Evan Walser-Kuntz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Evan Walser-Kuntz has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Okada
Department of Heart Failure and Transplantation, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
2 shared publications John R. Lesser
Valve Science Center (A.P., P.S., M.E.-S., A.O., M.A., E.W.-K., J.R.L., V.N.B., N.H.), Minneapolis Heart Institute Foundation, MN
2 shared publications- Miho Fukui
Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA
2 shared publications - Paul Sorajja
Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, MN (P. Sorajja)
2 shared publications - Vinayak N. Bapat
Valve Science Center, Minneapolis Heart Institute Foundation, MN (V.N.B.).
2 shared publications - Aldo Salgado
Center for Cardiovas- cular Disease University of Minnesota Minneapolis United States
1 shared publication
Latest Publications
- Open Access
- 7 December 2025
- Published by Sapientia Publishing Group in Exercise Medicine
- Vol. 9, 3
Cardiorespiratory Fitness Changes Following an Unsupervised Exercise Prescription in an Executive Health Program
Objectives: Office workers in the U.S. have the lowest cardiorespiratory fitness (CRF) among all occupations, a concern given the association between low CRF and increased risk of cardiovascular disease and all-cause mortality. The prevalence of low CRF and the impact of an unsupervised exercise prescription on CRF among business professionals were determined.Methods: This retrospective analysis utilized data from 65 of 397 self-selected business professionals enrolled in the University of Minnesota’s M-Health Fairview Executive Wellness program. CRF, using VO₂max, was determined in mL/kg/min using the Bruce protocol. Participants were reassessed approximately two years later, but adherence to the exercise program was not. CRF was categorized by age- and sex-adjusted VO₂max percentiles: low (<25th), fair to good (25th–74th), and superior to excellent (≥75th). VO₂max changes were classified as no change (10%).Results: The participants' mean (SD) age was 50.7 (9.7) years, primarily comprising white males, and most (78%) were never smokers. Nearly two-thirds were overweight and had dyslipidemia; 15% had hypertension, and 27% had prediabetes. Over a mean (SD) 2.13 (1.01) years of follow-up, 69.2% had no change to their CRF, 12.3% decreased, and 18.5% increased compared to the first clinic visit. Among those with a low baseline CRF (n=27), 55.6% remained unchanged, 3.7% declined, and in 40.7% of cases, their CRF improved. In the fair to good CRF group (n = 48), 15% declined, 80% remained the same, and 5% improved. Of those with superior CRF, 22.2% experienced a decline in their CRF level, while 77.8% maintained their level. There were no correlations between the change in VO₂max and the change in anthropometric or metabolic variables.Conclusions: Unsupervised exercise prescriptions did not significantly improve CRF for most participants. However, baseline fitness level influenced outcomes, with those starting at lower CRF levels more likely to improve.
- 7 December 2025
- Published by Sapientia Publishing Group in Exercise Medicine
- Vol. 9, 3
Open AccessCardiorespiratory Fitness Changes Following an Unsupervised Exercise Prescription in an Executive Health Program
Objectives: Office workers in the U.S. have the lowest cardiorespiratory fitness (CRF) among all occupations, a concern given the association between low CRF and increased risk of cardiovascular disease and all-cause mortality. The prevalence of low CRF and the impact of an unsupervised exercise prescription on CRF among business professionals were determined.Methods: This retrospective analysis utilized data from 65 of 397 self-selected business professionals enrolled in the University of Minnesota’s M-Health Fairview Executive Wellness program. CRF, using VO₂max, was determined in mL/kg/min using the Bruce protocol. Participants were reassessed approximately two years later, but adherence to the exercise program was not. CRF was categorized by age- and sex-adjusted VO₂max percentiles: low (<25th), fair to good (25th–74th), and superior to excellent (≥75th). VO₂max changes were classified as no change (10%).Results: The participants' mean (SD) age was 50.7 (9.7) years, primarily comprising white males, and most (78%) were never smokers. Nearly two-thirds were overweight and had dyslipidemia; 15% had hypertension, and 27% had prediabetes. Over a mean (SD) 2.13 (1.01) years of follow-up, 69.2% had no change to their CRF, 12.3% decreased, and 18.5% increased compared to the first clinic visit. Among those with a low baseline CRF (n=27), 55.6% remained unchanged, 3.7% declined, and in 40.7% of cases, their CRF improved. In the fair to good CRF group (n = 48), 15% declined, 80% remained the same, and 5% improved. Of those with superior CRF, 22.2% experienced a decline in their CRF level, while 77.8% maintained their level. There were no correlations between the change in VO₂max and the change in anthropometric or metabolic variables.Conclusions: Unsupervised exercise prescriptions did not significantly improve CRF for most participants. However, baseline fitness level influenced outcomes, with those starting at lower CRF levels more likely to improve.
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (8) , e015181
Feasibility of Computed Tomography as a Gatekeeper for Invasive Angiography Before TAVR: A Pragmatic Real-World Experience
BACKGROUND: Although pretranscatheter aortic valve replacement-computed tomography angiography (TAVR-CTA) has shown a good correlation with invasive coronary angiography (ICA) for ruling out obstructive coronary artery disease (CAD), its clinical effectiveness and safety as a gatekeeper for ICA pre-transcatheter aortic valve replacement (pre-TAVR) remain unclear. This study aims to determine whether routine TAVR-CTA, without premedication, could safely defer and guide the need for ICA pre-TAVR. METHODS: Patients who underwent TAVR evaluation with either TAVR-CTA or ICA to determine CAD between 2017 and 2022 were included. Patients with prior coronary artery bypass grafts were excluded, and the remaining patients were divided into CAD screening with TAVR-CTA or ICA groups. The primary outcome was symptom-driven revascularization at 1 year post-TAVR. RESULTS: Among 1165 patients (median age, 81 years; 46% women), 464 were in TAVR-CTA group and 701 were in the ICA group. Prevalence of CAD was similar (37% versus 41%; P =0.2). A total of 53% of patients were exempted from ICA after TAVR-CTA, given the absence of proximal obstructive CAD, whereas 17% had inconclusive TAVR-CTA interpretation, 15% desired for ICA despite CAD exclusion by TAVR-CTA, and 14% had obstructive CAD requiring further ICA. Elevated coronary artery calcium score and the presence of stents were associated with need for ICA after TAVR-CTA. TAVR-CTA revealed a per-patient sensitivity of 89%, specificity of 75%, positive predictive value of 69%, and negative predictive value of 91% for identifying obstructive CAD. Importantly, symptom-driven revascularization, acute coronary syndrome, and unplanned ICA at 1 year after TAVR were all low and not different between TAVR-CTA versus ICA (0.8% versus 1.8%, P =0.158; 1.6% versus 1.7%, P =0.846; 2.7% versus 2.8%, P =0.767; respectively). CONCLUSIONS: In comparison with routine ICA pre-TAVR, integration of TAVR-CTA in our program resulted in up to 53% of patients exempted from ICA, while maintaining patient safety. This approach could have important clinical implications to improve patient access, experience, value, and throughput.
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (8) , e015181
Feasibility of Computed Tomography as a Gatekeeper for Invasive Angiography Before TAVR: A Pragmatic Real-World Experience
BACKGROUND: Although pretranscatheter aortic valve replacement-computed tomography angiography (TAVR-CTA) has shown a good correlation with invasive coronary angiography (ICA) for ruling out obstructive coronary artery disease (CAD), its clinical effectiveness and safety as a gatekeeper for ICA pre-transcatheter aortic valve replacement (pre-TAVR) remain unclear. This study aims to determine whether routine TAVR-CTA, without premedication, could safely defer and guide the need for ICA pre-TAVR. METHODS: Patients who underwent TAVR evaluation with either TAVR-CTA or ICA to determine CAD between 2017 and 2022 were included. Patients with prior coronary artery bypass grafts were excluded, and the remaining patients were divided into CAD screening with TAVR-CTA or ICA groups. The primary outcome was symptom-driven revascularization at 1 year post-TAVR. RESULTS: Among 1165 patients (median age, 81 years; 46% women), 464 were in TAVR-CTA group and 701 were in the ICA group. Prevalence of CAD was similar (37% versus 41%; P =0.2). A total of 53% of patients were exempted from ICA after TAVR-CTA, given the absence of proximal obstructive CAD, whereas 17% had inconclusive TAVR-CTA interpretation, 15% desired for ICA despite CAD exclusion by TAVR-CTA, and 14% had obstructive CAD requiring further ICA. Elevated coronary artery calcium score and the presence of stents were associated with need for ICA after TAVR-CTA. TAVR-CTA revealed a per-patient sensitivity of 89%, specificity of 75%, positive predictive value of 69%, and negative predictive value of 91% for identifying obstructive CAD. Importantly, symptom-driven revascularization, acute coronary syndrome, and unplanned ICA at 1 year after TAVR were all low and not different between TAVR-CTA versus ICA (0.8% versus 1.8%, P =0.158; 1.6% versus 1.7%, P =0.846; 2.7% versus 2.8%, P =0.767; respectively). CONCLUSIONS: In comparison with routine ICA pre-TAVR, integration of TAVR-CTA in our program resulted in up to 53% of patients exempted from ICA, while maintaining patient safety. This approach could have important clinical implications to improve patient access, experience, value, and throughput.
- 1 August 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (8) , e013903
In Vivo Computed Tomography Sizing for Redo–Transcatheter Aortic Valve Replacement in Evolut Valves: Impact on Sizing, Feasibility, and Prosthesis-Patient Mismatch
BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo–transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P P <0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.
- 1 August 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (8) , e013903
In Vivo Computed Tomography Sizing for Redo–Transcatheter Aortic Valve Replacement in Evolut Valves: Impact on Sizing, Feasibility, and Prosthesis-Patient Mismatch
BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo–transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P P <0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.