Douglas Jackson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Douglas Jackson has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- John Naber
University of Louisville, Louisville, KY, USA
2 shared publications - Andriy Sherehiy
Louisville Automation and Robotics Research Institute, University of Louisville, 2210 S. Brook St., Louisville, KY 40208
1 shared publication - Dan O. Popa
Louisville Automation Research and Robotics Institute (LARRI), University of Louisville, Louisville, KY 40208, USA
1 shared publication - Daniel Sills
Louisville Automation and Robotics Research Institute, University of Louisville, 2210 S. Brook St., Louisville, KY 40208
1 shared publication - Deborah Ruth Yoder-Himes
Department of Biology, University of Louisville
1 shared publication - Dilan Ratnayake
Electrical and Computer Engineering, University of Louisville, 2210 S. Brook St., Louisville, KY 40208
1 shared publication
Latest Publications
- 21 November 2024
- Published by ASME International in Journal of Micro and Nano Science and Engineering
- Vol. 13 (1) , 1-37
Aerosol Jet and Inkjet Printing Methods for Die-Level Packaging of Custom MEMS Devices
In this study, we propose an alternative, low-cost, packaging method using both inkjet and aerosol jet printing (AJP) to fabricate functional interconnects for custom die-level packages assembled on printed circuit boards (PCBs). Our process involves the manufacturing of a stacked structure with insulating and conducting layers, fabricated using inkjet and aerosol jet printing, respectively. In the first part of the study, we characterized UV adhesive deposition on the standard resin-coated PCB to acquire the optimal parameters necessary for the fabrication of the insulating layer with thicknesses around 100 μm. In the second part of our study, we developed a precise method for printing silver conducting lines using an aerosol jet printer, enabling the realization of structures with features as small as 50 μm on nonplanar surfaces. The insulating part of the microelectromechanical systems (MEMS)/PCB structure serves as a ramp ensuring continuity of the aerosol jet printed connection between the PCB and the Si die. A 1 cm × 1 cm Si chip with a custom MEMS microrobot was used to demonstrate the feasibility and flexibility of our approach in practice. After fabrication, we evaluated the interconnects for conductivity and repeatability. The packaging and inspection process was carried out using Nexus, a unique robotic system integrating additive manufacturing, robotic transport, and metrology. The results show that we successfully fabricated printed interconnects between copper PCB pads and Si die cleanroom fabricated gold pads, while electrical characterization revealed resistances in the range of 1–10 Ω. Our approach can be utilized in the manufacturing of electrical interconnects for custom devices on different substrates, including traditional and flexible PCBs. Furthermore, the applied printing techniques enable the use of other insulating or conducting inks and the formation of structures of custom geometries across a wide range of scales—20 μm to 1 mm.
- 21 November 2024
- Published by ASME International in Journal of Micro and Nano Science and Engineering
- Vol. 13 (1) , 1-37
Aerosol Jet and Inkjet Printing Methods for Die-Level Packaging of Custom MEMS Devices
In this study, we propose an alternative, low-cost, packaging method using both inkjet and aerosol jet printing (AJP) to fabricate functional interconnects for custom die-level packages assembled on printed circuit boards (PCBs). Our process involves the manufacturing of a stacked structure with insulating and conducting layers, fabricated using inkjet and aerosol jet printing, respectively. In the first part of the study, we characterized UV adhesive deposition on the standard resin-coated PCB to acquire the optimal parameters necessary for the fabrication of the insulating layer with thicknesses around 100 μm. In the second part of our study, we developed a precise method for printing silver conducting lines using an aerosol jet printer, enabling the realization of structures with features as small as 50 μm on nonplanar surfaces. The insulating part of the microelectromechanical systems (MEMS)/PCB structure serves as a ramp ensuring continuity of the aerosol jet printed connection between the PCB and the Si die. A 1 cm × 1 cm Si chip with a custom MEMS microrobot was used to demonstrate the feasibility and flexibility of our approach in practice. After fabrication, we evaluated the interconnects for conductivity and repeatability. The packaging and inspection process was carried out using Nexus, a unique robotic system integrating additive manufacturing, robotic transport, and metrology. The results show that we successfully fabricated printed interconnects between copper PCB pads and Si die cleanroom fabricated gold pads, while electrical characterization revealed resistances in the range of 1–10 Ω. Our approach can be utilized in the manufacturing of electrical interconnects for custom devices on different substrates, including traditional and flexible PCBs. Furthermore, the applied printing techniques enable the use of other insulating or conducting inks and the formation of structures of custom geometries across a wide range of scales—20 μm to 1 mm.
- Open Access
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 198-199
Development of a Custom Wrist Wearable for Use in Nursing Homes
The wearable technology market is consistently growing. Many devices are being developed for commercial applications and individual use incorporating sensors that measure vital information such as heart rate, blood oxygen, and temperature. These general market application devices lack optimization for some target markets such as nursing home patients. For this application, optimized hardware and software are required to extract meaningful data to improve outcomes on a wide scale. Patient-maintained devices are not a practical option; thus, the task of charging and setup is placed on Certified Nursing Assistants (CNAs). These wearables are wireless sensors without user displays and controls. Typical sensing devices consist of Inertial Measurement Units (IMUs), temperature sensors, and photoplethysmography (PPG) sensors for heart rate (HR) and SpO2 with wireless communication and a rechargeable battery. The key objectives for specific use in nursing homes are optimal hardware design for measurement and power efficiency and firmware for the measurement scenarios present in the nursing home. An overview of HR, SpO2, IMU, and temperature measurements will be presented with unique considerations for the target population. The battery life of this wrist wearable was estimated to last 79 days.
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 198-199
Open AccessDevelopment of a Custom Wrist Wearable for Use in Nursing Homes
The wearable technology market is consistently growing. Many devices are being developed for commercial applications and individual use incorporating sensors that measure vital information such as heart rate, blood oxygen, and temperature. These general market application devices lack optimization for some target markets such as nursing home patients. For this application, optimized hardware and software are required to extract meaningful data to improve outcomes on a wide scale. Patient-maintained devices are not a practical option; thus, the task of charging and setup is placed on Certified Nursing Assistants (CNAs). These wearables are wireless sensors without user displays and controls. Typical sensing devices consist of Inertial Measurement Units (IMUs), temperature sensors, and photoplethysmography (PPG) sensors for heart rate (HR) and SpO2 with wireless communication and a rechargeable battery. The key objectives for specific use in nursing homes are optimal hardware design for measurement and power efficiency and firmware for the measurement scenarios present in the nursing home. An overview of HR, SpO2, IMU, and temperature measurements will be presented with unique considerations for the target population. The battery life of this wrist wearable was estimated to last 79 days.
- Open Access
- 17 November 2021
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 132 (3) , 1856-1865
Bactericidal effects of high-energy visible light on common otitis media pathogens
Aims This study assessed the use of high-energy, visible light on the survival rates of three bacteria commonly found in middle ear infections (i.e. otitis media; Streptococcus pneumoniae, Moraxella catarrhalis and Haemophilus influenzae). Method and Results Bacteria were cultured and then subjected to a single, 4-h treatment of 405 nm wavelength light at two different intensities. All three bacteria species were susceptible to the light at clinically significant rates (>99.9% reduction). Bacteria were susceptible to the high-energy visible (HEV) light in a dose-dependent manner (lower survival rates with increased intensity and duration of exposure). Conclusions The results suggest that HEV light may provide a non-surgical, non-pharmaceutical approach to the therapeutic treatment of otitis media. Significance an Impact of the Study Given the growing concerns surrounding antibiotic resistance, this study demonstrates a rapid, alternative method for effective inactivation of bacterial pathogens partly responsible for instances of otitis media.
- 17 November 2021
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 132 (3) , 1856-1865
Open AccessBactericidal effects of high-energy visible light on common otitis media pathogens
Aims This study assessed the use of high-energy, visible light on the survival rates of three bacteria commonly found in middle ear infections (i.e. otitis media; Streptococcus pneumoniae, Moraxella catarrhalis and Haemophilus influenzae). Method and Results Bacteria were cultured and then subjected to a single, 4-h treatment of 405 nm wavelength light at two different intensities. All three bacteria species were susceptible to the light at clinically significant rates (>99.9% reduction). Bacteria were susceptible to the high-energy visible (HEV) light in a dose-dependent manner (lower survival rates with increased intensity and duration of exposure). Conclusions The results suggest that HEV light may provide a non-surgical, non-pharmaceutical approach to the therapeutic treatment of otitis media. Significance an Impact of the Study Given the growing concerns surrounding antibiotic resistance, this study demonstrates a rapid, alternative method for effective inactivation of bacterial pathogens partly responsible for instances of otitis media.