Journal of Radiography and Radiation Sciences

Published by Association of Radiographers of Nigeria

Abbrev: J. Radiogr. Radiat. Sci.
ISSN 2736-1071EISSN 2736-1063
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
81
2025 journal articles
0

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Biomedical Physics
32
Diagnostic & Therapeutic Ultrasound
16
Health Education & Remote Healthcare
9
Patient Care
8
Reproductive Health
7
Healthcare Policy
5
Obstetrics/Gynecology
5
Antibiotic & Antibacterial Agents
5
Urology
5
Legionella Infection
5

Top Countries

Publications in 2016-2026.

CountryPublications
Nigeria
4
United Kingdom
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
0
Total Publications
1
Average Citations
0.00
Cited Publications
0
Cited Publications %
0%
Self Citations
0
Self Citations %
0%

Metrics
h5_index
2
Monthly Citation Metric (MCM)
0

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
0
Max
0

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    CT features, Pathological findings and Clinical data of Follicular Dendritic Cell Sarcoma in the Mediastinum: Case Report and Literature Review

    by Yifan Wu, Yang Yang, Mazen Musa, Abdoulaye Issotina Zibrila, Zhang Zhengxiang, Mustafa Salimeen

    Follicular dendritic cell sarcoma (FDC sarcoma) is an uncommon neoplasm with few reported cases. We investigated the Computed Tomography (CT) appearance and pathological findings in a 43years-old lady diagnosed with mediastinal FDC sarcoma using pathological tests. It's usually confused with lymphoma. The literature was reviewed for previous FDC sarcoma reports. FDC sarcoma should be considered in asymptomatic patients with mediastinal lymph node lesions with a diameter of more than 1 cm and appear as an ill-defined mass with an arborizing pattern of necrosis. CD21(+) is a specific immunohistochemically marker for determining the pathological diagnosis of FDC sarcoma.

  • KNOWLEDGE AND PRACTICE OF IMAGING OF CHILDREN WITH SUSPECTED CASES OF NON-ACCIDENTAL INJURIES AMONG RADIOGRAPHERS WITHIN MAIDUGURI METROPOLIS, NORTHEASTERN NIGERIA

    by Geofery Lunti, Hadiza Ahmed, Muhammad Musa Abubakar, Flavious Bobuin Nkubli, Shatane Ibrahim Namba, Ahmadu Adamu

    Objectives: To assess the knowledge and practice of Non-accidental injuries (NAI) among radiographers practising within Maiduguri Metropolis. Methods: A cross-sectional study was conducted using a questionnaire to elicit information on knowledge and practice of imaging children with Non-accidental injuries. The information elicited from the questionnaire related to the following themes: Demographic characteristics, knowledge and practice of imaging children with NAI. Informed consent was sought from participants. Descriptive statistics (mean, frequencies) was used to analyse the data. Results: A total of 45 questionnaires were distributed to radiographers, and 36(80%) were completed and returned. A total of 63.9% (23) were males and 36.1% (13) were females. The majority 94.4% (34) of the respondents had knowledge of NAI. A total of 36.1% (13) of the respondents agreed that pediatric imaging is a recognized sub-speciality in radiography. A total of 63.9% (23) of the respondents agreed that the skeletal survey is the examination commonly requested in children with NAI, and the majority of the participants 86.1% (31) had no speciality training in paediatric imaging. A good majority of the participants 63.9% (23) understood that using a single film to image the whole body (baby-gram) was an obsolete examination. Conventional radiography with 63.9% (23) was the equipment mostly used for imaging children with NAI. Conclusion: This study found Radiographers have good knowledge and practice of imaging NAI in children, with some of them having sub-speciality training in pediatric imaging. Non-accidental injuries among children occur in our local environment and a majority of these go unnoticed as it is either not reported, under-reported or swept under the carpet the consequences of a child growing up in an abusive and or volatile environment, the medical and psychological impact on the life of the child cannot be overemphasized. Thus, radiographers play a vital role in the diagnosis and workup of children with NAI. Practice Implication: A good knowledge of non-accidental injury among healthcare providers will aid in the early identification of cases for appropriate recommendations and follow-up cases. Educational intervention has been recommended to aid in early identification and response to NAI in other to improve outcomes.

  • Surface Management in Prevention of Nosocomial Infections in Radiography Practice

    by Okafor H. Chioma Chioma, Nsofor Ifeoma, Okon Ime

    Background: For prevention of nosocomial infections in Radiography practice, it is imperative to disinfect surfaces used by all patients with appropriate disinfectants.Objective: To determine the disinfectants that are most active in eliminating micro-organisms identified on hard surfaces of equipment and accessories in the radiology department of a tertiary hospital. Methodology: Efficacy of Savlon (chlorohexidine), Jik (Sodium hydrochlorite), and Dettol (Chloroxylenol) were tested. Each examined surface was divided into three horizontal parts. Three BS medichem swabs were moistened with distilled water and used to collect sample along each surface at different points. The surfaces were cleaned with each undiluted disinfectant and allowed to dry for 20 minutes. Three different moistened swabs were used to collect another fresh sample. Chocolate agar was used to prepare the samples and later incubated in incumaxTM incubator for 24 hours at 370C. Colonies were identified under national light microscope.Results: Colony count before disinfection was one 150. After cleaning, it reduced to 60. The isolated organisms were: Staphycoccus aureus, Candida albicans, Pseudomonas aeruginosa coliform and Escherichia coli. Staphylococcus aureus which had the highest colony count of 51 before disinfection was reduced to 14 after disinfection. Escherichia coli had the least colony count before and after disinfection. Jik (sodium hydrochlorite) reduced the total bacterial load form 51 to 14 counts.Conclusion: Sodium hypochlorite (Jik) is the most effective disinfectant noticed in our centre.

  • Open Access

    RADIOGRAPHIC DETERMINATION OF NORMAL RANGE VALUES OF ACROMIOCLAVICULAR JOINT SPACE IN NIGERIAN POPULATION

    by Obinna Everistus Abonyi, Julius Amechi Agbo, Sobechukwu W I Onwuzu, Uloma B Nwogu, Emmanuel Arinze Ugwoke, Stephen Olisa Ugwu

    Background: Acromioclavicular joint space is one of the most common injuries of the shoulder region. Accurate diagnosis of most acromioclavicular (AC) joint pathologies depends on the knowledge of the normal range values of acromioclavicular joint space. The variation in the normal AC joint spaces among the studied population points to the need to have population-specific reference range values of acromioclavicular joint space while the paucity of data on normal acromioclavicular joint space diameter in our locality necessitated this study. Objective: This study was, therefore, aimed at radiographically determining the normal reference range values of acromioclavicular joint space diameter with age in adult Nigerian and also to find its variation with sex. Methods: This retrospective study was conducted in three tertiary hospitals in Enugu from January 2019 to July 2019. It involved digital anteroposterior shoulder radiographs of 628 adults (18 – 80 years) obtained using Zanca’s view and reported as normal by four consultant radiologists. The acromioclavicular joint space diameter is calculated as an integral of the distances between the superior and inferior borders of the acromioclavicular joint space. Data were analyzed using a linear regression model, Pearson product-moment correlation coefficient, and independent sample t-test. Results: The mean AC joint space diameter ranged from 3.63 mm at ≤ 20 years to 1.14 mm at 76-80 years of age. Acromioclavicular joint space diameter correlated strongly but negatively with age with correlation coefficients of -0.785, -.839, -.797, and -.780. There was a significant difference between the acromioclavicular joint space diameter of males and females (p = 0.000). Conclusion: This study has generated a reference range value of normal acromioclavicular joint space diameter with age in our locality while there is a difference in acromioclavicular joint space between male and female adult Nigerians.

  • COP27 CLIMATE CHANGE CONFERENCE: URGENT ACTION NEEDED FOR AFRICA AND THE WORLD

    by Lukoye Atwoli, Gregory E Erhabor, Aiah A. Gbakima, Abraham Haileamlak, Jean-Marie Kayembe Ntumba, James Kigera, Laurie Laybourn-Langton, Bob Mash, Joy Muhia, Fhumulani Mavis Mulaudzi, et al.

    Wealthy nations must step up support for Africa and vulnerable countries in addressing past, present and future impacts of climate change

  • THE PRACTICE AND IMPLEMENTATION OF RADIATION MONITORING OF RADIOGRAPHERS IN TERTIARY HOSPITALS IN SOUTHEASTERN NIGERIA: A REASSESSMENT

    by Sobechukwu Onwuzu, Obinna Abonyi, Sunday David, Anthony Ozioko, Chinagorom Umeugochukwu, Vincent Ugwu, Ifunanya Onwuzu

    Background: Radiation monitoring is an essential radiation safety practice that helps to determine the cumulative radiation dose absorbed by radiographers, ensuring that it does not exceed permissible limits. Failure in practice and implementation of radiation monitoring exposes radiographers to stochastic effects of radiation exposure, increasing the hazard radiation workers are exposed to. Objective: To reassess the practice and implementation of radiation monitoring of radiographers working in south-eastern tertiary hospitals in Nigeria. Methods: This was a cross-sectional survey involving 102 radiographers from 5 selected South-Eastern tertiary hospitals. Proportional stratified random sampling was used to select the radiographers from each tertiary hospital while a semi-structured questionnaire in line with the specific objectives was used as the method for data collection. Information obtained from the respondents was related to established radiation monitoring requirements and tables were used for data presentation. Results: With a perfect response rate from the 102 respondents, personnel radiation monitoring was available to only 31% (n = 32) of the respondents with 59% (n = 19) using Thermoluminiscent dosimeters. Even though a majority (71.9%, n=23) wore their dosimeters daily, only half (50%, n = 16) of those monitored had routine device retrieval and feedback of reading at the appropriate time. Employees did not demand radiation monitoring history from the radiographers before employment and only 10% (n = 3) of those monitored claimed they had dosimetry records. Lastly, only 6.3% (n = 2) of radiographers have been on leave as a direct result of over-exposure to radiation. Conclusion: Personnel radiation monitoring practices of radiographers in South-Eastern tertiary hospitals still remain below internationally acceptable standards. Comparing the findings of this study with a similar study carried out 10 years ago, there has been little improvement in the radiation monitoring of radiographers. The management of tertiary health institutions should ensure that personnel monitoring devices are made available to radiographers, and stricter rules should be placed on the daily wearing of dosimeters.


  • REJECT-REPEAT ANALYSIS OF RADIOGRAPHS IN DIGITAL COMPUTED RADIOGRAPHY (CR) UNIVERSITY OF ABUJA TEACHING HOSPITAL, NIGERIA.

    by Nemi Joshua, Mohammed Sidi, Isaac Udugh

    Background: Repeat-Reject Analysis (RRA) is a quality indicator and a critical tool for dose and image quality optimization in Radiology Departments. Aim: This study was aimed at evaluating the reject-repeat analysis of radiographs in digital computed radiography (CR) at the University of Abuja Teaching Hospital, Nigeria. Materials and Methods: The study was a prospective, cross-sectional design. The study was conducted at the Department of Radiology, University of Abuja st st Teaching Hospital (UATH), Gwagwalada, from 1 September 2020 to 31 March 2021. All the rejected-repeated images were used during the study period; 377 images were rejected. An adapted data capture sheet was used from the quality assurance workbook for Radiographers and Radiological Technologists. The obtained data was analyzed using micro soft excel and statistical package for social sciences (SPSS) version 22.0. Result: Out of the total of 1362 images that were acquired during the study period, 377 images were rejected. The overall repeat-reject rate was 27.67%. The highest examination was the chest 560 (41.375), followed by lower extremities 41 (10.87%). The lowest examinations were the paranasal sinuses 1 (0.26%) and Thoracic spine 2 (0.52%). The pelvic/hips had the highest repeat-reject rate 28 (52.82%), followed by the lumbosacral spine 29 (49.15%) and then post-nasal space 16 (47.05%) respectively. Conclusion: In this study, the overall repeat-reject rate was higher than the acceptable limit. The chest has the highest number of examinations. The pelvic/hips had the highest repeat-reject rate, followed by the lumbosacral spine and post-nasal space respectively.


  • IMPACT OF ULTRASOUND AND SOCIODEMOGRAPHIC VARIABLES ON MATERNAL FOETAL ATTACHMENT IN TARABA STATE, NIGERIA

    by A Yakubu

    Background: Maternal foetal attachment is manifested in behaviours that demonstrate care and commitment to the foetus. Ultrasound decreases maternal anxiety and confers psychological benefits following a reassuring sonogram. Maternal-foetal attachment is affected by many socio-demographic factors which include maternal age, occupation, educational level, race, marriage duration, ethnicity, Religion, income status, pregnancy planning, and identification of the foetal gender Aim: This study was aimed at assessing the effect of ultrasound and sociodemographic factors on maternal foetal attachment during pregnancy. Method: A prospective study was conducted from November 2019 to March 2020. A convenient sampling method was employed and included 404 pregnant women aged 18-45 years old in their 2nd and 3rd trimesters. The data were collected using a maternal foetal attachment scale questionnaire. Descriptive and inferential statistics were carried out at a p-value < 0.05. Result: The score of the maternal foetal attachment scale was greater with post ultrasound than the pre ultrasound. There was a statistically significant difference between the pre and post ultrasound maternal foetal attachment scale (p=0.000). A statistically significant difference was observed in the maternal foetal attachment across the different ethnic groups (p=0.000), planned and unplanned pregnancy (p=0.000). Conclusion: This study revealed that ultrasound scan has an influence on maternal foetal attachment, planned pregnancy. Hausa, Bandawa and Jenjo were found to be more attached to their foetuses.

  • THE RACE TOWARDS THE UNIVERSAL HEALTH COVERAGE AND FACTORS INFLUENCING RADIOGRAPHERS CAREER CHOICE IN RURAL SETTLEMENTS IN NORTH-EASTERN NIGERIA

    by Geofery Luntsi

    Background: There is a human resource crisis in the healthcare sector in Nigeria. This is because of the existing inequitable distribution of the available meagre workforce which is itself not helped by the increasing and currently trending brain drain. Purpose: This study aimed at assessing the factors that influence radiographers choice of career in rural settlements in Northeastern Nigeria. Methods: A cross-sectional study was conducted among Radiographers in Northeastern Nigeria. A 21-item, self-administered semi-structured questionnaire was distributed over a six (6) month period, where 130 questionnaires were distributed. The questionnaire consisted of two sections; a: on demography; b: on factors (attractors and detractors) for career choice in rural areas. Content analysis was used to analyze qualitative data; descriptive statistics were used to analyze quantitative data. Statistical Package for Social Sciences (SPSS) version 21.0 was used. Results: A total of 91 questionnaires were retrieved, giving a response rate of 70%. There were 56 (61.5%) males and 35 (38.5%) females. About 82 (90.1 %) had B.Sc and 9 (9.9 %) had M.Sc as their highest qualification. The major attractors for accepting rural jobs were improved remuneration 97 (86.8%) and opportunity for continuous professional development 72 (79.1%). While major detractors were, the cultural and traditional beliefs of the people in rural areas 23 (25.3%) and the lack of social amenities/poor infrastructure 22 (24.2%). Conclusion: The attractors for radiographers to rural areas in this study were; improved remuneration, availability of equipment, professional development, availability of social amenities and security among others. To recruit and retain radiographers in the rural areas, government, recruitment agencies and employers should in addition to good remuneration motivate the radiographers by providing adequate power, security, rural posting allowances, good functional equipment and a working and learning environment.


  • RADIOLOGICAL EVALUATION OF LEAD APRON INTEGRITY IN FIVE SELECTED HOSPITALS IN ABUJA, NIGERIA

    by Ibrahim Ilupeju

    Background: The general consensus is that any exposure to ionising radiation carries a risk. Diagnostic radiology is the largest (87%) contributor to man-made ionising radiation, therefore any economical and socially acceptable means of reducing dose without compromising the diagnostic value of the procedure must be worth implementing. Aim: This study is aimed at evaluating lead apron integrity in five selected Hospitals in Abuja, Nigeria. Methodology: The methodology approach includes the application of a large area beam for transmission measurement with the placement of OSLD before and behind the ten (10) lead aprons to determine the entrance and exit dose as well as the transmission factor. In this study, a lead apron consisting of 0.25mm and 0.35mm thickness were examined. Results: The result shows that the transmittance factor of the entrance and exit dose through the lead equivalent aprons is directly proportional to the age of the apron with NHA1 having the highest transmission factor (0.83) and oldest age (16 years). WGH2 has the lowest transfer factor (0.12) and the least age (1 year). Conclusion: Lead aprons loses their attenuation capability over time and should be replaced after 15 years at most for effective protection against ionizing radiation.