Jurnal Elektro dan Mesin Terapan
Published by Politeknik Caltex Riau
- Scilit
- Combustion
- Food Science & Technology
- Electrical Energy Management
- Energy Systems & Technologies
- Power Systems & Electric Vehicles
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 17
- Total Publications
- 51
- Average Citations
- 0.33
- Cited Publications
- 13
- Cited Publications %
- 25.5%
- Self Citations
- 2
- Self Citations %
- 11.8%
- Q1
- 0
- Med
- 0
- Q3
- 1
- 99%
- 3
- Max
- 3
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 31-41
Voltage Flicker Analysis due to the Starting of 250 kW Three-Phase Induction Motor at the Karah Pump House, Surabaya
This study aims to analyze the causes of voltage flicker during the starting process of a three-phase induction motor at the Karah Pump House in Surabaya. The use of high power induction motors is essential for supporting flood control systems; however, conventional starting methods such as Direct On Line (DOL) and Star-Delta can generate high inrush currents that negatively affect power quality. The research evaluates starting current characteristics, distribution system impedance, and the resulting voltage flicker based on IEC standards. The analysis shows that the DOL method produces greater voltage drop and voltage flicker compared to the Star Delta method. Although the Star-Delta method is able to reduce voltage disturbances, both methods still have the potential to exceed standard flicker limits if the distribution system is not equipped with adequate mitigation devices. Therefore, proper starting current control is an important factor in maintaining power quality and ensuring the stability of the pump house distribution system.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 31-41
Open AccessVoltage Flicker Analysis due to the Starting of 250 kW Three-Phase Induction Motor at the Karah Pump House, Surabaya
This study aims to analyze the causes of voltage flicker during the starting process of a three-phase induction motor at the Karah Pump House in Surabaya. The use of high power induction motors is essential for supporting flood control systems; however, conventional starting methods such as Direct On Line (DOL) and Star-Delta can generate high inrush currents that negatively affect power quality. The research evaluates starting current characteristics, distribution system impedance, and the resulting voltage flicker based on IEC standards. The analysis shows that the DOL method produces greater voltage drop and voltage flicker compared to the Star Delta method. Although the Star-Delta method is able to reduce voltage disturbances, both methods still have the potential to exceed standard flicker limits if the distribution system is not equipped with adequate mitigation devices. Therefore, proper starting current control is an important factor in maintaining power quality and ensuring the stability of the pump house distribution system.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 56-62
Studi Kelayakan Perbandingan PLTS Rooftop 15kWp dan 20kWp di Gereja Katolik Paroki St. Konrad Martubung Menggunakan Software PVSyst
Penelitian ini bertujuan untuk menganalisis kelayakan pembangunan PLTS rooftop sebagai sumber energi alternatif di Gereja Katolik Paroki St. Konrad Martubung dengan luaran akhir berupa rekomendasi sistem PLTS rooftop yang dinyatakan layak baik dari sisi teknis maupun ekonomi untuk direalisasikan pada bangunan Gereja Katolik St. Konrad Martubung. Studi dilakukan dengan mempertimbangkan potensi radiasi matahari, kebutuhan energi listrik gereja, Kapasitas sistem yang dapat dipasang, serta estimasi biaya investasi. Analisis kelayakan dilakukan dengan menggunakan software PVSyst. Hasil studi menunjukkan bahwa iklim di lokasi penelitian memungkinkan pemasangan PLTS dengan kapasitas optimal 15–20 kWp. Penelitian ini memberikan data perbandingan antara sistem berkapasitas 15kWp dan 20kWp. hasil simulasi menunjukkan bahwa kedua sistem dinyatakan layak dari sisi teknis dan ekonomi dengan performa ratio 0,77, dan NPV bernilai positif serta nilai LCOE yang jauh lebih kecil dari tarif dasar listrik (Rp 585/kWh).
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 56-62
Open AccessStudi Kelayakan Perbandingan PLTS Rooftop 15kWp dan 20kWp di Gereja Katolik Paroki St. Konrad Martubung Menggunakan Software PVSyst
Penelitian ini bertujuan untuk menganalisis kelayakan pembangunan PLTS rooftop sebagai sumber energi alternatif di Gereja Katolik Paroki St. Konrad Martubung dengan luaran akhir berupa rekomendasi sistem PLTS rooftop yang dinyatakan layak baik dari sisi teknis maupun ekonomi untuk direalisasikan pada bangunan Gereja Katolik St. Konrad Martubung. Studi dilakukan dengan mempertimbangkan potensi radiasi matahari, kebutuhan energi listrik gereja, Kapasitas sistem yang dapat dipasang, serta estimasi biaya investasi. Analisis kelayakan dilakukan dengan menggunakan software PVSyst. Hasil studi menunjukkan bahwa iklim di lokasi penelitian memungkinkan pemasangan PLTS dengan kapasitas optimal 15–20 kWp. Penelitian ini memberikan data perbandingan antara sistem berkapasitas 15kWp dan 20kWp. hasil simulasi menunjukkan bahwa kedua sistem dinyatakan layak dari sisi teknis dan ekonomi dengan performa ratio 0,77, dan NPV bernilai positif serta nilai LCOE yang jauh lebih kecil dari tarif dasar listrik (Rp 585/kWh).
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 20-30
Analisis Sebaran Badspot Jaringan 4G LTE berbasis Drive test Studi Kasus: Daerah Rural Kota Pekanbaru
Operator X merupakan salah satu penyedia layanan telekomunikasi terbesar di Pekanbaru yang telah mengembangkan jaringan 4G secara luas. Namun, performa jaringan di wilayah rural masih menghadapi berbagai tantangan, seperti keterbatasan infrastruktur, kondisi topografi yang kompleks, serta fluktuasi kepadatan pengguna. Penelitian ini bertujuan untuk menganalisis kinerja jaringan 4G Operator X di wilayah rural Kota Pekanbaru melalui pengukuran berbasis drive test menggunakan perangkat lunak berstandar industri. Fokus utama penelitian adalah identifikasi area dengan kualitas sinyal rendah (badspot), yang berpotensi menurunkan kualitas layanan. Pengukuran dilakukan pada 5 wilayah rural yang tersebar di tiga kecamatan. Hasil penelitian menunjukkan bahwa sebagian besar area yang diuji memiliki badspot, dengan temuan terbanyak berada di Jalan Abdul Rahman Hamid, Kecamatan Tenayan Raya, di mana 57,95% termasuk kategori RSRP sangat buruk serta teridentifikasi area blankspot. Faktor utama penyebab buruknya kualitas sinyal adalah arah pancaran antena sektoral yang tidak optimal terhadap area layanan serta keberadaan hambatan fisik berupa vegetasi tinggi dan lebat. Temuan ini menunjukkan pentingnya optimalisasi desain jaringan untuk meningkatkan kualitas layanan di wilayah rural.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 20-30
Open AccessAnalisis Sebaran Badspot Jaringan 4G LTE berbasis Drive test Studi Kasus: Daerah Rural Kota Pekanbaru
Operator X merupakan salah satu penyedia layanan telekomunikasi terbesar di Pekanbaru yang telah mengembangkan jaringan 4G secara luas. Namun, performa jaringan di wilayah rural masih menghadapi berbagai tantangan, seperti keterbatasan infrastruktur, kondisi topografi yang kompleks, serta fluktuasi kepadatan pengguna. Penelitian ini bertujuan untuk menganalisis kinerja jaringan 4G Operator X di wilayah rural Kota Pekanbaru melalui pengukuran berbasis drive test menggunakan perangkat lunak berstandar industri. Fokus utama penelitian adalah identifikasi area dengan kualitas sinyal rendah (badspot), yang berpotensi menurunkan kualitas layanan. Pengukuran dilakukan pada 5 wilayah rural yang tersebar di tiga kecamatan. Hasil penelitian menunjukkan bahwa sebagian besar area yang diuji memiliki badspot, dengan temuan terbanyak berada di Jalan Abdul Rahman Hamid, Kecamatan Tenayan Raya, di mana 57,95% termasuk kategori RSRP sangat buruk serta teridentifikasi area blankspot. Faktor utama penyebab buruknya kualitas sinyal adalah arah pancaran antena sektoral yang tidak optimal terhadap area layanan serta keberadaan hambatan fisik berupa vegetasi tinggi dan lebat. Temuan ini menunjukkan pentingnya optimalisasi desain jaringan untuk meningkatkan kualitas layanan di wilayah rural.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 13-19
Sistem Smart Sorting Trash Box Berbasis Mikrokontroler Sebagai Smart Environment
Meningkatnya volume sampah rumah tangga dan kurangnya kesadaran masyarakat dalam memilah sampah secara mandiri menjadi kendala utama dalam manajemen limbah perkotaan. Pemilahan sampah yang tidak efisien menghambat proses daur ulang dan berdampak buruk pada ekosistem. Penelitian ini bertujuan untuk merancang dan mengimplementasikan Smart Sorting Trash Box, sebuah purwarupa tempat sampah pintar berbasis mikrokontroler yang mampu memilah sampah secara otomatis berdasarkan jenisnya (Logam dan No-Logam). Pengembangan sistem ini dilakukan melalui pendekatan Research and Development dengan model Waterfall yang mengintegrasikan mikrokontroler ESP32, sensor induktif, sensor kapasitif, serta mekanisme motor servo. Berdasarkan pengujian terhadap berbagai sampel seperti kaleng, paku, plastik, dan kertas, sistem menunjukkan performa teknis yang konsisten dengan tingkat akurasi tinggi melalui respons sensor aktif pada rentang jarak 0,5–10 mm. Keberhasilan prototipe dalam memisahkan limbah secara presisi di sumbernya mengonfirmasi kesiapan teknologi ini untuk memperkuat ekosistem lingkungan cerdas. Optimalisasi jangka panjang dapat diarahkan pada perluasan jangkauan deteksi sensor serta penguatan akurasi pemindaian terhadap material dengan dimensi dan ketebalan yang lebih variatif guna meningkatkan nilai guna sistem di masyarakat.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 13-19
Open AccessSistem Smart Sorting Trash Box Berbasis Mikrokontroler Sebagai Smart Environment
Meningkatnya volume sampah rumah tangga dan kurangnya kesadaran masyarakat dalam memilah sampah secara mandiri menjadi kendala utama dalam manajemen limbah perkotaan. Pemilahan sampah yang tidak efisien menghambat proses daur ulang dan berdampak buruk pada ekosistem. Penelitian ini bertujuan untuk merancang dan mengimplementasikan Smart Sorting Trash Box, sebuah purwarupa tempat sampah pintar berbasis mikrokontroler yang mampu memilah sampah secara otomatis berdasarkan jenisnya (Logam dan No-Logam). Pengembangan sistem ini dilakukan melalui pendekatan Research and Development dengan model Waterfall yang mengintegrasikan mikrokontroler ESP32, sensor induktif, sensor kapasitif, serta mekanisme motor servo. Berdasarkan pengujian terhadap berbagai sampel seperti kaleng, paku, plastik, dan kertas, sistem menunjukkan performa teknis yang konsisten dengan tingkat akurasi tinggi melalui respons sensor aktif pada rentang jarak 0,5–10 mm. Keberhasilan prototipe dalam memisahkan limbah secara presisi di sumbernya mengonfirmasi kesiapan teknologi ini untuk memperkuat ekosistem lingkungan cerdas. Optimalisasi jangka panjang dapat diarahkan pada perluasan jangkauan deteksi sensor serta penguatan akurasi pemindaian terhadap material dengan dimensi dan ketebalan yang lebih variatif guna meningkatkan nilai guna sistem di masyarakat.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 97-107
Structural Optimization of H-Type Press Table Design Parameters Using Taguchi Method and Finite Element Analysis
This study aims to analyse the influence of load variation, material type, and thickness on the Von Mises stress values of an H-type press table using Design of Experiments (DOE) based simulation approach. This study was conducted to determine the maximum strength of the press machine table design as an effort to prevent structural failure during the operation of the press machine. The “Smaller is Better” signal-to-noise (S/N) ratio criterion was applied to obtain the minimum stress value under loading conditions. Lower stress values indicate a safer load distribution, which can improve the safety factor of the H-type press machine table design. In this study, three load levels were used: 10, 20, and 30 tonnes; three material types: Mild Steel, High-Strength Steel, and Alloy Steel; and three variations in press table thickness: 30, 40, and 50 mm. The simulation results show that as the applied load increases, the Von Mises stress also increases. Changes in the thickness of the press table have the greatest influence on stability or response variation, while the material type has a relatively small influence compared to the other factors. Changes in thickness affect the Von Mises stress value depending on the material type, and vice versa. This indicates that the three parameters interact, meaning a change in one factor can produce different results depending on other conditions. The highest average stress value was obtained on the press table at 104.45 MPa for the combination of High-Strength Steel with a thickness of 30 mm and a load of 30 tonnes, while the lowest stress value of 21.97 MPa was obtained for Alloy Steel with a thickness of 50 mm and a load of 10 tonnes.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 97-107
Open AccessStructural Optimization of H-Type Press Table Design Parameters Using Taguchi Method and Finite Element Analysis
This study aims to analyse the influence of load variation, material type, and thickness on the Von Mises stress values of an H-type press table using Design of Experiments (DOE) based simulation approach. This study was conducted to determine the maximum strength of the press machine table design as an effort to prevent structural failure during the operation of the press machine. The “Smaller is Better” signal-to-noise (S/N) ratio criterion was applied to obtain the minimum stress value under loading conditions. Lower stress values indicate a safer load distribution, which can improve the safety factor of the H-type press machine table design. In this study, three load levels were used: 10, 20, and 30 tonnes; three material types: Mild Steel, High-Strength Steel, and Alloy Steel; and three variations in press table thickness: 30, 40, and 50 mm. The simulation results show that as the applied load increases, the Von Mises stress also increases. Changes in the thickness of the press table have the greatest influence on stability or response variation, while the material type has a relatively small influence compared to the other factors. Changes in thickness affect the Von Mises stress value depending on the material type, and vice versa. This indicates that the three parameters interact, meaning a change in one factor can produce different results depending on other conditions. The highest average stress value was obtained on the press table at 104.45 MPa for the combination of High-Strength Steel with a thickness of 30 mm and a load of 30 tonnes, while the lowest stress value of 21.97 MPa was obtained for Alloy Steel with a thickness of 50 mm and a load of 10 tonnes.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 89-96
Structured Review of Electromagnetic Emission Measurement Methodologies for EMC Verification of UAV Avionics Systems
Electromagnetic emissions in unmanned aerial vehicle (UAV) avionics are increasingly critical because power, flight control, navigation, communication, and payload subsystems are integrated within compact compartments and dense wiring harnesses, increasing internal electromagnetic interference risk. This study aims to synthesize measurement methodologies for UAV electromagnetic emissions and compare their facilities, observed parameters, and applicable standards. A qualitative structured literature review was conducted on 10 core studies selected from IEEE Xplore, ScienceDirect, SpringerLink, MDPI, and Scopus using relevance, recency, technical comparability, and standards-based criteria. The review identifies four recurring methodological clusters: chamber based radiated emission testing, conducted-path and cable-coupling analysis, receiver and sensor performance-based assessment, and simulation with near field pre-compliance evaluation. The findings show that cable routing, grounding-bonding quality, shielding-filtering practice, test distance, and polarization strongly influence emission levels, operational degradation, and pass/fail outcomes. The review concludes that the most robust strategy is a staged workflow from simulation and pre-compliance screening to controlled verification and installation-level mitigation validation, enabling a more efficient EMC path with lower redesign and certification risk.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 89-96
Open AccessStructured Review of Electromagnetic Emission Measurement Methodologies for EMC Verification of UAV Avionics Systems
Electromagnetic emissions in unmanned aerial vehicle (UAV) avionics are increasingly critical because power, flight control, navigation, communication, and payload subsystems are integrated within compact compartments and dense wiring harnesses, increasing internal electromagnetic interference risk. This study aims to synthesize measurement methodologies for UAV electromagnetic emissions and compare their facilities, observed parameters, and applicable standards. A qualitative structured literature review was conducted on 10 core studies selected from IEEE Xplore, ScienceDirect, SpringerLink, MDPI, and Scopus using relevance, recency, technical comparability, and standards-based criteria. The review identifies four recurring methodological clusters: chamber based radiated emission testing, conducted-path and cable-coupling analysis, receiver and sensor performance-based assessment, and simulation with near field pre-compliance evaluation. The findings show that cable routing, grounding-bonding quality, shielding-filtering practice, test distance, and polarization strongly influence emission levels, operational degradation, and pass/fail outcomes. The review concludes that the most robust strategy is a staged workflow from simulation and pre-compliance screening to controlled verification and installation-level mitigation validation, enabling a more efficient EMC path with lower redesign and certification risk.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 108-119
Numerical Study of the Effect of Grid Number and Viscous Model on Fin and Tube Heat Exchanger Performance
The fin and tube heat exchanger (FTHE) has attracted attention among technicians and researchers because of its performance. This research was conducted to determine the effect of variations in the number of grids and viscous models on FTHE on its thermal performance using the Fluent application in the Computational Fluid Dynamics computer program, which was varied against the number of grids and viscous models in various variations of fluid flow speed with a constant heat flux of 100 W. The best results of this research were obtained with the variation of the longitudinal pitch ratio of 14.5 mm with a heat transfer coefficient value of 97.24 W/m2K, while the ratio of the transverse pitch direction of 11.7 mm with a heat transfer coefficient value of 107.82 W/m2K. The best results of this research were obtained at variations in the number of grids of 358456 in variations of the viscous k-w Standard model with an average FTHE temperature value of 21.35 oC and a maximum heat transfer coefficient value of 101.74 W/m2K. These results confirm that the variation of the number of grids of 358456 in the variation of the viscous k-w Standard model allows the numerical study model to be recommended and used for practical applications on machine devices, and can be applied directly in the field. Keywords: Fin and Tube Heat Exchanger (FTHE), Longitudinal Pitch, Transversal Pitch, Performa.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 108-119
Open AccessNumerical Study of the Effect of Grid Number and Viscous Model on Fin and Tube Heat Exchanger Performance
The fin and tube heat exchanger (FTHE) has attracted attention among technicians and researchers because of its performance. This research was conducted to determine the effect of variations in the number of grids and viscous models on FTHE on its thermal performance using the Fluent application in the Computational Fluid Dynamics computer program, which was varied against the number of grids and viscous models in various variations of fluid flow speed with a constant heat flux of 100 W. The best results of this research were obtained with the variation of the longitudinal pitch ratio of 14.5 mm with a heat transfer coefficient value of 97.24 W/m2K, while the ratio of the transverse pitch direction of 11.7 mm with a heat transfer coefficient value of 107.82 W/m2K. The best results of this research were obtained at variations in the number of grids of 358456 in variations of the viscous k-w Standard model with an average FTHE temperature value of 21.35 oC and a maximum heat transfer coefficient value of 101.74 W/m2K. These results confirm that the variation of the number of grids of 358456 in the variation of the viscous k-w Standard model allows the numerical study model to be recommended and used for practical applications on machine devices, and can be applied directly in the field. Keywords: Fin and Tube Heat Exchanger (FTHE), Longitudinal Pitch, Transversal Pitch, Performa.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 49-55
Pengaruh Posisi Roda terhadap Laju Keausan Blok Rem Komposit Pada Lokomotif Kereta Api
Penelitian ini bertujuan untuk menganalisis laju keausan blok rem komposit yang terdapat pada lokomotif CC 205. Material Komposit sudah banyak digunakan sebagai blok rem, hal ini dikarenakan blok rem komposit memiliki ketahanan aus yang baik dibandingkan material besi. Penelitian ini dilakukan dengan metode pengukuran dimensi dan massa pada 12 spesimen kampas rem dibagian kanan 6 set dan dibagian kiri 6 set yang digunakan selama 3 bulan dengan 30 kali perjalanan. Data yang didapat meliputi waktu pengereman rata-rata 5,6 detik dengan 78 kali pengereman per perjalanan. Laju keausan dihitung menggunakan persamaan specific wear rate (kehilangan massa per satuan luas penampang per satuan waktu pengereman) berdasarkan selisih massa awal dan akhir, luas penampang, dan waktu total pengereman. Hasil penelitian menunjukkan variasi laju keausan yang bernilai diantara 1,08 x 10-7 gr/mm2.detik hingga 6,71 10-7 gr/mm2.detik. Laju keausan terbesar berada di spesimen 2B kanan, 2B kiri dan 4D kanan, sedangkan laju keausan terendah pada spesimen 1A kanan dan kiri. Faktor-faktor yang mempengaruhi keausan diantaranya pengereman mendadak, aliran udara yang terhambat, tekanan yang tidak stabil, pemasangan blok rem yang tidak seragam, serta tingkat kekasaran permukaan roda. Ketebalan sisa kampas rem bervariasi antara 18-41 mm dari ketebalan awal 50 mm. Hasil penelitian ini diharapkan menjadi dasar rekomendasi material rem yang optimal serta jadwal pemeliharaan yang lebih efisien dan aman.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 49-55
Open AccessPengaruh Posisi Roda terhadap Laju Keausan Blok Rem Komposit Pada Lokomotif Kereta Api
Penelitian ini bertujuan untuk menganalisis laju keausan blok rem komposit yang terdapat pada lokomotif CC 205. Material Komposit sudah banyak digunakan sebagai blok rem, hal ini dikarenakan blok rem komposit memiliki ketahanan aus yang baik dibandingkan material besi. Penelitian ini dilakukan dengan metode pengukuran dimensi dan massa pada 12 spesimen kampas rem dibagian kanan 6 set dan dibagian kiri 6 set yang digunakan selama 3 bulan dengan 30 kali perjalanan. Data yang didapat meliputi waktu pengereman rata-rata 5,6 detik dengan 78 kali pengereman per perjalanan. Laju keausan dihitung menggunakan persamaan specific wear rate (kehilangan massa per satuan luas penampang per satuan waktu pengereman) berdasarkan selisih massa awal dan akhir, luas penampang, dan waktu total pengereman. Hasil penelitian menunjukkan variasi laju keausan yang bernilai diantara 1,08 x 10-7 gr/mm2.detik hingga 6,71 10-7 gr/mm2.detik. Laju keausan terbesar berada di spesimen 2B kanan, 2B kiri dan 4D kanan, sedangkan laju keausan terendah pada spesimen 1A kanan dan kiri. Faktor-faktor yang mempengaruhi keausan diantaranya pengereman mendadak, aliran udara yang terhambat, tekanan yang tidak stabil, pemasangan blok rem yang tidak seragam, serta tingkat kekasaran permukaan roda. Ketebalan sisa kampas rem bervariasi antara 18-41 mm dari ketebalan awal 50 mm. Hasil penelitian ini diharapkan menjadi dasar rekomendasi material rem yang optimal serta jadwal pemeliharaan yang lebih efisien dan aman.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 63-74
Evaluasi Kinerja Mesin Diesel Berbahan Bakar B30 Dengan Nano Aditif Hexagonal Boron Nitrida (hBN) Hasil Eksfoliasi
Gesekan internal pada mesin pembakaran dalam berkontribusi besar terhadap kehilangan energi dan peningkatan konsumsi bahan bakar. Untuk meningkatkan efisiensi energi dan mendukung pemanfaatan biodiesel B30, penelitian ini bertujuan mengevaluasi pengaruh penambahan nanopartikel Hexagonal Boron Nitride (hBN) hasil eksfoliasi sebesar 0,5% massa sebagai aditif pelumas. Pengujian dilakukan pada mesin diesel satu silinder menggunakan Durability Test selama 200 jam mengikuti siklus Engine Manufacturers Association (EMA), dengan perbandingan pelumas tanpa aditif (hBN 0%) dan pelumas dengan aditif (hBN 0,5%). Hasil pengujian menunjukkan bahwa penambahan hBN meningkatkan performa termomekanis mesin, ditunjukkan oleh kenaikan rata-rata daya sebesar 1,56% dan peningkatan torsi maksimum sebesar 3,6%. Temuan utama penelitian ini adalah penurunan rata-rata Specific Fuel Oil Consumption (SFOC) sebesar 6,36% pada kondisi rated power. Perbedaan kinerja tersebut terkonfirmasi signifikan secara statistik (p < 0,05), dengan deviasi data yang berada dalam batas pengulangan pengujian. Peningkatan efisiensi ini dikaitkan dengan mekanisme pelumasan rolling nano dari partikel hBN yang efektif menurunkan gesekan internal. Secara keseluruhan, hasil penelitian menegaskan bahwa aditif hBN berpotensi meningkatkan efisiensi bahan bakar dan mendukung keberlanjutan operasional mesin diesel berbahan bakar biodiesel B30.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 63-74
Open AccessEvaluasi Kinerja Mesin Diesel Berbahan Bakar B30 Dengan Nano Aditif Hexagonal Boron Nitrida (hBN) Hasil Eksfoliasi
Gesekan internal pada mesin pembakaran dalam berkontribusi besar terhadap kehilangan energi dan peningkatan konsumsi bahan bakar. Untuk meningkatkan efisiensi energi dan mendukung pemanfaatan biodiesel B30, penelitian ini bertujuan mengevaluasi pengaruh penambahan nanopartikel Hexagonal Boron Nitride (hBN) hasil eksfoliasi sebesar 0,5% massa sebagai aditif pelumas. Pengujian dilakukan pada mesin diesel satu silinder menggunakan Durability Test selama 200 jam mengikuti siklus Engine Manufacturers Association (EMA), dengan perbandingan pelumas tanpa aditif (hBN 0%) dan pelumas dengan aditif (hBN 0,5%). Hasil pengujian menunjukkan bahwa penambahan hBN meningkatkan performa termomekanis mesin, ditunjukkan oleh kenaikan rata-rata daya sebesar 1,56% dan peningkatan torsi maksimum sebesar 3,6%. Temuan utama penelitian ini adalah penurunan rata-rata Specific Fuel Oil Consumption (SFOC) sebesar 6,36% pada kondisi rated power. Perbedaan kinerja tersebut terkonfirmasi signifikan secara statistik (p < 0,05), dengan deviasi data yang berada dalam batas pengulangan pengujian. Peningkatan efisiensi ini dikaitkan dengan mekanisme pelumasan rolling nano dari partikel hBN yang efektif menurunkan gesekan internal. Secara keseluruhan, hasil penelitian menegaskan bahwa aditif hBN berpotensi meningkatkan efisiensi bahan bakar dan mendukung keberlanjutan operasional mesin diesel berbahan bakar biodiesel B30.
- Open Access
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 75-88
A Design and Implementation of an IoT-Based Heavy Equipment Engine Overheating Prevention System Using LoRa Communication for Remote Monitoring and Cooling Control
Bulldozer engines are highly susceptible to overheating during intensive operations, which can lead to severe mechanical damage and costly downtime. This study proposes an Internet of Things (IoT)-based overheat detection and automated cooling system to improve preventive maintenance in heavy machinery. The system utilizes a LilyGo-T Beam (ESP32) microcontroller integrated with a calibrated NTC thermistor sensor and LoRa communication operating at 923 MHz for long-range and low-power data transmission. Temperature data are displayed locally and transmitted to the Blynk IoT platform for real-time remote monitoring and notification when critical thresholds are exceeded. The developed prototype consists of a transmitter–receiver unit and an automated response mechanism that triggers both an alarm and a water-sprayer cooling system. Experimental validation included sensor calibration, thermal response testing, LoRa communication range assessment, and evaluation of cooling performance under various operating conditions. The results demonstrate accurate temperature measurement and reliable data transmission up to 950 meters. The automated water sprayer successfully reduced engine temperature from 80°C to 78.99°C, with an average recovery time of 12 minutes and 28 seconds. Cooling efficiency improved from 16.49% to 22.18%, indicating enhanced heat dissipation capability Overall, the proposed system offers a cost-effective, reliable, and scalable solution for preventing engine overheating in heavy equipment. By integrating IoT-based monitoring with automated cooling, this approach enhances operational performance, minimizes downtime, and extends engine lifespan.
- 31 May 2026
- Published by Politeknik Caltex Riau in Jurnal Elektro dan Mesin Terapan
- Vol. 12 (1) , 75-88
Open AccessA Design and Implementation of an IoT-Based Heavy Equipment Engine Overheating Prevention System Using LoRa Communication for Remote Monitoring and Cooling Control
Bulldozer engines are highly susceptible to overheating during intensive operations, which can lead to severe mechanical damage and costly downtime. This study proposes an Internet of Things (IoT)-based overheat detection and automated cooling system to improve preventive maintenance in heavy machinery. The system utilizes a LilyGo-T Beam (ESP32) microcontroller integrated with a calibrated NTC thermistor sensor and LoRa communication operating at 923 MHz for long-range and low-power data transmission. Temperature data are displayed locally and transmitted to the Blynk IoT platform for real-time remote monitoring and notification when critical thresholds are exceeded. The developed prototype consists of a transmitter–receiver unit and an automated response mechanism that triggers both an alarm and a water-sprayer cooling system. Experimental validation included sensor calibration, thermal response testing, LoRa communication range assessment, and evaluation of cooling performance under various operating conditions. The results demonstrate accurate temperature measurement and reliable data transmission up to 950 meters. The automated water sprayer successfully reduced engine temperature from 80°C to 78.99°C, with an average recovery time of 12 minutes and 28 seconds. Cooling efficiency improved from 16.49% to 22.18%, indicating enhanced heat dissipation capability Overall, the proposed system offers a cost-effective, reliable, and scalable solution for preventing engine overheating in heavy equipment. By integrating IoT-based monitoring with automated cooling, this approach enhances operational performance, minimizes downtime, and extends engine lifespan.