Purnendu K. Dasgupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Purnendu K. Dasgupta has a total of 570 co-authors. Here are the top co-authors by number of shared publications:
Jianzhong Li
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79400-1061, and Department of Chemistry, The University of Texas at Arlington, Arlington, Texas 76019-0065
25 shared publications- Shin-Ichi Ohira
Department of Chemistry, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555, Japan
24 shared publications - Charles Phillip Shelor
Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, Texas 76019-0065, United States
17 shared publications Zhang Genfa
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061
13 shared publicationsKei Toda
Department of Chemistry, Kumamoto University , Kumamoto, 860-8555, Japan
12 shared publicationsJason V. Dyke
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061, USA
10 shared publications
Latest Publications
- Open Access
- 29 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (18) , 26993-27001
Continuous Hydrogen Sulfide Monitor Based on Positive Fluorescence Green Chemistry. Application to Geothermal Powerplant Environmental Impact Assessment
Renewable geothermal sources can be used for base-load power generation. Prior environmental impact assessment is needed, however, for H2S emitted from wells and cooling towers. Detailed spatiotemporal H2S concentration data need continuous monitoring by sensitive and fieldable H2S analyzers. Fluorescein mercuric acetate (FMA), a toxic organomercuric reagent, has been a staple for H2S measurement. We report a reagent containing copper 8-hydroxyquinoline-5-sulfonic acid (HQS) complex and Zn2+. As HS– from sample air bearing H2S reacts with such a reagent, thiophilic copper forms the hydrosulfide, and the released HQS forms a fluorescent zinc chelate. An automated fieldable H2S analyzer based on this green chemistry, comprising a disposable gas scrubber with controlled liquid flow at 50 μL/min and a UV-laser based fluorescence detector, is reported. The instrument operates on a (4 min sample, 6 min zero) reporting the difference signal via a Raspberry Pi controller to the cloud every 10 min with a working range of 0.3 ppb (limit of detection) to >100 ppb. During each cycle a total of 0.8 L air and 1 mL aqueous solution containing 5 μmol NaOH, 10 μmol 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, 40 nmol HQS, and 20 nmol each of Cu and Zn are consumed with a total chemical cost < USD $0.01. Performance characteristics and data from a geothermal field are reported. It provides far superior sensitivity and time resolution than conventional impinger absorption and colorimetry. It should find wide use in geothermal environmental assessment and for monitoring oil drilling and storage sites, paper-pulp and sewage treatment facilities, livestock management, etc.
- 29 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (18) , 26993-27001
Open AccessContinuous Hydrogen Sulfide Monitor Based on Positive Fluorescence Green Chemistry. Application to Geothermal Powerplant Environmental Impact Assessment
Renewable geothermal sources can be used for base-load power generation. Prior environmental impact assessment is needed, however, for H2S emitted from wells and cooling towers. Detailed spatiotemporal H2S concentration data need continuous monitoring by sensitive and fieldable H2S analyzers. Fluorescein mercuric acetate (FMA), a toxic organomercuric reagent, has been a staple for H2S measurement. We report a reagent containing copper 8-hydroxyquinoline-5-sulfonic acid (HQS) complex and Zn2+. As HS– from sample air bearing H2S reacts with such a reagent, thiophilic copper forms the hydrosulfide, and the released HQS forms a fluorescent zinc chelate. An automated fieldable H2S analyzer based on this green chemistry, comprising a disposable gas scrubber with controlled liquid flow at 50 μL/min and a UV-laser based fluorescence detector, is reported. The instrument operates on a (4 min sample, 6 min zero) reporting the difference signal via a Raspberry Pi controller to the cloud every 10 min with a working range of 0.3 ppb (limit of detection) to >100 ppb. During each cycle a total of 0.8 L air and 1 mL aqueous solution containing 5 μmol NaOH, 10 μmol 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, 40 nmol HQS, and 20 nmol each of Cu and Zn are consumed with a total chemical cost < USD $0.01. Performance characteristics and data from a geothermal field are reported. It provides far superior sensitivity and time resolution than conventional impinger absorption and colorimetry. It should find wide use in geothermal environmental assessment and for monitoring oil drilling and storage sites, paper-pulp and sewage treatment facilities, livestock management, etc.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Gaseous Nitrophenols sources and their contribution to HONO formation in an urban area
Nitrophenols (NPs) are compounds that comprise of hydroxyl (-OH) and nitro (-NO2) functional groups attached to at least one aromatic ring. NPs have significant impacts on human health, climate, and atmospheric chemistry. Despite numerous measurements of particulate NPs, little is still known about their gaseous atmospheric sources, chemistry, and fate. In this study, four gaseous NPs - 2,4-dinitrophenol (2,4-DNP), 4-nitrophenol (4-NP), 2-nitrophenol (2-NP), and 2-Methyl-4-nitrophenol (2-Me-4-NP) were continuously monitored during late spring in an urban area of Houston, Texas. Among the four NPs, 4-NP showed the highest abundance, followed by 2-Me-4-NP, 2-NP, and 2,4-DNP, with average concentrations of 0.47 ± 0.12 ppt, 0.41 ± 0.16 ppt, and 0.27 ± 0.09 ppt, respectively. Utilizing the Positive Matrix Factorization (PMF) model, seven sources: industrial NPs, secondary formation, phenol sources, acetonitrile source, natural gas/crude oil, traffic, and petrochemical industries/oil refineries were identified with NPs’ contributions to each factor of 83.3%, 6.6%, 3.3%, 3.2%, 2.0%, 0.9%, and 0.7%, respectively. A zero-dimensional Atmospheric Chemistry (AtChem2) box model was used to simulate the observed 2-NP and 2,4-DNP. The model revealed a 50.0% and 70.0% contribution from JNO2, aligning with measured 2-NP and 2,4-DNP, respectively. This resulted in a nitrous acid (HONO) production of 7.5 ± 2.5 ppt/h between 06:00 and 18:00 Central Standard Time (CST) from both NPs. An extrapolation including other known NPs suggests a maximum HONO formation of 13.8 ppt/h, still magnitudes lower than other known HONO formation processes. Nevertheless, it represents a non-negligible fraction and should be considered in areas with substantial primary NPs emissions, and the corresponding reaction mechanisms should be included in any such model. Combining PMF analysis with a photochemical box model provides identification of NPs sources and their atmospheric impact on HONO formation, offering policymakers insights for implementing effective control measures.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessGaseous Nitrophenols sources and their contribution to HONO formation in an urban area
Nitrophenols (NPs) are compounds that comprise of hydroxyl (-OH) and nitro (-NO2) functional groups attached to at least one aromatic ring. NPs have significant impacts on human health, climate, and atmospheric chemistry. Despite numerous measurements of particulate NPs, little is still known about their gaseous atmospheric sources, chemistry, and fate. In this study, four gaseous NPs - 2,4-dinitrophenol (2,4-DNP), 4-nitrophenol (4-NP), 2-nitrophenol (2-NP), and 2-Methyl-4-nitrophenol (2-Me-4-NP) were continuously monitored during late spring in an urban area of Houston, Texas. Among the four NPs, 4-NP showed the highest abundance, followed by 2-Me-4-NP, 2-NP, and 2,4-DNP, with average concentrations of 0.47 ± 0.12 ppt, 0.41 ± 0.16 ppt, and 0.27 ± 0.09 ppt, respectively. Utilizing the Positive Matrix Factorization (PMF) model, seven sources: industrial NPs, secondary formation, phenol sources, acetonitrile source, natural gas/crude oil, traffic, and petrochemical industries/oil refineries were identified with NPs’ contributions to each factor of 83.3%, 6.6%, 3.3%, 3.2%, 2.0%, 0.9%, and 0.7%, respectively. A zero-dimensional Atmospheric Chemistry (AtChem2) box model was used to simulate the observed 2-NP and 2,4-DNP. The model revealed a 50.0% and 70.0% contribution from JNO2, aligning with measured 2-NP and 2,4-DNP, respectively. This resulted in a nitrous acid (HONO) production of 7.5 ± 2.5 ppt/h between 06:00 and 18:00 Central Standard Time (CST) from both NPs. An extrapolation including other known NPs suggests a maximum HONO formation of 13.8 ppt/h, still magnitudes lower than other known HONO formation processes. Nevertheless, it represents a non-negligible fraction and should be considered in areas with substantial primary NPs emissions, and the corresponding reaction mechanisms should be included in any such model. Combining PMF analysis with a photochemical box model provides identification of NPs sources and their atmospheric impact on HONO formation, offering policymakers insights for implementing effective control measures.
- 9 October 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (19) , e202400455
Functionalization of High‐Density Polyethylene Capillaries for Open Tubular Ion Chromatography
Ion chromatography is the anion analysis benchmark. A miniature form, Open Tubular Ion Chromatography (OTIC), has attractive attributes for efficient ion separations. Here, we fabricate and characterize high‐density polyethylene (HDPE) open tubular anion exchange columns (OTCs). We attach positively charged latex particles onto negatively charged capillary surfaces. For efficient OTIC, column diameters need to be < ∼20 µm; functionalizing the bore is challenging. Methods to introduce acid groups to an HDPE capillary bore, e.g., sulfonation using chlorosulfonic or sulfuric acid solutions, with or without grafting of an aromatic ring through photo‐ or chemical grafting first, are explored. Following quaternary ammonium latex attachment, the ion exchange capacity and separating abilities of each OTC were measured as an index of OTC performance. Gradual loss of capacity was observed for many of these; high‐resolution mass spectrometry confirmed the leaching of detached oxidized/sulfonated oligomeric fragments and consequent poisoning of the latex sites. Ways to ameliorate this and/or to rejuvenate the columns are also described.
- 9 October 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (19) , e202400455
Functionalization of High‐Density Polyethylene Capillaries for Open Tubular Ion Chromatography
Ion chromatography is the anion analysis benchmark. A miniature form, Open Tubular Ion Chromatography (OTIC), has attractive attributes for efficient ion separations. Here, we fabricate and characterize high‐density polyethylene (HDPE) open tubular anion exchange columns (OTCs). We attach positively charged latex particles onto negatively charged capillary surfaces. For efficient OTIC, column diameters need to be < ∼20 µm; functionalizing the bore is challenging. Methods to introduce acid groups to an HDPE capillary bore, e.g., sulfonation using chlorosulfonic or sulfuric acid solutions, with or without grafting of an aromatic ring through photo‐ or chemical grafting first, are explored. Following quaternary ammonium latex attachment, the ion exchange capacity and separating abilities of each OTC were measured as an index of OTC performance. Gradual loss of capacity was observed for many of these; high‐resolution mass spectrometry confirmed the leaching of detached oxidized/sulfonated oligomeric fragments and consequent poisoning of the latex sites. Ways to ameliorate this and/or to rejuvenate the columns are also described.
- Open Access
- 23 March 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1305
Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review
- 23 March 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1305
Open AccessLiquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review
- Top Cited Papers
The Air Quality Index (AQI) in historical and analytical perspective a tutorial review
- 13 September 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1229, 340345
Geometric characterization of polymeric capillaries
- 13 September 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1229, 340345
Geometric characterization of polymeric capillaries
- 24 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (13) , 5442-5450
Automated Programmable Generation of Broad pH Range Volatile Ionic Eluents for Liquid Chromatography
Many of the universal detectors in liquid chromatography, including mass spectrometry, must completely volatilize the chromatographic eluent first before further processing and detection of the analytes. A basic requirement is that the eluent does not contain a nonvolatile dissolved component. However, separation of biomolecules must be conducted in mostly aqueous media of compatible pH and ionic strength if their biological activity must survive the separation process. Combinations of ammonia with acetic and formic acids are commonly used as eluent for this purpose but generally maximum concentrations that can be tolerated are relatively low. Further, buffering is good only over a limited pH range. We describe a system where the eluent is generated in an automated pressure-programmed manner from high-purity gaseous NH3 and CO2 through gas-permeable membrane devices. This can be aided by the prior presence of formic/acetic acids in the mobile phase to extend the attainable low pH limit. We outline the fundamental pH, ionic strength, and buffer intensity considerations and demonstrate the application of such eluents in the separation of amino acids, proteins, and monoclonal antibodies. We also demonstrate the use of dissolved CO2 as an ion-pairing agent in the separation of chiral amines.
- 24 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (13) , 5442-5450
Automated Programmable Generation of Broad pH Range Volatile Ionic Eluents for Liquid Chromatography
Many of the universal detectors in liquid chromatography, including mass spectrometry, must completely volatilize the chromatographic eluent first before further processing and detection of the analytes. A basic requirement is that the eluent does not contain a nonvolatile dissolved component. However, separation of biomolecules must be conducted in mostly aqueous media of compatible pH and ionic strength if their biological activity must survive the separation process. Combinations of ammonia with acetic and formic acids are commonly used as eluent for this purpose but generally maximum concentrations that can be tolerated are relatively low. Further, buffering is good only over a limited pH range. We describe a system where the eluent is generated in an automated pressure-programmed manner from high-purity gaseous NH3 and CO2 through gas-permeable membrane devices. This can be aided by the prior presence of formic/acetic acids in the mobile phase to extend the attainable low pH limit. We outline the fundamental pH, ionic strength, and buffer intensity considerations and demonstrate the application of such eluents in the separation of amino acids, proteins, and monoclonal antibodies. We also demonstrate the use of dissolved CO2 as an ion-pairing agent in the separation of chiral amines.