Revista Brasileira de Aplicações de Vácuo

Published by SBV Sociedade Brasileira de Vacuo

Abbrev: Rev. Bras. de Apl. de Vácuo
ISSN 0101-7659EISSN 1983-4047
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
241
2025 journal articles
9
Subject
  • Material Physics
  • Experimental Physics
  • Manufacturing
  • Nuclear Physics
  • Organic Semiconductors
  • Microelectromechanical Systems

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Material Physics
19
Manufacturing
18
Plasma Physics
11
Experimental Physics
9
Semiconductor Physics
9
Metallurgical Engineering
7
Organic Semiconductors
6
Optoelectronics & Optical Engineering
6
Electronic Packaging & Interconnection
6
Ceramic Materials
5

Top Countries

Publications in 2016-2026.

CountryPublications
Brazil
126
Indonesia
14
Turkey
1
Mexico
1
Tanzania
1
Italy
1
United States
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
0
Total Publications
4
Average Citations
0.00
Cited Publications
0
Cited Publications %
0%
Self Citations
0
Self Citations %
0%

Metrics
2023 Integrated Impact Indicators
I3
2
I3/N
0.17
h5_index
2
Monthly Citation Metric (MCM)
0

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
0
Max
0

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    SIMULAÇÃO DE FILMES FINOS APLICADOS AO REVESTIMENTO DE CANAIS DE RESFRIAMENTO POR CHUMBO-BISMUTO EUTÉTICO EM MICRORREATORES

    by Rodrigo de Souza, Francisco Tadeu Degasperi, Silvia Maria Farani Costa, Paulo Helio Kanayama

    This study aims to simulate the performance of thin films (Al2O3, SiC, TiN, and FeCrAl) applied as coatings on cooling channels in microreactors cooled by eutectic lead-bismuth alloy (LBE), evaluating their effectiveness in mitigating corrosion under realistic operating conditions. As methods, computational modeling in Python was employed, based on a phenomenological power-law corrosion kinetics that incorporates temperature (400–550 °C), dissolved oxygen concentration (5×10-⁷ wt%), fluid velocity (0.8 m/s), and material-specific properties, including activation energy, erosion-corrosion coefficient (kero,0), and velocity sensitivity exponent (γ). As main results, SiC demonstrated the best performance, maintaining a residual thickness of 0.39 μm after 10 years, above the critical thickness (0.2 μm); Al2O3 failed at 5.9 years; and TiN and FeCrAl exhibited premature failure (1.6 and 2.6 years, respectively). As main limitations, the study features a simplified channel geometry (straight and uniform), absence of irradiation effects, use of a steady-state thermal profile, and reliance on indirectly calibrated kinetic parameters due to scarce experimental data specifically for thin films in LBE under combined thermal and flow gradients.

  • Open Access

    MODIFICATION OF THE SURFACE OF TOOLOX44 STEEL BY ION IMPLANTATION BY PLASMA IMMERSION: MICROSTRUCTURAL EVOLUTION AND HARDNESS INCREASE

    by Gilmar de Souza Oliveira, Rafael Resende Lucas, André Ricardo Marcondes, Rogério Pinto Mota

    Surface engineering has played a central role in the development of materials by improving their application in severe conditions, such as metal forming and cutting operations, in which high contact stresses and cyclic loads accelerate the wear mechanisms to which they are subjected. In this context, the present work investigated the surface modification of Toolox 44 steel by the process of ion implantation by plasma immersion (3IP), with emphasis on its microstructure, crystalline phases and mechanical properties. Some samples were treated and characterized by Vickers microhardness tests, metallographic analysis and X-ray diffraction. The results showed that the 3IP treatment induces structural modifications more distributed at depth, characterized by a higher density of crystalline defects, microdeformations and compressive residual stresses, without the formation of a thick composite layer. This microstructural difference resulted in a considerable increase in the surface hardness of the samples (~889 HV), attributed to the synergistic action of the mechanisms of hardening by defects, fine precipitation and continuous structural gradient. In addition, the absence of abrupt interfaces suggests greater mechanical stability and lower susceptibility to failures such as cracks or delamination. From a technological point of view, compared to the most used surface treatments in this segment, this process has additional advantages, including lower processing temperature and reduced treatment time, expanding its potential for industrial applications. Thus, the results demonstrated that 3IP constitutes an advanced and efficient approach to surface engineering, offering an optimized combination of hardness and structural integrity, relevant for tools subjected to repetitive load operating conditions.

  • Open Access

    DESENVOLVIMENTO DE PROTÓTIPO VIRTUAL DE CÂMARA DE VÁCUO COM MACHINE LEARNING

    by Rodrigo de Souza, Francisco Tadeu Degasperi, Marcelo Duduchi Feitosa

    This work aimed to present the modeling, development, and validation process of a vacuum chamber virtual prototype capable of incorporating experimental uncertainties characteristic of real-world testing, with the purpose of accurately predicting the time required for the pumping process using machine learning. To train and validate the Random Forest model, a synthetic dataset containing 125,000 combinations of these variables was generated, with Gaussian noise added to the pumping time to simulate instrumental uncertainties. Performance was evaluated using mean absolute error and the coefficient of determination (R2), in addition to uncertainty estimation for the predictions and parametric optimization to achieve physically feasible target times. The results indicated high precision (R2 close to 1 and mean absolute error below 0.05 s), strong generalization capability, and fidelity in noise representation. The simulator proved promising to support the design of experiments. As limitations, it is acknowledged that noise was applied only to the model's output, without considering uncertainties in the input variables, and that the underlying physical model disregards phenomena such as leaks or non-ideal flow regimes, which may restrict its applicability in more complex experimental scenarios. It is worth noting that this work constitutes a methodological proof-of-concept study whose validation was performed in a controlled environment using synthetic data, establishing the foundation for future extensions involving experimental validation and the incorporation of more complex scenarios.

  • Open Access

    COMPARATIVE EFFECTS OF PLASMA-ACTIVATED WATER AND HYDROGEN PEROXIDE ON ESCHERICHIA COLI GROWTH KINETICS AND EPS CARBOHYDRATE CONTENT

    by Eduardo Ferreira Martins, Marina Clara Ribeiro dos Santos, Alvaro Busquet de Sant’ANna Junior, Jade Helena Campos Augustroze, Alice Loureiro Martins, Michael dos Santos Brito, Sonia Khouri Sibelino, Argemiro Soares da Silva Sobrinho, Rodrigo Sávio Pessoa

    Plasma-activated water (PAW) is a chemically complex antimicrobial liquid whose biological effects cannot be fully predicted from hydrogen peroxide (H2O2) concentration by itself. This study compared the effects of surfatron-generated PAW and free H2O2 on Escherichia coli ATCC 25922 using two exposure strategies: pulse exposure in phosphate-buffered saline (PBS) followed by sodium thiosulfate neutralization and growth in Mueller-Hinton broth (MHB), and direct oxidant addition to MHB before growth monitoring. Abiotic stability assays showed that MHB almost completely depleted detectable H2O2 after 24 h. Under pulse exposure, PAW at 50-mg/L H2O2-equivalent suppressed detectable OD600-based growth, whereas free H2O2 at the same concentration allowed recovery. Under direct addition, PAW allowed delayed growth while H2O2 caused severe growth delay at 50 mg/L. The saccharidic fraction of extracellular polymeric substances (EPS) differed among treatments: PAW-treated groups, especially direct addition at 50-mg/L H2O2-equivalent, showed the strongest carbohydrate accumulation in cell-associated and cuvette-adhered fractions. These results demonstrated that H2O2-equivalence alone is insufficient to predict PAW bioactivity and that exposure matrix strongly modulates bacterial growth recovery and EPS associated phenotypes.

  • Open Access

    THERMAL ANNEALING EFFECTS ON SURFACE MORPHOLOGY AND ELECTRON DYNAMICS IN PSIF-DBT:PCBM BLENDS

    by Bruno Gabriel Alves Leite Borges, Maiara de Jesus Bassi, Lucimara Stolz Roman, Maria Luiza Rocco Duarte Pereira

    We investigated the impact of thermal annealing on the electronic properties, order and transport characteristic of PSiF-DBT:PCBM bulk-heterojunction thin films using sulfur K-edge X-ray absorption spectroscopy (XAS) together with resonant Auger spectroscopy (RAS). PSiF-DBT:PCBM thin films were produced and thermally annealed at two distinct temperatures: 100 and 200°C. RAS experiments, combined with the core-hole clock methodology, were used to extract electron delocalization times by analyzing resonant and normal Auger decay channels following sulfur 1s excitation. The spectroscopic data yield element-specific information on the electronic states of PSiF-DBT and on interfacial charge-transfer processes in PSiF-DBT:PCBM blends as a function of annealing temperature, which was also investigated by atomic force microscopy. This methodology enables direct evaluation of thermal-treatment-induced changes in electronic coupling and charge-transport pathways in silicon-containing donor–acceptor organic semiconductor blends.

  • Open Access

    OPTICAL DETECTION OF A PRESSURE MICROSENSOR

    by Marcelo Bariatto Andrade Fontes, Eduardo Acedo Barbosa, Ruy Marcelo de Oliveira Pauletti, Francisco Tadeu Degasperi

    Microelectromechanical systems technology consists of manufacturing sensors and actuators on a micrometric scale, offering low response time, reproducibility, high sensitivity, and low manufacturing costs. Pressure microsensors have a wide range of applications in various areas, such as the automotive industry, production processes, medical equipment, and as an absolute pressure and vacuum sensor. The pressure microsensor developed is based on piezoresistors diffused on a silicon membrane, obtained by the anisotropic corrosion process. The standard response of the microsensor is electrical, obtained through a Wheatstone bridge circuit, in which the potential difference is a function of the resistance variation of the piezoresistors subjected to pressure. This work focused on the direct determination of the deflection of the membrane under pressure through optical measurements using a Michelson interferometer, thus obtaining a calibration curve (membrane deformation × pressure) providing a potential application as an absolute pressure and vacuum sensor. The experimental results were compared with theoretical and simulated values using the COMSOL Multiphysics simulator. The optical results indicated a linear relationship between membrane deformation and measured pressure, resulting in 3.61 μm/bar. Theoretical and simulated models suggest that the sensor's mounting is between free clamping and fully clamped.

  • Open Access

    ADJUSTING SAFIIRA BEAM LINE FOR THE CHARACTERIZATION OF A TRACKER GAS DETECTOR

    by João Vitor Schervenin, Nilberto Heder Medina, Vitor Ângelo Paulino de Aguiar, Nemitala Added, José Roberto Brandão de Oliveira, Marcilei Aparecida Guazzelli, Manuela Cavallaro, Francesco Cappuzzello, Alessandro Spatafora, Domenico Torresi, et al.

    This work presents the structural and instrumental modifications carried out on the Ion beam system for irradiation and applications (SAFIIRA) beamline at the Pelletron accelerator of the Universidade de São Paulo to enable the in-beam characterization of a gas tracker prototype developed for the Nuclear Matrix Elements for Neutrinoless Double Beta Decay (NUMEN) Project. The beamline was adapted to operate with high-purity isobutane at low pressures (10–30 mbar), requiring the implementation of a dedicated gas handling system, the installation of a thin silicon nitride (Si3N4) entrance window, a motorized target tower, and a chamber extension. The detector was tested with 16O, 12C, and 7Li ion beams under various tilt angles and beam rates. The system exhibited high stability during operation, with no signs of discharge or vacuum failure, confirming the suitability of the modified SAFIIRA setup for gas detector characterization under realistic experimental conditions.

  • Open Access

    VACUUM COMPONENTS OBTAINED BY SLA 3D PRINTING FOR HIGH-VACUUM APPLICATIONS

    by Henrique Chaves Gulino, Ricardo Cardoso Rangel, Francisco Tadeu Degasperi

    This work presents the development and evaluation of KF-25 standard flanges fabricated by 3D printing using stereolithography (SLA) for application in high vacuum systems. The aim is to provide a low-cost, fast, and geometrically flexible alternative to conventional metallic components for laboratory applications. The parts were modeled using Autodesk Inventor and printed with a photopolymer resin on an Anycubic Photon Mono 4K printer. One sample was coated with a 1 μm aluminum layer via thermal evaporation (PVD). Optical microscopy revealed continuous surfaces with no visible pores or air pockets, even at the micrometer scale. Pump-down tests were performed using the Edwards Auto 306 vacuum system, where the original aluminum flange was replaced with the printed samples. Both the untreated and the coated flanges reached final pressures on the order of 10-5 mbar. The aluminum-coated sample exhibited improved pressure stability over time, indicating reduced outgassing. The results demonstrate that SLA-printed flanges can be effectively used in real high vacuum conditions, offering significant advantages in terms of fabrication time, cost, and design flexibility. A discussion of the vacuum system and an estimated calculation of its degassing rate are performed. This study provides a promising pathway for future applications in more complex geometries and customized vacuum setups.

  • Open Access

    A GLOBAL SCIENTIFIC ENDEAVOR AND ITS BRAZILIAN CHAPTER: THE FIRST CUT AND POLISHED 2.5-CARAT CVD DIAMOND GROWN IN BRAZIL

    by José Vieira da Silva Neto, Javier Sierra Gómez, Márcio José Cuccolo Rosales, Evaldo José Corat, Vladimir Jesus Trava-Airoldi

    The synthesis of diamond films via chemical vapor deposition (CVD) represents one of the most transformative achievements in materials science over the past half-century. This technology transcended diamond from a gemological curiosity and an abrasive grit into a versatile, engineered material capable of meeting the extreme demands of modern technology. Its journey, from foundational thermodynamic paradox to commercial reality, is a story of global scientific collaboration and intense research. This review chronicles the comprehensive history of CVD diamond, describing the fundamental principles that enabled metastable diamond growth, the evolution of deposition techniques, the profound understanding of microstructure property relationships, and the subsequent expansion into a vast application landscape spanning electronics, tribology, optics, and biomedicine. In parallel with the global trajectory, this article integrates the specific history of the development of this technology in Brazil, as evidenced by the extensive national scientific output on the subject. By analyzing the broad collection of Brazilian publications from the 1990s to the 2020s, it is possible to trace the evolution of a research program that advanced in harmony with international progress. From early challenges in adherent diamond growth on metals to sophisticated innovations in nanocomposite films and foundational studies on single-crystal diamond, the Brazilian contribution, led by the National Institute for Space Research (INPE), has been essential to solving practical engineering challenges and expanding the frontiers of carbon-based thin films. This synthesis of the global and the local illustrates how a grand scientific challenge was addressed through a worldwide effort, with Brazil establishing a distinct and respected voice in the international diamond CVD community

  • Open Access

    DIAMOND-LIKE CARBON IN VENTRICULAR ASSIST DEVICES: HISTORY, TECHNIQUES, APPLICATIONS, AND HEMOCOMPATIBILITY

    by Rosa Corrêa Leoncio de Sá, Tarcísio Fernandes Leão, Evandro Drigo da Silva, Guilherme Barbosa Lopes Junior, Breno Nishida, José Ricardo Correa de Sousa Sobrinho, Marco Antonio Ramirez-Ramos, João Roberto Moro, Evaldo José Corat, Vladimir Jesus Trava-Airoldi, et al.

    Diamond-like carbon (DLC) coatings have become a prominent strategy to enhance the performance and hemocompatibility of ventricular assist devices (VADs). This review presents a comprehensive overview of the historical development of DLC coatings for VADs, the main DLC deposition techniques, types of blood pumps, substrate materials, and specific applications in VADs. DLC coatings, deposited via methods such as plasma-enhanced chemical vapor deposition, offer high hardness, chemical inertness, excellent wear resistance, and hemocompatibility, making them suitable for blood-contacting components in continuousflow centrifugal pumps and continuous axial-flow pumps. The ability to apply DLC to various substrates, including metals and polymers, further broadens its biomedical utility. Comparative analysis with other hemocompatible coatings, such as heparin, titanium nitride, and 2-methacryloyloxyethyl phosphorylcholine polymers, demonstrates that DLC provides a unique balance of durability and blood compatibility, although challenges remain regarding long-term adhesion and stability. Advances in doped and nanostructured DLC films continue to improve antimicrobial and antithrombotic properties. Overall, DLC coatings represent a significant advancement in the quest for safer, longer-lasting VADs, but further research is needed to optimize their clinical performance and address remaining limitations.