JURNAL SURYA ENERGY
Published by Universitas Muhammadiyah Palembang
- Scilit
- Power Systems & Electric Vehicles
- Energy Systems & Technologies
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 14
- Total Publications
- 22
- Average Citations
- 0.64
- Cited Publications
- 9
- Cited Publications %
- 40.9%
- Self Citations
- 0
- Self Citations %
- 0%
- Q1
- 0
- Med
- 1
- Q3
- 2
- 99%
- 5.6
- Max
- 6
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 28 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 81-87
Kuantifikasi Komplementaritas Operasional dan Kecukupan Suplai Sistem Hibrida Fotovoltaik-Pikohidro Off-Grid
Off-grid renewable generation systems require a supply that is not only energy-sufficient, but also stable to source variability. This study quantified the short-term operational complementarity between photovoltaic (PV) and picohydro and evaluated the adequacy of supply to load using hourly experimental data. The system consists of two PV modules of 50 Wp each and a picohydro DC generator with a nominal capacity of 200 W with a head of 4.53 m. Measurements were taken on 10–12 July 2025 at 09.00–15.00 (n=21), including irradiation, PV power and efficiency, water discharge, turbine power, generator power and efficiency, and load power. The temperature of the PV module was not analyzed because it was not measured during the experiment. Analyses included descriptive statistics, Shapiro-Wilk test, Pearson/Spearman correlation, linear regression, Friedman, Wilcoxon pairs, coefficient of variation (CV), trapezoidal energy integration, and load-supply adequacy ratio (LSAR). Results showed that irradiation was strongly related to PV power (r=0.998; R²=0.996; p<0.001), while water discharge was strongly related to generator power (r=0.927; R²=0.858; p<0.001). Hybridization lowered PV power CV by 33.54–53.12% and the decrease was significant (p=0.0024; rank-biserial=0.680). Hybrid energy reached 511.12; 445,42; and 436.84 Wh with an LSAR of 1.41; 1,22; and 1.21. Despite the surplus daytime energy, four of the 21 points showed generating power under load so storage remained necessary. The results showed picohydro served as an operational buffer that dampened PV fluctuations and improved supply adequacy. The findings were limited to daylight testing and did not yet represent 24-hour operation as the battery contribution was not analyzed separately.
- 28 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 81-87
Open AccessKuantifikasi Komplementaritas Operasional dan Kecukupan Suplai Sistem Hibrida Fotovoltaik-Pikohidro Off-Grid
Off-grid renewable generation systems require a supply that is not only energy-sufficient, but also stable to source variability. This study quantified the short-term operational complementarity between photovoltaic (PV) and picohydro and evaluated the adequacy of supply to load using hourly experimental data. The system consists of two PV modules of 50 Wp each and a picohydro DC generator with a nominal capacity of 200 W with a head of 4.53 m. Measurements were taken on 10–12 July 2025 at 09.00–15.00 (n=21), including irradiation, PV power and efficiency, water discharge, turbine power, generator power and efficiency, and load power. The temperature of the PV module was not analyzed because it was not measured during the experiment. Analyses included descriptive statistics, Shapiro-Wilk test, Pearson/Spearman correlation, linear regression, Friedman, Wilcoxon pairs, coefficient of variation (CV), trapezoidal energy integration, and load-supply adequacy ratio (LSAR). Results showed that irradiation was strongly related to PV power (r=0.998; R²=0.996; p<0.001), while water discharge was strongly related to generator power (r=0.927; R²=0.858; p<0.001). Hybridization lowered PV power CV by 33.54–53.12% and the decrease was significant (p=0.0024; rank-biserial=0.680). Hybrid energy reached 511.12; 445,42; and 436.84 Wh with an LSAR of 1.41; 1,22; and 1.21. Despite the surplus daytime energy, four of the 21 points showed generating power under load so storage remained necessary. The results showed picohydro served as an operational buffer that dampened PV fluctuations and improved supply adequacy. The findings were limited to daylight testing and did not yet represent 24-hour operation as the battery contribution was not analyzed separately.
- Open Access
- 27 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 72-80
Efisiensi Baterai LiFePO4 200Ah Pada Sistem PLTS 24 Volt Menggunakan Inverter Hibrida Off Grid 1,2 kW
The utilization of solar energy as a renewable energy source requires a reliable energy storage system because its availability depends on solar irradiation intensity. Lithium Iron Phosphate (LiFePO4) batteries are widely used as an energy storage medium due to their long cycle life, high safety, and stable voltage characteristics. This study aims to analyze the performance and efficiency of a 200 Ah LiFePO4 battery in a Solar Power Generation (PLTS) system equipped with 420 Wp solar panels, a 24 V system voltage, and a 1.2 kW hybrid off-grid inverter. The research was conducted experimentally through battery charging and discharging tests by observing voltage, current, power, energy, State of Charge (SoC), Depth of Discharge (DoD), and operating duration. The results showed that the charging process lasted for 3 hours, with the SoC increasing from 23% to 90%. The energy supplied to the system during the charging process was 1,376.18 Wh, while the energy stored in the battery was 841.30 Wh, resulting in a charging efficiency of 94%. During the discharging process, the test lasted for 4 hours with a battery efficiency of 75%, while the inverter output voltage remained relatively stable in the range of 217–218 V AC. These results indicate that the LiFePO4 battery demonstrated good performance and reliability as an energy storage medium for a 420 Wp, 24 V solar power system and has the potential to support more efficient and sustainable utilization of solar energy.
- 27 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 72-80
Open AccessEfisiensi Baterai LiFePO4 200Ah Pada Sistem PLTS 24 Volt Menggunakan Inverter Hibrida Off Grid 1,2 kW
The utilization of solar energy as a renewable energy source requires a reliable energy storage system because its availability depends on solar irradiation intensity. Lithium Iron Phosphate (LiFePO4) batteries are widely used as an energy storage medium due to their long cycle life, high safety, and stable voltage characteristics. This study aims to analyze the performance and efficiency of a 200 Ah LiFePO4 battery in a Solar Power Generation (PLTS) system equipped with 420 Wp solar panels, a 24 V system voltage, and a 1.2 kW hybrid off-grid inverter. The research was conducted experimentally through battery charging and discharging tests by observing voltage, current, power, energy, State of Charge (SoC), Depth of Discharge (DoD), and operating duration. The results showed that the charging process lasted for 3 hours, with the SoC increasing from 23% to 90%. The energy supplied to the system during the charging process was 1,376.18 Wh, while the energy stored in the battery was 841.30 Wh, resulting in a charging efficiency of 94%. During the discharging process, the test lasted for 4 hours with a battery efficiency of 75%, while the inverter output voltage remained relatively stable in the range of 217–218 V AC. These results indicate that the LiFePO4 battery demonstrated good performance and reliability as an energy storage medium for a 420 Wp, 24 V solar power system and has the potential to support more efficient and sustainable utilization of solar energy.
- Open Access
- 16 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 64-71
Ketidakseimbangan Beban Pada Gardu Distribusi PI0483 Penyulang Merapi di PLN ULP Indralaya
Load imbalance in a three-phase four-wire system can increase neutral current, conductor heating, and reduce utilization of distribution equipment. This study aims to: (1) determine the level of current imbalance and compare measured neutral current with the theoretical resultant; (2) calculate the apparent power associated with neutral current and its percentage relative to transformer capacity; and (3) determine load-balancing priorities based on electrical indicators. A quantitative descriptive case-study approach was applied using secondary data from the PI0483 Distribution Substation on the Merapi Feeder in Indralaya. The 100 kVA transformer supplies two circuits, with R-S-T phase currents of 26-15-16 A for Circuit I and 71-85-38 A for Circuit II. The results show imbalance levels of 24.56% and 27.49%, respectively. Measured neutral currents were 13 A and 47 A, while theoretical values were 10.54 A and 41.80 A. At an average phase-to-neutral voltage of 234 V, the apparent power associated with neutral current was 12.25 kVA based on calculated currents and 14.04 kVA based on measured currents, equivalent to 12.25%-14.04% of transformer capacity. Circuit II is prioritized for load balancing because of its higher imbalance, neutral current, phase-current range, and neutral-current apparent power. These findings highlight the importance of load redistribution and monitoring.
- 16 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 64-71
Open AccessKetidakseimbangan Beban Pada Gardu Distribusi PI0483 Penyulang Merapi di PLN ULP Indralaya
Load imbalance in a three-phase four-wire system can increase neutral current, conductor heating, and reduce utilization of distribution equipment. This study aims to: (1) determine the level of current imbalance and compare measured neutral current with the theoretical resultant; (2) calculate the apparent power associated with neutral current and its percentage relative to transformer capacity; and (3) determine load-balancing priorities based on electrical indicators. A quantitative descriptive case-study approach was applied using secondary data from the PI0483 Distribution Substation on the Merapi Feeder in Indralaya. The 100 kVA transformer supplies two circuits, with R-S-T phase currents of 26-15-16 A for Circuit I and 71-85-38 A for Circuit II. The results show imbalance levels of 24.56% and 27.49%, respectively. Measured neutral currents were 13 A and 47 A, while theoretical values were 10.54 A and 41.80 A. At an average phase-to-neutral voltage of 234 V, the apparent power associated with neutral current was 12.25 kVA based on calculated currents and 14.04 kVA based on measured currents, equivalent to 12.25%-14.04% of transformer capacity. Circuit II is prioritized for load balancing because of its higher imbalance, neutral current, phase-current range, and neutral-current apparent power. These findings highlight the importance of load redistribution and monitoring.
- Open Access
- 14 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 57-63
Analisis Kinerja Sensor JSN-SR04T pada Sistem Monitoring Ketinggian Air Sungai untuk Keselamatan Pelayaran Berbasis Internet of Things
Navigation safety in inland waterway and ferry transportation is strongly influenced by environmental conditions, particularly fluctuations in river water levels. Real-time water-level information is essential for supporting decision-making in determining safe, comfortable, and efficient navigation routes while optimizing fuel consumption and maintaining schedule reliability. This study aims to evaluate the performance of the JSN-SR04T ultrasonic sensor integrated into an Internet of Things (IoT)-based water-level monitoring system to support navigation safety. The proposed system employs an ESP32 microcontroller as the central data-processing unit and wireless communication interface through a Wi-Fi network. The JSN-SR04T sensor measures variations in river water levels in real time, while the measurement results are transmitted and displayed on a mobile device, enabling users to monitor water-level conditions remotely. The research methodology comprised system design, hardware and software implementation, and sensor performance evaluation. Sensor accuracy was assessed by comparing the ultrasonic sensor measurements with reference measurements obtained manually using a measuring ruler. Ten measurement trials were conducted at different water-level conditions. The results demonstrate that the developed system can continuously monitor water levels in real time with stable performance. The JSN-SR04T sensor achieved an average measurement accuracy of 98.67%, with a measurement error of less than 1.5%. These findings indicate that the proposed IoT-based monitoring system provides reliable real-time water-level information and has strong potential as a decision-support tool for inland navigation safety, route optimization, fuel-efficiency considerations, and mitigation of accident risks associated with changing river conditions.
- 14 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 57-63
Open AccessAnalisis Kinerja Sensor JSN-SR04T pada Sistem Monitoring Ketinggian Air Sungai untuk Keselamatan Pelayaran Berbasis Internet of Things
Navigation safety in inland waterway and ferry transportation is strongly influenced by environmental conditions, particularly fluctuations in river water levels. Real-time water-level information is essential for supporting decision-making in determining safe, comfortable, and efficient navigation routes while optimizing fuel consumption and maintaining schedule reliability. This study aims to evaluate the performance of the JSN-SR04T ultrasonic sensor integrated into an Internet of Things (IoT)-based water-level monitoring system to support navigation safety. The proposed system employs an ESP32 microcontroller as the central data-processing unit and wireless communication interface through a Wi-Fi network. The JSN-SR04T sensor measures variations in river water levels in real time, while the measurement results are transmitted and displayed on a mobile device, enabling users to monitor water-level conditions remotely. The research methodology comprised system design, hardware and software implementation, and sensor performance evaluation. Sensor accuracy was assessed by comparing the ultrasonic sensor measurements with reference measurements obtained manually using a measuring ruler. Ten measurement trials were conducted at different water-level conditions. The results demonstrate that the developed system can continuously monitor water levels in real time with stable performance. The JSN-SR04T sensor achieved an average measurement accuracy of 98.67%, with a measurement error of less than 1.5%. These findings indicate that the proposed IoT-based monitoring system provides reliable real-time water-level information and has strong potential as a decision-support tool for inland navigation safety, route optimization, fuel-efficiency considerations, and mitigation of accident risks associated with changing river conditions.
- Open Access
- 9 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 48-56
Studi Evaluasi Rewinding Motor Induksi Tiga Fasa 1,5 kW 3000 rpm dengan Parameter Tahanan Isolasi dan Arus Tanpa Beban
Three-phase induction motors are widely used as electric drives in industrial sectors; therefore, their reliability and operational condition must be continuously maintained. One common repair method applied to induction motors experiencing winding damage is the rewinding process. This study presents an evaluation of the rewinding results of a three-phase induction motor rated at 1.5 kW with a nominal speed of 3000 rpm, conducted at the Electrical and Instrumentation Workshop Unit of PT. Semen Padang. The objective of this research is to assess the operational feasibility of the motor after rewinding by examining the conformity of electrical parameters, the quality of the insulation system, and the phase current balance. The research methodology includes collecting nameplate data as a reference, documenting stator windings, performing a visual evaluation of the stator condition, and conducting electrical tests comprising winding resistance measurement, insulation resistance (Rsi) testing, Polarization Index (PI) evaluation, and no-load current measurement. The test results indicate that the winding resistance values are balanced at 4.6 Ω for each phase, while the insulation resistance ranges from 1.80 to 3.31 GΩ with a Polarization Index value of 2.17. The no-load current test results show an average current of 1.29 A, corresponding to approximately 41% of the rated current specified on the nameplate, with a current unbalance of 2.3%. Based on these results, it can be concluded that the rewinding process was successfully performed and the induction motor meets the technical requirements and is suitable for re-operation.
- 9 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 48-56
Open AccessStudi Evaluasi Rewinding Motor Induksi Tiga Fasa 1,5 kW 3000 rpm dengan Parameter Tahanan Isolasi dan Arus Tanpa Beban
Three-phase induction motors are widely used as electric drives in industrial sectors; therefore, their reliability and operational condition must be continuously maintained. One common repair method applied to induction motors experiencing winding damage is the rewinding process. This study presents an evaluation of the rewinding results of a three-phase induction motor rated at 1.5 kW with a nominal speed of 3000 rpm, conducted at the Electrical and Instrumentation Workshop Unit of PT. Semen Padang. The objective of this research is to assess the operational feasibility of the motor after rewinding by examining the conformity of electrical parameters, the quality of the insulation system, and the phase current balance. The research methodology includes collecting nameplate data as a reference, documenting stator windings, performing a visual evaluation of the stator condition, and conducting electrical tests comprising winding resistance measurement, insulation resistance (Rsi) testing, Polarization Index (PI) evaluation, and no-load current measurement. The test results indicate that the winding resistance values are balanced at 4.6 Ω for each phase, while the insulation resistance ranges from 1.80 to 3.31 GΩ with a Polarization Index value of 2.17. The no-load current test results show an average current of 1.29 A, corresponding to approximately 41% of the rated current specified on the nameplate, with a current unbalance of 2.3%. Based on these results, it can be concluded that the rewinding process was successfully performed and the induction motor meets the technical requirements and is suitable for re-operation.
- Open Access
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 18-24
Analisis Potensi Energi Biogas dari Limbah Sapi untuk Mendorong Transisi Energi Berkelanjutan
The transition from fossil fuels to renewable energy is a strategic step in addressing the energy crisis and the impacts of climate change. This study aims to analyze the potential of cow dung waste as a source of biogas-based electricity at Duta Lembu Farm, South Sumatra. The research employed a quantitative approach through field observations, interviews, literature review, and theoretical calculations of biogas volume, electricity generation, greenhouse gas emission reduction, and economic benefits. The results show that 210 kg of cow dung per day can produce 6.3 m³ of biogas, equivalent to 6.77 kWh/day or 203.1 kWh/month. This energy is sufficient to supply electricity for approximately 13 households or power 90 LED lamps, while also reducing greenhouse gas emissions by 157.5 kg CO₂/day. Economically, the utilization of biogas can save electricity costs of about Rp293,276.4 per month with a payback period of around 20 months. Thus, biogas utilization from cow dung is proven to be technically, economically, and environmentally feasible as a sustainable renewable energy solution.
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 18-24
Open AccessAnalisis Potensi Energi Biogas dari Limbah Sapi untuk Mendorong Transisi Energi Berkelanjutan
The transition from fossil fuels to renewable energy is a strategic step in addressing the energy crisis and the impacts of climate change. This study aims to analyze the potential of cow dung waste as a source of biogas-based electricity at Duta Lembu Farm, South Sumatra. The research employed a quantitative approach through field observations, interviews, literature review, and theoretical calculations of biogas volume, electricity generation, greenhouse gas emission reduction, and economic benefits. The results show that 210 kg of cow dung per day can produce 6.3 m³ of biogas, equivalent to 6.77 kWh/day or 203.1 kWh/month. This energy is sufficient to supply electricity for approximately 13 households or power 90 LED lamps, while also reducing greenhouse gas emissions by 157.5 kg CO₂/day. Economically, the utilization of biogas can save electricity costs of about Rp293,276.4 per month with a payback period of around 20 months. Thus, biogas utilization from cow dung is proven to be technically, economically, and environmentally feasible as a sustainable renewable energy solution.
- Open Access
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 33-47
Analisis Pengaruh Kontaminasi Debu Vulkanik Gunung Marapi terhadap Tahanan Isolasi Isolator Porselin: Studi Kasus Gardu Induk Padang Luar
Porcelain insulators are essential components in electric power transmission and distribution systems, functioning to electrically isolate conductors while preventing leakage current. The performance of porcelain insulators can deteriorate due to environmental contamination, particularly volcanic ash in areas affected by the eruption of Mount Marapi. This study aims to analyze the effect of natural volcanic ash contamination on the insulation resistance of a 20 kV porcelain insulator under different moisture conditions. An experimental method was employed by measuring insulation resistance using an insulation tester with a 5 kV DC test voltage. The tests were conducted under four conditions: clean insulator, dry volcanic ash contamination, moist volcanic ash contamination (16 gr of volcanic ash with 5 mL of water), and wet volcanic ash contamination (16 gr of volcanic ash with 10 mL of water). Each condition was tested ten times, and the measurement results were analyzed using descriptive statistics, including the mean, standard deviation, and percentage reduction in insulation resistance. The results showed that the average insulation resistance decreased from 1010.6 MΩ under clean conditions to 885.7 MΩ under dry volcanic ash contamination, 567.6 MΩ under moist volcanic ash contamination, and 219.8 MΩ under wet volcanic ash contamination. Compared with the clean condition, the insulation resistance decreased by 12.36%, 43.83%, and 78.25%, respectively. The findings indicate a decreasing trend in insulation resistance as the moisture content of the volcanic ash increased. These results provide useful information for the inspection and maintenance of porcelain insulators in substations located in volcanic ash-prone areas.
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 33-47
Open AccessAnalisis Pengaruh Kontaminasi Debu Vulkanik Gunung Marapi terhadap Tahanan Isolasi Isolator Porselin: Studi Kasus Gardu Induk Padang Luar
Porcelain insulators are essential components in electric power transmission and distribution systems, functioning to electrically isolate conductors while preventing leakage current. The performance of porcelain insulators can deteriorate due to environmental contamination, particularly volcanic ash in areas affected by the eruption of Mount Marapi. This study aims to analyze the effect of natural volcanic ash contamination on the insulation resistance of a 20 kV porcelain insulator under different moisture conditions. An experimental method was employed by measuring insulation resistance using an insulation tester with a 5 kV DC test voltage. The tests were conducted under four conditions: clean insulator, dry volcanic ash contamination, moist volcanic ash contamination (16 gr of volcanic ash with 5 mL of water), and wet volcanic ash contamination (16 gr of volcanic ash with 10 mL of water). Each condition was tested ten times, and the measurement results were analyzed using descriptive statistics, including the mean, standard deviation, and percentage reduction in insulation resistance. The results showed that the average insulation resistance decreased from 1010.6 MΩ under clean conditions to 885.7 MΩ under dry volcanic ash contamination, 567.6 MΩ under moist volcanic ash contamination, and 219.8 MΩ under wet volcanic ash contamination. Compared with the clean condition, the insulation resistance decreased by 12.36%, 43.83%, and 78.25%, respectively. The findings indicate a decreasing trend in insulation resistance as the moisture content of the volcanic ash increased. These results provide useful information for the inspection and maintenance of porcelain insulators in substations located in volcanic ash-prone areas.
- Open Access
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 25-32
Analisis Cakupan dan Performansi NB-IoT 900 MHz dengan Skema Standalone di Yogyakarta
The rapid development of the Internet of Things (IoT) has increased the demand for communication technologies that can provide wide coverage, low power consumption, and efficient spectrum utilization. One of the technologies developed to meet these requirements is Narrowband Internet of Things (NB-IoT), which is specifically designed to support low-data-rate IoT services with massive device connectivity. This study aims to design and analyze the performance of an NB-IoT network operating at 900 MHz using a standalone deployment scheme in the Yogyakarta region. The research method is carried out through network planning simulations using a link budget approach to estimate cell coverage, combined with the Okumura-Hatta Urban propagation model, which is suitable for urban environments. Network performance evaluation is conducted by analyzing key parameters, including Reference Signal Received Power (RSRP), Signal to Interference plus Noise Ratio (SINR), and downlink throughput. The simulation results show that the average RSRP value is −108.52 dBm, indicating relatively wide signal coverage. In addition, the average SINR value of 10.33 dB demonstrates good signal quality in the presence of interference and noise. Meanwhile, the average downlink throughput of 89.27 kbps indicates that the network is capable of efficiently supporting low-data-rate transmissions. Based on these results, it can be concluded that the standalone NB-IoT network design at 900 MHz in the Yogyakarta region is feasible for implementation. The network provides wide coverage, adequate signal quality, and performance suitable for supporting low-data-rate IoT applications, such as smart metering.
- 8 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 25-32
Open AccessAnalisis Cakupan dan Performansi NB-IoT 900 MHz dengan Skema Standalone di Yogyakarta
The rapid development of the Internet of Things (IoT) has increased the demand for communication technologies that can provide wide coverage, low power consumption, and efficient spectrum utilization. One of the technologies developed to meet these requirements is Narrowband Internet of Things (NB-IoT), which is specifically designed to support low-data-rate IoT services with massive device connectivity. This study aims to design and analyze the performance of an NB-IoT network operating at 900 MHz using a standalone deployment scheme in the Yogyakarta region. The research method is carried out through network planning simulations using a link budget approach to estimate cell coverage, combined with the Okumura-Hatta Urban propagation model, which is suitable for urban environments. Network performance evaluation is conducted by analyzing key parameters, including Reference Signal Received Power (RSRP), Signal to Interference plus Noise Ratio (SINR), and downlink throughput. The simulation results show that the average RSRP value is −108.52 dBm, indicating relatively wide signal coverage. In addition, the average SINR value of 10.33 dB demonstrates good signal quality in the presence of interference and noise. Meanwhile, the average downlink throughput of 89.27 kbps indicates that the network is capable of efficiently supporting low-data-rate transmissions. Based on these results, it can be concluded that the standalone NB-IoT network design at 900 MHz in the Yogyakarta region is feasible for implementation. The network provides wide coverage, adequate signal quality, and performance suitable for supporting low-data-rate IoT applications, such as smart metering.
- Open Access
- 3 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 9-17
Desain dan Uji Coba Prototipe Pengaturan Kualitas Air Untuk Budidaya Anakan Ikan Koi
Water quality is a fundamental aspect in koi fish farming because this species is highly susceptible to changes in environmental conditions, such as pH, temperature, turbidity levels, and solute concentrations. The mismatch of these parameters can inhibit growth, decrease immunity, and even increase the risk of fish death. Based on these problems, this research aims to design and develop a prototype of a microcontroller-based automatic water quality control system so that the condition of the pond remains in the optimal range. The research method is carried out through the design of integrated hardware and software. The system utilizes a pH sensor to measure the degree of acidity, a turbidity sensor to determine the turbidity of the water, a Total Dissolved Solids (TDS) sensor to detect the content of solutes, and a float level switch to monitor the height of the water level. Data from all sensors is processed by NodeMCU ESP8266 and sent to a web-based monitoring platform for real-time monitoring. If the parameters exceed the specified limits, the system automatically activates the pump, aerator, or filtration unit. The test results showed that the prototype was able to read parameters with a fast response and an adequate level of accuracy. Thus, this system can be concluded to be effective as a technological solution in supporting more efficient, controlled, and sustainable koi fish farming.
- 3 September 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 9-17
Open AccessDesain dan Uji Coba Prototipe Pengaturan Kualitas Air Untuk Budidaya Anakan Ikan Koi
Water quality is a fundamental aspect in koi fish farming because this species is highly susceptible to changes in environmental conditions, such as pH, temperature, turbidity levels, and solute concentrations. The mismatch of these parameters can inhibit growth, decrease immunity, and even increase the risk of fish death. Based on these problems, this research aims to design and develop a prototype of a microcontroller-based automatic water quality control system so that the condition of the pond remains in the optimal range. The research method is carried out through the design of integrated hardware and software. The system utilizes a pH sensor to measure the degree of acidity, a turbidity sensor to determine the turbidity of the water, a Total Dissolved Solids (TDS) sensor to detect the content of solutes, and a float level switch to monitor the height of the water level. Data from all sensors is processed by NodeMCU ESP8266 and sent to a web-based monitoring platform for real-time monitoring. If the parameters exceed the specified limits, the system automatically activates the pump, aerator, or filtration unit. The test results showed that the prototype was able to read parameters with a fast response and an adequate level of accuracy. Thus, this system can be concluded to be effective as a technological solution in supporting more efficient, controlled, and sustainable koi fish farming.
- Open Access
- 15 July 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 1-8
Analisis Efisiensi Energi Motor Induksi pada Horizontal Pumping System dengan Penggunaan Variable Speed Drive
Induction motors are the primary drivers in various industrial systems; however, their high energy consumption poses a challenge to efficiency improvement efforts. One technology used to optimize energy consumption is the Variable Speed Drive (VSD), which allows motor speed to be adjusted according to load requirements. This study aims to analyze the effect of using a VSD on the energy efficiency of a three-phase induction motor in a horizontal pumping system for produced water injection. Field tests were conducted on a 185 kW induction motor controlled by a VSD with frequency variations of 45–47.5 Hz. Parameters measured included voltage, current, power factor, fluid pressure, flow rate, and hydraulic output power. System efficiency was calculated as the ratio between electrical input power and hydraulic output power. The results show that the use of a VSD reduced starting power from 923.07 kW to 65.06 kW and increased efficiency from 57.26% to 59.34%. In conclusion, the VSD not only improves energy efficiency but also reduces mechanical load, stabilizes operation, and extends equipment lifespan. The implementation of this technology is recommended for industrial pump systems with variable torque loads to support energy conservation.
- 15 July 2026
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- p. 1-8
Open AccessAnalisis Efisiensi Energi Motor Induksi pada Horizontal Pumping System dengan Penggunaan Variable Speed Drive
Induction motors are the primary drivers in various industrial systems; however, their high energy consumption poses a challenge to efficiency improvement efforts. One technology used to optimize energy consumption is the Variable Speed Drive (VSD), which allows motor speed to be adjusted according to load requirements. This study aims to analyze the effect of using a VSD on the energy efficiency of a three-phase induction motor in a horizontal pumping system for produced water injection. Field tests were conducted on a 185 kW induction motor controlled by a VSD with frequency variations of 45–47.5 Hz. Parameters measured included voltage, current, power factor, fluid pressure, flow rate, and hydraulic output power. System efficiency was calculated as the ratio between electrical input power and hydraulic output power. The results show that the use of a VSD reduced starting power from 923.07 kW to 65.06 kW and increased efficiency from 57.26% to 59.34%. In conclusion, the VSD not only improves energy efficiency but also reduces mechanical load, stabilizes operation, and extends equipment lifespan. The implementation of this technology is recommended for industrial pump systems with variable torque loads to support energy conservation.