Feng Chi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Feng Chi has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Rui Guo
Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou, Guangdong 510060, P.R. China
3 shared publications Tong Wang
3 shared publicationsXiuying Mai
National Key Laboratory of South China Oncology Prevention and Treatment, Guangzhou, China; Guangdong Provincial Clinical Research Center for Cancer, Guangzhou, China; Sun Yat-sen University Cancer Center, Guangzhou, China
3 shared publicationsYu Luo
3 shared publicationsChulong Zhang
Shenzhen Institute of Advanced Technology
2 shared publicationsChuyan Lin
State Key Laboratory of Oncology in South China Guangdong Provincial Clinical Research Center for Cancer Sun Yat‐sen University Cancer Center Guangzhou P. R. China
2 shared publications
Latest Publications
- Open Access
- 5 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112738
A study on the effects of intrafractional changes in bladder volume on positional accuracy and target dosimetry in online adaptive radiotherapy for cervical cancer
- 5 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112738
Open AccessA study on the effects of intrafractional changes in bladder volume on positional accuracy and target dosimetry in online adaptive radiotherapy for cervical cancer
- Open Access
- 13 March 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (2)
An exploratory study of individualized CTV-PTV expansion margin in thoracic esophageal cancer radiotherapy
- 13 March 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (2)
Open AccessAn exploratory study of individualized CTV-PTV expansion margin in thoracic esophageal cancer radiotherapy
- Open Access
- 8 January 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Comparison of radiation-induced temporal lobe injury after helical tomotherapy versus conventional intensity-modulated radiotherapy for nasopharyngeal carcinoma: a propensity score-matched cohort study
To compare the incidence of radiation-induced temporal lobe injury (TLI) between helical tomotherapy (HT) and conventional intensity-modulated radiotherapy
- 8 January 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Open AccessComparison of radiation-induced temporal lobe injury after helical tomotherapy versus conventional intensity-modulated radiotherapy for nasopharyngeal carcinoma: a propensity score-matched cohort study
To compare the incidence of radiation-induced temporal lobe injury (TLI) between helical tomotherapy (HT) and conventional intensity-modulated radiotherapy
- Open Access
- 4 December 2025
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Dose-dependent taste dysfunction in head and neck cancer patients receiving radiotherapy
This study aimed to investigate the progression of taste dysfunction (TD) in patients with head and neck cancer (HNC) receiving radiotherapy (RT) and to de
- 4 December 2025
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Open AccessDose-dependent taste dysfunction in head and neck cancer patients receiving radiotherapy
This study aimed to investigate the progression of taste dysfunction (TD) in patients with head and neck cancer (HNC) receiving radiotherapy (RT) and to de
- 9 August 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 225, 112083
Breast cancer dose distribution prediction based on deep joint learning
- 9 August 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 225, 112083
Breast cancer dose distribution prediction based on deep joint learning
- Open Access
- 6 June 2025
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 10 (9) , 101819
Artificial Intelligence-Assisted Compressed Sensing Technique Accelerates Magnetic Resonance Imaging Simulation for Head and Neck Cancer Radiation Therapy
- 6 June 2025
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 10 (9) , 101819
Open AccessArtificial Intelligence-Assisted Compressed Sensing Technique Accelerates Magnetic Resonance Imaging Simulation for Head and Neck Cancer Radiation Therapy
- Open Access
- 26 April 2025
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (2)
Feasibility and advantages of markerless positioning guided by SGRT in non-surface tumor radiotherapy: focus on esophageal cancer
- 26 April 2025
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (2)
Open AccessFeasibility and advantages of markerless positioning guided by SGRT in non-surface tumor radiotherapy: focus on esophageal cancer
- Open Access
- 1 January 2025
- Published by SAGE Publications in Clinical Medicine Insights: Oncology
- Vol. 19
The Effect of Bladder and Rectum Volume Changes on Exposed Organ Volume During Intensity-Modulated Radiotherapy for Cervical Cancer
Background: This retrospective cohort study aims to study the changes of the exposed volume of the bladder and rectum under different filling states, and to clarify the influences of the morphing organs on themselves and each other, to provide the basis for reducing the risk of organ damage by intensity-modulated radiotherapy (IMRT) for cervical cancer. Methods: A retrospective analysis was performed on 24 patients with cervical cancer who received IMRT. Before radiotherapy, a comfortably full bladder and active defecation was ensured for all patients, and interative cone-beam computed tomography (iCBCT) was performed to delineate the bladder, rectum, and small intestine. The filling degree of the bladder, rectum, and small intestine and their intersection with the planned target volume were recorded. Results: 83.44% of patients exhibited reduced bladder volume during treatment. When the planned bladder volume was 400–500 cc, the bladder volume changed the least during treatment (F = 58.39, P < .001). The exposed volume of the small intestine was moderately correlated with the degree of bladder filling ( r = −.674, P < .01). For every 10% increase in bladder volume, the exposed volume of the small intestine decreased by 24.05% ( P < .01). Furthermore, 45.83% patients had an increase in rectum volume during treatment. The exposed volume increased by 9.47% for every 10% increase in rectum volume ( P < .01). Conclusion: Comfortable bladder and active defecation regimens may not keep bladder and rectal stability. Targeting a planned bladder volume of 400 to 500cc minimizes intrafraction variability. Strategic bladder filling optimization may mitigate small intestine exposure.
- 1 January 2025
- Published by SAGE Publications in Clinical Medicine Insights: Oncology
- Vol. 19
Open AccessThe Effect of Bladder and Rectum Volume Changes on Exposed Organ Volume During Intensity-Modulated Radiotherapy for Cervical Cancer
Background: This retrospective cohort study aims to study the changes of the exposed volume of the bladder and rectum under different filling states, and to clarify the influences of the morphing organs on themselves and each other, to provide the basis for reducing the risk of organ damage by intensity-modulated radiotherapy (IMRT) for cervical cancer. Methods: A retrospective analysis was performed on 24 patients with cervical cancer who received IMRT. Before radiotherapy, a comfortably full bladder and active defecation was ensured for all patients, and interative cone-beam computed tomography (iCBCT) was performed to delineate the bladder, rectum, and small intestine. The filling degree of the bladder, rectum, and small intestine and their intersection with the planned target volume were recorded. Results: 83.44% of patients exhibited reduced bladder volume during treatment. When the planned bladder volume was 400–500 cc, the bladder volume changed the least during treatment (F = 58.39, P < .001). The exposed volume of the small intestine was moderately correlated with the degree of bladder filling ( r = −.674, P < .01). For every 10% increase in bladder volume, the exposed volume of the small intestine decreased by 24.05% ( P < .01). Furthermore, 45.83% patients had an increase in rectum volume during treatment. The exposed volume increased by 9.47% for every 10% increase in rectum volume ( P < .01). Conclusion: Comfortable bladder and active defecation regimens may not keep bladder and rectal stability. Targeting a planned bladder volume of 400 to 500cc minimizes intrafraction variability. Strategic bladder filling optimization may mitigate small intestine exposure.
- Open Access
- 29 November 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (3) , e14573
Impact of belly board immobilization devices and body mass factor on setup displacement using daily cone‐beam CT in rectal cancer radiotherapy
Objective: The objective of this study is to evaluate the impact of different belly board and daily changes in patient's body‐mass factor (BMF) on setup displacement in radiotherapy for rectal cancer.Methods: Twenty‐five patients were immobilized using the thermoplastic mask with belly board (TM‐BB), and 30 used the vacuum bag cushion with belly board (VBC‐BB), performing daily cone‐beam computed tomography (CBCT) scans 625 times and 750 times, respectively. Daily pretreatment CBCT scans were registered to the planned CT images for BMF change determination and setup displacement measurement. Independent t‐tests compared setup displacement between the two groups in left‐right (LR), superior‐inferior (SI), and anterior‐posterior (AP) directions, as well as the BMF changes. The impact of daily BMF changes on setup displacement was evaluated using multivariate logistic regression and 10‐fold cross‐validation.Results: The setup displacement for TM‐BB in the LR, SI, and AP directions were 0.31 ± 0.25, 0.58 ± 0.40, and 0.19 ± 0.18 cm, respectively, while VBC‐BB showed 0.19 ± 0.15, 0.26 ± 0.22, and 0.36 ± 0.29 cm in the corresponding directions, respectively. Margins of planning target volume (PTV) for TM‐BB were 8, 10, and 6 mm in LR, SI, and AP directions, while VBC‐BB showed margins of 5,7, and 8 mm, respectively. The daily BMF changes for both groups were ranked in descending order as follows: sacral rotation angle (RS), hip lateral diameter (HLD), and hip anterior‐posterior diameter (HAPD). HAPD was the main factor affecting setup displacement in both the AP and SI directions in TM‐BB, while RS was the primary factor for setup displacement in the AP direction in VBC‐BB.Conclusion: Compared with TM‐BB, VBC‐BB had a larger AP displacement but smaller in LR and SI displacement. Daily changes in BMF have distinct effects on setup displacement in different immobilization devices. Image‐guided radiation therapy (IGRT) is highly recommended and BMF changes should be given consideration during radiotherapy.
- 29 November 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (3) , e14573
Open AccessImpact of belly board immobilization devices and body mass factor on setup displacement using daily cone‐beam CT in rectal cancer radiotherapy
Objective: The objective of this study is to evaluate the impact of different belly board and daily changes in patient's body‐mass factor (BMF) on setup displacement in radiotherapy for rectal cancer.Methods: Twenty‐five patients were immobilized using the thermoplastic mask with belly board (TM‐BB), and 30 used the vacuum bag cushion with belly board (VBC‐BB), performing daily cone‐beam computed tomography (CBCT) scans 625 times and 750 times, respectively. Daily pretreatment CBCT scans were registered to the planned CT images for BMF change determination and setup displacement measurement. Independent t‐tests compared setup displacement between the two groups in left‐right (LR), superior‐inferior (SI), and anterior‐posterior (AP) directions, as well as the BMF changes. The impact of daily BMF changes on setup displacement was evaluated using multivariate logistic regression and 10‐fold cross‐validation.Results: The setup displacement for TM‐BB in the LR, SI, and AP directions were 0.31 ± 0.25, 0.58 ± 0.40, and 0.19 ± 0.18 cm, respectively, while VBC‐BB showed 0.19 ± 0.15, 0.26 ± 0.22, and 0.36 ± 0.29 cm in the corresponding directions, respectively. Margins of planning target volume (PTV) for TM‐BB were 8, 10, and 6 mm in LR, SI, and AP directions, while VBC‐BB showed margins of 5,7, and 8 mm, respectively. The daily BMF changes for both groups were ranked in descending order as follows: sacral rotation angle (RS), hip lateral diameter (HLD), and hip anterior‐posterior diameter (HAPD). HAPD was the main factor affecting setup displacement in both the AP and SI directions in TM‐BB, while RS was the primary factor for setup displacement in the AP direction in VBC‐BB.Conclusion: Compared with TM‐BB, VBC‐BB had a larger AP displacement but smaller in LR and SI displacement. Daily changes in BMF have distinct effects on setup displacement in different immobilization devices. Image‐guided radiation therapy (IGRT) is highly recommended and BMF changes should be given consideration during radiotherapy.
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085010
XTransCT: ultra-fast volumetric CT reconstruction using two orthogonal x-ray projections for image-guided radiation therapy via a transformer network
Objective. The aim of this study was to reconstruct volumetric computed tomography (CT) images in real-time from ultra-sparse two-dimensional x-ray projections, facilitating easier navigation and positioning during image-guided radiation therapy. Approach. Our approach leverages a voxel-sapce-searching Transformer model to overcome the limitations of conventional CT reconstruction techniques, which require extensive x-ray projections and lead to high radiation doses and equipment constraints. Main results. The proposed XTransCT algorithm demonstrated superior performance in terms of image quality, structural accuracy, and generalizability across different datasets, including a hospital set of 50 patients, the large-scale public LIDC-IDRI dataset, and the LNDb dataset for cross-validation. Notably, the algorithm achieved an approximately 300% improvement in reconstruction speed, with a rate of 44 ms per 3D image reconstruction compared to former 3D convolution-based methods. Significance. The XTransCT architecture has the potential to impact clinical practice by providing high-quality CT images faster and with substantially reduced radiation exposure for patients. The model's generalizability suggests it has the potential applicable in various healthcare settings.
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085010
XTransCT: ultra-fast volumetric CT reconstruction using two orthogonal x-ray projections for image-guided radiation therapy via a transformer network
Objective. The aim of this study was to reconstruct volumetric computed tomography (CT) images in real-time from ultra-sparse two-dimensional x-ray projections, facilitating easier navigation and positioning during image-guided radiation therapy. Approach. Our approach leverages a voxel-sapce-searching Transformer model to overcome the limitations of conventional CT reconstruction techniques, which require extensive x-ray projections and lead to high radiation doses and equipment constraints. Main results. The proposed XTransCT algorithm demonstrated superior performance in terms of image quality, structural accuracy, and generalizability across different datasets, including a hospital set of 50 patients, the large-scale public LIDC-IDRI dataset, and the LNDb dataset for cross-validation. Notably, the algorithm achieved an approximately 300% improvement in reconstruction speed, with a rate of 44 ms per 3D image reconstruction compared to former 3D convolution-based methods. Significance. The XTransCT architecture has the potential to impact clinical practice by providing high-quality CT images faster and with substantially reduced radiation exposure for patients. The model's generalizability suggests it has the potential applicable in various healthcare settings.