Medical Imaging and Radiotherapy journal

Published by Strokovno zdruzenje radioloskih inzenirjev Slovenije – ZDRI

Abbrev: Med. Imaging Radiother. J.
ISSN 2712-2492EISSN 2738-4012
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
20
2025 journal articles
0
Subject
  • Biomedical Physics
  • Lung Cancer

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Biomedical Physics
12
Brain Imaging
3
Lung Cancer
3
Musculoskeletal Disorders
2
Prostate Cancer
2
Oncology
2
Congenital Disorders
1
Dentistry & Oral Medicine
1
Respiratory Support
1
Neurodegenerative Disorders
1

Top Countries

Publications in 2016-2026.

CountryPublications
Slovenia
9
Bosnia and Herzegovina
1
Croatia
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
0
Total Publications
3
Average Citations
0.00
Cited Publications
0
Cited Publications %
0%
Self Citations
0
Self Citations %
0%

Metrics
h5_index
1
Monthly Citation Metric (MCM)
0

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
0
Max
0

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • RADIOGRAPHY CLINICAL EDUCATION AMIDST THE COVID-19 PANDEMIC: PERSPECTIVE OF RADIOGRAPHY STUDENTS INTERNATIONALLY

    by Michelle O’cOnnor, Switinder Singh Ghotra, Alja Čekada, Tim Dijkstra, Luca Ferrari, Sarah McGrath, Catarina Repryntseva, Annemieke van der Heij-Meijer, Michaela Davis

    Purpose: The COVID-19 pandemic has signifi cantly impacted clinical practice. This study explored the impact of the pandemic on diagnostic radiography clinical education from the perspective of radiography students internationally. Materials and methods: A qualitative approach was used to gain insight into students' experience of clinical placement during the pandemic. A total of sixteen radiography students from six countries were recruited from an international Radiography summer research school. Qualitative data was gathered via three semi-structured focus groups (5-6 students per focus group). Data was analysed using Braun and Clark’s phases of thematic analysis. Results: Five key themes emerged in relation to clinical education during the COVID-19 pandemic, (i) unequal student access to personal protective equipment (PPE) (ii) challenges in achieving clinical learning outcomes (iii) impact of online education on clinical readiness (iv) emotional impact, and (v) coping strategies. Students indicated that they were particularly afraid of transmitting COVID-19 to their family and friends. Some students reported that they felt under pressure to receive COVID-19 vaccinations prior to clinical practice. Others reported confusion with respect to infection control guidelines and application of PPE. Conclusion: Student radiographers identifi ed key challenges which require consideration by educators to ensure students are appropriately prepared for and supported on clinical placement during a pandemic. Implications for practice: • The COVID-19 pandemic has impacted clinical education internationally and this study identifi es the implications for radiography students in terms of clinical readiness and their clinical placement experience. • Simulation-based in-person learning in the X-ray lab and PPE training were perceived by students to be important factors impacting clinical readiness.

  • RADIOGRAPHERS AND EMPATHY - A LITERATURE REVIEW

    by Laura Cigut, Nastja Tanko, Tina Starc, Alenka Matjašič

    Purpose: The purpose of this paper was to introduce the concept of empathy in the radiographer profession. We explored why empathy is an important component of the radiographer, the positive impact of empathy on patients and radiographers, the negative impact of empathy on radiographers, how to introduce empathy into the workplace, and what infl uence the expression or non-expression of empathy has on radiographers. Materials and methods: We searched for the following keywords: empathy, emotional labour, radiological engineer, empathy, radiographer, radiologic technologist, burnout in radiography. Articles published from 1991 onwards were considered and only articles in Slovene and English with full text availability were included. Results: 13 articles were included in the analysis, which are summarised in a table. Empathy is a fundamental tool for building a therapeutic relationship between radiographers and patients and contributes to a better diagnostic quality of the examination. Empathy has a positive infl uence on therapeutic outcomes and on radiographers, as it can help to reduce stress and burnout in the workplace and improve the quality of life of professionals. However, constant exposure to stressful and emotionally diffi cult situations can have emotional and motivational consequences, such as empathic anxiety and personal distress. Understanding patients' emotions, opinions and experiences, helps radiographers to assess their needs and act accordingly. Conclusion: Empathy plays an important role in the work of radiographers as it contributes to a better relationship with the patient and helps to improve the diagnostic and therapeutic quality of the examination. Keywords: empathic care, burnout, empathic training, radiographers

  • MONITORING OF A SEVERE COVID-19 PATIENT WITH PNEUMOTHORAX COMPLICATIONS THROUGH RADIOLOGICAL AND LABORATORY DIAGNOSIS

    by Darko Tomić, Jasmina Marušić, Vesna Majher Tomić, Dragana Makotić, Ivana Stojak, Vedran Đido

    Introduction: Monitoring and treatment of severely ill patients with the coronavirus disease who are on mechanical ventilation due to the severity of the disease with the development of many complications remains a challenge. The increased incidence of pneumothorax in Covid-19 patients on mechanical ventilation may be due to a combination of infection-induced parenchymal injury and infl ammatory response with additional positive pressure ventilation. Materials and methods: In our study, we report a case of a severe Covid-19 patient with a pneumothorax complication through radiological and laboratory diagnostics. The performed radiogram of the lungs was taken each time in the AP projection in a semi-sitting position. A digital mobile X-ray device was used for imaging. All laboratory parameters that were monitored in the patient are performed in the panel of standard routine controls for patients with Covid-19. Results: The radiogram was better as the administration of therapy and chest drain were eff ective. Biochemical and hematological parameters are performed, which indicate a decrease in the number in blood count and biochemistry. The patient spent a total of 80 days in the hospital. Conclusion: Survival of a severe form of Covid-19 infection with the complication of pneumothorax is very rare, but still possible, as shown in our case. A chest radiograph with laboratory monitoring of the condition is of great importance in establishing the diagnosis of Covid-19 infection, and in the fi nal assessment of the patient's condition upon discharge from the hospital. Keywords: Covid-19, mechanical ventilation, pneumothorax, radiological diagnostics, laboratory diagnostics.

  • Open Access

    MRI SAFETY AND MANAGEMENT OF PATIENTS WITH CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES: LITERATURE REVIEW AND CASE PRESENTATION

    by Matic Godec, Jani Izlakar, Gašper PODOBNIK

    Introduction: MRI has long been contraindicated in patients with CIED devices due to the risk of adverse effects through electromagnetic interference. Recent developments in engineering have led to the introduction of the MRI conditional CIED devices that do not cause significant clinical harm to patients undergoing MRI, when specific imaging conditions are meet. Safe access to MRI has become a crucial need for patients with CIED devices. Aim: The purpose of this paper is to present an overview of managing patients with implanted CIED devices and to present a case report of a patient with CIED undergoing prostate MRI examination. Methods: This paper explores the MRI Safety and managing of patients with implanted CIED devices through an extensive literature review and case presentation. The literature search was conducted using medical scientific electronic databases such as PubMed, Cinahl, Wiley Online Library and ScienceDirect. We examined a patient with CIED device undergoing prostate MRI examination. Results and discussion: We performed the examination of the described patient with accordance to the guidelines presented in this paper. MR conditionality status was determined using device identification card and manufacturers technical manual. The MRI examination of the patient was completed without complications therefore; no adverse effects were reported. MRI images were without artefacts. Conclusion: Recent clinical studies and published guidelines suggest that MRI of the patients with either MRI conditional or MRI non conditional CIED device is relatively safe under specific conditions. Multidisciplinary pre-procedure planning, strict screening process, monitoring and device evaluation protocols are of key importance for ensuring safe MRI imaging in patients with CIED.

  • Open Access

    MAGNETIC RESONANCE IMAGING IN THE ASSESSMENT OF FETAL CENTRAL NERVOUS SYSTEM ANOMALIES

    by Edina Salkić, Fuad Julardžija, Adnan Šehić, Merim Jusufbegović, Amela Sofić, Meris Jušić, Jasmina Bajrović

    Introduction: Fetal CNS anomalies are among the most severe and common anomalies with an incidence of 1: 100 to 1: 500 in newborns, and depending on the type of anomaly, the diagnosis can only be made at certain periods of pregnancy. The prenatal US is an effective primary imaging modality for the depiction of these anomalies, and MRI is a method that provides useful confirmation and resolves the suspicion of the diagnosis made on prenatal ultrasound. In situations where ultrasound examination is difficult, fetal MRI can provide superior information, thanks to its many advantages. The aim of this study was to determine the importance of prenatal MRI in making an accurate diagnosis and assessment of fetal CNS anomalies after neurosonographic suspicion, and in detecting additional anomalies missed on ultrasound, which influences clinical decision making and anomaly outcomes. Material and methods: For this research, which was designed as a systematic review of the primary scientific research literature, numerous articles were used, i.e.17 scientific research papers, published within the relevant scientific research online databases such as PubMed, Medline, Google Scholar, and the same were published in English in the period from 2015 to 2021. Results: From the assessment of the quality of studies with cohort design it can be concluded that most of the studies used in this systematic review are in the category of high-quality studies (11 in total), with a smaller number of medium-quality studies (6 in total). In a total of 575 cases, MRI confirmed the ultrasound diagnosis and agreed with it in 59.8% of cases, while in 20.2% of cases it changed the diagnosis, i.e. in 16.5%, it rejected the ultrasound diagnosis. Additional anomalies detected only on MRI occurred in 236/1225 cases, which totals 19.3% of additional anomalies. Termination of pregnancy was reported in 82/317 cases, accounting for 25.9%, while in a total of 176 cases the pregnancy continued. A total of 11 cases of neonatal death were reported, and the number of stillbirths or deaths after birth was reported in 8 cases. Conclusion: MRI using T2W SSFSE sequences in 3 planes, T1W and DWI in the axial plane is a complementary modality to prenatal ultrasound in making an accurate diagnosis and assessment of CNS anomalies, and detecting associated anomalies previously missed on ultrasound.

  • Open Access

    DIAGNOSTIC REFERENCE LEVELS IN DENTAL RADIOLOGY: A SYSTEMATIC REVIEW

    by Alenka Matjašič

    Purpose: The purpose of this work was to review published articles in the fi eld of diagnostic reference levels in dental radiology, and to determine which areas have not been covered yet and require further scientifi c studies. The aim was also to determine if there are any dose optimization procedures suggested after DRL establishment. Materials and methods: A systematic review was performed using the Science Direct, PubMed, CINAHL (via EBSCOhost) and Dentistry & Oral Sciences Source (via EBSCOhost) databases, following the Cochrane Network study design guidelines. Articles were analysed and presented by author, year of publication, country of origin, technology (e.g. digital radiography, computed radiography and fi lm-screen), radiographic type (e.g. intraoral, panoramic and CBCT), units of measurement and main conclusions for each study. Results: Thirteen scientifi c articles on dose reference values in dental radiology were evaluated. Full-access articles published between 2001 and 2021 were used, and both reviews and original research articles were included. The studies address the defi nition or analysis of DRLs in intraoral and panoramic dental imaging and in dental CBCT imaging. Many studies report results based on diff erent image-receiving systems (e.g. DR, CR and fi lm-screen). The fi lm-screen system yielded the highest dose values of all three systems. All studies reviewed describe DRLs for the adult population, while only four also describe paediatric DRLs. Conclusion: Most EU countries have not yet set national DRLs for dental radiology. Most studies set or revise DRLs at the national level and compare them with guidelines from literature and from similar studies conducted in other countries. Most of these studies observed DRLs in the adult population. DRLs should also be set in the fi eld of dental CBCT imaging, as the use of this technology is rapidly increasing and the dose levels are incomparably higher than in general dental radiography. Keywords: dental radiography, diagnostic reference levels, intraoral imaging, panoramic dental imaging.


  • Image quality in abdominal CT: A comparison of two reconstruction algorithms in Filtered Back Projection (FBP)

    by Albertina Rusandu, Adrian Beck, Atle Hegge, Gabriele Engh

    Objectives: The aim of this study was to evaluate the effect of the choice of kernel on the image quality in abdominal CT images with focus on liver lesion visibility. Methods: In this comparative study 84 abdominal CT examinations of patients with liver lesions that included parallel series reconstructed with two different kernels (B30 and B45) were analyzed. The subjective assessment of image quality was performed using visual grading analysis based on anatomical criteria, liver lesion visibility and perceived image quality. Objective image quality was assessed by measurements of Hounsfield unit (HU) values (average and standard deviation) in abdominal organs and calculations of contrast-to-noise ratios (CNR). Results: B30 kernel performed significantly better than B45 in all criteria except for sharpness. The most considerable improvement of the image quality was in terms of subjective experienced image noise, overall diagnostic image quality and visually sharp reproduction of liver lesions. The physical measurements showed that CNR increased by up to 46% when using B30. Conclusions: Using a B30 kernel algorithm for image reconstruction reduces noise and by that improves image quality and diagnostic accuracy significantly when compared to B45.


  • Open Access

    FLASH RADIOTHERAPY AS NEW PERSPECTIVE IN RADIOTHERAPY TECHNOLOGY

    by Kuralt Matej, Valerija Žager Marciuš

    Purpose: The purpose of this article is to present FLASH radiotherapy (FLASH-RT) as a new radiation therapy method, to explain its mechanisms of action, to present possible sources and devices of radiation and to identify its advantages and disadvantages compared to conventional radiotherapy (CONV-RT). Methods: Numerous articles were reviewed for this study in a scientific research online database (PubMed) that were published in the last 10 years (2012-2022). We used PRISMA model to simplify our research and we gathered 14 articles that described the basic features of FLASH-RT. Results and Discussion: Most studies have found that FLASH-RT reduces toxicity to healthy tissues adjacent to the tumour. The majority of studies showed the same anti-tumour effect as CONV-RT, some even better. At present, there is a lack of suitable radiation devices for the use of FLASH-RT, and it will be necessary to adapt existing devices. Conclusion: FLASH-RT could be used in highly radioresistant tumours where CONV-RT would cause too much damage to healthy tissue with increase in radiation dose. It could also be useful in tumours where CONV-RT is successful but too toxic for healthy tissue adjacent to the tumour. A lot of research is needed before clinical implementation of FLASH-RT, to find out an optimal: dose rate, dose for different types of cancer and with most favorable effect/toxicity ratio, and technical solution (i.e. radiation source). Keywords: FLASH radiotherapy, conventional radiotherapy, toxicity to healthy tissues, antitumour effect

  • Open Access

    MRI findings in serous atrophy of bone marrow in spinal imaging

    by Andrej Breznik, Tomaž Zakrajšek, Boris Turk

    Introduction: Serous atrophy of bone marrow (SABM) is a rare, and potentially reversible, cause of diffuse look, irregular bone marrow and subcutaneous adipose tissue appearances on magnetic-resonance imaging (MRI). SABM has also been named gelatinous bone marrow transformation (GTMB) or ‘starvation marrow’. Purpose: The aim of the article is to represent a case report of ‘flip-flop’ phenomenon in SABM and GTBM pathology. Material and methods: This case report highlights an unexpected image appearance of an occurrence ‘flip-flop’ effect which is characteristic in the condition of serous atrophy of bone marrow (SABM). The literature search was conducted using medical scientific electronic databases such as PubMed, ScienceDirect, Cochrane and Google Scholar. Results / Case Study: An 44-year old man was appointed for an MRI examination. MRI images result like a technical failure, but are actually a specific imaging pattern related to the clinical problem. For clarity of unexpected images appearances, the radiographer repeated scans on a second vendor of MRI machine, but there still was the same appearance, like on the first scanner. The result of the literature review and the characteristics indicate We describe an example of the »flipflop« phenomenon in SABM and GTBM. Discussion and Conclusion: Serous atrophy or gelatinous malformations of bone marrow is not a normal disease, but indicates an underlying illness that starves the bone marrow, particularly the fatty marrow. We describe a case report of ‘flip flop’ phenomenon in SABM and GTBM pathology, where MRI images result like a technical failure, but are actually a specific imaging pattern related to the clinical problem.

  • Open Access

    ESTIMATION OF CEREBROVASCULAR INSULT FREQUENCY IN EMERGENCY PATIENTS AT THE CLINICAL HOSPITAL CENTRE RIJEKA

    by Lara Kragulj, Maja Karic, Lovro Tkalcic, Ana Bozanic

    Purpose: Cerebrovascular stroke is defi ned as a sudden focal neurologic defi cit caused by cerebrovascular disease lasting longer than 24 hours. Cerebrovascular insult (CVI) is divided into ischemic and hemorrhagic. Along with heart disease and malignancies, cerebrovascular disease is the most common cause of mortality and disability in the modern world, attributing to this disease being the leading cause of disability across the globe. Diagnosis and identifi cation of the type of stroke requires imaging examination with computed tomography. A detailed history and imaging usually rule out the impersonation of a stroke. Computed tomography (CT) is one of the fi rst diagnostic modalities used to image the brain to identify the diff erence between ischemic and hemorrhagic stroke. The aim of this retrospective analysis was to estimate the incidence of cerebrovascular insult in patients who underwent CT brain examination in the Clinical Department of Radiology at Clinical Hospital Centre (CHC) Rijeka in the period from January 1, 2020, to December 31, 2020. Materials and methods: During this period, 255 data sets from patients' medical records were anonymously collected. The data search included patients who underwent CT of the brain with a clinical question about CVI. Results: The data analysis at CHC Rijeka showed that the incidence of CVI is slightly higher in the male population. It is commonly diagnosed in the population of 81-90 years. About half of the patients with suspected CVI had normal CT fi ndings. Conclusion: These results could serve as a guideline for targeting groups in preventive healthcare interventions and education. Keywords: computed tomography, cerebrovascular insult, ischemic stroke, hemorrhagic stroke