Mahlon Scott Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mahlon Scott Wilson has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Rangachary Mukundan
Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
9 shared publications Eric L. Brosha
8 shared publicationsTommy Rockward
Los Alamos National Laboratory
8 shared publications- Andrew Morgan Baker
Ionomr Innovations Inc
5 shared publications Fernando Garzon
5 shared publicationsJon Rau
Los Alamos National Laboratory
5 shared publications
Latest Publications
- 8 December 2021
- Published by Office of Scientific and Technical Information (OSTI)
ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 8 December 2021
- Published by Office of Scientific and Technical Information (OSTI)
ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 29 May 2020
- Published by Office of Scientific and Technical Information (OSTI)
High Performing and Durable Pyrophosphate Based Composite Membranes for Intermediate Temperature Fuel Cells [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 29 May 2020
- Published by Office of Scientific and Technical Information (OSTI)
High Performing and Durable Pyrophosphate Based Composite Membranes for Intermediate Temperature Fuel Cells [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1483
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
Fuel cells have potential for small power applications that require long periods, as much as several decades, of uninterrupted power. Small microwatt fuel cell stacks of varying membrane thickness were designed to allow for passive water management. The passive water management system was incorporated into the stack design by use of exposed Nafion membrane for lateral water transport. 1 An experimental and theoretical study of water management across the operating temperature range was conduction, including operando neutron imaging and the development of a multiphysics two-dimensional model. Stack testing was done between -55 °C to 85 °C using a baseline output current of 10 µA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s, or an average current of 16 µA. The stack spatial water concentration was monitored during various operating conditions through in situ neutron imaging. Figure 1 shows the main points of interest on the stack. Operating temperatures ranged from -55 °C to 85 °C to analyze water formation and subsequent water removal. Freezing and below-freezing temperatures were controlled by use of a liquid nitrogen cooled series of insulated boxes to prevent external water condensation during imaging. These measurements suggest successful water transport laterally, enabling operation from the sub-freezing environment to temperatures near the boiling point of water. Figure 2a depicts a constant operation for two hours at 16 µA and -20 ºC and the subsequent drying process in Figure 2b. Water production due to gas crossover in the stacks was quantified at below-freezing temperatures. At temperatures at and below -20 °C, the water production due to gas crossover was greater than the amount of water removal via the passive water management strategy with the current turned off, rather than a drying of the cell as expected. With the gases turned off as well, drying occurs. This indicates that the cell design must allow for water (ice) build-up during operation at these sub-freezing temperatures for successful operation. To avoid large amounts of hydrogen loss due to membrane crossover, we employ multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A two-dimensional multiphysics model for evaluation of water management was also developed to further describe and explore the passive water management system under different conditions. The fundamental model in its present form shows a similar shape but indicates faster water build-up than experimental data. This discrepancy is currently being resolved to allow for a more accurate representation. Acknowledgments: This work was supported by the U.S. Department of Energy. References: Chintam, M. S. Wilson, T. Rockward, S. Stariha, A. M. Baker, E. L. Brosha, D. S. Hussey, J. M. LaManna, D. L. Jacobson, J. Rau, R. L. Borup, ECS Transactions 86 (13), 233-244. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1483
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
Fuel cells have potential for small power applications that require long periods, as much as several decades, of uninterrupted power. Small microwatt fuel cell stacks of varying membrane thickness were designed to allow for passive water management. The passive water management system was incorporated into the stack design by use of exposed Nafion membrane for lateral water transport. 1 An experimental and theoretical study of water management across the operating temperature range was conduction, including operando neutron imaging and the development of a multiphysics two-dimensional model. Stack testing was done between -55 °C to 85 °C using a baseline output current of 10 µA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s, or an average current of 16 µA. The stack spatial water concentration was monitored during various operating conditions through in situ neutron imaging. Figure 1 shows the main points of interest on the stack. Operating temperatures ranged from -55 °C to 85 °C to analyze water formation and subsequent water removal. Freezing and below-freezing temperatures were controlled by use of a liquid nitrogen cooled series of insulated boxes to prevent external water condensation during imaging. These measurements suggest successful water transport laterally, enabling operation from the sub-freezing environment to temperatures near the boiling point of water. Figure 2a depicts a constant operation for two hours at 16 µA and -20 ºC and the subsequent drying process in Figure 2b. Water production due to gas crossover in the stacks was quantified at below-freezing temperatures. At temperatures at and below -20 °C, the water production due to gas crossover was greater than the amount of water removal via the passive water management strategy with the current turned off, rather than a drying of the cell as expected. With the gases turned off as well, drying occurs. This indicates that the cell design must allow for water (ice) build-up during operation at these sub-freezing temperatures for successful operation. To avoid large amounts of hydrogen loss due to membrane crossover, we employ multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A two-dimensional multiphysics model for evaluation of water management was also developed to further describe and explore the passive water management system under different conditions. The fundamental model in its present form shows a similar shape but indicates faster water build-up than experimental data. This discrepancy is currently being resolved to allow for a more accurate representation. Acknowledgments: This work was supported by the U.S. Department of Energy. References: Chintam, M. S. Wilson, T. Rockward, S. Stariha, A. M. Baker, E. L. Brosha, D. S. Hussey, J. M. LaManna, D. L. Jacobson, J. Rau, R. L. Borup, ECS Transactions 86 (13), 233-244. Figure 1
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 395-409
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
A small microwatt fuel cell stack with 8 cells was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Two stacks with active areas of 0.2 cm2, one with 200 µm of membrane and the other with 400 µm, were assembled and tested at varying temperatures and current conditions. Temperatures ranged –55 °C to 70 °C, with focus on the lower temperatures. Factors affecting water production and removal included temperature, gas crossover, and membrane thickness. Currents were applied from 16 µA to 10 mA after the cells were stabilized at temperature, followed by a period of drying to observe water transport to the external peripheries of the cell. A two-dimensional multiphysics model was developed to further explore the water management system in varying conditions.
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 395-409
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
A small microwatt fuel cell stack with 8 cells was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Two stacks with active areas of 0.2 cm2, one with 200 µm of membrane and the other with 400 µm, were assembled and tested at varying temperatures and current conditions. Temperatures ranged –55 °C to 70 °C, with focus on the lower temperatures. Factors affecting water production and removal included temperature, gas crossover, and membrane thickness. Currents were applied from 16 µA to 10 mA after the cells were stabilized at temperature, followed by a period of drying to observe water transport to the external peripheries of the cell. A two-dimensional multiphysics model was developed to further explore the water management system in varying conditions.
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (42) , 1415
Microwatt Fuel Cell for Long-Term and Wide Ambient Temperature Range Operation
Micro- to milli-watt fuel cell stacks and systems are designed and tested for applications that require continuous operation for multiple decades and at very wide ambient temperature ranges. Development presumes generic load profiles consisting of small baseline currents with frequent, periodic excursions to higher currents, both delivered at the 3.3 V standard integrated circuit voltage level. Stack design and testing was done between -55˚C to 80˚C using a baseline output current of 10 uA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s. To simplify testing, the stacks are paired with 3.3V output miniature dc-dc converters to supply the respective 33 uW and 15 mW power requirements, with the stack then initially providing about 40 uW and 17 mW reflecting the converter efficiencies at the two sets of output currents/input voltages. Since maximum cell power tends to occur at >0.5 V/cell, 8-cell stacks were chosen so that, if called upon, the maximum power point still exceeds the ~4 V minimum buck converter input. Concerns about air availability and purity impel the use of H2 & O2 reactants; accommodating the fittings and other design constraints lead to a 13x19mm footprint (active area = 0.2 cm2), as shown in Figure 1. Since the stack reactant supplies are “dead-ended”, provision needs to be made to remove product water. In contrast to typical (higher power) fuel cell applications, the primary system challenges with the microwatt system are reactant cross-over and leakage current. As an example of the severity of the issue, a 2020 technical target1 for membrane leakage current is an equivalent DC resistance of 1000 Wcm2. A similar value in this case would yield a cumulative leakage current of about 1.4 mA, causing an otherwise 30 y reactant supply for this system to last less than a year. Moreover, cross-over losses are generally hand-in-hand with leakage. The simple straightforward solution is to use thick membranes, done here primarily by stacking multiple layers of DuPont XL, which provides the benefits of radical scavengers and PTFE reinforcement scrims to enhance long-term chemical and dimensional stability. Other loss mitigation configurations and strategies are being pursued in tandem. The need to provide 17 mW pulses not only limits the maximum membrane thicknesses (and stack resistances), but subjects the individual cells to voltage cycles between about 0.6V and OCV, similar to a catalyst durability AST (accelerated stress test). These issues can be alleviated by pairing the stack with a supercapacitor to minimize the voltage swings during the 17 mW pulses, thus allowing the stack to supply a fairly constant 65 uW (accounting for converter efficiency). Consequently, life and environmental testing are underway to demonstrate the utility of the configuration, but the preferred goal is to achieve the desired results without introducing additional components with potential lifetime and temperature range issues. Long-term room temperature life-testing is underway on stacks with and without supercaps. As of March 2018, a stack subjected to the full 17 mW pulses is approaching 5000 h of operation and has shown little if any drop in performance beyond an initial modest decline. A second stack paired with supercaps has been in operation nearly as long and likewise shows minimal sustained losses, even though it is being subjected to 10x the standard pulse rate. Environmental chamber testing has demonstrated prolonged operation at temperatures ranging from -40˚ to 80˚C. Stack resistance decreases between room and high (80˚C) temperatures, overtly because the proton transport kinetics are enhanced in the already extremely dry membranes. While such dry operation was believed warranted to avoid product water freezing in the catalyst layer causing transport issues, the ability of the stacks to provide 17 mW pulses is challenged by the high stack resistance. Consequently, we have begun investigating the degree to which we can allow water content to increase while maintaining reactant access. Additional future efforts include environmental testing down to -55˚C and further stack design evolution to improve performance and functionality. Figure 1. An 8-cell stack with nitrided titanium bipolar and endplates. Reference 1 DOE Technical Targets for Polymer Electrolyte Membrane Fuel Cell Components. https://www.energy.gov/eere/fuelcells/doe-technical-targets-polymer-electrolyte-membrane-fuel-cell-components Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (42) , 1415
Microwatt Fuel Cell for Long-Term and Wide Ambient Temperature Range Operation
Micro- to milli-watt fuel cell stacks and systems are designed and tested for applications that require continuous operation for multiple decades and at very wide ambient temperature ranges. Development presumes generic load profiles consisting of small baseline currents with frequent, periodic excursions to higher currents, both delivered at the 3.3 V standard integrated circuit voltage level. Stack design and testing was done between -55˚C to 80˚C using a baseline output current of 10 uA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s. To simplify testing, the stacks are paired with 3.3V output miniature dc-dc converters to supply the respective 33 uW and 15 mW power requirements, with the stack then initially providing about 40 uW and 17 mW reflecting the converter efficiencies at the two sets of output currents/input voltages. Since maximum cell power tends to occur at >0.5 V/cell, 8-cell stacks were chosen so that, if called upon, the maximum power point still exceeds the ~4 V minimum buck converter input. Concerns about air availability and purity impel the use of H2 & O2 reactants; accommodating the fittings and other design constraints lead to a 13x19mm footprint (active area = 0.2 cm2), as shown in Figure 1. Since the stack reactant supplies are “dead-ended”, provision needs to be made to remove product water. In contrast to typical (higher power) fuel cell applications, the primary system challenges with the microwatt system are reactant cross-over and leakage current. As an example of the severity of the issue, a 2020 technical target1 for membrane leakage current is an equivalent DC resistance of 1000 Wcm2. A similar value in this case would yield a cumulative leakage current of about 1.4 mA, causing an otherwise 30 y reactant supply for this system to last less than a year. Moreover, cross-over losses are generally hand-in-hand with leakage. The simple straightforward solution is to use thick membranes, done here primarily by stacking multiple layers of DuPont XL, which provides the benefits of radical scavengers and PTFE reinforcement scrims to enhance long-term chemical and dimensional stability. Other loss mitigation configurations and strategies are being pursued in tandem. The need to provide 17 mW pulses not only limits the maximum membrane thicknesses (and stack resistances), but subjects the individual cells to voltage cycles between about 0.6V and OCV, similar to a catalyst durability AST (accelerated stress test). These issues can be alleviated by pairing the stack with a supercapacitor to minimize the voltage swings during the 17 mW pulses, thus allowing the stack to supply a fairly constant 65 uW (accounting for converter efficiency). Consequently, life and environmental testing are underway to demonstrate the utility of the configuration, but the preferred goal is to achieve the desired results without introducing additional components with potential lifetime and temperature range issues. Long-term room temperature life-testing is underway on stacks with and without supercaps. As of March 2018, a stack subjected to the full 17 mW pulses is approaching 5000 h of operation and has shown little if any drop in performance beyond an initial modest decline. A second stack paired with supercaps has been in operation nearly as long and likewise shows minimal sustained losses, even though it is being subjected to 10x the standard pulse rate. Environmental chamber testing has demonstrated prolonged operation at temperatures ranging from -40˚ to 80˚C. Stack resistance decreases between room and high (80˚C) temperatures, overtly because the proton transport kinetics are enhanced in the already extremely dry membranes. While such dry operation was believed warranted to avoid product water freezing in the catalyst layer causing transport issues, the ability of the stacks to provide 17 mW pulses is challenged by the high stack resistance. Consequently, we have begun investigating the degree to which we can allow water content to increase while maintaining reactant access. Additional future efforts include environmental testing down to -55˚C and further stack design evolution to improve performance and functionality. Figure 1. An 8-cell stack with nitrided titanium bipolar and endplates. Reference 1 DOE Technical Targets for Polymer Electrolyte Membrane Fuel Cell Components. https://www.energy.gov/eere/fuelcells/doe-technical-targets-polymer-electrolyte-membrane-fuel-cell-components Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (42) , 1441
CVD Catalyzed PEM Fuel Cell and Electrolyzer Electrodes
Chemical vapor deposition (CVD) is commonly used to deposit metals from volatile precursors, typically by thermal decomposition processes. Papandrew has demonstrated the use of CVD to deposit platinum onto solid acid1 and perfluoroionomer2 electrolytes at relatively modest temperatures, suggesting that acid functionality facilitates the deposition process. Here, the possibility that the electrolyte acidity could provide deposition selectivity over other components such as PTFE and carbon in a typical fuel cell catalyst layer is being investigated. Figure 1 illustrates the original proof-of-concept experiment to demonstrate the preferential deposition of the catalyst on ionomer in favor of the other materials composing a gas diffusion layer (GDL). Here, a spiral of Nafion ionomer initially applied to the microporous side of a GDL is XRF imaged in green by the sulfur K emission line originating from the sulfonate functionality. In the experiment, the microporous side of the spiral impregnated GDL was then masked off and platinum acetylacetonate vapor was introduced to the opposite (uncoated) side of the GDL. As shown in the yellow and red Pt L & M scanning XRF images, the platinum subsequently CVD’d is concentrated at the ionomer locations, indicating the preferential deposition of platinum on ionomer over the other GDL materials. By introducing the Pt precursor vapor by the same pathway that reactants would travel in the fuel cell, in principle the deposited platinum is exclusively in locations with both reactant and ionomer access, conceivably maximizing catalyst utilization. A further benefit of the CVD process is that XRD and TEM both indicate that the Pt particles are uniformly in the 2-3 nm range, thus seemingly promising high mass activities. In practice, the CVD process results in the Pt particles seeded into the ionomer, and with low particle densities many are isolated from one another. Consequently, much of the catalyst in 0.1 mg Pt/cm2 fuel cell cathodes is electronically stranded and the electrochemical surface areas (ECSA’s) are disappointingly low. Experimentation with CVD directly onto membranes indicates that the acidity of the electrolyte is indeed a key factor in the deposition process and selectivity. For example, little to no deposition occurs on membranes in the Na+ form, a feature that may be exploitable in limiting the range of deposition. Physical strategies can also be employed to limit the depth of penetration, such as minimizing ionomer film thickness or by introducing permeation barriers. Further, the CVD conditions are observed to affect the deposition profile. Through various strategies, improvements are being made in the fuel cell catalyst utilization. If the amount of precursor is increased for CVD’ing directly onto membranes, Pt particle density and connectivity likewise increase and eventually silvering of the membrane surface occurs. Because of the interpenetrating nature of the catalyst and ionomer networks, it may be possible that highly effective electrodes can be achieved with such configurations in cases where gaseous reactant access is not key, such as in water electrolysis. Consequently, efforts are underway to see if it is possible to prepare iridium and platinum catalyzed membrane electrodes with “low” loadings (< 1 mg/cm2) that also provide sufficient particle density and connectivity to yield high electrolyzer catalyst utilizations. Figure 1. Scanning XRF images showing the signatures of an ionomer spiral (Sulfur K) impregnated into the microporous layer of a GDL, and of the subsequently CVD’d platinum (L & M lines). Acknowledgments Funding was provided by the U.S. Department of Energy, Fuel Cell Technologies Office, and by the Los Alamos National Laboratory LDRD (Laboratory Directed R&D) Program. References 1A. B. Papandrew, C.R.I. Chisholm, S. K. Zecevic, G.M. Veith, and T.A. Zawodzinski, J. Electrochem. Soc., 160, (2), F175-F182 (2013) 2S. Komini Babu, R.W. Atkinson, A.B. Papandrew, and S. Lister, Chem. ElectroChem., 2, 1752-1759 (2015) Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (42) , 1441
CVD Catalyzed PEM Fuel Cell and Electrolyzer Electrodes
Chemical vapor deposition (CVD) is commonly used to deposit metals from volatile precursors, typically by thermal decomposition processes. Papandrew has demonstrated the use of CVD to deposit platinum onto solid acid1 and perfluoroionomer2 electrolytes at relatively modest temperatures, suggesting that acid functionality facilitates the deposition process. Here, the possibility that the electrolyte acidity could provide deposition selectivity over other components such as PTFE and carbon in a typical fuel cell catalyst layer is being investigated. Figure 1 illustrates the original proof-of-concept experiment to demonstrate the preferential deposition of the catalyst on ionomer in favor of the other materials composing a gas diffusion layer (GDL). Here, a spiral of Nafion ionomer initially applied to the microporous side of a GDL is XRF imaged in green by the sulfur K emission line originating from the sulfonate functionality. In the experiment, the microporous side of the spiral impregnated GDL was then masked off and platinum acetylacetonate vapor was introduced to the opposite (uncoated) side of the GDL. As shown in the yellow and red Pt L & M scanning XRF images, the platinum subsequently CVD’d is concentrated at the ionomer locations, indicating the preferential deposition of platinum on ionomer over the other GDL materials. By introducing the Pt precursor vapor by the same pathway that reactants would travel in the fuel cell, in principle the deposited platinum is exclusively in locations with both reactant and ionomer access, conceivably maximizing catalyst utilization. A further benefit of the CVD process is that XRD and TEM both indicate that the Pt particles are uniformly in the 2-3 nm range, thus seemingly promising high mass activities. In practice, the CVD process results in the Pt particles seeded into the ionomer, and with low particle densities many are isolated from one another. Consequently, much of the catalyst in 0.1 mg Pt/cm2 fuel cell cathodes is electronically stranded and the electrochemical surface areas (ECSA’s) are disappointingly low. Experimentation with CVD directly onto membranes indicates that the acidity of the electrolyte is indeed a key factor in the deposition process and selectivity. For example, little to no deposition occurs on membranes in the Na+ form, a feature that may be exploitable in limiting the range of deposition. Physical strategies can also be employed to limit the depth of penetration, such as minimizing ionomer film thickness or by introducing permeation barriers. Further, the CVD conditions are observed to affect the deposition profile. Through various strategies, improvements are being made in the fuel cell catalyst utilization. If the amount of precursor is increased for CVD’ing directly onto membranes, Pt particle density and connectivity likewise increase and eventually silvering of the membrane surface occurs. Because of the interpenetrating nature of the catalyst and ionomer networks, it may be possible that highly effective electrodes can be achieved with such configurations in cases where gaseous reactant access is not key, such as in water electrolysis. Consequently, efforts are underway to see if it is possible to prepare iridium and platinum catalyzed membrane electrodes with “low” loadings (< 1 mg/cm2) that also provide sufficient particle density and connectivity to yield high electrolyzer catalyst utilizations. Figure 1. Scanning XRF images showing the signatures of an ionomer spiral (Sulfur K) impregnated into the microporous layer of a GDL, and of the subsequently CVD’d platinum (L & M lines). Acknowledgments Funding was provided by the U.S. Department of Energy, Fuel Cell Technologies Office, and by the Los Alamos National Laboratory LDRD (Laboratory Directed R&D) Program. References 1A. B. Papandrew, C.R.I. Chisholm, S. K. Zecevic, G.M. Veith, and T.A. Zawodzinski, J. Electrochem. Soc., 160, (2), F175-F182 (2013) 2S. Komini Babu, R.W. Atkinson, A.B. Papandrew, and S. Lister, Chem. ElectroChem., 2, 1752-1759 (2015) Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (44) , 1510
Durability of Long-Life Low Power Fuel Cells
Fuel cells have the potential to provide very low uninterrupted power for long periods (several decades) of time. The specifications for these applications can vary tremendously from transportation fuel cells that are a large driving force behind fuel cell development. For these applications, the fuel and oxidant supply are often required to be stored for the entire lifetime of the application; these systems have higher inherent safety and overall higher system energy density than batteries for these prolonged operational times. Many of the technical challenges are application dependent but can include: Fuel/oxidant loss (due to membrane/plates/seals permeability) Membrane degradation and thinning (due to high cell voltages) Passive system water management Operation in uncontrolled environments (including operation a large temperature range and unpredictable/uncontrollable ambient atmospheres) Control of power transients (microwatt to watt power levels) The primary degradation modes expected for these applications involve the electrode layer, loss of catalytic activity, membrane thinning, changing hydrophobicity of carbon materials (which impacts water management) and corrosion of metallic bipolar plates (including increasing contact resistance). Electrode degradation involving performance loss of the cathode catalyst layer includes catalyst particle agglomeration, catalyst support corrosion, losses of catalyst layer porosity and loss of catalyst layer proton conductivity due to ionomer degradation. Depending on the systems load requirements, potential cycles can be many millions of cycles over decades long continuous operation. To minimize catalyst degradation, we expect that a Pt-black electrode will be superior compare to the Pt supported on carbon electrodes that are the preferred for transportation applications. To examine the durability of these catalysts we are conducting Accelerated Stress Testing (ASTs); Figure 1 shows an on-going test of a Pt-black catalyst over 1.3 million cycles. The square wave cycling induces Pt dissolution and re-precipitation (Ostwald ripening) of the platinum thus decreases the catalyst surface area. From Figure 1, catalyst surface area loss appears to have reached 30-35% loss, but has not substantially increased after about 750,000 cycles. To avoid large amounts of hydrogen loss due to membrane cross-over, we are exploring multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A primary method to examine membrane degradation is to examine radical attack of the membrane at OCV conditions. Membrane thinning was measured at approximately 1.7 - 4.2 micron/year over a 2.4 year test with H2/air, at 25 C, which over a 20 year operational life extrapolates to34 - 83 micron. This suggests that a membrane of > 200 micron thick will be required for a 20 year operational life at low power levels. Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-02 (44) , 1510
Durability of Long-Life Low Power Fuel Cells
Fuel cells have the potential to provide very low uninterrupted power for long periods (several decades) of time. The specifications for these applications can vary tremendously from transportation fuel cells that are a large driving force behind fuel cell development. For these applications, the fuel and oxidant supply are often required to be stored for the entire lifetime of the application; these systems have higher inherent safety and overall higher system energy density than batteries for these prolonged operational times. Many of the technical challenges are application dependent but can include: Fuel/oxidant loss (due to membrane/plates/seals permeability) Membrane degradation and thinning (due to high cell voltages) Passive system water management Operation in uncontrolled environments (including operation a large temperature range and unpredictable/uncontrollable ambient atmospheres) Control of power transients (microwatt to watt power levels) The primary degradation modes expected for these applications involve the electrode layer, loss of catalytic activity, membrane thinning, changing hydrophobicity of carbon materials (which impacts water management) and corrosion of metallic bipolar plates (including increasing contact resistance). Electrode degradation involving performance loss of the cathode catalyst layer includes catalyst particle agglomeration, catalyst support corrosion, losses of catalyst layer porosity and loss of catalyst layer proton conductivity due to ionomer degradation. Depending on the systems load requirements, potential cycles can be many millions of cycles over decades long continuous operation. To minimize catalyst degradation, we expect that a Pt-black electrode will be superior compare to the Pt supported on carbon electrodes that are the preferred for transportation applications. To examine the durability of these catalysts we are conducting Accelerated Stress Testing (ASTs); Figure 1 shows an on-going test of a Pt-black catalyst over 1.3 million cycles. The square wave cycling induces Pt dissolution and re-precipitation (Ostwald ripening) of the platinum thus decreases the catalyst surface area. From Figure 1, catalyst surface area loss appears to have reached 30-35% loss, but has not substantially increased after about 750,000 cycles. To avoid large amounts of hydrogen loss due to membrane cross-over, we are exploring multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A primary method to examine membrane degradation is to examine radical attack of the membrane at OCV conditions. Membrane thinning was measured at approximately 1.7 - 4.2 micron/year over a 2.4 year test with H2/air, at 25 C, which over a 20 year operational life extrapolates to34 - 83 micron. This suggests that a membrane of > 200 micron thick will be required for a 20 year operational life at low power levels. Figure 1
- 23 July 2018
- Published by The Electrochemical Society in ECS Transactions
- Vol. 86 (13) , 233-244
Microwatt Fuel Cell for Long-Term and Wide Ambient Temperature Range Operation
A small microwatt fuel cell stack and system was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Additional requirements for decades long operation is minimizing H2 and O2 consumption, specifically membrane cross-over; to minimize cross-over, stacks were built with layered membranes of 100 µm and 400 µm. The stack spatial water concentration level was monitored during operation by in situ neutron imaging to evaluate the passive water management design. Operation was verified by testing at temperatures ranging from -55 °C to 80 °C, including periodic pulses in power.
- 23 July 2018
- Published by The Electrochemical Society in ECS Transactions
- Vol. 86 (13) , 233-244
Microwatt Fuel Cell for Long-Term and Wide Ambient Temperature Range Operation
A small microwatt fuel cell stack and system was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Additional requirements for decades long operation is minimizing H2 and O2 consumption, specifically membrane cross-over; to minimize cross-over, stacks were built with layered membranes of 100 µm and 400 µm. The stack spatial water concentration level was monitored during operation by in situ neutron imaging to evaluate the passive water management design. Operation was verified by testing at temperatures ranging from -55 °C to 80 °C, including periodic pulses in power.
- 1 March 2018
- Published by Royal Society of Chemistry (RSC) in Energy & Environmental Science
- Vol. 11 (4) , 979-987
Intermediate temperature fuel cells via an ion-pair coordinated polymer electrolyte
High performance of SnP2O7-based intermediate temperature fuel cells was obtained with a quaternary ammonium-biphosphate ion-pair coordinated polymer electrolyte.
- 1 March 2018
- Published by Royal Society of Chemistry (RSC) in Energy & Environmental Science
- Vol. 11 (4) , 979-987
Intermediate temperature fuel cells via an ion-pair coordinated polymer electrolyte
High performance of SnP2O7-based intermediate temperature fuel cells was obtained with a quaternary ammonium-biphosphate ion-pair coordinated polymer electrolyte.
- 6 February 2018
- Published by Office of Scientific and Technical Information (OSTI)
CSTT Update: Fuel Quality Analyzer
These are slides from a presentation. The following topics are covered: project background (scope and approach), developing the prototype (timeline), update on intellectual property, analyzer comparisons (improving humidification, stabilizing the baseline, applying clean-up strategy, impact of ionomer content and improving clean-up), proposed operating mode, considerations for testing in real-world conditions (Gen 1 analyzer electronics development, testing partner identified, field trial planning), summary, and future work.
- 6 February 2018
- Published by Office of Scientific and Technical Information (OSTI)
CSTT Update: Fuel Quality Analyzer
These are slides from a presentation. The following topics are covered: project background (scope and approach), developing the prototype (timeline), update on intellectual property, analyzer comparisons (improving humidification, stabilizing the baseline, applying clean-up strategy, impact of ionomer content and improving clean-up), proposed operating mode, considerations for testing in real-world conditions (Gen 1 analyzer electronics development, testing partner identified, field trial planning), summary, and future work.