Michael John Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael John Brown has a total of 423 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Adam Knappett
Department of Engineering Science, University of Oxford, (formerly University of Dundee), Oxford, UK
30 shared publications - Andrew Brennan
School of Science and Engineering, University of Dundee, Dundee, UK
16 shared publications - William Michael Coombs
Department of Engineering, Durham University, Durham, UK
16 shared publications - Yaseen Umar Sharif
Research Associate, School of Science and Engineering, University of Dundee, Dundee, UK: )
14 shared publications - Benjamin Cerfontaine
University of Southampton * Engineering and Physical Sciences Southampton
12 shared publications - Craig Davidson
Geotechnical Facilities Manager, School of Science and Engineering, University of Dundee, Dundee, UK
12 shared publications
Latest Publications
- Open Access
- 7 July 2026
- Published by Elsevier in Ocean Engineering
- Vol. 364
Drag embedment anchor penetration in layered sands and through cable and pipeline trenches
- 7 July 2026
- Published by Elsevier in Ocean Engineering
- Vol. 364
Open AccessDrag embedment anchor penetration in layered sands and through cable and pipeline trenches
- 30 June 2026
- Published by Emerald Publishing in Géotechnique
- Vol. 76 (6) , 842-855
Predicting the installation of pushed-in cluster piles for offshore wind foundations in sand
The pushed-in cluster pile concept consists of the cyclic jacking of four closely spaced piles in a sequence, such that one pile is jacked while the other three act as reaction piles, enabling deeper embedment than static weight alone can provide. The method offers a low-noise alternative for offshore wind foundation installation, addressing increasing environmental constraints and the need for scalable solutions. This study presents a comprehensive experimental investigation using 38 centrifuge tests to evaluate the performance of closely spaced pile clusters jacked into sand. Key mechanisms such as pile plugging, enhanced pile penetration resistance and installation efficiency are examined, while an optimum installation sequence is determined. A novel cone penetration test-based predictive framework is developed and validated, linking single pile resistance to cluster performance through installation efficiency. The model accurately forecasts refusal depth and enables optimisation of pile diameter, spacing and tool weight. Results demonstrate that pushed-in pile clusters can achieve up to 5 times greater penetration than static embedment, offering a promising foundation solution for offshore wind applications with reduced environmental impact.
- 30 June 2026
- Published by Emerald Publishing in Géotechnique
- Vol. 76 (6) , 842-855
Predicting the installation of pushed-in cluster piles for offshore wind foundations in sand
The pushed-in cluster pile concept consists of the cyclic jacking of four closely spaced piles in a sequence, such that one pile is jacked while the other three act as reaction piles, enabling deeper embedment than static weight alone can provide. The method offers a low-noise alternative for offshore wind foundation installation, addressing increasing environmental constraints and the need for scalable solutions. This study presents a comprehensive experimental investigation using 38 centrifuge tests to evaluate the performance of closely spaced pile clusters jacked into sand. Key mechanisms such as pile plugging, enhanced pile penetration resistance and installation efficiency are examined, while an optimum installation sequence is determined. A novel cone penetration test-based predictive framework is developed and validated, linking single pile resistance to cluster performance through installation efficiency. The model accurately forecasts refusal depth and enables optimisation of pile diameter, spacing and tool weight. Results demonstrate that pushed-in pile clusters can achieve up to 5 times greater penetration than static embedment, offering a promising foundation solution for offshore wind applications with reduced environmental impact.
- Open Access
- 12 June 2026
- Published by Emerald Publishing in International Journal of Physical Modelling in Geotechnics
- p. 1-18
Large-scale uplift tests to improve design of pad foundations for overhead line equipment
This paper presents the results of large-scale uplift tests on pad foundations conducted at the UKCRIC Soil-Foundation–Structure Interaction Laboratory at the University of Bristol, simulating conditions relevant to overhead electrical line infrastructure. Pad foundations with a 1 m × 1 m footprint and different geometries were embedded at depths of up to 2 m in manually compacted dry sand. The results complement and validate previous centrifuge tests, and numerical modelling studies aimed at improving current foundation design practices. They confirm: (i) the superiority of theoretical uplift-prediction methods that account for both the weight of the soil wedge and the frictional forces mobilised along the failure planes, both governed by soil dilation; (ii) the potential for optimising foundation geometry through chamfering to increase uplift capacity and reduce concrete volumes; and (iii) that simple projection of the uplift failure wedge to the ground surface can lead to an overestimation of the failure wedge size. Direct comparison with centrifuge tests shows close agreement in maximum uplift capacity, although some discrepancies were observed in the displacement at the peak failure state. Nevertheless, this full-scale validation provides confidence in implementing the novel design methods for pad foundations supporting overhead electrical line infrastructure.
- 12 June 2026
- Published by Emerald Publishing in International Journal of Physical Modelling in Geotechnics
- p. 1-18
Open AccessLarge-scale uplift tests to improve design of pad foundations for overhead line equipment
This paper presents the results of large-scale uplift tests on pad foundations conducted at the UKCRIC Soil-Foundation–Structure Interaction Laboratory at the University of Bristol, simulating conditions relevant to overhead electrical line infrastructure. Pad foundations with a 1 m × 1 m footprint and different geometries were embedded at depths of up to 2 m in manually compacted dry sand. The results complement and validate previous centrifuge tests, and numerical modelling studies aimed at improving current foundation design practices. They confirm: (i) the superiority of theoretical uplift-prediction methods that account for both the weight of the soil wedge and the frictional forces mobilised along the failure planes, both governed by soil dilation; (ii) the potential for optimising foundation geometry through chamfering to increase uplift capacity and reduce concrete volumes; and (iii) that simple projection of the uplift failure wedge to the ground surface can lead to an overestimation of the failure wedge size. Direct comparison with centrifuge tests shows close agreement in maximum uplift capacity, although some discrepancies were observed in the displacement at the peak failure state. Nevertheless, this full-scale validation provides confidence in implementing the novel design methods for pad foundations supporting overhead electrical line infrastructure.
- Open Access
- 30 April 2026
- Published by Elsevier in Ocean Engineering
- Vol. 358
Three-dimensional modelling of drag anchor penetration using the material point method
- 30 April 2026
- Published by Elsevier in Ocean Engineering
- Vol. 358
Open AccessThree-dimensional modelling of drag anchor penetration using the material point method
- Open Access
- 12 February 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 179 (2) , 173-186
Sustainable overhead line equipment foundations with optimised shape and backfilling
Methods to enhance the tensile capacity and optimise the design of concrete pad foundations for overhead line equipment were investigated with the aim of reducing environmental impacts and costs. Using finite-element analysis and centrifuge modelling in sand, the effects of chamfering the pad's upper edge and varying the density of the material used to backfill the excavation were explored. A 30–40° chamfered edge on the pad increased the tensile capacity by up to 40% at low embedment ratios, shifting the failure surface origin from the pad top to the bottom. The backfill density above the foundation was shown to influence the failure mechanisms. When the backfill was less dense than the native soil, vertical failure surfaces formed. Conversely, when the relative densities of both the backfill and native soil were 60% or higher, transitional shear planes emerged. When the backfill’s relative density exceeded that of the native soil, an increase in uplift capacity was observed. However, the effectiveness of backfilling appears to be sensitive to disturbance at the vertical excavation interface. Sloping the backfill sides to 25° allowed the failure surface to develop at the soil’s dilation angle, independent of excavation effects. These findings offer practical strategies to improve foundation efficiency and sustainability in overhead line projects.
- 12 February 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 179 (2) , 173-186
Open AccessSustainable overhead line equipment foundations with optimised shape and backfilling
Methods to enhance the tensile capacity and optimise the design of concrete pad foundations for overhead line equipment were investigated with the aim of reducing environmental impacts and costs. Using finite-element analysis and centrifuge modelling in sand, the effects of chamfering the pad's upper edge and varying the density of the material used to backfill the excavation were explored. A 30–40° chamfered edge on the pad increased the tensile capacity by up to 40% at low embedment ratios, shifting the failure surface origin from the pad top to the bottom. The backfill density above the foundation was shown to influence the failure mechanisms. When the backfill was less dense than the native soil, vertical failure surfaces formed. Conversely, when the relative densities of both the backfill and native soil were 60% or higher, transitional shear planes emerged. When the backfill’s relative density exceeded that of the native soil, an increase in uplift capacity was observed. However, the effectiveness of backfilling appears to be sensitive to disturbance at the vertical excavation interface. Sloping the backfill sides to 25° allowed the failure surface to develop at the soil’s dilation angle, independent of excavation effects. These findings offer practical strategies to improve foundation efficiency and sustainability in overhead line projects.
- 16 December 2025
- Published by Emerald Publishing in Géotechnique Letters
- Vol. 16 (1) , 77-81
Effect of drag rates on drag embedment anchor penetration for cable burial risk assessment
Cable burial risk assessment (CBRA) defines minimum seabed burial depth of cables to avoid interaction with towed objects that penetrate the seabed, for example, drag embedment anchors (DEA). Recent physical modelling studies have shown that model anchors dragged in dry sand may penetrate to much greater depths in loose sand than current CBRA approaches predict. As other seabed penetrating objects (e.g. pipeline ploughs) have shown velocity or rate of pull dependent behaviour in saturated soils, it is necessary to check for similar rate-dependent penetration behaviour for DEAs. This is required to verify the effect of anchor drag rates in CBRA methods and the validity of previous modelling studies that differ in their findings from current CBRA. This study used model centrifuge tests of DEAs pulled at varying rates in saturated conditions. The result show that anchor penetration depths are reduced with increasing drag rates. The results also confirm that CBRA assumptions of anchor orientation are not consistent with observed behaviour and soil penetration factors require updating. The results suggest that CBRA approaches should also consider the drag speed of the penetration event as this may vary during emergency deployment or may be much lower where a vessel drifts at anchor.
- 16 December 2025
- Published by Emerald Publishing in Géotechnique Letters
- Vol. 16 (1) , 77-81
Effect of drag rates on drag embedment anchor penetration for cable burial risk assessment
Cable burial risk assessment (CBRA) defines minimum seabed burial depth of cables to avoid interaction with towed objects that penetrate the seabed, for example, drag embedment anchors (DEA). Recent physical modelling studies have shown that model anchors dragged in dry sand may penetrate to much greater depths in loose sand than current CBRA approaches predict. As other seabed penetrating objects (e.g. pipeline ploughs) have shown velocity or rate of pull dependent behaviour in saturated soils, it is necessary to check for similar rate-dependent penetration behaviour for DEAs. This is required to verify the effect of anchor drag rates in CBRA methods and the validity of previous modelling studies that differ in their findings from current CBRA. This study used model centrifuge tests of DEAs pulled at varying rates in saturated conditions. The result show that anchor penetration depths are reduced with increasing drag rates. The results also confirm that CBRA assumptions of anchor orientation are not consistent with observed behaviour and soil penetration factors require updating. The results suggest that CBRA approaches should also consider the drag speed of the penetration event as this may vary during emergency deployment or may be much lower where a vessel drifts at anchor.
- Open Access
- 22 October 2025
- Published by Springer Nature in Acta Geotechnica
- Vol. 21 (3) , 1265-1279
The variation of large strain viscous rate effects from undrained triaxial element testing of Kaolin clay
Viscous (undrained) rate effects lead to an increase in the shear strength of fine-grained soils such as clays when sheared at high strain rates. Correct rate effect parameters are key to accurate predictions of behaviour in a range of geotechnical applications, from subsea cable ploughing and rapid load testing of piles through to numerical modelling of offshore foundation systems. The factors influencing the magnitude of rate effects are, however, still poorly understood. Through a series of 100-mm diameter high-speed undrained triaxial tests (strain rates ranging from 300 to 180,000%/hr and initial effective stresses from 300 to 1350 kPa) on Kaolin clay, this paper investigates the influence of the soil state and stress history on rate effects across a wide strain range. Viscous rate effects ranging from 10 to 16% per log cycle are observed, and the liquidity index is observed to correlate to the magnitude of the rate effects. Viscous rate effects are also shown to reduce with increasing strain level, and a model is proposed which allows the rate effect in Kaolin to be predicted accounting for both of these factors. This model is potentially useful in analytical and numerical studies.
- 22 October 2025
- Published by Springer Nature in Acta Geotechnica
- Vol. 21 (3) , 1265-1279
Open AccessThe variation of large strain viscous rate effects from undrained triaxial element testing of Kaolin clay
Viscous (undrained) rate effects lead to an increase in the shear strength of fine-grained soils such as clays when sheared at high strain rates. Correct rate effect parameters are key to accurate predictions of behaviour in a range of geotechnical applications, from subsea cable ploughing and rapid load testing of piles through to numerical modelling of offshore foundation systems. The factors influencing the magnitude of rate effects are, however, still poorly understood. Through a series of 100-mm diameter high-speed undrained triaxial tests (strain rates ranging from 300 to 180,000%/hr and initial effective stresses from 300 to 1350 kPa) on Kaolin clay, this paper investigates the influence of the soil state and stress history on rate effects across a wide strain range. Viscous rate effects ranging from 10 to 16% per log cycle are observed, and the liquidity index is observed to correlate to the magnitude of the rate effects. Viscous rate effects are also shown to reduce with increasing strain level, and a model is proposed which allows the rate effect in Kaolin to be predicted accounting for both of these factors. This model is potentially useful in analytical and numerical studies.
- 24 September 2025
- Published by Emerald Publishing in Géotechnique
- Vol. 76 (1) , 215-229
Impact of tunnel alignment on local seismic lining actions
The seismic performance of long, embedded tunnels can be significantly influenced by spatial variation in ground motion, particularly when the tunnel length approaches the wavelength of seismic waves. This study presents an integrated two-stage modelling approach to evaluate the effect of global (alignment-scale) effects on the local (lining-scale) seismic response of the 27 km circular large hadron collider (LHC) tunnel at CERN. A beam on non-linear Winkler foundation (BNWF) model is first used to simulate the effects of asynchronous wave passage and alignment curvature under three-dimensional (3D) seismic scenarios. The results reveal that asynchronous excitation induces wave-like differential displacements and non-planar forces, particularly intensified at tunnel–cavern interfaces due to stiffness contrasts. These global actions are then applied as dynamic boundary conditions in high-fidelity 3D non-linear finite-element analyses (FEA) of a critical tunnel section. The 3D FEA captures detailed local responses within the reinforced concrete lining, revealing that conventional two-dimensional plane-strain models underestimate hoop forces and overlook alignment-induced amplifications of seismic actions. The results demonstrate the necessity of accounting for alignment effects in seismic tunnel design and demonstrate the effectiveness of the proposed BNWF–FEA hybrid methodology.
- 24 September 2025
- Published by Emerald Publishing in Géotechnique
- Vol. 76 (1) , 215-229
Impact of tunnel alignment on local seismic lining actions
The seismic performance of long, embedded tunnels can be significantly influenced by spatial variation in ground motion, particularly when the tunnel length approaches the wavelength of seismic waves. This study presents an integrated two-stage modelling approach to evaluate the effect of global (alignment-scale) effects on the local (lining-scale) seismic response of the 27 km circular large hadron collider (LHC) tunnel at CERN. A beam on non-linear Winkler foundation (BNWF) model is first used to simulate the effects of asynchronous wave passage and alignment curvature under three-dimensional (3D) seismic scenarios. The results reveal that asynchronous excitation induces wave-like differential displacements and non-planar forces, particularly intensified at tunnel–cavern interfaces due to stiffness contrasts. These global actions are then applied as dynamic boundary conditions in high-fidelity 3D non-linear finite-element analyses (FEA) of a critical tunnel section. The 3D FEA captures detailed local responses within the reinforced concrete lining, revealing that conventional two-dimensional plane-strain models underestimate hoop forces and overlook alignment-induced amplifications of seismic actions. The results demonstrate the necessity of accounting for alignment effects in seismic tunnel design and demonstrate the effectiveness of the proposed BNWF–FEA hybrid methodology.
- Open Access
- 10 September 2025
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 178 (7) , 793-807
Improved uplift capacity design for overhead line equipment in granular soils
With the transition to greater use of renewable energy resources and the growing demand for electricity, countries such as the UK are seeing considerable investment, expansion and upgrading of their energy transmission infrastructure. Overhead line equipment structures in the UK typically have pad and column or pyramidal foundations, with the critical loading case being tensile uplift. The design of new foundations and reassessment of existing structures often relies on simplistic and conservative design approaches where efficient design is key to minimising material use and carbon dioxide footprint. Both centrifuge testing and three-dimensional finite-element analysis were used to investigate and verify more efficient uplift design procedures. In addition, a centrifuge modelling technique was used to investigate a more realistic construction procedure that incorporated soil backfilling as an improvement over wished-in-place simulation. This work has shown that current frustrum based methods are conservative and may lead to unnecessary upgrading of existing structures. Other empirically based approaches generally overpredict capacity by a significant amount and may be unsafe. Investigations of recently adopted design approaches where failure mechanisms were linked to the soil’s dilation angle yielded much better performance.
- 10 September 2025
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 178 (7) , 793-807
Open AccessImproved uplift capacity design for overhead line equipment in granular soils
With the transition to greater use of renewable energy resources and the growing demand for electricity, countries such as the UK are seeing considerable investment, expansion and upgrading of their energy transmission infrastructure. Overhead line equipment structures in the UK typically have pad and column or pyramidal foundations, with the critical loading case being tensile uplift. The design of new foundations and reassessment of existing structures often relies on simplistic and conservative design approaches where efficient design is key to minimising material use and carbon dioxide footprint. Both centrifuge testing and three-dimensional finite-element analysis were used to investigate and verify more efficient uplift design procedures. In addition, a centrifuge modelling technique was used to investigate a more realistic construction procedure that incorporated soil backfilling as an improvement over wished-in-place simulation. This work has shown that current frustrum based methods are conservative and may lead to unnecessary upgrading of existing structures. Other empirically based approaches generally overpredict capacity by a significant amount and may be unsafe. Investigations of recently adopted design approaches where failure mechanisms were linked to the soil’s dilation angle yielded much better performance.
- 4 July 2025
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 178 (7) , 752-767
Tensile response of screw piles with varying installation approaches in layered sand
Single or multiple helix screw piles are being considered as fast and economical foundation systems for onshore renewable energy units. These foundations may encounter distinct soil layering and need to perform under a variety of load cases. For this application, the installation and monotonic tensile load response of multiple helix screw piles in uniform and layered sands were investigated by centrifuge modelling. Standard pitch-matched and pile self-weight approaches to installation were considered. The latter is advantageous as it requires no additional vertical force during installation (minimising plant requirements), alongside improved tensile capacity and reduced installation torque. Tensile capacity could also be increased by the inclusion of additional helices, but soil properties and layering arrangement must be considered or tensile capacity may be reduced. The performance of existing tensile capacity design methods was investigated and compared with the test results. A cylindrical shearing mechanism appears appropriate for capacity prediction in the majority of layering arrangements explored. Where individual plate-bearing mechanisms dominate, a modification to an existing approach reasonably predicted tensile capacity for shallow mechanisms, while further work is required to develop reliable prediction methods for deep mechanism behaviour in layered soils.
- 4 July 2025
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
- Vol. 178 (7) , 752-767
Tensile response of screw piles with varying installation approaches in layered sand
Single or multiple helix screw piles are being considered as fast and economical foundation systems for onshore renewable energy units. These foundations may encounter distinct soil layering and need to perform under a variety of load cases. For this application, the installation and monotonic tensile load response of multiple helix screw piles in uniform and layered sands were investigated by centrifuge modelling. Standard pitch-matched and pile self-weight approaches to installation were considered. The latter is advantageous as it requires no additional vertical force during installation (minimising plant requirements), alongside improved tensile capacity and reduced installation torque. Tensile capacity could also be increased by the inclusion of additional helices, but soil properties and layering arrangement must be considered or tensile capacity may be reduced. The performance of existing tensile capacity design methods was investigated and compared with the test results. A cylindrical shearing mechanism appears appropriate for capacity prediction in the majority of layering arrangements explored. Where individual plate-bearing mechanisms dominate, a modification to an existing approach reasonably predicted tensile capacity for shallow mechanisms, while further work is required to develop reliable prediction methods for deep mechanism behaviour in layered soils.