  • Open Access

    Sustainable overhead line equipment foundations with optimised shape and backfilling

    by Michael John Brown, Craig Davidson, Charlie John Shepherd, Stuart Martin Flint, Stephen Mbisike

    Methods to enhance the tensile capacity and optimise the design of concrete pad foundations for overhead line equipment were investigated with the aim of reducing environmental impacts and costs. Using finite-element analysis and centrifuge modelling in sand, the effects of chamfering the pad's upper edge and varying the density of the material used to backfill the excavation were explored. A 30–40° chamfered edge on the pad increased the tensile capacity by up to 40% at low embedment ratios, shifting the failure surface origin from the pad top to the bottom. The backfill density above the foundation was shown to influence the failure mechanisms. When the backfill was less dense than the native soil, vertical failure surfaces formed. Conversely, when the relative densities of both the backfill and native soil were 60% or higher, transitional shear planes emerged. When the backfill’s relative density exceeded that of the native soil, an increase in uplift capacity was observed. However, the effectiveness of backfilling appears to be sensitive to disturbance at the vertical excavation interface. Sloping the backfill sides to 25° allowed the failure surface to develop at the soil’s dilation angle, independent of excavation effects. These findings offer practical strategies to improve foundation efficiency and sustainability in overhead line projects.


  • Condition Monitoring of Cap and Pin Insulator String by Electric Field Mapping Using Electro-Optical Probes With FEA Model Validation

    by Fang Liu, Erwin Lopez, Ramy Afia, Andrew West, Harry McDonald, Vidyadhar Peesapati, Siniša Djurović, Ian Cotton, Khristopher Kabbabe, Stephen Mbisike, et al.

    Cap and pin insulators are widely used in electricity transmission towers in power systems and are one of their key functional elements. This paper reports on a successful application of using electric field as an index to detect and locate shorted insulator units in a cap and pin string. Electro-optical (EO) probes were used to measure the electrical field, and a six-axis robotic arm, holding the probes, enabled electrical field mapping at different spatial locations. The electric field distribution was first plotted according to the measurements performed by EO probes travelling along straight lines parallel to the string, and then a closer examination between insulator sheds was conducted to evaluate the possibility of higher accuracy locating of shorted insulator units. The measured changes in electric field distribution were compared with predictions from corresponding electrostatic finite element analysis (FEA) models, confirming the ability of locating shorted units in the string based on observation of the field spatial distribution change. The electric field monitoring system was also further developed to achieve operator-free and automated data acquisition and recording. The reported methodology exhibits promising potential in live condition monitoring of insulator strings in high voltage (HV) towers.


  • Open Access

    Improved uplift capacity design for overhead line equipment in granular soils

    by Michael John Brown, Craig Davidson, Charlie John Shepherd, Stuart Martin Flint, Stephen Mbisike

    With the transition to greater use of renewable energy resources and the growing demand for electricity, countries such as the UK are seeing considerable investment, expansion and upgrading of their energy transmission infrastructure. Overhead line equipment structures in the UK typically have pad and column or pyramidal foundations, with the critical loading case being tensile uplift. The design of new foundations and reassessment of existing structures often relies on simplistic and conservative design approaches where efficient design is key to minimising material use and carbon dioxide footprint. Both centrifuge testing and three-dimensional finite-element analysis were used to investigate and verify more efficient uplift design procedures. In addition, a centrifuge modelling technique was used to investigate a more realistic construction procedure that incorporated soil backfilling as an improvement over wished-in-place simulation. This work has shown that current frustrum based methods are conservative and may lead to unnecessary upgrading of existing structures. Other empirically based approaches generally overpredict capacity by a significant amount and may be unsafe. Investigations of recently adopted design approaches where failure mechanisms were linked to the soil’s dilation angle yielded much better performance.


  • Open Access

    Amplification of pyroelectric device with WSe2 field effect transistor and ferroelectric gating

    by Stephen C. Mbisike, Lutz Eckart, John W. Phair, Peter Lomax, Rebecca Cheung

    A WSe2 field effect transistor integrated with a lead zirconium titanate (PZT) pyroelectric device has been designed, fabricated, and tested and is described as the integrated pyroelectric device. The integrated device has been compared to a standalone pyroelectric device, which consists of PZT sandwiched between platinum electrodes. A pyroelectric coefficient of 1.755 × 10−4 C/m2K has been realized for our thin-film PZT (650 nm). The integrated device amplifies the output of the standalone device by over ten orders of magnitude as the current density calculated for the devices is 16 nA/mm2 and 1 nA/mm2, respectively. The interplay between the pyro- and ferro-induced polarization of the integrated device has been studied. From our observations, the ferroelectric gating controls directly the drain-source current output of the integrated device, showing anti-clockwise hysteresis behavior. The device shows promise for application in infrared sensing.