Fanjip René Constant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fanjip René Constant has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Nanfak
Laboratory of Electronic, Electrical Engineering, Automation and Telecommunication, National Higher Polytechnic School of Douala, University of Douala, Douala, Cameroon
1 shared publication Charles Hubert Kom
Laboratory of Electronic, Electrical Engineering, Automation and Telecommunication, National Higher Polytechnic School of Douala University of Douala Douala Cameroon
1 shared publication- Charles Hubert Kom
Laboratory of Electronic, Electrical Engineering, Automation and Telecommunication, National Higher Polytechnic School of Douala, University of Douala, Douala, Cameroon
1 shared publication - Gildas Martial Ngaleu
Laboratory of Energy, Materials, Modelling and Methods National Higher Polytechnic School of Douala University of Douala Douala Cameroon
1 shared publication - Luc Vivien Assiene Mouodo
Department of Electrical Engineering, Higher Normal School of Technical Education (ENSET), University of Douala, Douala P.O. Box 1872, Cameroon
1 shared publication - Serge Raoul Dzonde Naoussi
Technology and Applied Sciences Laboratory University Institute of Technology of Douala, University of Douala Douala Cameroon
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Control of Photovoltaic‐Based Shunt Active Power Filter System Based on Optimal Operating Point Tracking of PV System for Harmonic Mitigation, Load Supply and Grid Current Injection
This paper explores an innovative control strategy for photovoltaic‐based shunt active power filters (PV‐SAPF), aiming to enhance power quality, support load supply, and inject low‐harmonic current into the grid. Unlike existing approaches that rely solely on MPPT‐controlled inverters for optimal PV performance, this method integrates an optimal operating point tracking (OOPT) algorithm with a harmonic identification method (HIM), enabling comprehensive system functionality. The control scheme employs a HIM modules to generate reference currents, facilitating harmonic mitigation, reactive power compensation, and load support under varying energy production conditions. MATLAB/Simulink simulations demonstrate the effectiveness of this approach in maintaining grid stability during both energy surplus and deficit scenarios. When energy exceeds load demand, the PV‐SAPF supplies the load and injects less than 1% THD into the grid; during underproduction, it partially supplies the load and mitigates harmonics. The results adhere to IEEE Std 519‐2022 standards, showcasing the system's ability to improve power quality and grid harmony. Notably, this strategy differs from previous methods by removing the need for MPPT‐controlled converters and allowing compatibility with any harmonic identification technique, thus offering a versatile and efficient solution for integrating PV systems into the power grid.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessControl of Photovoltaic‐Based Shunt Active Power Filter System Based on Optimal Operating Point Tracking of PV System for Harmonic Mitigation, Load Supply and Grid Current Injection
This paper explores an innovative control strategy for photovoltaic‐based shunt active power filters (PV‐SAPF), aiming to enhance power quality, support load supply, and inject low‐harmonic current into the grid. Unlike existing approaches that rely solely on MPPT‐controlled inverters for optimal PV performance, this method integrates an optimal operating point tracking (OOPT) algorithm with a harmonic identification method (HIM), enabling comprehensive system functionality. The control scheme employs a HIM modules to generate reference currents, facilitating harmonic mitigation, reactive power compensation, and load support under varying energy production conditions. MATLAB/Simulink simulations demonstrate the effectiveness of this approach in maintaining grid stability during both energy surplus and deficit scenarios. When energy exceeds load demand, the PV‐SAPF supplies the load and injects less than 1% THD into the grid; during underproduction, it partially supplies the load and mitigates harmonics. The results adhere to IEEE Std 519‐2022 standards, showcasing the system's ability to improve power quality and grid harmony. Notably, this strategy differs from previous methods by removing the need for MPPT‐controlled converters and allowing compatibility with any harmonic identification technique, thus offering a versatile and efficient solution for integrating PV systems into the power grid.
- Open Access
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 1712-1726
Sliding Mode Control of a Photovoltaic Based Shunt Active Power Filter in Islanding Operation
Abstract- Renewable energy sources (RES) are constantly evolving nowadays due to the ever-increasing energy needs and the depletion of fossil fuel reserves. This, together with power quality problems, has led to the development of photovoltaic-based shunt active power filter (PV-SAPF) systems. However, the performance of these systems is linked to the control strategy used. Hence, to enable the PV system to perform the functions of power quality improvement, load supply, low THD current injection into the grid, and to avoid damage to connected loads during islanding operation, this paper presents a new control strategy for PV-SAPF in islanding operation. This control strategy is based on the optimal operating point tracking of the PV system. Multi-variable filter harmonic identification method is used for the determination of the harmonic and fundamental components of the reference currents of the grid-connected inverter. The islanding algorithm is used to detect a voluntary or involuntary disconnection from the grid. The performances of the proposed control strategy are evaluated for different operating scenarios by numerical simulations performed in MATLAB/Simulink software. The simulation results obtained show the good adaptation of the system in the different operating scenarios with harmonic distortion rates lower than the 5% recommended by the IEEE Std. 519-2014 standard, even during islanding. The responsiveness of the proposed control strategy is observed with the adaptation of the modulation coefficients of the fundamental components of the reference currents in the different operating modes.
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 1712-1726
Open AccessSliding Mode Control of a Photovoltaic Based Shunt Active Power Filter in Islanding Operation
Abstract- Renewable energy sources (RES) are constantly evolving nowadays due to the ever-increasing energy needs and the depletion of fossil fuel reserves. This, together with power quality problems, has led to the development of photovoltaic-based shunt active power filter (PV-SAPF) systems. However, the performance of these systems is linked to the control strategy used. Hence, to enable the PV system to perform the functions of power quality improvement, load supply, low THD current injection into the grid, and to avoid damage to connected loads during islanding operation, this paper presents a new control strategy for PV-SAPF in islanding operation. This control strategy is based on the optimal operating point tracking of the PV system. Multi-variable filter harmonic identification method is used for the determination of the harmonic and fundamental components of the reference currents of the grid-connected inverter. The islanding algorithm is used to detect a voluntary or involuntary disconnection from the grid. The performances of the proposed control strategy are evaluated for different operating scenarios by numerical simulations performed in MATLAB/Simulink software. The simulation results obtained show the good adaptation of the system in the different operating scenarios with harmonic distortion rates lower than the 5% recommended by the IEEE Std. 519-2014 standard, even during islanding. The responsiveness of the proposed control strategy is observed with the adaptation of the modulation coefficients of the fundamental components of the reference currents in the different operating modes.