Ali Dahaghin
Research Subjects
Ali Dahaghin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Agnieszka Boszczyk
Affiliation Department of Optics and Photonics, Wroclaw University of Science and Technology, Wrocław, Poland
2 shared publicationsAgnieszka Jóźwik
Department of Optics and Photonics, , Wrocław, Poland
1 shared publicationDamian Siedlecki
Department of Optics and Photonics, , Wrocław, Poland
1 shared publication- Damian Siedlecki
Institute of Physics, Wroclaw University of Technology, Wroclaw, Poland
1 shared publication - Dariusz P. Danel
Department of Anthropology, Ludwik Hirszfeld Institute of Immunology and Experimental Therapy, Polish Academy of Sciences, Wroclaw, Poland
1 shared publication Fatemeh Mousavi
1 shared publication
Latest Publications
- Open Access
- 6 November 2026
- Published by Elsevier in Experimental Eye Research
- Vol. 274
A biomechanical framework for crystalline lens oscillations: Coupled effects of stiffness and damping
- 6 November 2026
- Published by Elsevier in Experimental Eye Research
- Vol. 274
Open AccessA biomechanical framework for crystalline lens oscillations: Coupled effects of stiffness and damping
- Open Access
- 25 March 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (3) , e0320205
Effect of intraocular pressure on crystalline lens oscillations: a computational study using porcine eye model
This study addresses a crucial knowledge gap by investigating the impact of intraocular pressure (IOP) on the wobbling characteristics of the crystalline lens in an ex vivo setting. It utilizes previous validated computational porcine eye models, which offer anatomical and physiological similarities to the human eye. These models incorporate fluid-structure interaction (FSI) to simulate the mechanical interaction between the fluids of the eye and the solid structures. Simulations were conducted under constant mechanical properties and boundary conditions, allowing for precise quantification of lens wobbling behavior with varying IOP levels. Various trends in lens displacement were observed at various IOP levels, revealing significant variations in both magnitude and duration. The results demonstrate the central role of intraocular pressure in influencing lens overshooting during rotational motion, with potential clinical implications. The observed lens displacement patterns, particularly in conditions like glaucoma, underscore the importance of considering IOP as a critical factor in understanding ocular biomechanics. Beyond immediate biomechanical relevance, the study’s findings suggest the potential use of the Purkinje imaging system as a non-invasive method for IOP estimation based on lens overshoot as an “inverse solution” strategy. This non-invasive imaging technique offers a promising alternative to traditional methods, minimizing patient discomfort and potentially enhancing measurement precision.
- 25 March 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (3) , e0320205
Open AccessEffect of intraocular pressure on crystalline lens oscillations: a computational study using porcine eye model
This study addresses a crucial knowledge gap by investigating the impact of intraocular pressure (IOP) on the wobbling characteristics of the crystalline lens in an ex vivo setting. It utilizes previous validated computational porcine eye models, which offer anatomical and physiological similarities to the human eye. These models incorporate fluid-structure interaction (FSI) to simulate the mechanical interaction between the fluids of the eye and the solid structures. Simulations were conducted under constant mechanical properties and boundary conditions, allowing for precise quantification of lens wobbling behavior with varying IOP levels. Various trends in lens displacement were observed at various IOP levels, revealing significant variations in both magnitude and duration. The results demonstrate the central role of intraocular pressure in influencing lens overshooting during rotational motion, with potential clinical implications. The observed lens displacement patterns, particularly in conditions like glaucoma, underscore the importance of considering IOP as a critical factor in understanding ocular biomechanics. Beyond immediate biomechanical relevance, the study’s findings suggest the potential use of the Purkinje imaging system as a non-invasive method for IOP estimation based on lens overshoot as an “inverse solution” strategy. This non-invasive imaging technique offers a promising alternative to traditional methods, minimizing patient discomfort and potentially enhancing measurement precision.
- Open Access
- 9 April 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1348774
Investigation of crystalline lens overshooting: ex vivo experiment and optomechanical simulation results
Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging.Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid–structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes.Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor.Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.
- 9 April 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1348774
Open AccessInvestigation of crystalline lens overshooting: ex vivo experiment and optomechanical simulation results
Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging.Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid–structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes.Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor.Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.