Journal Geuthee of Engineering and Energy (JOGE)

Published by Geuthee Institute

Abbrev: J. Geuthee Eng. Energy (JOGE)
EISSN 2964-2655
Database Coverage
  • Scilit
  • DOAJ
Journal Articles
All-time journal articles
47
2025 journal articles
10
Subject
  • Power Systems & Electric Vehicles
  • Energy Systems & Technologies
  • AI & Machine Learning
  • Electrical Safety
  • Control & Automation Engineering
  • Electrical Energy Management

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Power Systems & Electric Vehicles
20
Energy Systems & Technologies
13
AI & Machine Learning
6
Electrical Energy Management
6
Electrical Safety
5
Software Design
5
Computer Vision & Graphics
3
Control & Automation Engineering
3
Thermodynamics
2
Wireless Technology
2

Top Countries

Publications in 2016-2026.

CountryPublications
Indonesia
28

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
8
Total Publications
22
Average Citations
0.36
Cited Publications
5
Cited Publications %
22.7%
Self Citations
0
Self Citations %
0%

Metrics
h5_index
3
Monthly Citation Metric (MCM)
0.24

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
1
99%
4.4
Max
5

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Arduino based mini scada for power distribution system relay control

    by Habib Muharry Yusdartono, Andik Bintoro, Dahlan Abdullah, Badriana Badriana, Fitria Priyulida

    This study aims to develop a mini SCADA system as a simpler and more affordable alternative solution for educational and research purposes, especially in the control of relays in distribution system modules. Design and implement of a mini SCADA prototype are able to control the relay in real-time while evaluating the performance of the system in terms of response speed, control accuracy, and operational reliability. The research adopts both quantitative and qualitative approach with laboratory experiment methods at Malikussaleh University, utilizing Arduino Uno, PZEM-004T sensors, relay modules, and LabVIEW software integration for monitoring and controlling. The test results showed that the system successfully monitored electrical parameters (voltage, current, power, and frequency) with a good level of sensor accuracy (error ≤0.03%), and was able to activate automatic protection against under/over voltage and over current conditions with a fast response according to the set limit. These findings confirm that mini SCADA is not only feasible as a means of practical learning, but also has the potential to be an early model for the implementation of small-scale distribution control such as microgrids. In addition, this study provides empirical evidence that simple hardware integration with open-source software can result in efficient and applicable control systems. In conclusion, this study makes a significant contribution to expanding the understanding of SCADA integration with distribution relays, while opening up further research opportunities related to system communication optimization to reduce response delays and improve operational resilience in the future..This study aims to develop a mini SCADA system as a simpler and more affordable alternative solution for educational and research purposes, especially in the control of relays in distribution system modules. Design and implement of a mini SCADA prototype are able to control the relay in real-time while evaluating the performance of the system in terms of response speed, control accuracy, and operational reliability. The research adopts both quantitative and qualitative approach with laboratory experiment methods at Malikussaleh University, utilizing Arduino Uno, PZEM-004T sensors, relay modules, and LabVIEW software integration for monitoring and controlling. The test results showed that the system successfully monitored electrical parameters (voltage, current, power, and frequency) with a good level of sensor accuracy (error ≤0.03%), and was able to activate automatic protection against under/over voltage and over current conditions with a fast response according to the set limit. These findings confirm that mini SCADA is not only feasible as a means of practical learning, but also has the potential to be an early model for the implementation of small-scale distribution control such as microgrids. In addition, this study provides empirical evidence that simple hardware integration with open-source software can result in efficient and applicable control systems. In conclusion, this study makes a significant contribution to expanding the understanding of SCADA integration with distribution relays, while opening up further research opportunities related to system communication optimization to reduce response delays and improve operational resilience in the future.

  • Open Access

    Application of fourier transform for early detection of bearing failures in electric motors

    by Giovanni Dimas Prenata, Muhammad Alif Sofi Syariffudin, Reza Sarwo Widagdo

    This study presents an analysis of bearing fault conditions in electric motors through stator current measurements and their transformation into the frequency domain. Measurements were conducted under two main bearing conditions: normal and damaged, each tested with three load variations (no load, generator load, and generator load with one lamp). The time-domain current waveforms showed minimal visual distinction between normal and damaged bearing conditions, making classification difficult. Therefore, the current data were transformed into the frequency domain using the Discrete Fourier Transform (DFT). The frequency domain analysis revealed that in normal bearing conditions, the frequency magnitude distribution was relatively stable and symmetrical, with low fluctuation in the frequency index range k = 0 to k = 10. In contrast, damaged bearing conditions exhibited larger and irregular fluctuations in frequency magnitude across different load levels, indicating a distinct signature of bearing failure. Consequently, frequency domain analysis proves to be an effective approach for detecting bearing faults based on the spectral characteristics of motor current signals.

  • Open Access

    Impact of distributed generation on power losses and voltage profile of the Unsyiah distribution feeder

    by Ramdhan Halid Siregar, Muhammad Hirzan Mardhika, H Hafidh

    Distributed generation (DG) ha s emerged as an effective solution for improving power quality, enhancing voltage profiles, and reducing power losses in electrical distribution systems. This study investigates the impact of renewable-energy-based DG integration on the voltage profile and power losses of the Unsyiah distribution feeder in Banda Aceh, Indonesia. The distribution network was modeled and analyzed using ETAP 16.0.2, while MATLAB R2021a with the backpropagation artificial neural network (ANN) method was employed to estimate solar radiation intensity and wind speed data for photovoltaic (PV) and wind power plant (WPP) generation. The ANN model was trained using environmental and climate data, producing regression values of 0.84901 for solar radiation prediction and 0.85083 for wind speed prediction, indicating satisfactory predictive performance. Two DG placement scenarios with a penetration level of 20% of the total feeder load (388.4 kW) were evaluated at Bus USK 01 and Bus USK 24. Simulation results demonstrate that DG integration significantly improves the voltage profile, particularly at buses located near the end of the feeder where voltage drops are more severe. The optimal scenario was achieved by placing wind-power-based DG at Bus USK 24, which reduced active power losses from 11.8 kW to 8.1 kW and reactive power losses from 13.1 kVAR to 8.6 kVAR. Overall, the integration reduced active power losses by 31.35% and reactive power losses by 34.35%. The findings confirm that both DG placement location and DG type strongly influence the effectiveness of voltage profile enhancement and power loss reduction in radial distribution systems.

  • Open Access

    Short circuit current limitation using series reactors in 20 kV distribution feeder

    by Ramdhan Halid Siregar, Alwan Farras, S Syahrizal

    Short-circuit faults in power distribution systems generate excessive fault currents that can damage electrical equipment and reduce system reliability. One practical method for limiting fault current is the installation of a series reactor or current limiting reactor (CLR). This study analyzes short-circuit current characteristics in the 20 kV Ulee Kareng distribution feeder in Banda Aceh and evaluates the effectiveness of a series reactor in reducing fault current levels. The analysis was performed using ETAP 19.0.1 simulation software based on the IEC 60909 standard. Four fault types were investigated: three-phase, single line-to-ground, line-to-line, and double line-to-ground faults. The simulation results show that the maximum three-phase short-circuit current before reactor installation was 4.066 kA at bus LBU 01-00, while the minimum value was 2.732 kA at bus LBU 42-00. A series reactor with a reactance value of 3.12 Ω was designed to achieve approximately 50% current reduction. After installation, the three-phase short-circuit current at bus LBU 01-00 decreased to 2.103 kA, corresponding to a 48% reduction. The results confirm that the series reactor effectively reduces fault current levels and improves protection system performance without replacing existing circuit breakers. The novelty of this study lies in the evaluation of series reactor performance for all fault types in the actual 20 kV Ulee Kareng distribution feeder using IEC 60909-based ETAP simulations under real operating conditions

  • Open Access

    Predicting sleep quality using random forest on sleep health and lifestyle data

    by Naia Az - Zahra, Deri Latika Herda

    Sleep is an important physiological process that plays a role in maintaining the balance of biological and psychological functions. Lifestyle changes, such as high stress levels and a lack of physical activity, can affect a person’s sleep quality. This study aims to analyze the influence of health and lifestyle factors on sleep quality and to develop a predictive model for sleep quality using the Random Forest algorithm. This study uses the Sleep Health and Lifestyle dataset with a classification approach into two categories, namely Ideal Sleep and Non-Ideal Sleep, determined based on sleep duration parameters referring to the concept of a U-shaped relationship and the sleep duration recommendations from the National Sleep Foundation. The data were processed through preprocessing and class imbalance handling using the SMOTE method, then split into training and testing data. The Random Forest model was built through hyperparameter tuning and evaluated using accuracy and Area Under the Curve (AUC) metrics. The results show that the Random Forest model achieved good classification performance with an Accuracy of 91.26%, Precision of 91.78%, Recall of 91.26%, and F1-Score of 91.30%. In addition, the model obtained an Area Under the Curve (AUC) value of 0.962, indicating very good classification capability. Based on the Feature Importance analysis results, the features with the greatest influence on sleep quality are Heart Rate, Stress Level, Physical Activity, and Daily Steps. The findings indicate that the combination of the SMOTE method and Random Forest is effective for predicting sleep quality based on health and lifestyle factors.

  • Open Access

    Circular microstrip antenna with defected ground structure for bandwidth enhancement at 2.4 GHz

    by Muhammad Nur Fadly, Deri Latika Herda, Popy Maria

    This study proposes an optimized circular microstrip patch antenna integrated with a stepped-slot Defected Ground Structure (DGS) for 2.4 GHz WLAN applications. The objective of this work is to improve the bandwidth and gain performance of conventional microstrip antennas, which are typically limited by narrow bandwidth and low radiation efficiency. The main contribution of this study is the development of a novel stepped-slot DGS configuration combined with a circular patch geometry to achieve simultaneous enhancement of bandwidth and gain. The proposed antenna is designed on an FR-4 substrate with a dielectric constant of 4.3 and a thickness of 1.6 mm, and analyzed using CST Microwave Studio. A parametric optimization of the DGS dimensions is performed to obtain optimal antenna performance. Simulation results show that the bandwidth increases significantly from 70.4 MHz to 298.8 MHz, representing more than a fourfold improvement. In addition, the antenna gain improves from 2.72 dBi to 3.87 dBi after the implementation of the DGS structure. These results confirm that the proposed stepped-slot DGS effectively enhances impedance bandwidth and radiation performance without increasing antenna complexity. Therefore, the proposed antenna is suitable for practical WLAN applications requiring compact size and improved performance. The findings of this study also provide useful insights for the design of high-performance microstrip antennas using DGS techniques in future wireless communication systems.


  • Open Access

    AIS-based vessel monitoring system using software defined radio

    by M. Aqsha Aqrizal, Ummul Khair, Ratna Dewi

    This study implements a low-cost Software Defined Radio (SDR)-based receiver system for the Automatic Identification System (AIS) operating at frequencies of 161.975 MHz and 162.025 MHz using a 44 cm V-dipole antenna with a 90° angle. Spectrum analysis is performed using Airspy to identify AIS signal characteristics in real time within the frequency domain, with measured Signal-to-Noise Ratio (SNR) values of 21.3 dB for AIS 1 and 21.4 dB for AIS 2. The signal decoding process is carried out by AIS-catcher, which handles GMSK demodulation and efficiently extracts AIS message payloads. The decoded data is then visualized using OpenCPN in the form of a digital map to monitor vessel positions and movements in real time. SDRangel is utilized as a supporting platform for signal observation, SDR device configuration, and additional analysis of reception quality. System performance evaluation demonstrates stable capability in receiving and decoding AIS signals with a satisfactory success rate, although it is still affected by interference and propagation conditions. GNU Radio is used in a limited capacity as a signal processing environment for filtering and basic parameter adjustment. The results confirm that low-cost SDR is an effective, flexible, and economical solution for implementing AIS monitoring systems at the research and basic application levels.

  • Open Access

    Optimization of coas doctor selection using PROMETHEE-based decision support system

    by M Salim, Sulistiawati Rahayu Ahmad, Yulanda Yunus

    The selection process of co-assistant (COAS) doctors in hospitals is a critical stage in ensuring the quality of healthcare services. However, in practice, this process is often conducted subjectively and lacks integration with a structured criteria-based system, which may lead to inconsistent and less accurate decision-making. However, existing studies still lack the implementation of integrated web-based decision support systems with validated ranking results, particularly in the context of COAS doctor selection. This study aims to optimize the selection process of COAS doctors by implementing a decision support system based on the Preference Ranking Organization Method for Enrichment Evaluation (PROMETHEE). The method is used to rank alternatives through a multi-criteria decision-making approach involving seven criteria, namely medical knowledge, service attitude, productivity, teamwork, discipline, honesty, and responsibility. The results show that the developed system is capable of generating objective candidate rankings, where the highest net flow value of 0.95 is achieved by the best candidate, indicating strong dominance over other alternatives. Furthermore, the implementation of the PROMETHEE method improves transparency and consistency in decision-making while reducing subjectivity compared to manual approaches. The web-based system also enhances efficiency through automated calculations and real-time data processing. Therefore, this study contributes to the development of multi-criteria decision support systems in the healthcare sector, particularly in providing a more objective, systematic, and efficient approach to COAS doctor selection.

  • Open Access

    Techno - economic and energy-efficient LLDPE production via advanced sclairtech technology

    by Fathur Ilham Pramana, Hari Rionaldo, Gandi Prasetyo

    Linear Low-Density Polyethylene (LLDPE) is a widely used polymer in the plastics and packaging industries because of its flexibility and good mechanical properties. The increasing global demand for LLDPE encourages the development of more energy- and cost-efficient production technologies. This study aims to analyze the technical and economic feasibility of building an LLDPE plant using Advanced Sclairtech Technology (AST). The plant is designed with a production capacity of 287,000 tons/year and optimized using a Heat Exchanger Network (HEN). The design and evaluation of the HEN are carried out using Aspen Energy Analyzer software based on the Temperature Interval and Composite Curve methods. The analysis results show that implementing heat integration can reduce the high-pressure steam requirement from 204,541 kg/hour to 30,770 kg/hour and the cooling water requirement from 6,491,808 kg/hour to 1,527,774 kg/hour. The utility savings achieved exceed 80%, with a reduction in utility costs of USD 6,750 per hour. Economic analysis yields a Payback Period (PBP) of 3.03 years, a Net Present Value (NPV) of USD 84.15 million, an Internal Rate of Return (IRR) of 24.53%, and a Break-Even Point (BEP) of 24.46% of production capacity. Based on the technical and economic analysis results, the LLDPE plant using AST technology is considered feasible. It has the potential to be developed as a more efficient and sustainable LLDPE production technology.

  • Open Access

    Usability testing analysis of the Lhokseumawe district attorney’s office website using nielsen’s metrics for user experience evaluation

    by Ahmad Alfarisyi, Ilham Sahputra, Cut Yuniza Eviyanti, Annisa Karima

    The Lhokseumawe district attorney's office is a law enforcement institution that utilizes a website as an essential medium for delivering public information and services. To ensure its optimal function, this research aims to evaluate the website's usability quality level. This study adopts the Usability Testing method with a quantitative descriptive approach , based on the five metrics proposed by Jakob Nielsen: learnability, efficiency, memorability, errors, and user satisfaction. Data collection involved direct observation of 10 users performing core task scenarios, supplemented by questionnaires and interviews. The test results indicate that the website generally meets several usability aspects. However, there are still significant shortcomings in the areas of efficiency and user satisfaction. Quantitatively, the website's total usability score is 87.5% , with the average satisfaction score using the System Usability Scale (SUS) being 65%. Based on these findings, this study recommends improvements to the navigation structure and user interface (UI) design to enhance the quality of digital services and provide a better user experience (UX). The results of this study are expected to serve as a reference for the website administrators of the Lhokseumawe District Attorney's Office for further system development