KSKimitaka Sumi

Kimitaka Sumi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kimitaka Sumi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation for Noncontact Radar-Based Respiratory Measurement Using Depth Camera-Derived Human 3-D Models

    by Kimitaka Sumi, Takuya Sakamoto

    In this study, a simulation framework is proposed that serves as a foundation for improving the accuracy of human vital sensing using millimeter-wave radar. Unlike conventional approaches that rely on simplified models of body geometry or displacement, the proposed method simulates the signals received by frequency-modulated continuous-wave radar during respiratory monitoring using realistic human body shapes and motions acquired via a depth camera. Furthermore, the proposed method enables fast data generation by using time-averaged human body geometry and discrete scattering centers. Experiments were conducted on six participants under varying conditions, including varying target distances, seating orientations, and radar types, with simultaneous acquisition from radar and the depth camera. Relative to conventional model-based methods, the proposed technique achieved improvements of 7.6%, 58.7%, and 3.7% in the correlation coefficients of radar images, displacements, and spectrograms, respectively. This work contributes to the generation of radar-based physiological datasets through simulation and enhances our understanding of factors that affect the accuracy of non-contact sensing.

  • Open Access

    Radar-Based Estimation of Heart Interbeat Interval Using Waveform Features and a Probabilistic Model With Latent Variables

    by Kimitaka Sumi, Takuya Sakamoto

    This letter proposes a millimeter-wave radar sensing system for adaptive measurement of the heart interbeat interval under diverse measurement environments. Millimeter-wave radar provides high-resolution sensing of micrometer-scale heartbeat-induced skin motion. However, the signal-to-noise ratio of the heartbeat component contained in the measured displacement varies substantially across postures and individuals, making it difficult to maintain stable measurement performance. To address this challenge, we introduce a probabilistic sensing model for heartbeat-induced micro-motions with heteroscedastic Gaussian process regression-based compensation method. This approach adaptively stabilizes the radar-based heartbeat measurement even in diverse measurement conditions. Experiments with five participants in three seating orientations demonstrated that the proposed sensing method reduced heart interbeat interval error by 63.3%, reduced heart rate error by 60.1%, and improved heart rate measurement accuracy by 21.2 points compared with a conventional radar-based measurement method.

  • Open Access

    Accurate Radar-Based Heartbeat Measurement Using Higher Harmonic Components

    by Itsuki Iwata, Kimitaka Sumi, Yuji Tanaka, Takuya Sakamoto

    This study proposes a radar-based heartbeat measurement method that uses the absolute value of the second derivative of the complex radar signal, rather than its phase, and the variational mode extraction method, which is a type of mode decomposition algorithm. We show that the proposed second-derivative-based approach can amplify the heartbeat component in radar signals effectively and also confirm that use of the variational mode extraction method represents an efficient way to emphasize the heartbeat component amplified via the second-derivative-based approach. We demonstrate estimation of the heart interbeat intervals using the proposed approach in combination with the topology method, which is an accurate interbeat interval estimation method. The performance of the proposed method is evaluated quantitatively using data obtained from eleven participants that were measured using a millimeter-wave radar system. When compared with conventional methods based on the phase of the complex radar signal, our proposed method can achieve higher accuracy when estimating the heart interbeat intervals; the correlation coefficient for the proposed method was increased by 0.20 and the root-mean-square error decreased by 23%.


  • Open Access

    Complex Number Assignment in the Topology Method for Heartbeat Interval Estimation Using Millimeter-Wave Radar

    by Yuji Tanaka, Kimitaka Sumi, Itsuki Iwata, Takuya Sakamoto

    The topology method is an algorithm for accurate estimation of instantaneous heartbeat intervals using millimeter-wave radar signals. In this model, feature points are extracted from the skin displacement waveforms generated by heartbeats and a complex number is assigned to each feature point. However, these numbers have been assigned empirically and without solid justification. This study used a simplified model of displacement waveforms to predict the optimal choice of the complex number assignments to feature points corresponding to inflection points, and the validity of these numbers was confirmed using analysis of a publicly available dataset.