D. A. Polkoshnikov
D. A. Polkoshnikov has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Skorobogatov
Ivanovo State Power Engineering University, 153003, Ivanovo, Russia
2 shared publications - A. S. Strakhov
V. I. Lenin Ivanovo State Power Engineering University, Ivanovo, Russia
2 shared publications - Alexander Nazarychev
Department of Electric Power Engineering and Electromechanics, Saint Petersburg Mining University, 199106 St. Petersburg, Russia
2 shared publications - E. M. Novoselov
Ivanovo State Power Engineering University, 153003, Ivanovo, Russia
2 shared publications A. A. Skorobogatov
V. I. Lenin Ivanovo State Power Engineering University, Ivanovo, Russia
1 shared publicationA. S. Strakhov
V. I. Lenin Ivanovo State Power Engineering University, Ivanovo, Russia
1 shared publication
Latest Publications
- 1 September 2025
- Published by Springer Nature in Power Technology and Engineering
- Vol. 59 (3) , 461-467
Method for Determining the Dynamic Eccentricity of Induction Motors During Run-Down
- 1 September 2025
- Published by Springer Nature in Power Technology and Engineering
- Vol. 59 (3) , 461-467
Method for Determining the Dynamic Eccentricity of Induction Motors During Run-Down
- 1 August 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 56 (8) , 661-667
A Method for Monitoring the Condition of Rotor Windings in Induction Motors during Startup Based on Stator Current
—At present, one of the most effective methods for detecting dangling bars in squirrel-cage rotor windings of induction motors operating under severe starting conditions is the spectral analysis of stator current in a steady-state operation mode. The existing methods of testing in starting modes are not sensitive enough or their study has not been completed, although it is precisely such methods that allow diagnostics of machines that cannot be inspected in the steady-state operation mode. The purpose of this article is to develop a method for monitoring the state of rotor windings in induction motors operating under severe starting conditions based on the stator current in the starting mode, which is an urgent task. The studies were carried out both on digital models of an induction motor, developed in the Ansys software package, and on an experimental stand with a low voltage supplied to a low-voltage motor to increase the duration of its start. Signal processing is performed in the Matlab software package using the short-time Fourier transform. It is shown that only in the presence of a broken rotor bar, the amplitude of the harmonic component of the order coinciding with the number of motor pole pairs sharply increases at the lower side frequency; this indicates the presence of damage. It is shown that the developed technique for monitoring the condition of rotor windings in induction motors operating under severe starting conditions is more sensitive to broken rotor bars than the existing methods; this makes it possible to timely detect damage to rotor windings and prevent sudden failures of induction motors.
- 1 August 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 56 (8) , 661-667
A Method for Monitoring the Condition of Rotor Windings in Induction Motors during Startup Based on Stator Current
—At present, one of the most effective methods for detecting dangling bars in squirrel-cage rotor windings of induction motors operating under severe starting conditions is the spectral analysis of stator current in a steady-state operation mode. The existing methods of testing in starting modes are not sensitive enough or their study has not been completed, although it is precisely such methods that allow diagnostics of machines that cannot be inspected in the steady-state operation mode. The purpose of this article is to develop a method for monitoring the state of rotor windings in induction motors operating under severe starting conditions based on the stator current in the starting mode, which is an urgent task. The studies were carried out both on digital models of an induction motor, developed in the Ansys software package, and on an experimental stand with a low voltage supplied to a low-voltage motor to increase the duration of its start. Signal processing is performed in the Matlab software package using the short-time Fourier transform. It is shown that only in the presence of a broken rotor bar, the amplitude of the harmonic component of the order coinciding with the number of motor pole pairs sharply increases at the lower side frequency; this indicates the presence of damage. It is shown that the developed technique for monitoring the condition of rotor windings in induction motors operating under severe starting conditions is more sensitive to broken rotor bars than the existing methods; this makes it possible to timely detect damage to rotor windings and prevent sudden failures of induction motors.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 56 (5) , 408-416
Experimental Determination of Diagnostic Signs of Damage to the Rotor Windings of High-Voltage Power Plant Motors in Startup Mode
Induction electric motors are widely used as drives of various mechanisms in power engineering and industry. Their failure can lead to costly repairs, to a reduction in power, or, for example, to a complete shutdown of a power plant unit. One of the reasons for the failure of high-voltage induction motors operating under severe starting conditions is damage to the squirrel-cage rotor winding. Existing methods for monitoring the breakage of the winding bars of such electric motors are ineffective due to the peculiarities of their operating modes. Therefore, monitoring the condition of the bars of high-voltage motors at startup and searching for diagnostic signs is an urgent task. Initially, the studies were carried out with a model of a high-voltage induction motor, developed in the ANSYS software package. To confirm the results obtained for a real motor, research has also been conducted on the developed experimental bench. The recorded signals were processed based on the method of short-time Fourier transform in the MatLab environment. In the course of the study, it was shown that, in the presence of bar breaks, the spectrum of an induction motor exhibits sharply increased amplitudes of harmonic components of the dummy rotor winding at the lower side frequencies of the first orders; this confirms the possibility of using external magnetic field signal at startup to detect the presence of bar breaks in the squirrel-cage rotor winding of high-voltage induction motors with heavy prolonged starts.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 56 (5) , 408-416
Experimental Determination of Diagnostic Signs of Damage to the Rotor Windings of High-Voltage Power Plant Motors in Startup Mode
Induction electric motors are widely used as drives of various mechanisms in power engineering and industry. Their failure can lead to costly repairs, to a reduction in power, or, for example, to a complete shutdown of a power plant unit. One of the reasons for the failure of high-voltage induction motors operating under severe starting conditions is damage to the squirrel-cage rotor winding. Existing methods for monitoring the breakage of the winding bars of such electric motors are ineffective due to the peculiarities of their operating modes. Therefore, monitoring the condition of the bars of high-voltage motors at startup and searching for diagnostic signs is an urgent task. Initially, the studies were carried out with a model of a high-voltage induction motor, developed in the ANSYS software package. To confirm the results obtained for a real motor, research has also been conducted on the developed experimental bench. The recorded signals were processed based on the method of short-time Fourier transform in the MatLab environment. In the course of the study, it was shown that, in the presence of bar breaks, the spectrum of an induction motor exhibits sharply increased amplitudes of harmonic components of the dummy rotor winding at the lower side frequencies of the first orders; this confirms the possibility of using external magnetic field signal at startup to detect the presence of bar breaks in the squirrel-cage rotor winding of high-voltage induction motors with heavy prolonged starts.