Cevdet Akyel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cevdet Akyel has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A. Sklyuyev
École Polytechnique Montréal Département de Génie Physique C.P. 6079, Succ. Centre-ville, Montréal, Québec H3C 3A7, Canada
2 shared publications- Arthur Yelon
École Polytechnique Montréal
2 shared publications M. Ciureanu
École Polytechnique Montréal Département de Génie Physique C.P. 6079, Succ. Centre-ville, Montréal, Québec H3C 3A7, Canada
2 shared publicationsP. Ciureanu
École Polytechnique Montréal Département de Génie Physique C.P. 6079, Succ. Centre-ville, Montréal, Québec H3C 3A7, Canada
2 shared publications- Slobodan Babic
Independent Researcher, 53 Berlioz 101, Montréal, QC H3E 1N2, Canada
2 shared publications - David Menard
Polytechnique Montreal
1 shared publication
Latest Publications
- Open Access
- 10 June 2024
- Published by Wiley
Transmission des Ondes Électromagnétiques
A document by Cevdet Akyel . Click on the document to view its contents.
- 10 June 2024
- Published by Wiley
Open AccessTransmission des Ondes Électromagnétiques
A document by Cevdet Akyel . Click on the document to view its contents.
- Open Access
- 30 April 2021
- Published by GSC Online Press in World Journal of Advanced Engineering Technology and Sciences
- Vol. 2 (1) , 110-121
Calculating propulsive and restoring electromagnetic forces between massive circular coils of rectangular cross section with inclined axes in air
In this paper we give the new formulas for calculating the propulsive and the restoring electromagnetic forces between the loops in air whose centers are in the different axes. These new formulas are used to calculate the propulsive and the restoring forces between two inclined massive coils of rectangular cross section whose centers are in the different axes. The filament method is used. Results obtained by the presented approach are in remarkably good agreement with already published data. Electromagnetic forces can be used for various applications, it is very versatile; there are a plethora of ways to utilize electromagnetic forces and energy, from small scale uses e.g., microchips to larger scale and lifesaving uses e.g., radiotherapy.
- 30 April 2021
- Published by GSC Online Press in World Journal of Advanced Engineering Technology and Sciences
- Vol. 2 (1) , 110-121
Open AccessCalculating propulsive and restoring electromagnetic forces between massive circular coils of rectangular cross section with inclined axes in air
In this paper we give the new formulas for calculating the propulsive and the restoring electromagnetic forces between the loops in air whose centers are in the different axes. These new formulas are used to calculate the propulsive and the restoring forces between two inclined massive coils of rectangular cross section whose centers are in the different axes. The filament method is used. Results obtained by the presented approach are in remarkably good agreement with already published data. Electromagnetic forces can be used for various applications, it is very versatile; there are a plethora of ways to utilize electromagnetic forces and energy, from small scale uses e.g., microchips to larger scale and lifesaving uses e.g., radiotherapy.
- 20 April 2011
- Published by Wiley in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
- Vol. 24 (3) , 230-243
Torque calculation between circular coils with inclined axes in air
- 20 April 2011
- Published by Wiley in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
- Vol. 24 (3) , 230-243
Torque calculation between circular coils with inclined axes in air
- 15 January 2009
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 105 (2) , 023914
Microwave studies of magnetic anisotropy of Co nanowire arrays
The effect of magnetocrystalline anisotropy and dipolar interactions in Co nanowire arrays is studied by ferromagnetic resonance (FMR). Microwave measurements performed by the microstripline method are reported for two series of crystalline hcp Co (with the axis nominally perpendicular and parallel to the wires ) and an amorphous alloy with Co as the main component— . Extrapolation of the high field linear part of the resonance curve (frequency versus dc field) permitted an evaluation of the effective anisotropy fields for saturated samples, as well as of the intrinsic fields , showing that the great differences between the three series are due to the magnetocrystalline anisotropy. The values for the two series of Co are discussed in terms of a model which accounts for the effect of the distributions of the axis orientation in systems of uniaxial ferromagnets. The observed dependence of the effective anisotropy fields on the array geometry (wire length and diameter) is interpreted in terms of the interwire dipolar interactions and found to be in agreement with theoretical predictions based on a micromagnetic model. The fact that the resonance frequencies at are geometry dependent shows that magnetostatic interactions are still significant at remanence. A second series of FMR experiments was performed at constant frequency (38 GHz), with the purpose of obtaining the angle dependence of the resonance field. These experiments provided an alternative method for the evaluation of the effective anisotropy field. The angle dependence of the resonance field for fitted the simplest equation for magnets with uniaxial anisotropy, obtained considering only the first order term in the expression of the magnetocrystalline energy as a function of the magnetization orientation. The same is not true for , which required inclusion of a second order term.- 15 January 2009
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 105 (2) , 023914
Microwave studies of magnetic anisotropy of Co nanowire arrays
The effect of magnetocrystalline anisotropy and dipolar interactions in Co nanowire arrays is studied by ferromagnetic resonance (FMR). Microwave measurements performed by the microstripline method are reported for two series of crystalline hcp Co (with the axis nominally perpendicular and parallel to the wires ) and an amorphous alloy with Co as the main component— . Extrapolation of the high field linear part of the resonance curve (frequency versus dc field) permitted an evaluation of the effective anisotropy fields for saturated samples, as well as of the intrinsic fields , showing that the great differences between the three series are due to the magnetocrystalline anisotropy. The values for the two series of Co are discussed in terms of a model which accounts for the effect of the distributions of the axis orientation in systems of uniaxial ferromagnets. The observed dependence of the effective anisotropy fields on the array geometry (wire length and diameter) is interpreted in terms of the interwire dipolar interactions and found to be in agreement with theoretical predictions based on a micromagnetic model. The fact that the resonance frequencies at are geometry dependent shows that magnetostatic interactions are still significant at remanence. A second series of FMR experiments was performed at constant frequency (38 GHz), with the purpose of obtaining the angle dependence of the resonance field. These experiments provided an alternative method for the evaluation of the effective anisotropy field. The angle dependence of the resonance field for fitted the simplest equation for magnets with uniaxial anisotropy, obtained considering only the first order term in the expression of the magnetocrystalline energy as a function of the magnetization orientation. The same is not true for , which required inclusion of a second order term.- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08407789,p. 1486-1489
Measurement of Complex Permeability of Ferromagnetic Nanowires using Cavity Perturbation Techniques
The complex permeability of nanowire arrays of different materials was measured at X-band using a cavity perturbation technique. Compared with ferromagnetic films of the same materials, a relatively high permeability with a low loss is obtained. Our results indicate that ferromagnetic nanowire arrays have important potential technological applications as magnetodielectrics for microwave devices such as variable attenuators, phase shifters, modulators, stop-band filters and power absorbing terminals
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08407789,p. 1486-1489
Measurement of Complex Permeability of Ferromagnetic Nanowires using Cavity Perturbation Techniques
The complex permeability of nanowire arrays of different materials was measured at X-band using a cavity perturbation technique. Compared with ferromagnetic films of the same materials, a relatively high permeability with a low loss is obtained. Our results indicate that ferromagnetic nanowire arrays have important potential technological applications as magnetodielectrics for microwave devices such as variable attenuators, phase shifters, modulators, stop-band filters and power absorbing terminals
- Open Access
- 1 May 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 44 (5) , 770-777
Characterization of highly dispersive materials using composite coaxial cells: electromagnetic analysis and wideband measurement
- 1 May 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 44 (5) , 770-777
Open AccessCharacterization of highly dispersive materials using composite coaxial cells: electromagnetic analysis and wideband measurement