Modelling in Civil Environmental Engineering
Published by Walter de Gruyter GmbH
- Scilit
- DOAJ
- Thermodynamics
- Concrete
- Climate Change
- Energy Systems & Technologies
- Reliability Engineering
- Numerical Methods
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 3
- Total Publications
- 12
- Average Citations
- 0.25
- Cited Publications
- 2
- Cited Publications %
- 16.7%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 3
- Monthly Citation Metric (MCM)
- 0.21
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 2.9
- Max
- 3
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-15
Comparison Between Machine Learning Predictions and Eurocode 8 Empirical Expressions for the Plastic Rotation Capacity of Rectangular Rc Columns
This paper presents a comparative assessment of the plastic rotation capacity of rectangular reinforced concrete columns, using machine learning predictions and the empirical expressions provided by Eurocode 8, Part 3. The study relies on a database of 258 rectangular RC column specimens subjected to quasi-static cyclic lateral loading, covering a wide range of reinforcement configurations, axial load levels, shear span-to-depth ratios and failure modes. A previously developed and validated Stacking Ensemble model, combining Support Vector Regression, Random Forest and XGBoost through a RidgeCV meta-regressor, is used as the data-driven reference model. Its predictions are compared with the values obtained using expressions A.3 and A.4 from EN 1998-3:2005, evaluated on a subset of 52 rectangular specimens for which all parameters required by the code expressions were available. The comparison is performed in terms of the coefficient of determination, mean absolute error and root mean squared error, together with a residual error analysis. The results show that the Stacking Ensemble model provides a closer agreement with the experimental values, while the code-based expressions exhibit larger dispersion and a more conservative response, particularly when the partial safety factor is considered. The findings indicate that data-driven models can complement empirical code provisions by providing an additional quantitative reference for the seismic assessment of existing rectangular RC columns.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-15
Open AccessComparison Between Machine Learning Predictions and Eurocode 8 Empirical Expressions for the Plastic Rotation Capacity of Rectangular Rc Columns
This paper presents a comparative assessment of the plastic rotation capacity of rectangular reinforced concrete columns, using machine learning predictions and the empirical expressions provided by Eurocode 8, Part 3. The study relies on a database of 258 rectangular RC column specimens subjected to quasi-static cyclic lateral loading, covering a wide range of reinforcement configurations, axial load levels, shear span-to-depth ratios and failure modes. A previously developed and validated Stacking Ensemble model, combining Support Vector Regression, Random Forest and XGBoost through a RidgeCV meta-regressor, is used as the data-driven reference model. Its predictions are compared with the values obtained using expressions A.3 and A.4 from EN 1998-3:2005, evaluated on a subset of 52 rectangular specimens for which all parameters required by the code expressions were available. The comparison is performed in terms of the coefficient of determination, mean absolute error and root mean squared error, together with a residual error analysis. The results show that the Stacking Ensemble model provides a closer agreement with the experimental values, while the code-based expressions exhibit larger dispersion and a more conservative response, particularly when the partial safety factor is considered. The findings indicate that data-driven models can complement empirical code provisions by providing an additional quantitative reference for the seismic assessment of existing rectangular RC columns.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-25
Network Analysis of Water Distribution System in Urban Areas Using EPANET 2.2 Software
This study evaluates the hydraulic performance of the water distribution network of the Municipality of Oradea, Romania, using EPANET 2.2. A hydraulic model consisting of 270 pipes, 260 junction nodes, pumping stations, and storage reservoirs was developed to assess the operational behavior of the network. Two hydraulic simulation approaches were applied: Demand Driven Analysis (DDA) and Pressure Driven Analysis (PDA). The comparison between these approaches aimed to investigate the influence of pressure-dependent demand on network performance and to determine the suitability of each method for hydraulic assessment. The hydraulic performance of the system was evaluated using key indicators including nodal pressure, pipe flow velocity, pressure reliability, and demand satisfaction. The simulation results showed that the network generally operates within acceptable hydraulic limits. Pressure values remained sufficient to satisfy consumer demands, while pipe flow velocities were found to be consistent with the recommendations of European standard EN 805 and Romanian standard NP 133-2022. The comparative analysis demonstrated that Pressure Driven Analysis (PDA) provides a more realistic representation of network behavior under variable pressure conditions by accounting for pressure-dependent demand variations. The results confirm the applicability of EPANET 2.2 as an effective tool for simulating hydraulic systems and demonstrate the advantages of PDA for evaluating the operational performance of urban water distribution systems under realistic operating conditions.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-25
Open AccessNetwork Analysis of Water Distribution System in Urban Areas Using EPANET 2.2 Software
This study evaluates the hydraulic performance of the water distribution network of the Municipality of Oradea, Romania, using EPANET 2.2. A hydraulic model consisting of 270 pipes, 260 junction nodes, pumping stations, and storage reservoirs was developed to assess the operational behavior of the network. Two hydraulic simulation approaches were applied: Demand Driven Analysis (DDA) and Pressure Driven Analysis (PDA). The comparison between these approaches aimed to investigate the influence of pressure-dependent demand on network performance and to determine the suitability of each method for hydraulic assessment. The hydraulic performance of the system was evaluated using key indicators including nodal pressure, pipe flow velocity, pressure reliability, and demand satisfaction. The simulation results showed that the network generally operates within acceptable hydraulic limits. Pressure values remained sufficient to satisfy consumer demands, while pipe flow velocities were found to be consistent with the recommendations of European standard EN 805 and Romanian standard NP 133-2022. The comparative analysis demonstrated that Pressure Driven Analysis (PDA) provides a more realistic representation of network behavior under variable pressure conditions by accounting for pressure-dependent demand variations. The results confirm the applicability of EPANET 2.2 as an effective tool for simulating hydraulic systems and demonstrate the advantages of PDA for evaluating the operational performance of urban water distribution systems under realistic operating conditions.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-19
A GIS-Assisted Python Toolchain for Location-Based Environmental Parameter Retrieval and Load Computation Based on Romanian Codes
Structural engineering design in Romania relies on location-dependent environmental parameters and zonation maps for snow, wind, seismicity, and frost depth. Manual reading of zonation maps is time-consuming, error-prone near zone boundaries, and difficult to reproduce at scale. This paper presents a GIS-assisted Python toolchain that retrieves site parameters directly from georeferenced national layers and unified composite KML overlays, computes snow and wind actions for multiple roof typologies according to CR 1-1-3/2012 and CR 1-1-4/2012 and supplies seismic parameters (peak ground acceleration - ag and response spectra control period - T C ) per P100-1/2013 and frost depth per STAS 6054/77. The workflow integrates updated baseline maps from the CCERS collection, population density and tree cover density for the classification of the snow exposure and terrain conditions, while the frost-depth map is reconstructed in QGIS according to STAS. A second version of each map was created based on the MDLPA official seismic map creation approach for uniform administrative reporting. Two composite overlap maps were also produced to visually validate multi-factor assignments and support transparent, repeatable site characterization. Case studies across Romania demonstrate consistent parameter retrieval for both point coordinates and administrative level aggregation, enabling fast reporting and automated batch evaluations suitable for design offices and research pipelines.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-19
Open AccessA GIS-Assisted Python Toolchain for Location-Based Environmental Parameter Retrieval and Load Computation Based on Romanian Codes
Structural engineering design in Romania relies on location-dependent environmental parameters and zonation maps for snow, wind, seismicity, and frost depth. Manual reading of zonation maps is time-consuming, error-prone near zone boundaries, and difficult to reproduce at scale. This paper presents a GIS-assisted Python toolchain that retrieves site parameters directly from georeferenced national layers and unified composite KML overlays, computes snow and wind actions for multiple roof typologies according to CR 1-1-3/2012 and CR 1-1-4/2012 and supplies seismic parameters (peak ground acceleration - ag and response spectra control period - T C ) per P100-1/2013 and frost depth per STAS 6054/77. The workflow integrates updated baseline maps from the CCERS collection, population density and tree cover density for the classification of the snow exposure and terrain conditions, while the frost-depth map is reconstructed in QGIS according to STAS. A second version of each map was created based on the MDLPA official seismic map creation approach for uniform administrative reporting. Two composite overlap maps were also produced to visually validate multi-factor assignments and support transparent, repeatable site characterization. Case studies across Romania demonstrate consistent parameter retrieval for both point coordinates and administrative level aggregation, enabling fast reporting and automated batch evaluations suitable for design offices and research pipelines.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-8
Bifacial Photovoltaic Module Research Experiment. Part 1: Design and Construction
The present study concerns the construction of a bifacial photovoltaic module research experiment in Bucharest, as well as the reporting of the first monitoring results. This paper presents a comparative study of monofacial and bifacial photovoltaic (PV) modules, with a focus on the role of the reflective surface materials (albedo) in enhancing the backside irradiance and overall system performance. The research was conducted at the Technical University of Construction Bucharest (UTCB) and combines numerical simulations performed with Dialux Evo and PV Sol with real experimental measurements. The results demonstrate that bifacial panels outperform conventional monofacial panels under diffuse irradiance conditions, with energy gains of up to 34% on certain measurement days and a cumulative monthly surplus of 4.43%. The study also addresses critical installation parameters, such as tilt angle, mounting height and selection of reflective surface materials, providing practical guidelines for integrating bifacial systems into passive and energy-efficient buildings.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-8
Open AccessBifacial Photovoltaic Module Research Experiment. Part 1: Design and Construction
The present study concerns the construction of a bifacial photovoltaic module research experiment in Bucharest, as well as the reporting of the first monitoring results. This paper presents a comparative study of monofacial and bifacial photovoltaic (PV) modules, with a focus on the role of the reflective surface materials (albedo) in enhancing the backside irradiance and overall system performance. The research was conducted at the Technical University of Construction Bucharest (UTCB) and combines numerical simulations performed with Dialux Evo and PV Sol with real experimental measurements. The results demonstrate that bifacial panels outperform conventional monofacial panels under diffuse irradiance conditions, with energy gains of up to 34% on certain measurement days and a cumulative monthly surplus of 4.43%. The study also addresses critical installation parameters, such as tilt angle, mounting height and selection of reflective surface materials, providing practical guidelines for integrating bifacial systems into passive and energy-efficient buildings.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-12
Study on the Influence of Coupling Beam Depth for Coupled Shear Wall Systems
The geometrical dimensions of coupling beams can strongly alter the overall behavior of coupled shear walls systems. This study examines the differences in structural response of two reinforced concrete coupled shear walls systems with different coupling beam depths. Nonlinear static pushover analysis was conducted on both models, carried out up to a target overall rotation of 2%. The results are compared in terms of peak lateral force, energy dissipation and strength degradation. The deeper beam system proved stiffer and able to dissipate more energy than its counterpart. The shallower beam system offered greater deformation capacity. An important finding is represented by the shift of the strength degradation mechanism: the strong coupling effect generated by the deep coupling beams led to the eventual crushing of concrete in the compressed pier, while the shallower beams began to yield, causing a degradation of the overall coupling moment.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-12
Open AccessStudy on the Influence of Coupling Beam Depth for Coupled Shear Wall Systems
The geometrical dimensions of coupling beams can strongly alter the overall behavior of coupled shear walls systems. This study examines the differences in structural response of two reinforced concrete coupled shear walls systems with different coupling beam depths. Nonlinear static pushover analysis was conducted on both models, carried out up to a target overall rotation of 2%. The results are compared in terms of peak lateral force, energy dissipation and strength degradation. The deeper beam system proved stiffer and able to dissipate more energy than its counterpart. The shallower beam system offered greater deformation capacity. An important finding is represented by the shift of the strength degradation mechanism: the strong coupling effect generated by the deep coupling beams led to the eventual crushing of concrete in the compressed pier, while the shallower beams began to yield, causing a degradation of the overall coupling moment.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-26
Compression and Bending Resistance of Steel Members: A Comparative Study on EN 1993-1-1 and AISC 360-22 Provisions
This paper presents a comparative study of provisions in two widely used design standards for structural steel members: the European standard EN 1993-1-1 (Eurocode 3) [9] and the American standard AISC 360-22[10]. The research concentrates on the verification of steel members subjected to combined axial compression and bending -frequently encountered in buildings, bridges, and industrial structures. In the beginning, this paper briefly compares the relations in both standards to identify key similarities and differences in terms of verification formulae, safety factors, and underlying design assumptions. A focus is placed on the influence of member slenderness, as the study considers columns across a range of slenderness ratios to assess how each standard responds to varying levels of slenderness. Furthermore, the main body of the research investigates in detail the resistance predictions of both standards through a structured parametric analysis. The study considers three representative cases of moment diagrams along the bar: uniform bending, linearly varying moment, and opposite end moments, each examined across a range of member slenderness ratios. Results are presented graphically in a structured and sequential manner, to facilitate interpretation and to highlight cases where the two standards yield possible significantly different resistance capacities. The comparative study shows that differences between EN 1993-1-1[9] and AISC 360-22[10] can be noticed in the member and the combination of applied loads.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-26
Open AccessCompression and Bending Resistance of Steel Members: A Comparative Study on EN 1993-1-1 and AISC 360-22 Provisions
This paper presents a comparative study of provisions in two widely used design standards for structural steel members: the European standard EN 1993-1-1 (Eurocode 3) [9] and the American standard AISC 360-22[10]. The research concentrates on the verification of steel members subjected to combined axial compression and bending -frequently encountered in buildings, bridges, and industrial structures. In the beginning, this paper briefly compares the relations in both standards to identify key similarities and differences in terms of verification formulae, safety factors, and underlying design assumptions. A focus is placed on the influence of member slenderness, as the study considers columns across a range of slenderness ratios to assess how each standard responds to varying levels of slenderness. Furthermore, the main body of the research investigates in detail the resistance predictions of both standards through a structured parametric analysis. The study considers three representative cases of moment diagrams along the bar: uniform bending, linearly varying moment, and opposite end moments, each examined across a range of member slenderness ratios. Results are presented graphically in a structured and sequential manner, to facilitate interpretation and to highlight cases where the two standards yield possible significantly different resistance capacities. The comparative study shows that differences between EN 1993-1-1[9] and AISC 360-22[10] can be noticed in the member and the combination of applied loads.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-15
Modelling of a RC Shear Wall Experiment Using Shell Layered Finite Elements
This paper presents the numerical modelling strategy used to recreate a shear wall experiment, in the finite element analysis software ETABS using shell layered elements. The experiment, conducted by Oh et al ., subjected four different wall specimens to cyclic lateral loading to determine the effect of transversal reinforcement on their deformation capacity[1]. The experimental results, extracted from the SERIES database [2] for the WR-10 and WR-20 specimens are used as the basis for model validation. The finite element model employs a two-layer shell section, with separate reinforcement and concrete membrane layers, while the cyclic loading protocol is recreated through a series of chained nonlinear static displacement-controlled load cases. The results are compared with the experimental data, in terms of peak lateral force, cumulative energy dissipation and hysteresis loop shape.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-15
Open AccessModelling of a RC Shear Wall Experiment Using Shell Layered Finite Elements
This paper presents the numerical modelling strategy used to recreate a shear wall experiment, in the finite element analysis software ETABS using shell layered elements. The experiment, conducted by Oh et al ., subjected four different wall specimens to cyclic lateral loading to determine the effect of transversal reinforcement on their deformation capacity[1]. The experimental results, extracted from the SERIES database [2] for the WR-10 and WR-20 specimens are used as the basis for model validation. The finite element model employs a two-layer shell section, with separate reinforcement and concrete membrane layers, while the cyclic loading protocol is recreated through a series of chained nonlinear static displacement-controlled load cases. The results are compared with the experimental data, in terms of peak lateral force, cumulative energy dissipation and hysteresis loop shape.
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-14
Advancing Indoor Air Quality Management Through Predictive Feedforward Control - A Comparative Analysis
In the contemporary built environment, ensuring optimal Indoor Air Quality (IAQ) while maintaining energy efficiency represents a multifaceted challenge for building management systems (BMS). Traditional ventilation strategies are predominantly reactive, adjusting air exchange rates only after pollutant concentrations exceed established safety thresholds. This reactive latency, or “phase lag,” often results in temporary exposure to high pollutant levels and suboptimal energy utilization. This study proposes a proactive “feed-forward” control framework based on pollutant forecasting. We conduct a rigorous comparative analysis of three distinct modeling paradigms: Long Short-Term Memory (LSTM) neural networks, Random Forest (RF) ensembles, and Autoregressive Integrated Moving Average (ARIMA) models. The models were trained and validated using a comprehensive 1-year office environmental dataset from Kaggle, encompassing CO 2 , PM 2.5 temperature, and humidity. Our findings demonstrate that for CO 2 forecasting, both LSTM and RF architectures achieve high predictive accuracy (R 2 > 0.97) and successfully eliminate the reactive phase lag. For PM 2.5 , the stochastic nature of indoor particulate events presents a significant challenge, with the LSTM exhibiting a “conservative smoothing” effect and occasional mathematical artifacts such as negative values.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-14
Open AccessAdvancing Indoor Air Quality Management Through Predictive Feedforward Control - A Comparative Analysis
In the contemporary built environment, ensuring optimal Indoor Air Quality (IAQ) while maintaining energy efficiency represents a multifaceted challenge for building management systems (BMS). Traditional ventilation strategies are predominantly reactive, adjusting air exchange rates only after pollutant concentrations exceed established safety thresholds. This reactive latency, or “phase lag,” often results in temporary exposure to high pollutant levels and suboptimal energy utilization. This study proposes a proactive “feed-forward” control framework based on pollutant forecasting. We conduct a rigorous comparative analysis of three distinct modeling paradigms: Long Short-Term Memory (LSTM) neural networks, Random Forest (RF) ensembles, and Autoregressive Integrated Moving Average (ARIMA) models. The models were trained and validated using a comprehensive 1-year office environmental dataset from Kaggle, encompassing CO 2 , PM 2.5 temperature, and humidity. Our findings demonstrate that for CO 2 forecasting, both LSTM and RF architectures achieve high predictive accuracy (R 2 > 0.97) and successfully eliminate the reactive phase lag. For PM 2.5 , the stochastic nature of indoor particulate events presents a significant challenge, with the LSTM exhibiting a “conservative smoothing” effect and occasional mathematical artifacts such as negative values.
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-9
The Relationship Between Indoor Classroom Noise Levels and the Operating State of the Ventilation System
The evolution of the outdoor climate, combined with the quality requirements imposed on educational environments, leads to special scenarios that are not currently covered by existing noise protection standards. In this study, we present an acoustic analysis of such a scenario, where a noise-generating ventilation unit is installed inside a classroom. In-situ measurements of both sound pressure levels and overall A-weighted sound pressure levels were conducted within the classroom across various operating states of the ventilation equipment. Regardless of the operating mode, the measured noise level remained below the acoustic comfort limit. A low variation in noise levels was observed throughout the interior of the classroom. Slightly higher values were recorded near the noise source, whereas lower values were observed in the corner opposite the equipment. Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-9
Open AccessThe Relationship Between Indoor Classroom Noise Levels and the Operating State of the Ventilation System
The evolution of the outdoor climate, combined with the quality requirements imposed on educational environments, leads to special scenarios that are not currently covered by existing noise protection standards. In this study, we present an acoustic analysis of such a scenario, where a noise-generating ventilation unit is installed inside a classroom. In-situ measurements of both sound pressure levels and overall A-weighted sound pressure levels were conducted within the classroom across various operating states of the ventilation equipment. Regardless of the operating mode, the measured noise level remained below the acoustic comfort limit. A low variation in noise levels was observed throughout the interior of the classroom. Slightly higher values were recorded near the noise source, whereas lower values were observed in the corner opposite the equipment. Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
- Open Access
- 1 September 2025
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 20 (3) , 21-40
Parametric Investigation of Thermal Performance in Energy Piles and the Influence of Pile Spacing
Experimental investigation of the effects of various parameters and pile spacing on the thermal performance of energy piles is not practical in terms of cost and time. Therefore, numerical modeling studies are becoming increasingly important in such topics. In this thesis, a numerical modeling study was conducted to examine the effects of heat exchanger pipe diameter, number, position within the pile, and pile diameter, as well as the number of piles and the spacing between them, on the thermal performance of energy piles.
- 1 September 2025
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 20 (3) , 21-40
Open AccessParametric Investigation of Thermal Performance in Energy Piles and the Influence of Pile Spacing
Experimental investigation of the effects of various parameters and pile spacing on the thermal performance of energy piles is not practical in terms of cost and time. Therefore, numerical modeling studies are becoming increasingly important in such topics. In this thesis, a numerical modeling study was conducted to examine the effects of heat exchanger pipe diameter, number, position within the pile, and pile diameter, as well as the number of piles and the spacing between them, on the thermal performance of energy piles.