heating. A potential major impact of flexibly operated HHPs is reducing or deferring the need for upgrading low-voltage distribution networks, especially secondary substations. Where heat pump deployment is limited by network capacity, HHPs may also provide more electrification of domestic heat demand and thus carbon reduction. This paper aims to quantify the impact at the secondary substation level on a UK urban residential low-voltage distribution network (LVDN) of different mixtures of EVs, MHPs, and HHPs, using a bottom-up stochastic framework. The domestic heating demand is modelled dynamically and estimated endogenously using empirically fitted dwelling-level grey-box thermal models to represent heterogeneous building thermal inertia and its role in flexible heat-pump operation. The dwelling energy demand results are aggregated to estimate substation stress in the local network. We first replicate observed findings that undiversified cost-minimizing control can synchronize flexible heating and EV charging, creating rebound peaks. We then test a uniformly randomized temporal offset applied to a day-ahead time-of-use tariff and find that a two-hour maximum offset in both directions substantially reduces aggregated peak demand with a limited increase in total LVDN energy cost.It is found that an HHP reduces the After Diversity Maximum Demand by 0.7-1.0kW per average dwelling compared to an MHP. HHPs unlock 20-40% additional carbon savings compared to MHPs in constrained LVDN cases, while EV penetration dominates the increase in aggregated peak electricity load. The results also suggest the significance of integrating local network constraints into the deployment and operation of flexible residential electricity demands.
- Open Access
- 14 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (10) , 4909
Metrics for Adaptation and Resilience Risks for Non-Domestic Buildings: How Many People in Great Britain Will Be Affected by Flooding and Overheating Risks?
Great Britain has a temperate climate, but like other countries, its weather patterns have already been profoundly affected by climate change, and the changes are very likely to continue for decades. It also has an older building stock than most other countries, which may mean it is more difficult to adapt the built environment to reduce vulnerability to climate hazards. However, Great Britain has excellent mapping and buildings data. The built environment is better described than most other countries, and the authors’ work on the National Buildings Database for Great Britain, which draws together the most reliable sources of data covering non-domestic buildings in England, Scotland and Wales, provides an unparalleled opportunity to evaluate how many people will be affected by climate hazards. There has been considerable research effort assessing how housing will be affected by climate change, but so far much less systematic assessment of impacts on non-domestic buildings. Here, the authors examine three aspects of climate hazard affecting people in non-domestic buildings in Great Britain: (1) Overheating—How many and what types of non-domestic buildings are vulnerable to overheating risks in a heat wave? What total floor area is affected, and how many people typically occupy these buildings? (2) Flooding—How many and what types of non-domestic buildings are threatened by flooding now and in 2080? How much floorspace is threatened, and how many people typically occupy these buildings? (3) Safe space—How much air-conditioned ‘safe space’ is available where people vulnerable to overheating risks could retreat to in an emergency overheating event (e.g., schools or hospitals)? How many people could be accommodated, and what fraction of the total GB working population does this represent? We propose five new metrics to assess two of the immediate hazards posed by climate change (overheating and flooding) and to begin to assess to what extent Great Britain could find temporary accommodation for people displaced by these hazards.
- 14 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (10) , 4909
Open AccessMetrics for Adaptation and Resilience Risks for Non-Domestic Buildings: How Many People in Great Britain Will Be Affected by Flooding and Overheating Risks?
Great Britain has a temperate climate, but like other countries, its weather patterns have already been profoundly affected by climate change, and the changes are very likely to continue for decades. It also has an older building stock than most other countries, which may mean it is more difficult to adapt the built environment to reduce vulnerability to climate hazards. However, Great Britain has excellent mapping and buildings data. The built environment is better described than most other countries, and the authors’ work on the National Buildings Database for Great Britain, which draws together the most reliable sources of data covering non-domestic buildings in England, Scotland and Wales, provides an unparalleled opportunity to evaluate how many people will be affected by climate hazards. There has been considerable research effort assessing how housing will be affected by climate change, but so far much less systematic assessment of impacts on non-domestic buildings. Here, the authors examine three aspects of climate hazard affecting people in non-domestic buildings in Great Britain: (1) Overheating—How many and what types of non-domestic buildings are vulnerable to overheating risks in a heat wave? What total floor area is affected, and how many people typically occupy these buildings? (2) Flooding—How many and what types of non-domestic buildings are threatened by flooding now and in 2080? How much floorspace is threatened, and how many people typically occupy these buildings? (3) Safe space—How much air-conditioned ‘safe space’ is available where people vulnerable to overheating risks could retreat to in an emergency overheating event (e.g., schools or hospitals)? How many people could be accommodated, and what fraction of the total GB working population does this represent? We propose five new metrics to assess two of the immediate hazards posed by climate change (overheating and flooding) and to begin to assess to what extent Great Britain could find temporary accommodation for people displaced by these hazards.
- Open Access
- 27 February 2024
- Published by American Physical Society (APS) in PRX Energy
- Vol. 3 (1) , 013011
Stability Analysis of Electrical Microgrids and Their Control Systems
The drive towards renewable energy generation is causing fundamental changes in both the structure and dynamics of power grids. Their topology is becoming increasingly decentralized due to distributed, embedded generation, and the emergence of microgrids. Grid dynamics are being impacted by decreasing inertia, as conventional generators with massive spinning cores are replaced by dc renewable sources. This leads to a risk of destabilization and places an upper limit on the volume of renewable power sources that can be installed. A wide variety of different control schemes have been proposed to overcome this problem. Such schemes fall into two broad categories: so-called “grid-following” controllers that seek to match output ac power with grid frequency, and “grid-forming” systems that seek to boost grid stability. The latter frequently work by providing synthetic inertia, enabling dc renewable sources to emulate conventional generators. This paper uses the master stability function methodology to analyze the stability of synchrony in microgrids of arbitrary size and containing arbitrary control systems. This approach provides a powerful and computationally efficient framework in which to benchmark the impact of any number of renewable sources on grid stability and thereby to support microgrid design strategies. The method is demonstrated by computing stability bounds for two different grid-forming systems, providing bounds on the feasible number of generators that can be accommodated. In addition, we contrast our results with predictions from a simplistic but widely used phase-oscillator model, finding that such descriptions significantly over estimate the grid stability properties. Published by the American Physical Society 2024
- 27 February 2024
- Published by American Physical Society (APS) in PRX Energy
- Vol. 3 (1) , 013011
Open AccessStability Analysis of Electrical Microgrids and Their Control Systems
The drive towards renewable energy generation is causing fundamental changes in both the structure and dynamics of power grids. Their topology is becoming increasingly decentralized due to distributed, embedded generation, and the emergence of microgrids. Grid dynamics are being impacted by decreasing inertia, as conventional generators with massive spinning cores are replaced by dc renewable sources. This leads to a risk of destabilization and places an upper limit on the volume of renewable power sources that can be installed. A wide variety of different control schemes have been proposed to overcome this problem. Such schemes fall into two broad categories: so-called “grid-following” controllers that seek to match output ac power with grid frequency, and “grid-forming” systems that seek to boost grid stability. The latter frequently work by providing synthetic inertia, enabling dc renewable sources to emulate conventional generators. This paper uses the master stability function methodology to analyze the stability of synchrony in microgrids of arbitrary size and containing arbitrary control systems. This approach provides a powerful and computationally efficient framework in which to benchmark the impact of any number of renewable sources on grid stability and thereby to support microgrid design strategies. The method is demonstrated by computing stability bounds for two different grid-forming systems, providing bounds on the feasible number of generators that can be accommodated. In addition, we contrast our results with predictions from a simplistic but widely used phase-oscillator model, finding that such descriptions significantly over estimate the grid stability properties. Published by the American Physical Society 2024
- Top Cited PapersOpen Access
- 4 March 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (9) , eabj6734
The effect of renewable energy incorporation on power grid stability and resilience
Contemporary proliferation of renewable power generation is causing an overhaul in the topology, composition, and dynamics of electrical grids. These low-output, intermittent generators are widely distributed throughout the grid, including at the household level. It is critical for the function of modern power infrastructure to understand how this increasingly distributed layout affects network stability and resilience. This paper uses dynamical models, household power consumption, and photovoltaic generation data to show how these characteristics vary with the level of distribution. It is shown that resilience exhibits daily oscillations as the grid’s effective structure and the power demand fluctuate. This can lead to a substantial decrease in grid resilience, explained by periods of highly clustered generator output. Moreover, the addition of batteries, while enabling consumer self-sufficiency, fails to ameliorate these problems. The methodology identifies a grid’s susceptibility to disruption resulting from its network structure and modes of operation.
- 4 March 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (9) , eabj6734
Top Cited PapersOpen AccessThe effect of renewable energy incorporation on power grid stability and resilience
Contemporary proliferation of renewable power generation is causing an overhaul in the topology, composition, and dynamics of electrical grids. These low-output, intermittent generators are widely distributed throughout the grid, including at the household level. It is critical for the function of modern power infrastructure to understand how this increasingly distributed layout affects network stability and resilience. This paper uses dynamical models, household power consumption, and photovoltaic generation data to show how these characteristics vary with the level of distribution. It is shown that resilience exhibits daily oscillations as the grid’s effective structure and the power demand fluctuate. This can lead to a substantial decrease in grid resilience, explained by periods of highly clustered generator output. Moreover, the addition of batteries, while enabling consumer self-sufficiency, fails to ameliorate these problems. The methodology identifies a grid’s susceptibility to disruption resulting from its network structure and modes of operation.
- 26 February 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 101 (2) , 020301
Cascading failures in networks of heterogeneous node behavior
Variability in the dynamical function of nodes comprising a complex network impacts upon cascading failures that can compromise the network's ability to operate. Node types correspond to sources, sinks, or passive conduits of a current flow, applicable to renewable electrical power microgrids containing a variable number of intermittently operating generators and consumers of power. The resilience to cascading failures of ensembles of synthetic networks with different topology is examined as a function of the edge current carrying capacity and mix of node types, together with exemplar real-world networks. While a network with a homogeneous composition of node types can be resilient to failure, onewith an identical topology but with heterogeneous nodes can be strongly susceptible to failure. For networks with similar numbers of sources, sinks, and passive nodes the mean resilience decreases as networks become more disordered. Nevertheless all network topologies have enhanced regions of resilience, accessible by the manipulation of node composition and functionality.
- 26 February 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 101 (2) , 020301
Cascading failures in networks of heterogeneous node behavior
Variability in the dynamical function of nodes comprising a complex network impacts upon cascading failures that can compromise the network's ability to operate. Node types correspond to sources, sinks, or passive conduits of a current flow, applicable to renewable electrical power microgrids containing a variable number of intermittently operating generators and consumers of power. The resilience to cascading failures of ensembles of synthetic networks with different topology is examined as a function of the edge current carrying capacity and mix of node types, together with exemplar real-world networks. While a network with a homogeneous composition of node types can be resilient to failure, onewith an identical topology but with heterogeneous nodes can be strongly susceptible to failure. For networks with similar numbers of sources, sinks, and passive nodes the mean resilience decreases as networks become more disordered. Nevertheless all network topologies have enhanced regions of resilience, accessible by the manipulation of node composition and functionality.