Itsuki Iwata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Itsuki Iwata has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Takuya Sakamoto
Department of Electrical, Electronic, and Digital Science and Engineering, Graduate School of Engineering, Kyoto University, Kyoto, Japan
5 shared publications - Kimitaka Sumi
Department of Electrical, Electronic, and Digital Science and Engineering, Graduate School of Engineering, Kyoto University, Kyoto, Japan
2 shared publications - Masako Myowa
Graduate School of Education, Kyoto University, Kyoto, Japan
2 shared publications - Yuji Tanaka
Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Japan
2 shared publications - Atsushi Senju
Research Center for Child Mental Development, Hamamatsu University School of Medicine, Hamamatsu, Japan
1 shared publication Daisuke Sanematsu
Graduate School of Engineering Kyoto University Kyoto Japan
1 shared publication
Latest Publications
- Open Access
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 97094-97106
Accurate Radar-Based Heartbeat Measurement Using Higher Harmonic Components
This study proposes a radar-based heartbeat measurement method that uses the absolute value of the second derivative of the complex radar signal, rather than its phase, and the variational mode extraction method, which is a type of mode decomposition algorithm. We show that the proposed second-derivative-based approach can amplify the heartbeat component in radar signals effectively and also confirm that use of the variational mode extraction method represents an efficient way to emphasize the heartbeat component amplified via the second-derivative-based approach. We demonstrate estimation of the heart interbeat intervals using the proposed approach in combination with the topology method, which is an accurate interbeat interval estimation method. The performance of the proposed method is evaluated quantitatively using data obtained from eleven participants that were measured using a millimeter-wave radar system. When compared with conventional methods based on the phase of the complex radar signal, our proposed method can achieve higher accuracy when estimating the heart interbeat intervals; the correlation coefficient for the proposed method was increased by 0.20 and the root-mean-square error decreased by 23%.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 97094-97106
Open AccessAccurate Radar-Based Heartbeat Measurement Using Higher Harmonic Components
This study proposes a radar-based heartbeat measurement method that uses the absolute value of the second derivative of the complex radar signal, rather than its phase, and the variational mode extraction method, which is a type of mode decomposition algorithm. We show that the proposed second-derivative-based approach can amplify the heartbeat component in radar signals effectively and also confirm that use of the variational mode extraction method represents an efficient way to emphasize the heartbeat component amplified via the second-derivative-based approach. We demonstrate estimation of the heart interbeat intervals using the proposed approach in combination with the topology method, which is an accurate interbeat interval estimation method. The performance of the proposed method is evaluated quantitatively using data obtained from eleven participants that were measured using a millimeter-wave radar system. When compared with conventional methods based on the phase of the complex radar signal, our proposed method can achieve higher accuracy when estimating the heart interbeat intervals; the correlation coefficient for the proposed method was increased by 0.20 and the root-mean-square error decreased by 23%.
- Open Access
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 23156-23170
Detection and Classification of Teacher-Rated Children’s Activity Levels Using Millimeter-Wave Radar and Machine Learning: A Pilot Study in a Real Primary School Environment
Traditional assessments of children’s health and behavioral issues primarily rely on subjective evaluation by adult raters, which imposes major costs in time and human resource to the school system. This pilot study investigates the utilization of millimeter-wave radar coupled with machine learning for the objective and semi-automatic detection and classification of children’s activity levels, defined as restlessness, within a real classroom environment. Two objectives are pursued: confirming the feasibility of restlessness detection using millimeter-wave radar and applying standard machine learning method for restlessness classification. The experiment involves a nine-day observational study, using two radar systems to monitor the activities of 14 children in a primary school. Radar data analysis involves the extraction of distinctive features for restlessness detection and classification. Results indicate the successful detection of restlessness using millimeter-wave radar, demonstrating its potential to capture nuanced body movements in a privacy-protected manner. Machine learning models trained on radar data achieve a classification accuracy of 100%, outperforming other methods in terms of non-invasiveness, lack of body restraint, multi-target applications, and privacy protection. The study’s contributions extend to children, parents, and educational practitioners, emphasizing non-invasiveness, privacy protection, and evidence-based support. Despite limitations such as a short monitoring duration and a small sample size, this pilot study lays the foundation for future research in non-invasive restlessness detection using non-contact monitoring technologies. The integration of millimeter-wave radar and machine learning offers a promising avenue for efficient and ethical trait assessments in real-world educational environments, contributing to the advancement of child psychology and education. This work supports efforts for non-contact monitoring of children’s activity holding promise such as non-invasive, privacy protection, multi-targets, objective evaluation, and computer-aided screening.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 23156-23170
Open AccessDetection and Classification of Teacher-Rated Children’s Activity Levels Using Millimeter-Wave Radar and Machine Learning: A Pilot Study in a Real Primary School Environment
Traditional assessments of children’s health and behavioral issues primarily rely on subjective evaluation by adult raters, which imposes major costs in time and human resource to the school system. This pilot study investigates the utilization of millimeter-wave radar coupled with machine learning for the objective and semi-automatic detection and classification of children’s activity levels, defined as restlessness, within a real classroom environment. Two objectives are pursued: confirming the feasibility of restlessness detection using millimeter-wave radar and applying standard machine learning method for restlessness classification. The experiment involves a nine-day observational study, using two radar systems to monitor the activities of 14 children in a primary school. Radar data analysis involves the extraction of distinctive features for restlessness detection and classification. Results indicate the successful detection of restlessness using millimeter-wave radar, demonstrating its potential to capture nuanced body movements in a privacy-protected manner. Machine learning models trained on radar data achieve a classification accuracy of 100%, outperforming other methods in terms of non-invasiveness, lack of body restraint, multi-target applications, and privacy protection. The study’s contributions extend to children, parents, and educational practitioners, emphasizing non-invasiveness, privacy protection, and evidence-based support. Despite limitations such as a short monitoring duration and a small sample size, this pilot study lays the foundation for future research in non-invasive restlessness detection using non-contact monitoring technologies. The integration of millimeter-wave radar and machine learning offers a promising avenue for efficient and ethical trait assessments in real-world educational environments, contributing to the advancement of child psychology and education. This work supports efforts for non-contact monitoring of children’s activity holding promise such as non-invasive, privacy protection, multi-targets, objective evaluation, and computer-aided screening.
- Open Access
- 1 July 2024
- Published by Wiley in American Journal of Primatology
- Vol. 86 (9) , e23661
Outdoor noncontact respiratory measurements of unrestricted rhesus macaques (Macaca mulatta) using millimeter‐wave radar
Respiration is an invaluable signal that facilitates the real‐time observation of physiological dynamics. In recent years, the advancement of noncontact measurement technology has gained momentum in capturing physiological activities in natural settings. This technology is anticipated to be found not only in humans but also in nonhuman primates. Currently, the predominant noncontact approach for nonhuman animals involves measuring vital signs through subtle variations in skin color. However, this approach is limited when addressing areas of the body covered with hair or when working in outdoor settings under fluctuating sunlight. To overcome this issue, we focused on noncontact respiratory measurements using millimeter‐wave radar. Millimeter‐wave radar systems, which employ millimeter waves that can penetrate animal fur and estimate respiration‐derived periodic body motion, exhibit minimal susceptibility to sunlight interference. Thus, this method shows potential for conducting noncontact vital measurements in natural and outdoor settings. In this study, we validated a millimeter‐wave radar methodology for capturing respiration in outdoor‐housed rhesus macaques (Macaca mulatta). The radar was positioned beyond the captive enclosure and maintained at a distance >5 m from the target. Millimeter waves were transmitted to the target, and the reflected waves were used to estimate skin surface displacement associated with respiration. The results revealed periodic skin surface displacement, and the estimated respiratory rates weres within the reported range of respiratory rates for rhesus macaques. These results suggest the potential applicability of millimeter‐wave radar for noncontact respiration monitoring in outdoor‐living macaques without anesthesia or immobilization. The continued advancement of noncontact vital measurement technology will contribute to understanding primate mental and physical dynamics during their daily life.
- 1 July 2024
- Published by Wiley in American Journal of Primatology
- Vol. 86 (9) , e23661
Open AccessOutdoor noncontact respiratory measurements of unrestricted rhesus macaques (Macaca mulatta) using millimeter‐wave radar
Respiration is an invaluable signal that facilitates the real‐time observation of physiological dynamics. In recent years, the advancement of noncontact measurement technology has gained momentum in capturing physiological activities in natural settings. This technology is anticipated to be found not only in humans but also in nonhuman primates. Currently, the predominant noncontact approach for nonhuman animals involves measuring vital signs through subtle variations in skin color. However, this approach is limited when addressing areas of the body covered with hair or when working in outdoor settings under fluctuating sunlight. To overcome this issue, we focused on noncontact respiratory measurements using millimeter‐wave radar. Millimeter‐wave radar systems, which employ millimeter waves that can penetrate animal fur and estimate respiration‐derived periodic body motion, exhibit minimal susceptibility to sunlight interference. Thus, this method shows potential for conducting noncontact vital measurements in natural and outdoor settings. In this study, we validated a millimeter‐wave radar methodology for capturing respiration in outdoor‐housed rhesus macaques (Macaca mulatta). The radar was positioned beyond the captive enclosure and maintained at a distance >5 m from the target. Millimeter waves were transmitted to the target, and the reflected waves were used to estimate skin surface displacement associated with respiration. The results revealed periodic skin surface displacement, and the estimated respiratory rates weres within the reported range of respiratory rates for rhesus macaques. These results suggest the potential applicability of millimeter‐wave radar for noncontact respiration monitoring in outdoor‐living macaques without anesthesia or immobilization. The continued advancement of noncontact vital measurement technology will contribute to understanding primate mental and physical dynamics during their daily life.
- Open Access
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (3) , 1-4
Complex Number Assignment in the Topology Method for Heartbeat Interval Estimation Using Millimeter-Wave Radar
The topology method is an algorithm for accurate estimation of instantaneous heartbeat intervals using millimeter-wave radar signals. In this model, feature points are extracted from the skin displacement waveforms generated by heartbeats and a complex number is assigned to each feature point. However, these numbers have been assigned empirically and without solid justification. This study used a simplified model of displacement waveforms to predict the optimal choice of the complex number assignments to feature points corresponding to inflection points, and the validity of these numbers was confirmed using analysis of a publicly available dataset.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (3) , 1-4
Open AccessComplex Number Assignment in the Topology Method for Heartbeat Interval Estimation Using Millimeter-Wave Radar
The topology method is an algorithm for accurate estimation of instantaneous heartbeat intervals using millimeter-wave radar signals. In this model, feature points are extracted from the skin displacement waveforms generated by heartbeats and a complex number is assigned to each feature point. However, these numbers have been assigned empirically and without solid justification. This study used a simplified model of displacement waveforms to predict the optimal choice of the complex number assignments to feature points corresponding to inflection points, and the validity of these numbers was confirmed using analysis of a publicly available dataset.
- Open Access
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (11) , 1-4
Noncontact Measurement of Heartbeat of Humans and Chimpanzees Using Millimeter-Wave Radar With Topology Method
This letter proposes a method to determine the filter parameters required for the topology method, which is a radar-based noncontact method for the measurement of heart interbeat intervals. The effectiveness of the proposed method is evaluated by performing radar measurements involving both human participants and chimpanzee subjects. The proposed method is designed to enable the setting of the filter cutoff frequency to eliminate respiratory components while maintaining the higher harmonics of the heartbeat components. Measurements using a millimeter-wave radar system and a reference contact-type electrocardiogram sensor demonstrate that the smallest errors that occur when measuring heart interbeat intervals using the proposed method can be as small as 4.43 and 2.55 ms for humans and chimpanzees, respectively. These results indicate the possibility of using noncontact physiological measurements to monitor both humans and chimpanzees.
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (11) , 1-4
Open AccessNoncontact Measurement of Heartbeat of Humans and Chimpanzees Using Millimeter-Wave Radar With Topology Method
This letter proposes a method to determine the filter parameters required for the topology method, which is a radar-based noncontact method for the measurement of heart interbeat intervals. The effectiveness of the proposed method is evaluated by performing radar measurements involving both human participants and chimpanzee subjects. The proposed method is designed to enable the setting of the filter cutoff frequency to eliminate respiratory components while maintaining the higher harmonics of the heartbeat components. Measurements using a millimeter-wave radar system and a reference contact-type electrocardiogram sensor demonstrate that the smallest errors that occur when measuring heart interbeat intervals using the proposed method can be as small as 4.43 and 2.55 ms for humans and chimpanzees, respectively. These results indicate the possibility of using noncontact physiological measurements to monitor both humans and chimpanzees.