Yoshiyuki Ishimori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshiyuki Ishimori has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Masahiko Monma
Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Kashiwa, Japan
8 shared publicationsHiraku Kawamura
Department of Radiological Technology, Faculty of Health Science, Tsukuba International University, 6-20-1 Manabe, Tsuchiura, Ibaraki, 300-0051, Japan
4 shared publicationsAkira Hiraga
Radiology Center. Kyoto University Hospital
1 shared publicationHajime Saitou
Department of Radiological Technology, Tsukuba Medical Center Hospital
1 shared publicationHidemasa Uematsu
Department of Radiology, Faculty of Medical Science, University of Fukui
1 shared publicationHideyuki Hayakawa
Department of Forensic Medicine, Tsukuba Medical Examiner’s Office
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by Medknow in Journal of Medical Physics
- Vol. 47 (1) , 93-98
Fast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence
Radiofrequency (RF) field (B1) mapping by combining the double-angle method (DAM) and T1 correction was investigated. The signal intensities S1 and S2 acquired by flip angle (FA) α and double FA 2α at short repetition time (TR) were converted to a signal intensity at TR=∞ by T1 correction. Then, these were used for DAM calculation. The T1 values are measured from two different images acquired with different TRs based on the saturation recovery (SR) method preliminarily. The effects of imaging parameters for T1 estimation and measured FA were investigated using CuSO4-doped water phantoms. A two-dimensional gradient echo type echo planar imaging pulse sequence was used. T1 values obtained by the 2-SR method were underestimated compared to the multipoint inversion recovery method. FA error was less than 5% when the appropriate imaging parameters were used. The acquisition time could be shortened to under 25 s by the use of T1-corrected DAM.
- 1 January 2022
- Published by Medknow in Journal of Medical Physics
- Vol. 47 (1) , 93-98
Open AccessFast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence
Radiofrequency (RF) field (B1) mapping by combining the double-angle method (DAM) and T1 correction was investigated. The signal intensities S1 and S2 acquired by flip angle (FA) α and double FA 2α at short repetition time (TR) were converted to a signal intensity at TR=∞ by T1 correction. Then, these were used for DAM calculation. The T1 values are measured from two different images acquired with different TRs based on the saturation recovery (SR) method preliminarily. The effects of imaging parameters for T1 estimation and measured FA were investigated using CuSO4-doped water phantoms. A two-dimensional gradient echo type echo planar imaging pulse sequence was used. T1 values obtained by the 2-SR method were underestimated compared to the multipoint inversion recovery method. FA error was less than 5% when the appropriate imaging parameters were used. The acquisition time could be shortened to under 25 s by the use of T1-corrected DAM.
- 19 June 2018
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 11 (3) , 345-352
Wide slab is useful for routine quality control of MRI slice thickness
Although slice thickness accuracy is important for the performance of magnetic resonance imaging systems, long scan times are required to perform reliable measurements. Inclined slabs and wedges are conventionally used as test devices to obtain slice profiles. In this study, a novel dedicated device with a widened slab was created, and its efficacy was compared with that of a conventional wedge. The signal-to-noise ratio (SNR) of the profile and the coefficient of variation (CV) of the measured slice thickness were measured. Wide slab usage showed sufficient SNR by averaging multiple profile lines, even with single acquisition. Therefore, it is possible to substantially shorten the measurement time. When ≥ 20 lines were averaged, CV was < 1%. Furthermore, a 200-mm slab width enabled evaluation of the positional dependence of slice thickness in a single imaging. Thus, quality control of MRI slice thickness can be easily implemented with this device.
- 19 June 2018
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 11 (3) , 345-352
Wide slab is useful for routine quality control of MRI slice thickness
Although slice thickness accuracy is important for the performance of magnetic resonance imaging systems, long scan times are required to perform reliable measurements. Inclined slabs and wedges are conventionally used as test devices to obtain slice profiles. In this study, a novel dedicated device with a widened slab was created, and its efficacy was compared with that of a conventional wedge. The signal-to-noise ratio (SNR) of the profile and the coefficient of variation (CV) of the measured slice thickness were measured. Wide slab usage showed sufficient SNR by averaging multiple profile lines, even with single acquisition. Therefore, it is possible to substantially shorten the measurement time. When ≥ 20 lines were averaged, CV was < 1%. Furthermore, a 200-mm slab width enabled evaluation of the positional dependence of slice thickness in a single imaging. Thus, quality control of MRI slice thickness can be easily implemented with this device.
- Open Access
- 28 April 2016
- Published by Sciedu Press in Journal of Biomedical Graphics and Computing
- Vol. 6 (2) , p7
Evaluation of magnetic field homogeneity using in-out signal cycle mapping in gradient recalled echo images of a mixed water/oil phantom as a rough indication for daily quality control
Objective: Magnetic field (B0) homogeneity is important for the performance of a magnetic resonance imaging (MRI) system. Traditionally, B0 homogeneity was measured using the spectral peak or phase-mapping methods. However, these procedures are not generally accessible to the MRI operator and are rarely performed routinely. This study proposes a novel method for measuring B0 homogeneity that can be implemented in daily quality control (QC). Methods: When a uniformly mixed water/oil phantom was imaged using a gradient recalled echo (GRE) pulse sequence, the signal intensity dynamically changed with echo time (TE). From this, the resonant frequency was calculated with a simplex curve-fitting algorithm on a pixel-by-pixel basis. The standard deviation of resonant frequency (SD) was used as the index of B0 homogeneity. The appropriate TE pattern and feasibility of B0 homogeneity evaluation were examined. Results: Over seven TEs (choosing nominal in-phase, out-phase, and the midpoints of both) were required to measure stable SD in a 1.5-T scanner. As B0 homogeneity worsened, the SD became larger at the off-center position. Although a positive correlation was observed with the width of the spectral peak obtained by the phase-difference method, the SD value was about 5 × 104 times greater. Therefore, SD can be used only as an index of B0 homogeneity. Similar results were obtained using a 0.3-T scanner. A map and SD can be obtained by acquiring several GRE images of a water/oil mixed phantom within a few minutes. Conclusions: In-out signal cycle mapping can be easily implemented for daily QC in all MRI scanners.
- 28 April 2016
- Published by Sciedu Press in Journal of Biomedical Graphics and Computing
- Vol. 6 (2) , p7
Open AccessEvaluation of magnetic field homogeneity using in-out signal cycle mapping in gradient recalled echo images of a mixed water/oil phantom as a rough indication for daily quality control
Objective: Magnetic field (B0) homogeneity is important for the performance of a magnetic resonance imaging (MRI) system. Traditionally, B0 homogeneity was measured using the spectral peak or phase-mapping methods. However, these procedures are not generally accessible to the MRI operator and are rarely performed routinely. This study proposes a novel method for measuring B0 homogeneity that can be implemented in daily quality control (QC). Methods: When a uniformly mixed water/oil phantom was imaged using a gradient recalled echo (GRE) pulse sequence, the signal intensity dynamically changed with echo time (TE). From this, the resonant frequency was calculated with a simplex curve-fitting algorithm on a pixel-by-pixel basis. The standard deviation of resonant frequency (SD) was used as the index of B0 homogeneity. The appropriate TE pattern and feasibility of B0 homogeneity evaluation were examined. Results: Over seven TEs (choosing nominal in-phase, out-phase, and the midpoints of both) were required to measure stable SD in a 1.5-T scanner. As B0 homogeneity worsened, the SD became larger at the off-center position. Although a positive correlation was observed with the width of the spectral peak obtained by the phase-difference method, the SD value was about 5 × 104 times greater. Therefore, SD can be used only as an index of B0 homogeneity. Similar results were obtained using a 0.3-T scanner. A map and SD can be obtained by acquiring several GRE images of a water/oil mixed phantom within a few minutes. Conclusions: In-out signal cycle mapping can be easily implemented for daily QC in all MRI scanners.
- Open Access
- 1 January 2014
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 13 (2) , 67-72
Optimization of Inversion Time for Postmortem Short-tau Inversion Recovery (STIR) MR Imaging
Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after confirmation of death and measured T1 values of areas of subcutaneous fat with relaxation time maps. Rectal temperature (RT) measured immediately after PMMR ranged from 6 to 31°C. We used Pearson's correlation coefficient to analyze the relationship between T1 and relaxation time (RT). We compared STIR images from 4 cadavers acquired with a TI commonly used in the living body and another TI calculated from the linear regression of T1 and RT. T1 values of subcutaneous fat ranged from 89.4 to 182.2 ms. There was a strong, positive, and significant correlation between T1 and RT (r = 0.91, P < 0.0001). The regression expression for the relationship was T1 = 2.6*RT + 90 at a field strength of 1.5T. The subcutaneous fat signal was suppressed more effectively with the optimized TI. The T1 value of subcutaneous fat in PMMR correlates linearly with body temperature. Using this correlation to determine TI, fat suppression with PMMR STIR imaging can be easily improved.
- 1 January 2014
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 13 (2) , 67-72
Open AccessOptimization of Inversion Time for Postmortem Short-tau Inversion Recovery (STIR) MR Imaging
Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after confirmation of death and measured T1 values of areas of subcutaneous fat with relaxation time maps. Rectal temperature (RT) measured immediately after PMMR ranged from 6 to 31°C. We used Pearson's correlation coefficient to analyze the relationship between T1 and relaxation time (RT). We compared STIR images from 4 cadavers acquired with a TI commonly used in the living body and another TI calculated from the linear regression of T1 and RT. T1 values of subcutaneous fat ranged from 89.4 to 182.2 ms. There was a strong, positive, and significant correlation between T1 and RT (r = 0.91, P < 0.0001). The regression expression for the relationship was T1 = 2.6*RT + 90 at a field strength of 1.5T. The subcutaneous fat signal was suppressed more effectively with the optimized TI. The T1 value of subcutaneous fat in PMMR correlates linearly with body temperature. Using this correlation to determine TI, fat suppression with PMMR STIR imaging can be easily improved.
- 24 May 2013
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (2) , 461-466
Feasibility of MR perfusion-weighted imaging by use of a time-spatial labeling inversion pulse
- 24 May 2013
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 6 (2) , 461-466
Feasibility of MR perfusion-weighted imaging by use of a time-spatial labeling inversion pulse
- 1 December 2010
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 4 (1) , 78-83
Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression
Time-spatial labeling inversion pulse (time-SLIP), which is a technique of nonenhanced magnetic resonance angiography (MRA) based on arterial spin labeling (ASL), is used in various situations. Although subtraction between the images obtained with and without ASL is usually employed in cerebral time-SLIP MRA, to reduce the imaging time, dual inversion recovery (IR) has been applied for suppression of the background signals in this study. Appropriate timings for the 1st IR, 2nd IR, and the interval of data acquisition were investigated using computer simulation and a phantom experiment. With a short interval of data acquisition, the visibility of the simulated vessel was inadequate because replacement of the suppressed flow was insufficient. With a long interval of data acquisition, the contrast between the vessel and background was reduced. The reasons for this appeared to be the following: the longitudinal magnetization of the replaced flow is reduced because of the prolonged 2nd inversion time, causing a mismatch of the null point between the calculated and the actual values to become prominent. As a result, 3-4 s seemed to be an appropriate interval for data acquisition. Sufficient angiographic information could be obtained by use of dual IR background suppression in a volunteer study. With this technique, cerebral time-SLIP MRA can be performed in half of the imaging time required with the conventional subtraction technique.
- 1 December 2010
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 4 (1) , 78-83
Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression
Time-spatial labeling inversion pulse (time-SLIP), which is a technique of nonenhanced magnetic resonance angiography (MRA) based on arterial spin labeling (ASL), is used in various situations. Although subtraction between the images obtained with and without ASL is usually employed in cerebral time-SLIP MRA, to reduce the imaging time, dual inversion recovery (IR) has been applied for suppression of the background signals in this study. Appropriate timings for the 1st IR, 2nd IR, and the interval of data acquisition were investigated using computer simulation and a phantom experiment. With a short interval of data acquisition, the visibility of the simulated vessel was inadequate because replacement of the suppressed flow was insufficient. With a long interval of data acquisition, the contrast between the vessel and background was reduced. The reasons for this appeared to be the following: the longitudinal magnetization of the replaced flow is reduced because of the prolonged 2nd inversion time, causing a mismatch of the null point between the calculated and the actual values to become prominent. As a result, 3-4 s seemed to be an appropriate interval for data acquisition. Sufficient angiographic information could be obtained by use of dual IR background suppression in a volunteer study. With this technique, cerebral time-SLIP MRA can be performed in half of the imaging time required with the conventional subtraction technique.
- 1 November 2009
- Published by SAGE Publications in Acta Radiologica
- Vol. 50 (9) , 1027-1034
Artifact reduction of susceptibility-weighted imaging using a short-echo phase mask
Background: Susceptibility-weighted imaging (SWI) is utilized in magnetic resonance (MR) venography and other applications, but can include artifacts caused by the phase-masking process. Purpose: To demonstrate risks of filter processes used in making phase masks for SWI, and to propose a simple method for reducing artifacts. Material and Methods: Phase linearity related to echo time (TE) was evaluated for the original phase and high-pass-filtered phase using a CuSO4-doped water phantom. Effect of filter size of the Hanning window and background homogeneity were also evaluated in a phantom study. Use of a phase mask generated by data with differing magnitudes of TE was attempted in a human study. Shorter TE was used for making the phase mask, and the number of multiplications was increased. As short and long TEs were necessary simultaneously for phase mask and T2* contrast, a dual-echo technique was used. Results: Linearity of TE and phase value collapsed, and an unexpected negative phase appeared in the high-pass-filtered phase. Using a short-TE phase mask, phase-aliasing artifacts were reduced and visibility of deep veins was equivalent to that under conventional methods with an increased number of multiplications. Conclusion: Use of a short-echo phase mask in SWI is useful for reducing artifacts.
- 1 November 2009
- Published by SAGE Publications in Acta Radiologica
- Vol. 50 (9) , 1027-1034
Artifact reduction of susceptibility-weighted imaging using a short-echo phase mask
Background: Susceptibility-weighted imaging (SWI) is utilized in magnetic resonance (MR) venography and other applications, but can include artifacts caused by the phase-masking process. Purpose: To demonstrate risks of filter processes used in making phase masks for SWI, and to propose a simple method for reducing artifacts. Material and Methods: Phase linearity related to echo time (TE) was evaluated for the original phase and high-pass-filtered phase using a CuSO4-doped water phantom. Effect of filter size of the Hanning window and background homogeneity were also evaluated in a phantom study. Use of a phase mask generated by data with differing magnitudes of TE was attempted in a human study. Shorter TE was used for making the phase mask, and the number of multiplications was increased. As short and long TEs were necessary simultaneously for phase mask and T2* contrast, a dual-echo technique was used. Results: Linearity of TE and phase value collapsed, and an unexpected negative phase appeared in the high-pass-filtered phase. Using a short-TE phase mask, phase-aliasing artifacts were reduced and visibility of deep veins was equivalent to that under conventional methods with an increased number of multiplications. Conclusion: Use of a short-echo phase mask in SWI is useful for reducing artifacts.
- 30 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 89-94
Fat quantification by use of phase change in dual-echo magnetic resonance imaging
The demand for measurement of visceral fat in medical checkups is increasing because of attention to central obesity. Computed tomography is widely used for this purpose, but carries risks associated with radiation exposure. Fast imaging with a dual-echo technique acquiring water and fat signals both in-phase and out-of-phase using magnetic resonance imaging is desirable, but not all scanners are capable of this technique. We tried to quantify fat content by using a dual-echo gradient echo pulse sequence with an arbitrary echo time (TE) set. We calculated the phase change during the TE interval and extracted the region of fat by threshold processing. Variations in the precision of counting fat pixels caused by differences between TE1 and TE2 were measured in phantom experiments. We then evaluated the validity of this method by examination of a volunteer. The phantom study showed a large error when the TE interval was a multiple of the in-phase time for fat and water, and the error increased according to the prolongation of the TE. In the human study, phase wrapping readily occurred in the phase-change image. However, the region of fat was easily extracted with high-pass filtering. The fat signal can also be extracted by use of scanners that cannot be set simultaneously to in-phase and out-of-phase TE.
- 30 November 2007
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 1 (1) , 89-94
Fat quantification by use of phase change in dual-echo magnetic resonance imaging
The demand for measurement of visceral fat in medical checkups is increasing because of attention to central obesity. Computed tomography is widely used for this purpose, but carries risks associated with radiation exposure. Fast imaging with a dual-echo technique acquiring water and fat signals both in-phase and out-of-phase using magnetic resonance imaging is desirable, but not all scanners are capable of this technique. We tried to quantify fat content by using a dual-echo gradient echo pulse sequence with an arbitrary echo time (TE) set. We calculated the phase change during the TE interval and extracted the region of fat by threshold processing. Variations in the precision of counting fat pixels caused by differences between TE1 and TE2 were measured in phantom experiments. We then evaluated the validity of this method by examination of a volunteer. The phantom study showed a large error when the TE interval was a multiple of the in-phase time for fat and water, and the error increased according to the prolongation of the TE. In the human study, phase wrapping readily occurred in the phase-change image. However, the region of fat was easily extracted with high-pass filtering. The fat signal can also be extracted by use of scanners that cannot be set simultaneously to in-phase and out-of-phase TE.
- Open Access
- 1 January 2007
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 6 (2) , 67-73
Correction of inhomogeneous RF field using multiple SPGR signals for high-field spin-echo MRI.
Purpose: To propose a simple and useful method for correcting nonuniformity of high-field (3 Tesla) T1-weighted spin-echo (SE) images based on a B1 field map estimated from gradient recalled echo (GRE) signals. Methods: To estimate B1 inhomogeneity, spoiled gradient recalled echo (SPGR) images were collected using a fixed repetition time of 70 ms, flip angles of 45 and 90 degrees, and echo times of 4.8 and 10.4 ms. Selection of flip angles was based on the observation that the relative intensity changes in SPGR signals were very similar among different tissues at larger flip angles than the Ernst angle. Accordingly, spatial irregularity that was observed on a signal ratio map of the SPGR images acquired with these 2 flip angles was ascribed to inhomogeneity of the B1 field. Dual echo time was used to eliminate T2* effects. The ratio map that was acquired was scaled to provide an intensity correction map for SE images. Both phantom and volunteer studies were performed using a 3T magnetic resonance scanner to validate the method. Results: In the phantom study, the uniformity of the T1-weighted SE image improved by 23%. Images of human heads also showed practically sufficient improvement in the image uniformity. Conclusion: The present method improves the image uniformity of high-field T1-weighted SE images.
- 1 January 2007
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 6 (2) , 67-73
Open AccessCorrection of inhomogeneous RF field using multiple SPGR signals for high-field spin-echo MRI.
Purpose: To propose a simple and useful method for correcting nonuniformity of high-field (3 Tesla) T1-weighted spin-echo (SE) images based on a B1 field map estimated from gradient recalled echo (GRE) signals. Methods: To estimate B1 inhomogeneity, spoiled gradient recalled echo (SPGR) images were collected using a fixed repetition time of 70 ms, flip angles of 45 and 90 degrees, and echo times of 4.8 and 10.4 ms. Selection of flip angles was based on the observation that the relative intensity changes in SPGR signals were very similar among different tissues at larger flip angles than the Ernst angle. Accordingly, spatial irregularity that was observed on a signal ratio map of the SPGR images acquired with these 2 flip angles was ascribed to inhomogeneity of the B1 field. Dual echo time was used to eliminate T2* effects. The ratio map that was acquired was scaled to provide an intensity correction map for SE images. Both phantom and volunteer studies were performed using a 3T magnetic resonance scanner to validate the method. Results: In the phantom study, the uniformity of the T1-weighted SE image improved by 23%. Images of human heads also showed practically sufficient improvement in the image uniformity. Conclusion: The present method improves the image uniformity of high-field T1-weighted SE images.
- 1 May 2003
- Vol. 63, 13-7
[Perfusion imaging: with special reference to continuous arterial spin labeling].
- 1 May 2003
- Vol. 63, 13-7
[Perfusion imaging: with special reference to continuous arterial spin labeling].