Hobey Garrone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hobey Garrone has a total of 168 co-authors. Here are the top co-authors by number of shared publications:
- Federico Malnati
Politecnico di Torino, Corso Duca degli Abruzzi 24
3 shared publications - Mauro Rajteri
Istituto Nazionale di Ricerca Metrologica (INRiM)
3 shared publications - Alessandro Ruocco
Università degli Studi di Roma Tre
2 shared publications - Alice Apponi
INFN Sezione di Roma Tre
2 shared publications C. Pérez de Los Heros
Uppsala University
2 shared publications- Carlo Mariani
INFN Sezione di Roma
2 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Toward high-resolution low-energy electron spectroscopy with transition-edge sensors
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Open AccessToward high-resolution low-energy electron spectroscopy with transition-edge sensors
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.
- Open Access
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Phenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Open AccessPhenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-4
Development of Ti/Au Transition-Edge Sensors for Single-Photon Detection
Transition-edge sensors (TESs) have shown remarkable energy resolution and photon-number resolving ability. In this paper, we report the fabrication and characterization of Ti/Au optical TESs for the detection of single photon at the telecommunication wavelength 1550 nm. A SiO 2 /SiN x antireflection coating is deposited on top of TESs by an inductively coupled plasma-assisted plasma-enhanced chemical vapor deposition (ICP-PECVD) process to improve the detection efficiency. Ti/Au (50/60 nm) TES with a small sensitive area 10 µm× 10 µm shows an energy resolution of 0.12 eV. The TES with a large sensitive area 20 µm× 20 µm can discriminate up to 55 incident photons and the detection efficiency is 46%.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-4
Development of Ti/Au Transition-Edge Sensors for Single-Photon Detection
Transition-edge sensors (TESs) have shown remarkable energy resolution and photon-number resolving ability. In this paper, we report the fabrication and characterization of Ti/Au optical TESs for the detection of single photon at the telecommunication wavelength 1550 nm. A SiO 2 /SiN x antireflection coating is deposited on top of TESs by an inductively coupled plasma-assisted plasma-enhanced chemical vapor deposition (ICP-PECVD) process to improve the detection efficiency. Ti/Au (50/60 nm) TES with a small sensitive area 10 µm× 10 µm shows an energy resolution of 0.12 eV. The TES with a large sensitive area 20 µm× 20 µm can discriminate up to 55 incident photons and the detection efficiency is 46%.