Diamond Light Source Proceedings
Published by Cambridge University Press (CUP)
- Scilit
- Total Citations
- 0
- Total Publications
- 0
- Average Citations
- 0.00
- Cited Publications
- 0
- Cited Publications %
- 0%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 0
- Monthly Citation Metric (MCM)
- 0
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 0
- Max
- 0
- Citing Source Titles
- Citing Publishers
Latest Publications
- 31 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Girder integration NSLS-II
National Synchrotron Light Source II (NSLS-II) will be a 3-GeV 792 m circumference third generation synchrotron radiation facility with ultra low emittance and extremely high brightness. There will be a total of 90 multipole storage ring girders supporting the vacuum chambers, multipole magnets and various pieces of ancillary equipment. A major effort is being made to meet the stringent assembly and alignment requirements for the girder assemblies using relatively few and removable positioning fixtures. Girder assembly and alignment will be accomplished in four phases. Each of these phases will be described along with the fixtures required.
- 31 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Girder integration NSLS-II
National Synchrotron Light Source II (NSLS-II) will be a 3-GeV 792 m circumference third generation synchrotron radiation facility with ultra low emittance and extremely high brightness. There will be a total of 90 multipole storage ring girders supporting the vacuum chambers, multipole magnets and various pieces of ancillary equipment. A major effort is being made to meet the stringent assembly and alignment requirements for the girder assemblies using relatively few and removable positioning fixtures. Girder assembly and alignment will be accomplished in four phases. Each of these phases will be described along with the fixtures required.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Status of Taiwan Photon Source front end in National Synchrotron Radiation Research Center
National Synchrotron Radiation Research Center (NSRRC) in Taiwan has initialized the construction of Taiwan Photon Source (TPS) synchrotron accelerator project. This 3 GeV, 500 mA beam current third-generation synchrotron accelerator will have a total of seven insertion device beam lines at day 1 after commissioning. That is, there will be one 2 × EPU48, five IU22 and one U5 undulator beamline. Corresponding front end components such as fixed masks, photon beam position monitor, photon absorber, slits and heavy metal shutter have been designed; manufacturing of these subsystems are on the way. Several prototype assemblies are completed, tested and will be reported in this paper.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Status of Taiwan Photon Source front end in National Synchrotron Radiation Research Center
National Synchrotron Radiation Research Center (NSRRC) in Taiwan has initialized the construction of Taiwan Photon Source (TPS) synchrotron accelerator project. This 3 GeV, 500 mA beam current third-generation synchrotron accelerator will have a total of seven insertion device beam lines at day 1 after commissioning. That is, there will be one 2 × EPU48, five IU22 and one U5 undulator beamline. Corresponding front end components such as fixed masks, photon beam position monitor, photon absorber, slits and heavy metal shutter have been designed; manufacturing of these subsystems are on the way. Several prototype assemblies are completed, tested and will be reported in this paper.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Stability of mirror chambers and mechanics: an example of the improvement of vibrational behaviour
ALBA synchrotron light facility includes a 3 GeV low-emittance storage ring capable of running in the top-up mode which will feed a number of beamlines. Xaloc and CIRCE are among these beamlines. These beamlines are equipped with mirrors which need high stability. There are a lot of mirror chambers in the market and we decided to improve one of them rather than developing a new one. For this purpose, the ALBA team organized a collaboration with a supplier of beamline components. ALBA did the conceptual design of the improvements, the Finite Element Analysis (FEA) optimization and the metrology tests. The supplier provided a detailed design and the production. The improvement was implemented on several mirror chambers including actuators from two to five degrees of freedom. At the beginning of the project, the hypothesis was an excitation coming from the ground lower than 1 µm for frequencies below 45 Hz and negligible above it. The strategy[0] in terms of dynamical stability was not to amplify the ground excitation below 45 Hz or around 50 Hz. That is, to increase the frequency of the system resonances above 45 Hz (excluding the range of about 50 Hz). As a result, we obtained a high level of stability for such mirror systems and we almost met the target value for the first mode of vibration.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Stability of mirror chambers and mechanics: an example of the improvement of vibrational behaviour
ALBA synchrotron light facility includes a 3 GeV low-emittance storage ring capable of running in the top-up mode which will feed a number of beamlines. Xaloc and CIRCE are among these beamlines. These beamlines are equipped with mirrors which need high stability. There are a lot of mirror chambers in the market and we decided to improve one of them rather than developing a new one. For this purpose, the ALBA team organized a collaboration with a supplier of beamline components. ALBA did the conceptual design of the improvements, the Finite Element Analysis (FEA) optimization and the metrology tests. The supplier provided a detailed design and the production. The improvement was implemented on several mirror chambers including actuators from two to five degrees of freedom. At the beginning of the project, the hypothesis was an excitation coming from the ground lower than 1 µm for frequencies below 45 Hz and negligible above it. The strategy[0] in terms of dynamical stability was not to amplify the ground excitation below 45 Hz or around 50 Hz. That is, to increase the frequency of the system resonances above 45 Hz (excluding the range of about 50 Hz). As a result, we obtained a high level of stability for such mirror systems and we almost met the target value for the first mode of vibration.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical aspects of the ID26 emission spectrometer II: improving stability for a large instrument by the use of multiple air pad supports
An instrument for X-ray emission spectroscopy (XES) based on perfect crystal Bragg optics was recently commissioned at beam line ID26 of the ESRF (European Synchrotron Radiation Facility). The spectrometer is used to record high-energy resolution fluorescence-detected X-ray absorption spectra with sub-lifetime resolution and to perform resonant and non-resonant XES. The hard X-ray probe is material bulk sensitive and allows demanding sample environments (in situ chemistry, high pressure, etc.). Spectrometers for XES are being installed or designed at almost all upcoming synchrotron radiation sources worldwide. The particularity of the ID26 spectrometer is to accommodate five analyser crystals with exact Rowland tracking in the vertical plane and with crystals radii between 0.5 and 2 m.The main upgrade of the new version of this large instrument (3 tonnes, overall size 2.5 m and height 3 m) is to allow the change of the scattering angle over the range 0–180°. This involves rotating the entire spectrometer around a vertical axis that passes through the sample. In order to optimize the vibration stability of the spectrometer's structure, we chose to support the structure in multiple points and not only on three (kinematic mount) like it is specified to do with air pads. According to this choice, we have developed special foot holders for air pads.The calculations during the design phase have shown that we can obtain a first modal frequency of the spectrometer's structure at more than 30 Hz. To confirm our predictive calculations, we have performed some vibration measurements.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical aspects of the ID26 emission spectrometer II: improving stability for a large instrument by the use of multiple air pad supports
An instrument for X-ray emission spectroscopy (XES) based on perfect crystal Bragg optics was recently commissioned at beam line ID26 of the ESRF (European Synchrotron Radiation Facility). The spectrometer is used to record high-energy resolution fluorescence-detected X-ray absorption spectra with sub-lifetime resolution and to perform resonant and non-resonant XES. The hard X-ray probe is material bulk sensitive and allows demanding sample environments (in situ chemistry, high pressure, etc.). Spectrometers for XES are being installed or designed at almost all upcoming synchrotron radiation sources worldwide. The particularity of the ID26 spectrometer is to accommodate five analyser crystals with exact Rowland tracking in the vertical plane and with crystals radii between 0.5 and 2 m.The main upgrade of the new version of this large instrument (3 tonnes, overall size 2.5 m and height 3 m) is to allow the change of the scattering angle over the range 0–180°. This involves rotating the entire spectrometer around a vertical axis that passes through the sample. In order to optimize the vibration stability of the spectrometer's structure, we chose to support the structure in multiple points and not only on three (kinematic mount) like it is specified to do with air pads. According to this choice, we have developed special foot holders for air pads.The calculations during the design phase have shown that we can obtain a first modal frequency of the spectrometer's structure at more than 30 Hz. To confirm our predictive calculations, we have performed some vibration measurements.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Design concept for a modular in-vacuum Hall probe mapper for in-vacuum undulators and cryogenic permanent magnet undulators of varying magnetic length
Both in-vacuum undulators (IVUs) and cryogenic permanent magnet undulators (CPMUs), each important to third-generation light sources, are best characterized in their operating environment. To create a precision Hall probe map of an IVU/CPMU (IVU hereafter), an in-vacuum magnetic measurement (IVMM) system is proposed. Point-by-point measurement of field and trajectory error informs corrective tuning.A novel design concept for a universal IVMM System has been developed and explored. The IVMM seals to the rectangular Ultra High Vacuum (UHV) flange of the IVU and shares its common vacuum space. Moreover, a modular design permits a wide range of IVUs of varying magnetic length to be mapped with a single IVMM, and is thus cost effective when multiple IVUs of varying configurations are planned. Here we review aspects of the modular IVMM design concept.
- 27 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Design concept for a modular in-vacuum Hall probe mapper for in-vacuum undulators and cryogenic permanent magnet undulators of varying magnetic length
Both in-vacuum undulators (IVUs) and cryogenic permanent magnet undulators (CPMUs), each important to third-generation light sources, are best characterized in their operating environment. To create a precision Hall probe map of an IVU/CPMU (IVU hereafter), an in-vacuum magnetic measurement (IVMM) system is proposed. Point-by-point measurement of field and trajectory error informs corrective tuning.A novel design concept for a universal IVMM System has been developed and explored. The IVMM seals to the rectangular Ultra High Vacuum (UHV) flange of the IVU and shares its common vacuum space. Moreover, a modular design permits a wide range of IVUs of varying magnetic length to be mapped with a single IVMM, and is thus cost effective when multiple IVUs of varying configurations are planned. Here we review aspects of the modular IVMM design concept.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
A double crystal monochromator with self-compensation mechanism for ELETTRA XRD2 beamline
A prototype of a new double crystal monochromator (DCM) has been designed and developed for the second crystallography beamline (XRD2) at ELETTRA. The new device has to cover the 8–35 keV X-ray range. Since the corresponding diffraction angles are quite small, the choice has been to design a DCM with a fixed distance between the two crystals. As a consequence, the output beam has a small vertical displacement during the scan. This movement is compensated by means of an upstream mask, vertically moving and cutting the input beam at different heights. The movement of the mask is driven by a mechanism linked to the primary rotation of crystals (self-compensation), without any additional motor and following the displacement law required for compensation. The principle, the mechanism and the general mechanical concept of the device will be described in this paper.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
A double crystal monochromator with self-compensation mechanism for ELETTRA XRD2 beamline
A prototype of a new double crystal monochromator (DCM) has been designed and developed for the second crystallography beamline (XRD2) at ELETTRA. The new device has to cover the 8–35 keV X-ray range. Since the corresponding diffraction angles are quite small, the choice has been to design a DCM with a fixed distance between the two crystals. As a consequence, the output beam has a small vertical displacement during the scan. This movement is compensated by means of an upstream mask, vertically moving and cutting the input beam at different heights. The movement of the mask is driven by a mechanism linked to the primary rotation of crystals (self-compensation), without any additional motor and following the displacement law required for compensation. The principle, the mechanism and the general mechanical concept of the device will be described in this paper.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Personnel safety system design for the photon beamlines at the Diamond Light Source
Diamond Light Source (DLS) is undertaking a programme of developing additional photon beamlines to be added to the existing facility. Operating in the UK, DLS is subject to the Ionizing Radiation Regulations, (IRR99) and having been elected to follow the path of generic prior authorization, DLS is obliged to implement a personnel safety system that conforms to the Approved Code of Practice. In addition, DLS has strived to apply EN61508 to the management and design of the system. This presentation will explain the constraints, design elements and the process that we have undertaken to implement each new safety system and its incorporation into the existing system.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Personnel safety system design for the photon beamlines at the Diamond Light Source
Diamond Light Source (DLS) is undertaking a programme of developing additional photon beamlines to be added to the existing facility. Operating in the UK, DLS is subject to the Ionizing Radiation Regulations, (IRR99) and having been elected to follow the path of generic prior authorization, DLS is obliged to implement a personnel safety system that conforms to the Approved Code of Practice. In addition, DLS has strived to apply EN61508 to the management and design of the system. This presentation will explain the constraints, design elements and the process that we have undertaken to implement each new safety system and its incorporation into the existing system.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical systems for a synchrotron X-ray-enhanced scanning tunnelling microscope
Synchrotron X-ray-enhanced scanning tunnelling microscopy (SXSTM) is a novel technique by which materials can be studied with elemental-sensitive and nanometre-spatial resolution. This poster covers the mechanical engineering design for the prototype SXSTM instrument. System performance and sample handling requirements along with the desire to use existing components constrained the design. The SXSTM needs to be mechanically and acoustically isolated from the environment. In addition, all sample preparations are done in situ, and thus, the sample and SXSTM tips need to be prepared and moved inside the vacuum chamber with a wobble stick. The final design incorporates an Advanced Photon Source-designed vacuum chamber, existing components and commercial parts to provide the user with a robust prototype system to demonstrate the impact of this new technique.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical systems for a synchrotron X-ray-enhanced scanning tunnelling microscope
Synchrotron X-ray-enhanced scanning tunnelling microscopy (SXSTM) is a novel technique by which materials can be studied with elemental-sensitive and nanometre-spatial resolution. This poster covers the mechanical engineering design for the prototype SXSTM instrument. System performance and sample handling requirements along with the desire to use existing components constrained the design. The SXSTM needs to be mechanically and acoustically isolated from the environment. In addition, all sample preparations are done in situ, and thus, the sample and SXSTM tips need to be prepared and moved inside the vacuum chamber with a wobble stick. The final design incorporates an Advanced Photon Source-designed vacuum chamber, existing components and commercial parts to provide the user with a robust prototype system to demonstrate the impact of this new technique.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical design and analysis of in-vacuum undulators at the Shanghai Synchrotron Radiation Facility
Two in-vacuum undulators (IVU25) have been used since March 2009 at the Shanghai Synchrotron Radiation Facility. Another small-gap in-vacuum undulator with a smaller period length of 20 mm was completed in July 2010. The mechanical system of IVU25 consists of support frame, driving and guiding system, taper mechanism, compensation spring system, suspending rods assembly, etc. We have attempted to manufacture IVU25 with high mechanical stability, rigidity and reproducible gap motion. A mechanical design study of IVU25 is carried out which includes finite-element calculations on the mechanical deformation of the girder. Some modifications have been made to the design of IVU20.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical design and analysis of in-vacuum undulators at the Shanghai Synchrotron Radiation Facility
Two in-vacuum undulators (IVU25) have been used since March 2009 at the Shanghai Synchrotron Radiation Facility. Another small-gap in-vacuum undulator with a smaller period length of 20 mm was completed in July 2010. The mechanical system of IVU25 consists of support frame, driving and guiding system, taper mechanism, compensation spring system, suspending rods assembly, etc. We have attempted to manufacture IVU25 with high mechanical stability, rigidity and reproducible gap motion. A mechanical design study of IVU25 is carried out which includes finite-element calculations on the mechanical deformation of the girder. Some modifications have been made to the design of IVU20.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
FERMI@ELETTRA bunch compressor chicane mechanical design
The FERMI@ELETTRA Free-Electron-Laser (FEL) project at the ELETTRA Laboratory of Sincrotrone Trieste, currently under construction and commissioning, will comprise a linear accelerator and two FEL beamlines. Two identical magnetic chicanes for bunch length compression will be installed in the linear accelerator (LINAC) tunnel. The first bunch compressor, at 300 MeV, has been recently installed and commissioned while the production and installation plan of the second one (at 600 MeV) is being defined. The chicane mechanical design has been achieved in collaboration with the supplier, Rial Vacuum srl. In this paper, the chicane mechanical design and the movable vacuum chambers are presented.
- 26 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
FERMI@ELETTRA bunch compressor chicane mechanical design
The FERMI@ELETTRA Free-Electron-Laser (FEL) project at the ELETTRA Laboratory of Sincrotrone Trieste, currently under construction and commissioning, will comprise a linear accelerator and two FEL beamlines. Two identical magnetic chicanes for bunch length compression will be installed in the linear accelerator (LINAC) tunnel. The first bunch compressor, at 300 MeV, has been recently installed and commissioned while the production and installation plan of the second one (at 600 MeV) is being defined. The chicane mechanical design has been achieved in collaboration with the supplier, Rial Vacuum srl. In this paper, the chicane mechanical design and the movable vacuum chambers are presented.