International Journal of Orthopedics and Rehabilitation
Published by Savvy Science Publisher
- Scilit
- Musculoskeletal Disorders
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 1
- Total Publications
- 4
- Average Citations
- 0.25
- Cited Publications
- 1
- Cited Publications %
- 25%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 3
- Monthly Citation Metric (MCM)
- 0
- Q1
- 0
- Med
- 0.5
- Q3
- 2
- 99%
- 4.9
- Max
- 5
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 29 October 2024
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 10, 1-9
Determining the Accuracy of Two Pelvic Ring Classification Systems: AO Tile and Young Burgess- A Systematic Review
Pelvic ring fractures (PRF) are high energy fractures with an incidence of 20/100,000 among all fractures and significant associated morbidity and mortality. PRF are often classified using Young-Burgess classification, and Tile AO classification. This project aims to review the literature comparing the two classification systems for reliability, clinical implications and guide for treatment plan. Google Scholar search was performed with the following words: “Young”, “Burgess”, “Tile”, “presentation”, “treatment”, “pelvic ring” in the Title/ After review of 828 results, 11 articles are included in this systematic review. Reliability of the classification systems positively correlated with an increase in years of experience. When comparing the reliability, Young-Burgess is shown to have moderate-to-substantial level of agreement for classifying pelvic fractures when accounting for expertise level, while Tile showed substantial agreement between specialists only. Young-Burgess better predicted mortality as compared to Tile, while another study found no significant difference. Tile B and LC fractures are found to have higher frequency of hemodynamic instability and undergo laparotomies more frequently. When comparing treatment options, there is a moderate level of agreement for the treatment option solely based on images. However, the question of how the classifications guide treatment outcomes remains unanswered. After review of current literature, it appears that Young-Burgess classification has slightly higher reliability and better prediction for mortality than Tile. However, there is a need for further research on how the classification systems can determine the treatment and outcomes to improve morbidity and mortality.
- 29 October 2024
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 10, 1-9
Open AccessDetermining the Accuracy of Two Pelvic Ring Classification Systems: AO Tile and Young Burgess- A Systematic Review
Pelvic ring fractures (PRF) are high energy fractures with an incidence of 20/100,000 among all fractures and significant associated morbidity and mortality. PRF are often classified using Young-Burgess classification, and Tile AO classification. This project aims to review the literature comparing the two classification systems for reliability, clinical implications and guide for treatment plan. Google Scholar search was performed with the following words: “Young”, “Burgess”, “Tile”, “presentation”, “treatment”, “pelvic ring” in the Title/ After review of 828 results, 11 articles are included in this systematic review. Reliability of the classification systems positively correlated with an increase in years of experience. When comparing the reliability, Young-Burgess is shown to have moderate-to-substantial level of agreement for classifying pelvic fractures when accounting for expertise level, while Tile showed substantial agreement between specialists only. Young-Burgess better predicted mortality as compared to Tile, while another study found no significant difference. Tile B and LC fractures are found to have higher frequency of hemodynamic instability and undergo laparotomies more frequently. When comparing treatment options, there is a moderate level of agreement for the treatment option solely based on images. However, the question of how the classifications guide treatment outcomes remains unanswered. After review of current literature, it appears that Young-Burgess classification has slightly higher reliability and better prediction for mortality than Tile. However, there is a need for further research on how the classification systems can determine the treatment and outcomes to improve morbidity and mortality.
- Open Access
- 10 October 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 15-23
Non-Traumatic Bone Marrow Edema of the Knee: Diagnostic Accuracy of Dual-Energy Computed Tomography in Comparison to MRI
Purpose; To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) to identify non-traumatic bone marrow edema (BME) of the knee. Methods; This prospective study, approved by the institutional review board, comprised a cohort of 40 consecutive patients (comprising 23 males and 17 females, with a mean age of 52.3 years) who underwent examination using Dual-Energy Computed Tomography (DECT) with settings of 80 kV and a tin filter at 150 kV, in addition to Magnetic Resonance Imaging (MRI), all conducted within 5 days. Subsequently, DECT data underwent post-processing and were evaluated by two experienced radiologists, resulting in the visualization of Bone Marrow Edema (BME) on color-coded maps. To determine the diagnostic accuracy of DECT in detecting BME, receiver operator curves and the area under the curve (AUC) were computed, with MRI serving as the reference standard. Interobserver agreement was calculated with k-statistics. A p-value Results; At MRI, BME was identified in 30/40 patients, with 106/480 (22,1%) involved partitions. Sensitivity and specificity of Reader 1 were 67,9% (95% CI: 58,2 - 76,7) and 95,99% (95% CI: 93,5 - 97,7), respectively. Sensitivity and specificity of Reader 2 were 69,8% (95% CI: 60,1 - 78,3) and 95,99% (95% CI: 93,5 - 97,7), respectively. Similar diagnostic accuracy values were achieved by the 2 readers, with an AUC of 0.82 for R1 and 0.829 for R2 (p=.743). The inter-observer agreement was k=0.68. Conclusions; DECT is an accurate imaging technique for the evidence of non-traumatic BME of the knee when compared to MRI.
- 10 October 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 15-23
Open AccessNon-Traumatic Bone Marrow Edema of the Knee: Diagnostic Accuracy of Dual-Energy Computed Tomography in Comparison to MRI
Purpose; To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) to identify non-traumatic bone marrow edema (BME) of the knee. Methods; This prospective study, approved by the institutional review board, comprised a cohort of 40 consecutive patients (comprising 23 males and 17 females, with a mean age of 52.3 years) who underwent examination using Dual-Energy Computed Tomography (DECT) with settings of 80 kV and a tin filter at 150 kV, in addition to Magnetic Resonance Imaging (MRI), all conducted within 5 days. Subsequently, DECT data underwent post-processing and were evaluated by two experienced radiologists, resulting in the visualization of Bone Marrow Edema (BME) on color-coded maps. To determine the diagnostic accuracy of DECT in detecting BME, receiver operator curves and the area under the curve (AUC) were computed, with MRI serving as the reference standard. Interobserver agreement was calculated with k-statistics. A p-value Results; At MRI, BME was identified in 30/40 patients, with 106/480 (22,1%) involved partitions. Sensitivity and specificity of Reader 1 were 67,9% (95% CI: 58,2 - 76,7) and 95,99% (95% CI: 93,5 - 97,7), respectively. Sensitivity and specificity of Reader 2 were 69,8% (95% CI: 60,1 - 78,3) and 95,99% (95% CI: 93,5 - 97,7), respectively. Similar diagnostic accuracy values were achieved by the 2 readers, with an AUC of 0.82 for R1 and 0.829 for R2 (p=.743). The inter-observer agreement was k=0.68. Conclusions; DECT is an accurate imaging technique for the evidence of non-traumatic BME of the knee when compared to MRI.
- 14 January 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 8-14
Effects of Lower Limbs Stretching on the Neck Range of Motion: Preliminary Evidence for Myofascial Sequence?
In recent years, various studies have demonstrated that the fascia can transmit the mechanical tensions generated by muscle activity over a distance. However, it is not yet clear whether this transmission follows precise anatomical lines. The present study aims to understand if the exercises at a distance can influence the range of motion of the neck, and if the effects are different by performing the exercises in various directions. The study was attended by 30 healthy volunteers aged between 19 and 32 years. Anterior flexion of the neck was checked before the protocols and retested to compare the difference after stretching the hamstrings and adductors. All evaluations were performed by the same operator using an electronic goniometer. Cervical ROM increased during both procedures, but after the hamstrings stretch it increased significantly more than after the adductors stretch (6.22° versus 1.44°). This study highlighted how fascia can transmit forces at a distance, but only according to precise myofascial sequences. Consequently, it is important to know the fascial organization in order to properly train the fascial system.
- 14 January 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 8-14
Effects of Lower Limbs Stretching on the Neck Range of Motion: Preliminary Evidence for Myofascial Sequence?
In recent years, various studies have demonstrated that the fascia can transmit the mechanical tensions generated by muscle activity over a distance. However, it is not yet clear whether this transmission follows precise anatomical lines. The present study aims to understand if the exercises at a distance can influence the range of motion of the neck, and if the effects are different by performing the exercises in various directions. The study was attended by 30 healthy volunteers aged between 19 and 32 years. Anterior flexion of the neck was checked before the protocols and retested to compare the difference after stretching the hamstrings and adductors. All evaluations were performed by the same operator using an electronic goniometer. Cervical ROM increased during both procedures, but after the hamstrings stretch it increased significantly more than after the adductors stretch (6.22° versus 1.44°). This study highlighted how fascia can transmit forces at a distance, but only according to precise myofascial sequences. Consequently, it is important to know the fascial organization in order to properly train the fascial system.
- 9 January 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 1-7
Comparison of Spiral Versus Lateral Plate Fixations in Treatment of Multiple Humeral Fractures: A Finite Element Analysis
Open reduction internal fixation technique has been generally accepted for treatment of complex humeral fractures. Traditional proximal humeral locking plate design (PHILOS) have been reported in clinical or biomechanical researches, while presently the spiral plate design has been introduced improved biomechanical behavior over conventional designs. In order to objectively realize the multi-directional biomechanical performances and minimally invasive surgery for humeral plate designs, a current conceptual finite element analysis has been conducted with identical cross-sectional features for humeral plates. The conceptual lateral, and spiral humeral plate models were constructed for virtual reduction and fixation to the multiple fractures of the humerus. Mechanical load cases including axial compression, counterclockwise torsion and anterior bending have been applied for confirming the multi-directional structural stability and implant safety in biomechanical perspective. Results revealed that the lateral humeral plate model showed lower equivalent (von-Mises) stress under counterclockwise torsion, while the spiral humeral plate model performed greater rigidity and lower equivalent (von-Mises) stress under other loading cases. Four models represented similar structural stiffness under bending load. Under the different mechanical load cases, the spiral humeral plate model revealed comparable results with acceptable multi-directional biomechanical behavior. The concept of spiral humeral plate design is worth considering in practical application in clinics. Implant safety and stability should be further investigated by evidences in future mechanical tests and clinical observations.
- 9 January 2023
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 9, 1-7
Comparison of Spiral Versus Lateral Plate Fixations in Treatment of Multiple Humeral Fractures: A Finite Element Analysis
Open reduction internal fixation technique has been generally accepted for treatment of complex humeral fractures. Traditional proximal humeral locking plate design (PHILOS) have been reported in clinical or biomechanical researches, while presently the spiral plate design has been introduced improved biomechanical behavior over conventional designs. In order to objectively realize the multi-directional biomechanical performances and minimally invasive surgery for humeral plate designs, a current conceptual finite element analysis has been conducted with identical cross-sectional features for humeral plates. The conceptual lateral, and spiral humeral plate models were constructed for virtual reduction and fixation to the multiple fractures of the humerus. Mechanical load cases including axial compression, counterclockwise torsion and anterior bending have been applied for confirming the multi-directional structural stability and implant safety in biomechanical perspective. Results revealed that the lateral humeral plate model showed lower equivalent (von-Mises) stress under counterclockwise torsion, while the spiral humeral plate model performed greater rigidity and lower equivalent (von-Mises) stress under other loading cases. Four models represented similar structural stiffness under bending load. Under the different mechanical load cases, the spiral humeral plate model revealed comparable results with acceptable multi-directional biomechanical behavior. The concept of spiral humeral plate design is worth considering in practical application in clinics. Implant safety and stability should be further investigated by evidences in future mechanical tests and clinical observations.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 67-73
The Relationship between Low Back Pain and Sport Practice in Young People
The purpose of the present study is to analyse the incidence of back pain in young people aged 10–12, considering participation in sport, the type of sport practised, the frequency of practice and the possible differences between genders. The study covered 2,270 students (1,214 boys and 1,056 girls) aged 10–12 in Majorca. The sample was selected from different clusters (schools) by means of convenience sampling. The questionnaire and data collection method were validated beforehand through test-retest. The results obtained show that the incidence of back pain reaches 38.3% (34.5% for boys and 42.8% for girls). There were significant relationships between back pain and sport practice, a positive one in boys and a negative one in girls, which can be explained by the fact that the two groups practised different sports. The highest incidence of back pain was detected among children who practised volleyball, gymnastics and swimming for over 4 hours a week, as well as among those who practised rhythmic gymnastics. Based on the results obtained, the study suggests that back pain is a malaise affecting the young population, especially females, in a considerable way, and that the type of sport as well as the frequency of practice determined whether a given sport can be a risk factor associated with back pain.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 67-73
Open AccessThe Relationship between Low Back Pain and Sport Practice in Young People
The purpose of the present study is to analyse the incidence of back pain in young people aged 10–12, considering participation in sport, the type of sport practised, the frequency of practice and the possible differences between genders. The study covered 2,270 students (1,214 boys and 1,056 girls) aged 10–12 in Majorca. The sample was selected from different clusters (schools) by means of convenience sampling. The questionnaire and data collection method were validated beforehand through test-retest. The results obtained show that the incidence of back pain reaches 38.3% (34.5% for boys and 42.8% for girls). There were significant relationships between back pain and sport practice, a positive one in boys and a negative one in girls, which can be explained by the fact that the two groups practised different sports. The highest incidence of back pain was detected among children who practised volleyball, gymnastics and swimming for over 4 hours a week, as well as among those who practised rhythmic gymnastics. Based on the results obtained, the study suggests that back pain is a malaise affecting the young population, especially females, in a considerable way, and that the type of sport as well as the frequency of practice determined whether a given sport can be a risk factor associated with back pain.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (1) , 5-15
Polycaprolactone-Coated Alginate/b-Tricalcium Phosphate Beads to Locally Deliver Vancomycin: A Pilot Study
Orthopedic device-related infections (ODRI) are difficult to control and the management of ODRI most frequently includes surgery and long-term antimicrobial therapy. Local application of vancomycin through a biodegradable carrier like alginate would provide a valuable tool, although it is hard to control the drug-release for a prolonged period of time due to its permeability. Coating with hydrophobic polymer such as polycaprolactone (PCL) may sustain the vancomycin release. We fabricated four types of vancomycin containing alginate/b-TCP beads (uncoated, coated with 1.25 w/v%, 2.5 w/v%, and 5.0 w/v% PCL). Scanning electron microscope (SEM) revealed that b-TCP particles were uniformly distributed on the surface of the uncoated beads and the most homogenous coating layer was observed using 2.5 w/v% PCL. Vancomycin release and its bioactivity were measured at the designated time points (1, 4, 12, 24 hours, then every day until disintegration). Burst release occured on the first hour, day 1, 2 and 6 respectively. The beads without coating dissolved at day 3, and those with different coatings dissolved at day 5, 6, and 9. The minimum concentration of the vancomycin in the elution was approximately 5 mg/L, higher than the vancomycin’s minimum inhibitory concentrations (MICs) for Methicillin-resistant Staphylococcus aureus (MRSA). PCL-coated alginate/b-TCP beads loaded with vancomycin may provide a potential local drug delivery device for the adjuvant antimicrobial therapy of the ODRI.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (1) , 5-15
Open AccessPolycaprolactone-Coated Alginate/b-Tricalcium Phosphate Beads to Locally Deliver Vancomycin: A Pilot Study
Orthopedic device-related infections (ODRI) are difficult to control and the management of ODRI most frequently includes surgery and long-term antimicrobial therapy. Local application of vancomycin through a biodegradable carrier like alginate would provide a valuable tool, although it is hard to control the drug-release for a prolonged period of time due to its permeability. Coating with hydrophobic polymer such as polycaprolactone (PCL) may sustain the vancomycin release. We fabricated four types of vancomycin containing alginate/b-TCP beads (uncoated, coated with 1.25 w/v%, 2.5 w/v%, and 5.0 w/v% PCL). Scanning electron microscope (SEM) revealed that b-TCP particles were uniformly distributed on the surface of the uncoated beads and the most homogenous coating layer was observed using 2.5 w/v% PCL. Vancomycin release and its bioactivity were measured at the designated time points (1, 4, 12, 24 hours, then every day until disintegration). Burst release occured on the first hour, day 1, 2 and 6 respectively. The beads without coating dissolved at day 3, and those with different coatings dissolved at day 5, 6, and 9. The minimum concentration of the vancomycin in the elution was approximately 5 mg/L, higher than the vancomycin’s minimum inhibitory concentrations (MICs) for Methicillin-resistant Staphylococcus aureus (MRSA). PCL-coated alginate/b-TCP beads loaded with vancomycin may provide a potential local drug delivery device for the adjuvant antimicrobial therapy of the ODRI.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (1) , 25-29
Chronic Pain Due to Pelvis Fracture and Perceptive Rehabilitation
Recently, somatosensory rehabilitation is knowing a growing interest in chronic pain condition. In fact, new evidences have associated an impaired lumbopelvic control with a decreased tactile acuity, generating and sustaining chronic low back pain mechanisms. Consequently, an adequate tactile rehabilitation, entailing a discrimination training with a stimulation tasks, seems to be effective on pain, reducing lumbopelvic impairments. Also the use of perceptual surfaces can be effective on back pain, favouring a tactile and proprioceptive sensory stimulation on the trunk and improving the postural control through a body midline realignment. The aim of this manuscript was to describe the preliminary evidences on two cases of chronic pain due to pelvis fracture treated with the perceptive surfaces. Furthermore, we have tried to clarify the mechanisms involved in chronic back pain and the effect of a somatosensory rehabilitation. Finally, it was analyzed the role of craniocaudal body midline with the gravitational vertical axis in the setting of correct alignment for improving postural control in these conditions.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (1) , 25-29
Open AccessChronic Pain Due to Pelvis Fracture and Perceptive Rehabilitation
Recently, somatosensory rehabilitation is knowing a growing interest in chronic pain condition. In fact, new evidences have associated an impaired lumbopelvic control with a decreased tactile acuity, generating and sustaining chronic low back pain mechanisms. Consequently, an adequate tactile rehabilitation, entailing a discrimination training with a stimulation tasks, seems to be effective on pain, reducing lumbopelvic impairments. Also the use of perceptual surfaces can be effective on back pain, favouring a tactile and proprioceptive sensory stimulation on the trunk and improving the postural control through a body midline realignment. The aim of this manuscript was to describe the preliminary evidences on two cases of chronic pain due to pelvis fracture treated with the perceptive surfaces. Furthermore, we have tried to clarify the mechanisms involved in chronic back pain and the effect of a somatosensory rehabilitation. Finally, it was analyzed the role of craniocaudal body midline with the gravitational vertical axis in the setting of correct alignment for improving postural control in these conditions.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 79-83
The Analysis of Postural Stability and the Risk of Falls After the Ischemic Stroke of the Brain - the Preliminary Report
The aim of the work is the analysis of postural stability and the risk of falls at persons after ischemic stroke of brain in reference to persons with the disease of the intervertebral disc. Thirty persons were studied (15 - after ischemic stroke, 8 women and 7 men, and 15 - with disease of intervertebral disc in the lumbar section of the spine, 6 women and 9 men) in the sharp period of the disease. The investigation consisted in execution of tests on postural stability and the risk of falls with using of the dynamic platform (Biodeks SD) on the beginning and on the end three weeks lasting the therapy. Results of Postural Stability like the risk of falls while duration of the therapy, in both studied groups, were changed. Group of patients after the ischemic stroke of the brain showed higher values in the test of postural stability and the risk of fall than the patients with the degenerative changes lumbar section of the spine. Persons with the disorders of the central nervous arrangement manifest the larger risk of the fall than the orthopedic patients. The larger quantity of inclination noted down in the arrow and frontal plane during the test of postural stability at patients with neurological disorders.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 79-83
Open AccessThe Analysis of Postural Stability and the Risk of Falls After the Ischemic Stroke of the Brain - the Preliminary Report
The aim of the work is the analysis of postural stability and the risk of falls at persons after ischemic stroke of brain in reference to persons with the disease of the intervertebral disc. Thirty persons were studied (15 - after ischemic stroke, 8 women and 7 men, and 15 - with disease of intervertebral disc in the lumbar section of the spine, 6 women and 9 men) in the sharp period of the disease. The investigation consisted in execution of tests on postural stability and the risk of falls with using of the dynamic platform (Biodeks SD) on the beginning and on the end three weeks lasting the therapy. Results of Postural Stability like the risk of falls while duration of the therapy, in both studied groups, were changed. Group of patients after the ischemic stroke of the brain showed higher values in the test of postural stability and the risk of fall than the patients with the degenerative changes lumbar section of the spine. Persons with the disorders of the central nervous arrangement manifest the larger risk of the fall than the orthopedic patients. The larger quantity of inclination noted down in the arrow and frontal plane during the test of postural stability at patients with neurological disorders.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 39-43
High Tibial Osteotomy Using the ‘Tomofix™’ Plating System: Short Term Outcomes in Young Adults
Proximal tibial valgus osteotomy is one of the treatment options for painful medial compartment osteoarthritis and varus deformity of the knee. The aim of our study was to determine and quantify how much osteotomy altered symptoms from medial compartment gonoarthrosis. In addition we aimed to establish whether the Tomofix plating system would permit early weight bearing and achieve union without the use of bone grafts. We prospectively analysed our experience with medial opening wedge high tibial osteotomy using the Tomofix plate. Thirty-five knees were included in the study. The mean age was 47 years (36-59 years). Mean duration of follow-up was 23 months (7-48 Months). All patients underwent medial opening wedge high tibial osteotomy using the Tomofix plating system. Data was recorded using the Oxford Knee score, the Knee Injury Osteoarthritis Outcome score and through review of pre and postoperative x-rays. Good outcomes were seen with statistically significant improvement of both scores. There were two delayed unions, the remainder united without requirement for graft. There was improvement, in Oxford and Knee injury osteoarthritis scores. Correction of mal-alignment was seen in all cases. Early weight bearing was found to be permissible without risk of adverse event. The Tomofix plate provided immediate stability and satisfactory healing of the osteotomy site without the need for bone graft. Good functional results were seen.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 39-43
Open AccessHigh Tibial Osteotomy Using the ‘Tomofix™’ Plating System: Short Term Outcomes in Young Adults
Proximal tibial valgus osteotomy is one of the treatment options for painful medial compartment osteoarthritis and varus deformity of the knee. The aim of our study was to determine and quantify how much osteotomy altered symptoms from medial compartment gonoarthrosis. In addition we aimed to establish whether the Tomofix plating system would permit early weight bearing and achieve union without the use of bone grafts. We prospectively analysed our experience with medial opening wedge high tibial osteotomy using the Tomofix plate. Thirty-five knees were included in the study. The mean age was 47 years (36-59 years). Mean duration of follow-up was 23 months (7-48 Months). All patients underwent medial opening wedge high tibial osteotomy using the Tomofix plating system. Data was recorded using the Oxford Knee score, the Knee Injury Osteoarthritis Outcome score and through review of pre and postoperative x-rays. Good outcomes were seen with statistically significant improvement of both scores. There were two delayed unions, the remainder united without requirement for graft. There was improvement, in Oxford and Knee injury osteoarthritis scores. Correction of mal-alignment was seen in all cases. Early weight bearing was found to be permissible without risk of adverse event. The Tomofix plate provided immediate stability and satisfactory healing of the osteotomy site without the need for bone graft. Good functional results were seen.
- Open Access
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 44-48
The Effects of Transcutaneous Electrical Nerve Stimulation on Osteoarthritic Knees: A Literature Review
Osteoarthritis (OA) is reportedly the most common joint disease among older adults. This condition is a primary cause of pain and disability and results in more than 700,000 total knee replacements in the US each year. Transcutaneous electrical nerve stimulation (TENS) has long been a safe, non-invasive way to treat OA of the knees, however the overall benefit of TENS remains questionable. A review of literature on the effectiveness of TENS on OA of the knees indicates that benefits are typically seen in pain reduction and increased function. However, similar benefits are frequently seen with the use of sham-TENS introducing the possible influence of a placebo effect. For this reason the effectiveness of TENS remains inconclusive. The combination of TENS and acupuncture (electroacupuncture) is less studied, nevertheless available results indicate benefits in reducing pain and increasing function with statically significant higher benefits than sham-electroacupuncture.
- 25 May 2022
- Published by Savvy Science Publisher in International Journal of Orthopedics and Rehabilitation
- Vol. 1 (2) , 44-48
Open AccessThe Effects of Transcutaneous Electrical Nerve Stimulation on Osteoarthritic Knees: A Literature Review
Osteoarthritis (OA) is reportedly the most common joint disease among older adults. This condition is a primary cause of pain and disability and results in more than 700,000 total knee replacements in the US each year. Transcutaneous electrical nerve stimulation (TENS) has long been a safe, non-invasive way to treat OA of the knees, however the overall benefit of TENS remains questionable. A review of literature on the effectiveness of TENS on OA of the knees indicates that benefits are typically seen in pain reduction and increased function. However, similar benefits are frequently seen with the use of sham-TENS introducing the possible influence of a placebo effect. For this reason the effectiveness of TENS remains inconclusive. The combination of TENS and acupuncture (electroacupuncture) is less studied, nevertheless available results indicate benefits in reducing pain and increasing function with statically significant higher benefits than sham-electroacupuncture.