Andrew Morgan Baker
Research Subjects
Research Interests
Andrew Morgan Baker has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
Rod L. Borup
Los Alamos National Laboratory
18 shared publicationsRangachary Mukundan
Los Alamos National Laboratory
11 shared publicationsKavitha Chintam
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, United States
8 shared publicationsAjay K. Prasad
University of Delaware
7 shared publicationsDusan Spernjak
Los Alamos National Laboratory
7 shared publications- Rangachary Mukundan
Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
7 shared publications
Latest Publications
- Open Access
- 9 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (4)
Effect of Humidification on the Ionomer-Catalyst Interactions of Sulfo-Phenylated Polyphenylene Ionomers in PEMFCs
Ionomer-catalyst interactions in polymer electrolyte membrane fuel cells (PEMFCs) are studied for sulfo-phenylated polyphenylene (sPPP) ionomers using CO displacement/stripping and oxygen (O2) transport resistance. We find that sPPP ionomers demonstrate low sulfonic acid group adsorption on platinum (~2%) at both dry and super-saturated humidities. This low ionomer adsorption appears to be driven by the ionomer’s strong swelling character with hydration, leading to ionomer detachment from the catalyst surface under these conditions. We also report that O2 transport resistance is lower for electrodes containing sPPP ionomers by a factor of three compared to standard perfluorosulfonic acid (PFSA) ionomers. While PFSA thin films have been shown to rearrange over platinum sites, this effect may be limited in sPPP electrodes due to the rigidity of the backbone.
- 9 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (4)
Open AccessEffect of Humidification on the Ionomer-Catalyst Interactions of Sulfo-Phenylated Polyphenylene Ionomers in PEMFCs
Ionomer-catalyst interactions in polymer electrolyte membrane fuel cells (PEMFCs) are studied for sulfo-phenylated polyphenylene (sPPP) ionomers using CO displacement/stripping and oxygen (O2) transport resistance. We find that sPPP ionomers demonstrate low sulfonic acid group adsorption on platinum (~2%) at both dry and super-saturated humidities. This low ionomer adsorption appears to be driven by the ionomer’s strong swelling character with hydration, leading to ionomer detachment from the catalyst surface under these conditions. We also report that O2 transport resistance is lower for electrodes containing sPPP ionomers by a factor of three compared to standard perfluorosulfonic acid (PFSA) ionomers. While PFSA thin films have been shown to rearrange over platinum sites, this effect may be limited in sPPP electrodes due to the rigidity of the backbone.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (40) , 1955
Thin Film Oxygen Transport and Sulfonic Acid Group Adsorption in PEMFC Electrodes Containing Sulfo-Phenylated Polyphenylene Ionomers
In recent years, hydrocarbon ionomers, particularly sulfo-phenylated polyphenylenes (sPPP), have emerged as a potential competitor to established per-fluorinated sulfonic acid (PFSA) ionomers for both membrane and electrode applications. Compared to PFSA materials, sPPP ionomers exhibit much lower equivalent weights (EW), higher resistance to gas diffusion in bulk media, and significantly higher water uptake. Despite the promise of these materials, critical gaps in understanding of ionomer thin film properties and the ionomer-catalyst interface remain a barrier to wider deployment. Our group investigated thin film oxygen diffusion and sulfonic acid group adsorption for both sPPP and Nafion electrodes using oxygen transport resistance and CO displacement and stripping experiments. We report that for sPPP electrodes, local oxygen transport resistance, taken at 80% relative humidity (RH), is approximately one-third that corresponding to Nafion. We hypothesize that this difference is attributable to the bulky ionomer backbone, which may prevent preferential rearrangement over catalyst sites, similar to HOPI ionomers for PFSA. We also report that sPPP ionomers demonstrate a starkly different sulfonic acid group adsorption behavior than Nafion. While Nafion electrodes exhibit increased adsorption as relative humidity decreases, sPPP electrodes instead show a bell-shaped adsorption curve, with very low adsorption (~2%) at both dry and super-saturated conditions. This change in behavior between the ionomers is driven by the displacement charge, which is a result of the adsorbed sulfonic acid moieties being removed from the surface by adsorbing CO. Nafion electrodes exhibit a relatively flat displacement response while sPPP ionomers exhibit a bell-like shape with a maximum at 100% RH. We hypothesize that the cause of this difference for sPPP electrodes is driven by ionomer detachment from the surface of the catalyst at extreme hydration states. This is likely caused by a combination of higher dimensional swelling/shrinking with changing humidity as well as weaker attachment to the surface of the platinum due to the absence of fluorine on the polymer backbone. Further work, including computational studies, will be needed to investigate the ionomer configuration close to the catalyst surface.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (40) , 1955
Thin Film Oxygen Transport and Sulfonic Acid Group Adsorption in PEMFC Electrodes Containing Sulfo-Phenylated Polyphenylene Ionomers
In recent years, hydrocarbon ionomers, particularly sulfo-phenylated polyphenylenes (sPPP), have emerged as a potential competitor to established per-fluorinated sulfonic acid (PFSA) ionomers for both membrane and electrode applications. Compared to PFSA materials, sPPP ionomers exhibit much lower equivalent weights (EW), higher resistance to gas diffusion in bulk media, and significantly higher water uptake. Despite the promise of these materials, critical gaps in understanding of ionomer thin film properties and the ionomer-catalyst interface remain a barrier to wider deployment. Our group investigated thin film oxygen diffusion and sulfonic acid group adsorption for both sPPP and Nafion electrodes using oxygen transport resistance and CO displacement and stripping experiments. We report that for sPPP electrodes, local oxygen transport resistance, taken at 80% relative humidity (RH), is approximately one-third that corresponding to Nafion. We hypothesize that this difference is attributable to the bulky ionomer backbone, which may prevent preferential rearrangement over catalyst sites, similar to HOPI ionomers for PFSA. We also report that sPPP ionomers demonstrate a starkly different sulfonic acid group adsorption behavior than Nafion. While Nafion electrodes exhibit increased adsorption as relative humidity decreases, sPPP electrodes instead show a bell-shaped adsorption curve, with very low adsorption (~2%) at both dry and super-saturated conditions. This change in behavior between the ionomers is driven by the displacement charge, which is a result of the adsorbed sulfonic acid moieties being removed from the surface by adsorbing CO. Nafion electrodes exhibit a relatively flat displacement response while sPPP ionomers exhibit a bell-like shape with a maximum at 100% RH. We hypothesize that the cause of this difference for sPPP electrodes is driven by ionomer detachment from the surface of the catalyst at extreme hydration states. This is likely caused by a combination of higher dimensional swelling/shrinking with changing humidity as well as weaker attachment to the surface of the platinum due to the absence of fluorine on the polymer backbone. Further work, including computational studies, will be needed to investigate the ionomer configuration close to the catalyst surface.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (38) , 1851
(Invited) Design Considerations for Hydrocarbon Catalyst Layers in Proton- and Alkaline Anion-Exchange Membrane Water Electrolysis
Water electrolysis for the production of green hydrogen is a critical technology for the renewable energy transition, representing the most economic and scalable technology for multi-day energy and inter-regional energy storage, and in pure or in derivative forms is essential to the decarbonization of ammonia, steel, ‘heavy duty’ transportation, and other ‘difficult to abate’ sectors. Commercial electrochemical systems overwhelmingly rely on perfluorosulfonic acids (PFSAs). With respect to electrodes, balancing high conductivity with mechanical properties when fully hydrated provides a key design challenge, especially with desired operating conditions increasing beyond 80 °C, as is small molecule perfluoroalkyl acid effluent in operation and end-of-life catalyst recovery. Hydrocarbon (i.e. non-fluorinated / non-PFAS) ionomers based on sulfonated polyphenylene (sPP) chemistries offer high chemical stability in fuel cell conditions, providing some indication of suitability for electrolysis [1] and a relative invariance of critical properties as a function of operating temperature, especially providing the desired tolerance to high temperatures, i.e. ≥90 °C [2] and potentially up to 180 °C. Hydrocarbon ionomers prevalently require high-boiling solvents, which even in minute quantities strongly affects ionomer morphology in electrode deposition and significantly challenges reproducibility [3], but high ion-exchange capacity materials such as Pemion® provide solubility in desired low-boiling, green solvents. Hydrocarbon electrodes with high ion-exchange capacities must balance conductivity and swelling behaviour with the concomitant reduction in mechanical properties as a function of hydration. While a challenge to decal-tranfer, high Tg/Tα ionomers enable the rational, reproducible structuring of layers within electrodes to address these challenges [4]. Specific to fuel cells, recent in-situ results from sPP suggest the ‘agglomerate model’ for triple-phase boundary may be effected with by a combination of polymer properties and electrode design & deposition. Mechanically sound and electrochemically efficient catalyst layers based on the hydrocarbon ionomer properties will be discussed, with evaluation of ion-exchange capacities, molecular volumes, and swelling properties in addition to interactions with the supported electrocatalyst and porous transport layers and gas-diffusion layers. Alkaline anion-exchange membrane water electrolyzers are also a critical technology for the cost reduction of this green hydrogen, as has been suggested by the European Union’s Clean Hydrogen Joint Undertaking multi-annual work plan cost targets for this technology representing a >35% stack cost reduction at volume. This target is substantiated by the elimination of iridium, titanium, and precious metals-coated components c.f. proton-exchange membrane water electrolysis. Compared to alkaline systems, these can achieve markedly smaller stack sizes and use long-lived nickel coatings for pressurized operation. The presence of a membrane allows for the development of full-area electrodes based on porous transport layers (PTLs) rather than mesh electrodes with majority open area. The requirements for ionomer operating in electrolyte have only recently been due to the development of commercial caustic-stable ionomers such as Aemion® [5]. Recent guidance in system design suggests a larger role of cathode design in safe and effective operation than previously thought [6]. A comparison of strategies for PTL-based electrode design will be discussed across a range of ionomer properties and deposition strategies, with comparison to ionomer-free designs. [1] M. Adamski, N. Peressin, S. Holdcroft, “On the evolution of sulfonated polyphenylenes as proton exchange membranes for fuel cells,” Mater. Adv., 2, 4966-5005 (2021). [2] S.H. Mirfarsi, A. Kumar, J. Jeong, M. Adamski, S. McDermid, B. Britton, E. Kjeang, “High-temperature stability of hydrocarbon-based Pemion® proton exchange membranes: A thermo-mechanical stability study,” Int. J. Hydrogen Energy, 50 B, 1507-1522 (2024). [3] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.F. Lee, W.Y. Huang, S. Holdcroft, “Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers,” J. Electrochem. Soc., 162, F513ff. (2015). [4] H. Nguyen, D. Sultanova, P.A. Heizmann, S. Vierrath, M. Breitwieser, “Improving the efficiency of fully hydrocarbonbased proton-exchange membrane fuel cells by ionomer content gradients in cathode catalyst layers,” Mater. Adv., 3, 8460ff (2022). [5] M. Moreno-González, P. Mardle, S. Zhu, B. Gholamkhass, S. Jones, N. Chen, B. Britton, S. Holdcroft, “One year operation of an anion exchange membrane water electrolyzer utilizing Aemion+® membrane: Minimal degradation, low H2 crossover and high efficiency”, J. Power Sources Adv., 19, 100109 (2023). [6] A. Klinger, O. Strobl, H. Michaels, M. Kress, N. Martic, A. Maltenberger, B. Britton, A. Belletti, R. Eichel, G. Schmid, “Transport of Hydrogen Through Anion Exchange Membranes in Water Electrolysis,” Adv. Mater. Interfaces, In press (2024).
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (38) , 1851
(Invited) Design Considerations for Hydrocarbon Catalyst Layers in Proton- and Alkaline Anion-Exchange Membrane Water Electrolysis
Water electrolysis for the production of green hydrogen is a critical technology for the renewable energy transition, representing the most economic and scalable technology for multi-day energy and inter-regional energy storage, and in pure or in derivative forms is essential to the decarbonization of ammonia, steel, ‘heavy duty’ transportation, and other ‘difficult to abate’ sectors. Commercial electrochemical systems overwhelmingly rely on perfluorosulfonic acids (PFSAs). With respect to electrodes, balancing high conductivity with mechanical properties when fully hydrated provides a key design challenge, especially with desired operating conditions increasing beyond 80 °C, as is small molecule perfluoroalkyl acid effluent in operation and end-of-life catalyst recovery. Hydrocarbon (i.e. non-fluorinated / non-PFAS) ionomers based on sulfonated polyphenylene (sPP) chemistries offer high chemical stability in fuel cell conditions, providing some indication of suitability for electrolysis [1] and a relative invariance of critical properties as a function of operating temperature, especially providing the desired tolerance to high temperatures, i.e. ≥90 °C [2] and potentially up to 180 °C. Hydrocarbon ionomers prevalently require high-boiling solvents, which even in minute quantities strongly affects ionomer morphology in electrode deposition and significantly challenges reproducibility [3], but high ion-exchange capacity materials such as Pemion® provide solubility in desired low-boiling, green solvents. Hydrocarbon electrodes with high ion-exchange capacities must balance conductivity and swelling behaviour with the concomitant reduction in mechanical properties as a function of hydration. While a challenge to decal-tranfer, high Tg/Tα ionomers enable the rational, reproducible structuring of layers within electrodes to address these challenges [4]. Specific to fuel cells, recent in-situ results from sPP suggest the ‘agglomerate model’ for triple-phase boundary may be effected with by a combination of polymer properties and electrode design & deposition. Mechanically sound and electrochemically efficient catalyst layers based on the hydrocarbon ionomer properties will be discussed, with evaluation of ion-exchange capacities, molecular volumes, and swelling properties in addition to interactions with the supported electrocatalyst and porous transport layers and gas-diffusion layers. Alkaline anion-exchange membrane water electrolyzers are also a critical technology for the cost reduction of this green hydrogen, as has been suggested by the European Union’s Clean Hydrogen Joint Undertaking multi-annual work plan cost targets for this technology representing a >35% stack cost reduction at volume. This target is substantiated by the elimination of iridium, titanium, and precious metals-coated components c.f. proton-exchange membrane water electrolysis. Compared to alkaline systems, these can achieve markedly smaller stack sizes and use long-lived nickel coatings for pressurized operation. The presence of a membrane allows for the development of full-area electrodes based on porous transport layers (PTLs) rather than mesh electrodes with majority open area. The requirements for ionomer operating in electrolyte have only recently been due to the development of commercial caustic-stable ionomers such as Aemion® [5]. Recent guidance in system design suggests a larger role of cathode design in safe and effective operation than previously thought [6]. A comparison of strategies for PTL-based electrode design will be discussed across a range of ionomer properties and deposition strategies, with comparison to ionomer-free designs. [1] M. Adamski, N. Peressin, S. Holdcroft, “On the evolution of sulfonated polyphenylenes as proton exchange membranes for fuel cells,” Mater. Adv., 2, 4966-5005 (2021). [2] S.H. Mirfarsi, A. Kumar, J. Jeong, M. Adamski, S. McDermid, B. Britton, E. Kjeang, “High-temperature stability of hydrocarbon-based Pemion® proton exchange membranes: A thermo-mechanical stability study,” Int. J. Hydrogen Energy, 50 B, 1507-1522 (2024). [3] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.F. Lee, W.Y. Huang, S. Holdcroft, “Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers,” J. Electrochem. Soc., 162, F513ff. (2015). [4] H. Nguyen, D. Sultanova, P.A. Heizmann, S. Vierrath, M. Breitwieser, “Improving the efficiency of fully hydrocarbonbased proton-exchange membrane fuel cells by ionomer content gradients in cathode catalyst layers,” Mater. Adv., 3, 8460ff (2022). [5] M. Moreno-González, P. Mardle, S. Zhu, B. Gholamkhass, S. Jones, N. Chen, B. Britton, S. Holdcroft, “One year operation of an anion exchange membrane water electrolyzer utilizing Aemion+® membrane: Minimal degradation, low H2 crossover and high efficiency”, J. Power Sources Adv., 19, 100109 (2023). [6] A. Klinger, O. Strobl, H. Michaels, M. Kress, N. Martic, A. Maltenberger, B. Britton, A. Belletti, R. Eichel, G. Schmid, “Transport of Hydrogen Through Anion Exchange Membranes in Water Electrolysis,” Adv. Mater. Interfaces, In press (2024).
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (7) , 759
(Invited) Mechanical Properties in the Design of Hydrocarbon Catalyst Layers for Electrolyzer, Fuel Cell, and Other Electrochemical Applications with Pemion® and Aemion®
Water electrolysis for the production of green hydrogen is a critical technology for the renewable energy transition, representing the most economic and scalable technology for multi-day energy and inter-regional energy storage, and in pure or in derivative forms is essential to the decarbonization of ammonia, steel, ‘heavy duty’ transportation such as commercial trucking, aviation, shipping, remote operations, the replacement of diesel generators, and other ‘difficult to abate’ sectors. Where practical, hydrogen fuel cells represent the most efficient use of hydrogen. Commercial electrochemical systems overwhelmingly rely on perfluorosulfonic acids (PFSAs). With respect to electrodes, balancing high conductivity with mechanical properties when fully hydrated provides a key design challenge, especially with desired operating conditions increasing beyond 80 °C, as is small molecule perfluoroalkyl acid effluent in operation and end-of-life catalyst recovery. Hydrocarbon (i.e. non-fluorinated / non-PFAS) ionomers based on sulfonated polyphenylene (sPP) chemistries offer a potential replacement for both membrane and ionomer in the catalyst layers of PEM systems. Exhibiting high chemical stability in fuel cell conditions provides an indication of suitability for electrolysis [1], as does a relative invariance of critical properties as a function of operating temperature, especially >80 °C [2]. Hydrocarbon ionomers prevalently require high-boiling solvents, which even in minute quantities strongly affect electrode morphology and reproducibility [3], but high ion-exchange capacity materials such as Pemion® provide solubility in desired low-boiling, green solvents. Hydrocarbon electrodes with high ion-exchange capacities must balance conductivity and swelling behaviour with the concomitant reduction in mechanical properties as a function of hydration. While a challenge to decal-tranfer, high Tg/Tα ionomers enable the rational, reproducible structuring of layers within electrodes to address these challenges [4]. Specific to fuel cells, recent in-situ results from sPP suggest the ‘agglomerate model’ for triple-phase boundary may be effected with by a combination of polymer properties and electrode design & deposition. Mechanically sound and electrochemically efficient catalyst layers based on the hydrocarbon ionomer properties will be discussed, with evaluation of ion-exchange capacities, molecular volumes, and swelling properties in addition to interactions with the supported electrocatalyst and porous transport layers and gas-diffusion layers. Alkaline anion-exchange membrane water electrolyzers are also a critical technology for the cost reduction of this green hydrogen, as has been suggested by the European Union’s Clean Hydrogen Joint Undertaking multi-annual work plan cost targets for this technology representing a >35% stack cost reduction at volume. This target is substantiated by the elimination of iridium, titanium, and precious metals-coated components c.f. proton-exchange membrane water electrolysis. Compared to alkaline systems, these can achieve markedly smaller stack sizes and use long-lived nickel coatings for pressurized operation. The presence of a membrane allows for the development of full-area electrodes based on porous transport layers (PTLs) rather than mesh electrodes. The requirements for ionomer operating in electrolyte have only recently been due to the development of commercial caustic-stable ionomers such as Aemion® [5], and in particular to the anode suggest balancing electrode cohesion and free volume. Recent guidance in system design suggests a larger role of cathode design in safe and effective operation than previously thought [6]. A comparison of strategies for PTL-based electrode design will be discussed across a range of ionomer properties, catalyst ink processing, and electrode deposition strategies, with comparison to ionomer-free designs. [1] M. Adamski, N. Peressin, S. Holdcroft, “On the evolution of sulfonated polyphenylenes as proton exchange membranes for fuel cells,” Mater. Adv., 2, 4966-5005 (2021). [2] S.H. Mirfarsi, A. Kumar, J. Jeong, M. Adamski, S. McDermid, B. Britton, E. Kjeang, “High-temperature stability of hydrocarbon-based Pemion® proton exchange membranes: A thermo-mechanical stability study,” Int. J. Hydrogen Energy, 50 B, 1507-1522 (2024). [3] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.F. Lee, W.Y. Huang, S. Holdcroft, “Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers,” J. Electrochem. Soc., 162, F513ff. (2015). [4] H. Nguyen, D. Sultanova, P.A. Heizmann, S. Vierrath, M. Breitwieser, “Improving the efficiency of fully hydrocarbonbased proton-exchange membrane fuel cells by ionomer content gradients in cathode catalyst layers,” Mater. Adv., 3, 8460ff (2022). [5] M. Moreno-González, P. Mardle, S. Zhu, B. Gholamkhass, S. Jones, N. Chen, B. Britton, S. Holdcroft, “One year operation of an anion exchange membrane water electrolyzer utilizing Aemion+® membrane: Minimal degradation, low H2 crossover and high efficiency”, J. Power Sources Adv., 19, 100109 (2023). [6] A. Klinger, O. Strobl, H. Michaels, M. Kress, N. Martic, A. Maltenberger, B. Britton, A. Belletti, R. Eichel, G. Schmid, “Transport of Hydrogen Through Anion Exchange Membranes in Water Electrolysis,” Adv. Mater. Interfaces, In press (2024).
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (7) , 759
(Invited) Mechanical Properties in the Design of Hydrocarbon Catalyst Layers for Electrolyzer, Fuel Cell, and Other Electrochemical Applications with Pemion® and Aemion®
Water electrolysis for the production of green hydrogen is a critical technology for the renewable energy transition, representing the most economic and scalable technology for multi-day energy and inter-regional energy storage, and in pure or in derivative forms is essential to the decarbonization of ammonia, steel, ‘heavy duty’ transportation such as commercial trucking, aviation, shipping, remote operations, the replacement of diesel generators, and other ‘difficult to abate’ sectors. Where practical, hydrogen fuel cells represent the most efficient use of hydrogen. Commercial electrochemical systems overwhelmingly rely on perfluorosulfonic acids (PFSAs). With respect to electrodes, balancing high conductivity with mechanical properties when fully hydrated provides a key design challenge, especially with desired operating conditions increasing beyond 80 °C, as is small molecule perfluoroalkyl acid effluent in operation and end-of-life catalyst recovery. Hydrocarbon (i.e. non-fluorinated / non-PFAS) ionomers based on sulfonated polyphenylene (sPP) chemistries offer a potential replacement for both membrane and ionomer in the catalyst layers of PEM systems. Exhibiting high chemical stability in fuel cell conditions provides an indication of suitability for electrolysis [1], as does a relative invariance of critical properties as a function of operating temperature, especially >80 °C [2]. Hydrocarbon ionomers prevalently require high-boiling solvents, which even in minute quantities strongly affect electrode morphology and reproducibility [3], but high ion-exchange capacity materials such as Pemion® provide solubility in desired low-boiling, green solvents. Hydrocarbon electrodes with high ion-exchange capacities must balance conductivity and swelling behaviour with the concomitant reduction in mechanical properties as a function of hydration. While a challenge to decal-tranfer, high Tg/Tα ionomers enable the rational, reproducible structuring of layers within electrodes to address these challenges [4]. Specific to fuel cells, recent in-situ results from sPP suggest the ‘agglomerate model’ for triple-phase boundary may be effected with by a combination of polymer properties and electrode design & deposition. Mechanically sound and electrochemically efficient catalyst layers based on the hydrocarbon ionomer properties will be discussed, with evaluation of ion-exchange capacities, molecular volumes, and swelling properties in addition to interactions with the supported electrocatalyst and porous transport layers and gas-diffusion layers. Alkaline anion-exchange membrane water electrolyzers are also a critical technology for the cost reduction of this green hydrogen, as has been suggested by the European Union’s Clean Hydrogen Joint Undertaking multi-annual work plan cost targets for this technology representing a >35% stack cost reduction at volume. This target is substantiated by the elimination of iridium, titanium, and precious metals-coated components c.f. proton-exchange membrane water electrolysis. Compared to alkaline systems, these can achieve markedly smaller stack sizes and use long-lived nickel coatings for pressurized operation. The presence of a membrane allows for the development of full-area electrodes based on porous transport layers (PTLs) rather than mesh electrodes. The requirements for ionomer operating in electrolyte have only recently been due to the development of commercial caustic-stable ionomers such as Aemion® [5], and in particular to the anode suggest balancing electrode cohesion and free volume. Recent guidance in system design suggests a larger role of cathode design in safe and effective operation than previously thought [6]. A comparison of strategies for PTL-based electrode design will be discussed across a range of ionomer properties, catalyst ink processing, and electrode deposition strategies, with comparison to ionomer-free designs. [1] M. Adamski, N. Peressin, S. Holdcroft, “On the evolution of sulfonated polyphenylenes as proton exchange membranes for fuel cells,” Mater. Adv., 2, 4966-5005 (2021). [2] S.H. Mirfarsi, A. Kumar, J. Jeong, M. Adamski, S. McDermid, B. Britton, E. Kjeang, “High-temperature stability of hydrocarbon-based Pemion® proton exchange membranes: A thermo-mechanical stability study,” Int. J. Hydrogen Energy, 50 B, 1507-1522 (2024). [3] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.F. Lee, W.Y. Huang, S. Holdcroft, “Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers,” J. Electrochem. Soc., 162, F513ff. (2015). [4] H. Nguyen, D. Sultanova, P.A. Heizmann, S. Vierrath, M. Breitwieser, “Improving the efficiency of fully hydrocarbonbased proton-exchange membrane fuel cells by ionomer content gradients in cathode catalyst layers,” Mater. Adv., 3, 8460ff (2022). [5] M. Moreno-González, P. Mardle, S. Zhu, B. Gholamkhass, S. Jones, N. Chen, B. Britton, S. Holdcroft, “One year operation of an anion exchange membrane water electrolyzer utilizing Aemion+® membrane: Minimal degradation, low H2 crossover and high efficiency”, J. Power Sources Adv., 19, 100109 (2023). [6] A. Klinger, O. Strobl, H. Michaels, M. Kress, N. Martic, A. Maltenberger, B. Britton, A. Belletti, R. Eichel, G. Schmid, “Transport of Hydrogen Through Anion Exchange Membranes in Water Electrolysis,” Adv. Mater. Interfaces, In press (2024).
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3242
Synergistic Pairing of Intermittent Renewables with Dynamic Aemion®-Based Alkaline Anion-Exchange Membrane Electrolysis
The rate-limiting factors of intermittent renewable energy deployment are grid interconnection amounts and timelines, and the storage of this energy. Hydrogen offers a solution to both issues, to the former offering the ability to produce a valuable and presently subsidized resource with direct connection before the interconnect to utilize overcapacity or even replacing an interconnect, and to the latter offering the unique ability to cost-effectively be stored geologically, transported between regions, and repurpose natural gas infrastructure. Global electrolysis capacity is projected to increase to >500 GW in 2030 and in excess of 2500 GW in 2050 (IEA Net Zero 2050). Buffering capacity with batteries holds some promise but the simplest and most preferred mode of operation would be for electrolysis to follow energy production directly. However, the two established electrolysis technologies suitable to full direct intermittent renewable pairing have limitations to their effectiveness. Proton-Exchange Membrane Water Electrolysis (PEMWE) are known to exhibits non-linear increases to iridium dissolution while operating greater than 1.6 V, in part due to corrosive environment and in part due to a concentrated volumetric current density resulting in a trade-off of performance and lifetime that limits the economic utility of highly dynamic operation. Alkaline water electrolyzers do not exhibit the same voltage limitations due to the alkaline environment and the whole-electrode activation of the KOH electrolyte, but the nature of the porous separator itself reduces the ability for fully dynamic operation, in particular managing hydrogen flux in ramp-down. Alkaline Anion-Exchange Membrane Water Electrolysis (alkaline AEMWE) offers the potential to combine the ability for highly dynamic operation of PEMWE with the larger potential window for electrode stability of AWE to synergistic effect. In essence, the full use of produced energy, lower capital cost of the technology, and ability to trade efficiency for markedly higher production rate results in a lower levelized cost of hydrogen than is achievable with the other technologies. Technology cost-models associated with both direct connection and ‘peaker’ operation will be presented, towards a fuller understanding of the most economically beneficial renewables pairings and operational modes in advance of the expected gigawatt scaling of this technology later this decade. Further, Alkaline AEMWE Aemion® AF2-HWK8-75-X has been demonstrated in excess of 1 year of operation with some intermittency resulting in no apparent membrane degradation, presenting a baseline for the break-in of commercial electrodes with standard conditions relevant to commercial stacks of 1 M KOH and 70 °C. In this presentation, 1.5 years of data with Aemion® AF3-HWK9-75-X, a next-generation material, and large-area (50 cm²) single-cell data with long-term operation with both NiFeOx and commercial electrodes employing representative modes of intermittency will be shown.
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3242
Synergistic Pairing of Intermittent Renewables with Dynamic Aemion®-Based Alkaline Anion-Exchange Membrane Electrolysis
The rate-limiting factors of intermittent renewable energy deployment are grid interconnection amounts and timelines, and the storage of this energy. Hydrogen offers a solution to both issues, to the former offering the ability to produce a valuable and presently subsidized resource with direct connection before the interconnect to utilize overcapacity or even replacing an interconnect, and to the latter offering the unique ability to cost-effectively be stored geologically, transported between regions, and repurpose natural gas infrastructure. Global electrolysis capacity is projected to increase to >500 GW in 2030 and in excess of 2500 GW in 2050 (IEA Net Zero 2050). Buffering capacity with batteries holds some promise but the simplest and most preferred mode of operation would be for electrolysis to follow energy production directly. However, the two established electrolysis technologies suitable to full direct intermittent renewable pairing have limitations to their effectiveness. Proton-Exchange Membrane Water Electrolysis (PEMWE) are known to exhibits non-linear increases to iridium dissolution while operating greater than 1.6 V, in part due to corrosive environment and in part due to a concentrated volumetric current density resulting in a trade-off of performance and lifetime that limits the economic utility of highly dynamic operation. Alkaline water electrolyzers do not exhibit the same voltage limitations due to the alkaline environment and the whole-electrode activation of the KOH electrolyte, but the nature of the porous separator itself reduces the ability for fully dynamic operation, in particular managing hydrogen flux in ramp-down. Alkaline Anion-Exchange Membrane Water Electrolysis (alkaline AEMWE) offers the potential to combine the ability for highly dynamic operation of PEMWE with the larger potential window for electrode stability of AWE to synergistic effect. In essence, the full use of produced energy, lower capital cost of the technology, and ability to trade efficiency for markedly higher production rate results in a lower levelized cost of hydrogen than is achievable with the other technologies. Technology cost-models associated with both direct connection and ‘peaker’ operation will be presented, towards a fuller understanding of the most economically beneficial renewables pairings and operational modes in advance of the expected gigawatt scaling of this technology later this decade. Further, Alkaline AEMWE Aemion® AF2-HWK8-75-X has been demonstrated in excess of 1 year of operation with some intermittency resulting in no apparent membrane degradation, presenting a baseline for the break-in of commercial electrodes with standard conditions relevant to commercial stacks of 1 M KOH and 70 °C. In this presentation, 1.5 years of data with Aemion® AF3-HWK9-75-X, a next-generation material, and large-area (50 cm²) single-cell data with long-term operation with both NiFeOx and commercial electrodes employing representative modes of intermittency will be shown.
- Open Access
- 1 February 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (2) , 024507
Doped Ceria Nanoparticles with Reduced Solubility and Improved Peroxide Decomposition Activity for PEM Fuel Cells
Ceria nanoparticles (NPs) have unique catalytic properties which make them suited to scavenge degrading radical species and their precursor peroxides during PEM fuel cell operation. However, in the acidic environment of the fuel cell, ceria dissolves and the resulting cations migrate within the MEA, causing performance and durability losses. In this work, ex situ testing was used to evaluate the peroxide decomposition, selectivity towards radical generation, and solubility of Gd, Pr, and Zr-doped ceria NPs over a range of crystallite sizes and dopant levels. These doped materials exhibit better peroxide scavenging activity and dissolution resistance than undoped ceria. In these materials, activity is largely governed by increased surface area due to high internal porosity at smaller crystallite sizes compared to undoped ceria. Of the compounds tested, ceria NPs doped with 15 at% Zr (10 nm) and 5 at% Pr (17 nm) exhibited greater dissolution resistance than undoped ceria. Stabilization of the former doped NPs is attributed to crystallite agglomeration, while the increased stability of the latter is proposed to be due to its internally-porous, mesoscale structure suggested by its sorption isotherm. Both materials are more dissolution-resistant and active peroxide decomposers compared to undoped ceria but exhibit increased byproduct radical generation.
- 1 February 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (2) , 024507
Open AccessDoped Ceria Nanoparticles with Reduced Solubility and Improved Peroxide Decomposition Activity for PEM Fuel Cells
Ceria nanoparticles (NPs) have unique catalytic properties which make them suited to scavenge degrading radical species and their precursor peroxides during PEM fuel cell operation. However, in the acidic environment of the fuel cell, ceria dissolves and the resulting cations migrate within the MEA, causing performance and durability losses. In this work, ex situ testing was used to evaluate the peroxide decomposition, selectivity towards radical generation, and solubility of Gd, Pr, and Zr-doped ceria NPs over a range of crystallite sizes and dopant levels. These doped materials exhibit better peroxide scavenging activity and dissolution resistance than undoped ceria. In these materials, activity is largely governed by increased surface area due to high internal porosity at smaller crystallite sizes compared to undoped ceria. Of the compounds tested, ceria NPs doped with 15 at% Zr (10 nm) and 5 at% Pr (17 nm) exhibited greater dissolution resistance than undoped ceria. Stabilization of the former doped NPs is attributed to crystallite agglomeration, while the increased stability of the latter is proposed to be due to its internally-porous, mesoscale structure suggested by its sorption isotherm. Both materials are more dissolution-resistant and active peroxide decomposers compared to undoped ceria but exhibit increased byproduct radical generation.
- 25 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 2 (8) , 3642-3656
Morphology and Transport of Multivalent Cation-Exchanged Ionomer Membranes Using Perfluorosulfonic Acid–CeZ+ as a Model System
- 25 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 2 (8) , 3642-3656
Morphology and Transport of Multivalent Cation-Exchanged Ionomer Membranes Using Perfluorosulfonic Acid–CeZ+ as a Model System
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (32) , 1403
Improved Water Management of Electrospun Nanofiber Membrane Electrode Assemblies at High Current Densities Measured in Operando Using Neutron Radiography
Electrospun PFSA-Pt/C nanofiber mats have demonstrated promise as electrodes for PEM fuel cells that are highly scalable and show improved performance and durability compared to traditional sprayed electrodes.1,2 As a result, it is of great interest to understand the underlying mechanisms responsible for these gains, so that these electrode structures may be optimized in order to further increase performance and durability. Neutron radiography was used to measure water formation through the cross-sections of sprayed gas diffusion electrodes (denoted GDE) and electrospun PFSA-Pt nanofiber electrodes (denoted NF) during operation. Both GDE and NF-containing MEAs were assembled in custom hardware specifically designed for use within the neutron beam and operated in a differential cell configuration at 80°C, with variable RH and current density. Initial polarization results (Figure 1a) demonstrated a lower OCV for the NF electrodes, which were attributed to shorting at the through-holes within the active area, specific to the custom-built imaging hardware. Regardless, the performance of NF electrodes is improved at high (2 A/cm2) current densities. Through-thickness water profiles at 0.2 V (Figure 1b) show that the water concentration is around 2x lower within the MEA and GDLs in the NF-containing MEA compared to the baseline GDE. The lower water contents suggests improved performance in the mass transport region, commensurate with the observed polarization curves. Hardware issues are currently being addressed, and further test results exploring effects of RH, current density, and NF composition, will be discussed. Acknowledgements This research is supported by the U.S. Department of Energy Fuel Cell Technologies Office, through the Fuel Cell Performance and Durability (FC-PAD) Consortium (Fuel Cells Program Manager: Dimitrios Papageorgopoulos and Technical Development Manager: Greg Kleen). References P. N. Pintauro, “Fuel Cell Membrane-Electrode-Assemblies with Ultra-Low Pt Nanofiber Electrodes,” Fuel Cell R&D Annual Merit Review Proceedings, 2018. Brodt, R. Wycisk, N. Dale, and P. Pintauro, “Power Output and Durability of Nanofiber Fuel Cell Cathodes with PVDF and Nafion/PVDF Binders”, J. Electrochem. Soc., 163 , F401-F410 (2016). Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (32) , 1403
Improved Water Management of Electrospun Nanofiber Membrane Electrode Assemblies at High Current Densities Measured in Operando Using Neutron Radiography
Electrospun PFSA-Pt/C nanofiber mats have demonstrated promise as electrodes for PEM fuel cells that are highly scalable and show improved performance and durability compared to traditional sprayed electrodes.1,2 As a result, it is of great interest to understand the underlying mechanisms responsible for these gains, so that these electrode structures may be optimized in order to further increase performance and durability. Neutron radiography was used to measure water formation through the cross-sections of sprayed gas diffusion electrodes (denoted GDE) and electrospun PFSA-Pt nanofiber electrodes (denoted NF) during operation. Both GDE and NF-containing MEAs were assembled in custom hardware specifically designed for use within the neutron beam and operated in a differential cell configuration at 80°C, with variable RH and current density. Initial polarization results (Figure 1a) demonstrated a lower OCV for the NF electrodes, which were attributed to shorting at the through-holes within the active area, specific to the custom-built imaging hardware. Regardless, the performance of NF electrodes is improved at high (2 A/cm2) current densities. Through-thickness water profiles at 0.2 V (Figure 1b) show that the water concentration is around 2x lower within the MEA and GDLs in the NF-containing MEA compared to the baseline GDE. The lower water contents suggests improved performance in the mass transport region, commensurate with the observed polarization curves. Hardware issues are currently being addressed, and further test results exploring effects of RH, current density, and NF composition, will be discussed. Acknowledgements This research is supported by the U.S. Department of Energy Fuel Cell Technologies Office, through the Fuel Cell Performance and Durability (FC-PAD) Consortium (Fuel Cells Program Manager: Dimitrios Papageorgopoulos and Technical Development Manager: Greg Kleen). References P. N. Pintauro, “Fuel Cell Membrane-Electrode-Assemblies with Ultra-Low Pt Nanofiber Electrodes,” Fuel Cell R&D Annual Merit Review Proceedings, 2018. Brodt, R. Wycisk, N. Dale, and P. Pintauro, “Power Output and Durability of Nanofiber Fuel Cell Cathodes with PVDF and Nafion/PVDF Binders”, J. Electrochem. Soc., 163 , F401-F410 (2016). Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1483
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
Fuel cells have potential for small power applications that require long periods, as much as several decades, of uninterrupted power. Small microwatt fuel cell stacks of varying membrane thickness were designed to allow for passive water management. The passive water management system was incorporated into the stack design by use of exposed Nafion membrane for lateral water transport. 1 An experimental and theoretical study of water management across the operating temperature range was conduction, including operando neutron imaging and the development of a multiphysics two-dimensional model. Stack testing was done between -55 °C to 85 °C using a baseline output current of 10 µA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s, or an average current of 16 µA. The stack spatial water concentration was monitored during various operating conditions through in situ neutron imaging. Figure 1 shows the main points of interest on the stack. Operating temperatures ranged from -55 °C to 85 °C to analyze water formation and subsequent water removal. Freezing and below-freezing temperatures were controlled by use of a liquid nitrogen cooled series of insulated boxes to prevent external water condensation during imaging. These measurements suggest successful water transport laterally, enabling operation from the sub-freezing environment to temperatures near the boiling point of water. Figure 2a depicts a constant operation for two hours at 16 µA and -20 ºC and the subsequent drying process in Figure 2b. Water production due to gas crossover in the stacks was quantified at below-freezing temperatures. At temperatures at and below -20 °C, the water production due to gas crossover was greater than the amount of water removal via the passive water management strategy with the current turned off, rather than a drying of the cell as expected. With the gases turned off as well, drying occurs. This indicates that the cell design must allow for water (ice) build-up during operation at these sub-freezing temperatures for successful operation. To avoid large amounts of hydrogen loss due to membrane crossover, we employ multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A two-dimensional multiphysics model for evaluation of water management was also developed to further describe and explore the passive water management system under different conditions. The fundamental model in its present form shows a similar shape but indicates faster water build-up than experimental data. This discrepancy is currently being resolved to allow for a more accurate representation. Acknowledgments: This work was supported by the U.S. Department of Energy. References: Chintam, M. S. Wilson, T. Rockward, S. Stariha, A. M. Baker, E. L. Brosha, D. S. Hussey, J. M. LaManna, D. L. Jacobson, J. Rau, R. L. Borup, ECS Transactions 86 (13), 233-244. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1483
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
Fuel cells have potential for small power applications that require long periods, as much as several decades, of uninterrupted power. Small microwatt fuel cell stacks of varying membrane thickness were designed to allow for passive water management. The passive water management system was incorporated into the stack design by use of exposed Nafion membrane for lateral water transport. 1 An experimental and theoretical study of water management across the operating temperature range was conduction, including operando neutron imaging and the development of a multiphysics two-dimensional model. Stack testing was done between -55 °C to 85 °C using a baseline output current of 10 µA and periodic pulses of 4.5 mA lasting 100 ms, every 100 s, or an average current of 16 µA. The stack spatial water concentration was monitored during various operating conditions through in situ neutron imaging. Figure 1 shows the main points of interest on the stack. Operating temperatures ranged from -55 °C to 85 °C to analyze water formation and subsequent water removal. Freezing and below-freezing temperatures were controlled by use of a liquid nitrogen cooled series of insulated boxes to prevent external water condensation during imaging. These measurements suggest successful water transport laterally, enabling operation from the sub-freezing environment to temperatures near the boiling point of water. Figure 2a depicts a constant operation for two hours at 16 µA and -20 ºC and the subsequent drying process in Figure 2b. Water production due to gas crossover in the stacks was quantified at below-freezing temperatures. At temperatures at and below -20 °C, the water production due to gas crossover was greater than the amount of water removal via the passive water management strategy with the current turned off, rather than a drying of the cell as expected. With the gases turned off as well, drying occurs. This indicates that the cell design must allow for water (ice) build-up during operation at these sub-freezing temperatures for successful operation. To avoid large amounts of hydrogen loss due to membrane crossover, we employ multiple layers of membrane to make a thick, mechanically reinforced and chemically stabilized membrane. A two-dimensional multiphysics model for evaluation of water management was also developed to further describe and explore the passive water management system under different conditions. The fundamental model in its present form shows a similar shape but indicates faster water build-up than experimental data. This discrepancy is currently being resolved to allow for a more accurate representation. Acknowledgments: This work was supported by the U.S. Department of Energy. References: Chintam, M. S. Wilson, T. Rockward, S. Stariha, A. M. Baker, E. L. Brosha, D. S. Hussey, J. M. LaManna, D. L. Jacobson, J. Rau, R. L. Borup, ECS Transactions 86 (13), 233-244. Figure 1
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 395-409
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
A small microwatt fuel cell stack with 8 cells was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Two stacks with active areas of 0.2 cm2, one with 200 µm of membrane and the other with 400 µm, were assembled and tested at varying temperatures and current conditions. Temperatures ranged –55 °C to 70 °C, with focus on the lower temperatures. Factors affecting water production and removal included temperature, gas crossover, and membrane thickness. Currents were applied from 16 µA to 10 mA after the cells were stabilized at temperature, followed by a period of drying to observe water transport to the external peripheries of the cell. A two-dimensional multiphysics model was developed to further explore the water management system in varying conditions.
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 395-409
Imaging and Modeling of Passive Water Management in a Miniature Fuel Cell
A small microwatt fuel cell stack with 8 cells was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Two stacks with active areas of 0.2 cm2, one with 200 µm of membrane and the other with 400 µm, were assembled and tested at varying temperatures and current conditions. Temperatures ranged –55 °C to 70 °C, with focus on the lower temperatures. Factors affecting water production and removal included temperature, gas crossover, and membrane thickness. Currents were applied from 16 µA to 10 mA after the cells were stabilized at temperature, followed by a period of drying to observe water transport to the external peripheries of the cell. A two-dimensional multiphysics model was developed to further explore the water management system in varying conditions.