Transactions of the IRE Professional Group on Ultrasonic Engineering
Published by Institute of Electrical and Electronics Engineers (IEEE)
- Scilit
- Total Citations
- 0
- Total Publications
- 0
- Average Citations
- 0.00
- Cited Publications
- 0
- Cited Publications %
- 0%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 0
- Monthly Citation Metric (MCM)
- 0
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 0
- Max
- 0
- Citing Source Titles
- Citing Publishers
Latest Publications
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 26-42
Characteristics of Ultrasonic Delay Lines Using Quartz and Barium Titanate Ceramic Transducers
Previous analysis of the equivalent circuit for the ultrasonic delay line wag applied to quartz crystal transducers and a vitreous silica delay medium. The analysis has been extended to evaluate the use of other materials such as magnesium, aluminum, and steel, and to include BaTi03 ceramic transducers. Calculations show the decrease in loss to be expected as the impedance of the delay medium is decreased and conversely the increase in bandwidth to be expected as the impedance of the delay medium is increased. The increase in bandwidth resulting from symmetrical loading of the transducers is also evaluated. Modifications to the equivalent circuits for the case of BaTi03 ceramic transducers are considered. Theoretically losses can be reduced to 10 db or less using the ceramic transducers with a vitreous silica medium. The bandwidth is slightly less than for quartz crystal transducers. However, by utilizing higher impedance materials,. bandwidths approaching 100% should be achieved.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 26-42
Characteristics of Ultrasonic Delay Lines Using Quartz and Barium Titanate Ceramic Transducers
Previous analysis of the equivalent circuit for the ultrasonic delay line wag applied to quartz crystal transducers and a vitreous silica delay medium. The analysis has been extended to evaluate the use of other materials such as magnesium, aluminum, and steel, and to include BaTi03 ceramic transducers. Calculations show the decrease in loss to be expected as the impedance of the delay medium is decreased and conversely the increase in bandwidth to be expected as the impedance of the delay medium is increased. The increase in bandwidth resulting from symmetrical loading of the transducers is also evaluated. Modifications to the equivalent circuits for the case of BaTi03 ceramic transducers are considered. Theoretically losses can be reduced to 10 db or less using the ceramic transducers with a vitreous silica medium. The bandwidth is slightly less than for quartz crystal transducers. However, by utilizing higher impedance materials,. bandwidths approaching 100% should be achieved.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 48
A Temperature-Controlled Ultrasonic Solid Acoustic Delay Line (Abstract)
A temperature-controlled ultrasonic solid acoustic delay line designed for radar calibration purposes is described. It has a delay of 24.73 microseconds. ±0.1 microseconds over an ambient temperature range from -25° C to +60°C. It is designed for use at 60 megacycles and has a bandwidth of at least 8 megacycles and a loss not exceeding 60 db. when used with a 150 ohm termination, It gives at least five reflections with no greater than 74 db. loss. A compact form is accomplished by using a thermostatically controlled oven in the form of a plastic encasement around a hermetically sealed metal enclosed delay line. The delay element, of vitreous silica, is held at 50°C with a deviation of less than ±5°C therefrom over the ambient temperature range up to 55°C. Heater power consumption at 115 volts ac is approximately 20 watts during the heating cycle which constitutes about 25% of the time for a 25°C ambient. Life tests on oven units over approximately two years in the ambient range of 23°C to 28°C show variations in temperature at the delay element well within ±2°C. Details of the construction are discussed and performance data on the oven and delay line are shown.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 48
A Temperature-Controlled Ultrasonic Solid Acoustic Delay Line (Abstract)
A temperature-controlled ultrasonic solid acoustic delay line designed for radar calibration purposes is described. It has a delay of 24.73 microseconds. ±0.1 microseconds over an ambient temperature range from -25° C to +60°C. It is designed for use at 60 megacycles and has a bandwidth of at least 8 megacycles and a loss not exceeding 60 db. when used with a 150 ohm termination, It gives at least five reflections with no greater than 74 db. loss. A compact form is accomplished by using a thermostatically controlled oven in the form of a plastic encasement around a hermetically sealed metal enclosed delay line. The delay element, of vitreous silica, is held at 50°C with a deviation of less than ±5°C therefrom over the ambient temperature range up to 55°C. Heater power consumption at 115 volts ac is approximately 20 watts during the heating cycle which constitutes about 25% of the time for a 25°C ambient. Life tests on oven units over approximately two years in the ambient range of 23°C to 28°C show variations in temperature at the delay element well within ±2°C. Details of the construction are discussed and performance data on the oven and delay line are shown.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 43-47
Metal Cleaning and Its Improvement by the Use of Ultrasonics
Ultrasonics is one of the newest tools to be applied to metal cleaning. Through the years, abrasives, soaps, compounded alkaline materials, and solvents have been used to remove soils From metals. Trichlorethylene Solvent degreasing has had a wide reception in industry since its introduction in 1930. The DETREX SONICLEAN PROCESS combines sound energy and trichlorethylene solvent degreasing for metal cleaning. This is accomplished by immersing specially treated barium titanate transducers in chlorinated solvents, producing cleaning results previously unobtainable. Crossrod, conveyorized equipment incorporating constant distillation and filtration of the solvent in the ultrasonic chamber and providing a final vapor rinse and drying is now in use in industrial plants producing as many as 8,000 parts per hour.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 43-47
Metal Cleaning and Its Improvement by the Use of Ultrasonics
Ultrasonics is one of the newest tools to be applied to metal cleaning. Through the years, abrasives, soaps, compounded alkaline materials, and solvents have been used to remove soils From metals. Trichlorethylene Solvent degreasing has had a wide reception in industry since its introduction in 1930. The DETREX SONICLEAN PROCESS combines sound energy and trichlorethylene solvent degreasing for metal cleaning. This is accomplished by immersing specially treated barium titanate transducers in chlorinated solvents, producing cleaning results previously unobtainable. Crossrod, conveyorized equipment incorporating constant distillation and filtration of the solvent in the ultrasonic chamber and providing a final vapor rinse and drying is now in use in industrial plants producing as many as 8,000 parts per hour.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 14-25
A Non-Contact Micro-Displacement Meter
A method capable of detecting microinch displacements of a transducer surface vibrating in the fractional megacycle range has been developed. The dynamic displacements of a vibrating transducer are detected with the aid of a specialized frequency modulation system. The vibrating transducer face is incorporated into the system in a manner such that the center frequency of an oscillator is varied in accordance with the transducer vibrations. The frequency modulation system transforms the frequency, deviations into a corresponding amplitude varying signal. In this way, accurate measurements of transducer vibrations can readily be obtained. The system is inherently capable of detecting transducer displacements with equal facility in either air or a viscous fluid.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 14-25
A Non-Contact Micro-Displacement Meter
A method capable of detecting microinch displacements of a transducer surface vibrating in the fractional megacycle range has been developed. The dynamic displacements of a vibrating transducer are detected with the aid of a specialized frequency modulation system. The vibrating transducer face is incorporated into the system in a manner such that the center frequency of an oscillator is varied in accordance with the transducer vibrations. The frequency modulation system transforms the frequency, deviations into a corresponding amplitude varying signal. In this way, accurate measurements of transducer vibrations can readily be obtained. The system is inherently capable of detecting transducer displacements with equal facility in either air or a viscous fluid.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 49-63
The Acoustic Flowmeter Using Electroric Switching
The flowmeter described in this paper measures the velocity of a fluid by measuring the difference in times of transmission of an acoustic wave in the upstream and downstream directions. The acoustic wave is propagated in the fluid by pressing a barium titanate transducer against the outside wall of the tubing carrying the fluid. The wave is then picked up by a similar transducer acting as a receiver and mounted on the tubing a short distance away from the first transducer The reversal in direction of propagation is effected by interchanging the functions of the two transducers, i.e., making the transmitter the receiver and vice versa. The time measurement is made in terms of the phase difference between transmitted and received waves. The phase difference measured for propagation in one direction is compared with the phase difference measured for propagation in the reverse direction and the difference between these is an indication of the fluid velocity. This difference is measured with a synchronous rectifier. The transducer functions are switched rapidly enough so that, by means of electrical differencing of the two phase measurements, a continuous velocity indication is obtained. Two methods of switching the transducer functions and performing the synchronous rectification have been employed. The first method utilizes a mechanically driven switch and has been described previously.1 The second method uses an entirely electronic system to perform both functions. It is this electronic system that is described in this paper.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1, 49-63
The Acoustic Flowmeter Using Electroric Switching
The flowmeter described in this paper measures the velocity of a fluid by measuring the difference in times of transmission of an acoustic wave in the upstream and downstream directions. The acoustic wave is propagated in the fluid by pressing a barium titanate transducer against the outside wall of the tubing carrying the fluid. The wave is then picked up by a similar transducer acting as a receiver and mounted on the tubing a short distance away from the first transducer The reversal in direction of propagation is effected by interchanging the functions of the two transducers, i.e., making the transmitter the receiver and vice versa. The time measurement is made in terms of the phase difference between transmitted and received waves. The phase difference measured for propagation in one direction is compared with the phase difference measured for propagation in the reverse direction and the difference between these is an indication of the fluid velocity. This difference is measured with a synchronous rectifier. The transducer functions are switched rapidly enough so that, by means of electrical differencing of the two phase measurements, a continuous velocity indication is obtained. Two methods of switching the transducer functions and performing the synchronous rectification have been employed. The first method utilizes a mechanically driven switch and has been described previously.1 The second method uses an entirely electronic system to perform both functions. It is this electronic system that is described in this paper.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1 (0277626X) , 4-13
Ultrasound and Medicine (A Survey of Experimental Studies)
Experimental investigations indicate that ultrasound may prove useful for therapy, for diagnosis and for biologic measurement. Ultrasound, although it may be dangerous in unskilled hands, is an excellent agent for the structural heating of living tissues. The term "structural heating" is used to denote heating at abrupt interfaces. The living organism presents numerous abrupt interfaces. Ultrasound promises to become a reliable diagnostic tool. Either the transmitted or the reflected ultrasonic energy can be used in this application. Tumors, galls tones, kidney stones, stones in the salivary glands, foreign bodies and abnormal collections of fluid have been located accurately. Preliminary observations on the use of ultrasound for certain biologic measurements are encouraging. Instrumentation for biologic measurement includes ultrasonic flow meters, devices for measuring thickness of same tissue structures and equipment for measuring the viscosity of blood.
- 5 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. PGUE-1 (0277626X) , 4-13
Ultrasound and Medicine (A Survey of Experimental Studies)
Experimental investigations indicate that ultrasound may prove useful for therapy, for diagnosis and for biologic measurement. Ultrasound, although it may be dangerous in unskilled hands, is an excellent agent for the structural heating of living tissues. The term "structural heating" is used to denote heating at abrupt interfaces. The living organism presents numerous abrupt interfaces. Ultrasound promises to become a reliable diagnostic tool. Either the transmitted or the reflected ultrasonic energy can be used in this application. Tumors, galls tones, kidney stones, stones in the salivary glands, foreign bodies and abnormal collections of fluid have been located accurately. Preliminary observations on the use of ultrasound for certain biologic measurements are encouraging. Instrumentation for biologic measurement includes ultrasonic flow meters, devices for measuring thickness of same tissue structures and equipment for measuring the viscosity of blood.
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 6-15
Ultrasonic Atomization of Liquids
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 6-15
Ultrasonic Atomization of Liquids
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 1
PGUE Award for 1957
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 1
PGUE Award for 1957
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 2
Biographical Notes on the Award Winners
Biographies of Dr. Herman Epstein, Mr. Oscar B. Stram, and Dr. John E. May, Jr.
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 2
Biographical Notes on the Award Winners
Biographies of Dr. Herman Epstein, Mr. Oscar B. Stram, and Dr. John E. May, Jr.
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 3-5
An Ultrasonic Cleaner for Hypodermic Needles and Similar Small Bore Apparatus
The authors investiagte ultrasonic leaning, with emphasis on its application to cleaning small parts. The ultrasonic equipment used at present for cleaning medical apparatus has not been effective in removing the coagulated blood from the inside of hypodermic needles. A design is described which has successfully removed the dried blood from hypodermic needles in a relatively short period of time. Preliminary experiments indicate that this system may also be sterilizing the needles at the same time as it is cleaning them.
- 1 February 1959
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the IRE Professional Group on Ultrasonic Engineering
- Vol. 6 (1) , 3-5
An Ultrasonic Cleaner for Hypodermic Needles and Similar Small Bore Apparatus
The authors investiagte ultrasonic leaning, with emphasis on its application to cleaning small parts. The ultrasonic equipment used at present for cleaning medical apparatus has not been effective in removing the coagulated blood from the inside of hypodermic needles. A design is described which has successfully removed the dried blood from hypodermic needles in a relatively short period of time. Preliminary experiments indicate that this system may also be sterilizing the needles at the same time as it is cleaning them.