Recent in Engineering Science and Technology

Published by PT Mencerdaskan Bangsa Indonesia

Abbrev: Recent Eng. Sci. Technol.
ISSN 2985-8321EISSN 2985-704X
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
60
2025 journal articles
20
Subject
  • Manufacturing
  • Surface Chemistry
  • Electrochemistry
  • Musculoskeletal Disorders
  • Facilities Management
  • AI & Machine Learning

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Manufacturing
19
Surface Chemistry
7
Energy Systems & Technologies
7
AI & Machine Learning
6
Facilities Management
6
Extractive Metallurgy
5
Electrochemistry
5
Power Systems & Electric Vehicles
4
2D Materials
4
Sustainability Studies
4

Top Countries

Publications in 2016-2026.

CountryPublications
Indonesia
48
China
4
United Kingdom
4
Saudi Arabia
1
Australia
1
South Korea
1
Turkey
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
8
Total Publications
20
Average Citations
0.40
Cited Publications
4
Cited Publications %
20%
Self Citations
1
Self Citations %
12.5%

Metrics
h5_index
4
Monthly Citation Metric (MCM)
0.33

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
1
Q3
2
99%
10.5
Max
12

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Analysis of the Development of an Electric Mini Excavator Based on Environmentally Friendly Technology

    by Fuad Zainuri, Rahmat Noval, M. Todaru

    This study analyzes the development of an electric mini excavator based on environmentally friendly technology as an alternative to conventional diesel systems. The research aims to identify energy efficiency improvements, emission reductions, and the design feasibility of converting a hydraulic excavator into an electrically driven system. The method includes literature review, system modeling, and experimental validation on a prototype equipped with electro-hydraulic drive, battery pack, and motor inverter. The results indicate that an increase in hydraulic pressure and battery capacity directly influences the working cycle speed and system stability. The use of electric drives reduced noise by up to 80% and eliminated local exhaust emissions, demonstrating potential environmental benefits. The study concludes that the electric mini excavator is technically feasible for light-duty construction tasks and supports sustainable energy transitions in heavy equipment operations.

  • Open Access

    Analysis of the Effect of Air Inlet Filter Replacement on Gas Turbine Performance at Unit 1A of Bekasi Power Combined Cycle Power Plant

    by Gilang Fitra Ardiansyah, Arifia Eka Yuliana

    The air inlet filter is a critical component in a gas turbine system because it ensures that clean air enters the compressor and combustion chamber. The accumulation of dust, moisture, and airborne contaminants can increase pressure drop across the filter, reducing airflow rate and adversely affecting compressor performance, combustion efficiency, and overall gas turbine operation. This study aims to analyze the effect of air inlet filter replacement on the performance of Gas Turbine GT1A at Bekasi Power Combined Cycle Power Plant (CCPP). A quantitative comparative approach was employed by comparing operational data before and after air inlet filter replacement. Secondary data were obtained from the Distributed Control System (DCS), including compressor inlet temperature, compressor outlettemperature, compressor inlet pressure, compressor outlet pressure, combustion chamber temperature, turbine exhaust temperature, fuel gas flow rate, and generator load. The performance analysis was conducted using Brayton cycle thermodynamic equations to evaluate compressor efficiency, combustion chamber efficiency, turbine efficiency, and thermal efficiency. Furthermore, a Fishbone Diagram (6M) analysis was utilized to identify the root causes leading to air inlet filter replacement. The results indicate that replacing the air inlet filter improves the quality and quantity of intake air supplied to the compressor, leading to enhanced combustion conditions andimproved gas turbine performance. The study highlights the importance of periodic air inlet filter maintenance in maintaining operational reliability, efficiency, and long-term performance of gas turbine systems

  • Open Access

    Auditing Physical Consistency in Engine Fault Detection Using Domain-Informed Monotonic XGBoost and Explainable Boosting Machine

    by Abdul Azis Abdillah

    Machine-learning models for engine fault detection are usually judged by predictive accuracy, although a model can score well while learning relationships that contradict engine physics. This study proposes a physical-consistency audit that combines domain-informed monotonic constraints in XGBoost with the glass-box Explainable Boosting Machine (EBM). Using a public dataset of 19,533 engine records with six sensor variables, seven classifiers were benchmarked under a leakage-safe protocol with a stratified hold-out test set, inner-cross-validated tuning, repeated cross-validation and out-of-fold threshold selection. Three XGBoost configurations with identical hyper-parameters (unconstrained, domain-constrained and reverse-constrained) were then compared. The boosting models performed statistically alike, with EBM the best (test ROC-AUC 0.701). Imposing engineering-consistent constraints significantly reduced ROC-AUC (−0.016 on the test set; 95% CI −0.023 to −0.009) and removed almost all attribution to oil pressure and oil temperature, whereas reversed constraints had no cost. SHAP and EBM shape functions independently showed all three constrained sensors acting opposite to expectation, and semi-synthetic experiments with known physics reproduced this signature only when labels were inverted. The audit therefore exposes physically implausible learning and flags possible label inversion without expert relabelling.

  • Open Access

    Preliminary LEAP-Based Scenario Analysis of Electricity Demand and Renewable Energy Development in South Sulawesi

    by La Ode Masri Ande Kolewora, Arham, Saiful. M, Ahmad Agus Setiawan, Muhammad Taufiq, Virtuous Ikmal Wicaksono

    South Sulawesi possesses abundant renewable energy potential, particularly from hydro, wind, solar, and biomass resources. However, rapid population growth and increasing energy consumption across sectors create challenges in ensuring sustainable energy supply and planning. This study aims to project the mid-term renewable energy supply and demand in South Sulawesi using the Long-range Energy Alternatives Planning (LEAP) model. By simulating various scenarios—including the business-as-usual (BAU) and renewable policy intervention scenarios—this research analyzes the region’s future energy trajectory up to 2035. The findings reveal that South Sulawesi’s average population growth of 1.028% (approximately 142,000 people per year) and electricity demand growth of 7.94% annually significantly increase regional energy needs. Without intervention, fossil fuels will continue to dominate the energy mix, but policy-driven scenarios demonstrate that renewable energy contributions could exceed 45% of the total supply. The study provides valuable insights for regional energy planning and supports policy formulation toward achieving a sustainable, low-carbon energy system in South Sulawesi.

  • Open Access

    Risk-Based Integrity Management of CO₂ Pipelines in CCUS: Integration of Failure Mechanisms, Risk Assessment, and Inspection Strategies—A Review

    by Risdianto, Johny Wahyuadi Soedarsono, Yudha Pratesa

    The accelerated deployment of Carbon Capture, Utilization, and Storage (CCUS) systems requires safe and reliable CO₂ transportation infrastructure. Pipelines remain the most feasible option for large-scale CO₂ transport; however, dense-phase thermodynamics, impurity interactions, decompression behavior, and environmentally assisted degradation create integrity challenges that differ from those of conventional hydrocarbon pipelines. This review examines how failure mechanisms, risk assessment methods, and inspection strategies can be integrated into a Risk-Based Inspection (RBI) framework for CO₂ pipelines. Literature was synthesized from studies indexed in Scopus and Web of Science, with emphasis on corrosion, fracture propagation, probabilistic risk assessment, monitoring technologies, and inspection planning. The reviewed evidence indicates that corrosion-related degradation and running fracture are the most critical threats, while probabilistic and reliability-based approaches are increasingly used to address uncertainty. Nevertheless, integration between degradation assessment, risk modeling, and inspection optimization remains fragmented. This paper proposes a dynamic RBI concept that links CO₂-specific degradation mechanisms, Bayesian risk updating, real-time monitoring, and adaptive inspection scheduling. The proposed synthesis supports more reliable, risk-informed integrity management for future CCUS pipeline networks.

  • Open Access

    Optimization of Fork Tines Design on a 3-Ton Capacity Forklift Using Heel Radius and Thickness Geometry Variation via Finite Element Analysis

    by Ersyam Nur Wahid, Muhammad Prasha Risfi Silitonga

    Structural failure at the heel area of forklift fork tines due to high stress concentration is a serious safety concern in the logistics industry. This study aims to optimize the geometry of ISO Class 3 fork tines with a 3-ton capacity to achieve a design with maximum strength and efficient mass. The design methodology utilizes a 3² factorial design via the Taguchi approach (L9 orthogonal array) by varying the Heel Radius (65, 75, 85 mm) and Base Thickness (40, 50, 60 mm). Testing was performed numerically through static Finite Element Analysis (FEA) on AISI 4140 Alloy Steel, assuming a uniform load of 15,000 N per fork arm at a Load Center distance of 500 mm. Initial validation of the numerical model against analytical cantilever-beam calculations resulted in an error below 1%, confirming simulation accuracy. ANOVA results prove that base thickness is the primary and most dominant parameter significantly affecting stress (P-value 0.003 < 0.05). Through comparative analysis, Design 6 (D6), combining an 85 mm Heel Radius and 50 mm Thickness, was selected as the most optimal configuration, reducing maximum stress to 208.5 MPa and increasing the Factor of Safety (FoS) to 1.99, significantly safer than the factory-standard design (FoS 1.84) while maintaining a mass efficiency of 97 kg. The optimized AISI 4140 design is structurally safe for static operation and is recommended as a fabrication standard.

  • Open Access

    Dynamometer Testing of Electric Vehicles: Methods, Standards, and Emerging Trends

    by Rahmat Noval, Asep Apriana, Danardono Agus Sumarson, Ghany Heryana, Fuad Zainuri, Mohammad Adhitya, Muhammad Hidayat Tullah, Fuzi Rachmat Ramdhan

    Dynamometer testing (dynotest) is essential for evaluating electric vehicle (EV) performance under controlled laboratory conditions, enabling repeatable measurement of power, torque, efficiency, and energy consumption while emulating real-world driving cycles. This review surveys recent developments in EV dynotesting, highlighting IEEE and international test standards, key performance parameters, and evolving methodologies. We compare chassis and hub dyno architectures, including new “vehicle-in-the-loop” and modular test benches, and discuss integration of hardware-in-the-loop (HIL) simulation for real-time controller validation. Standardized drive cycles (e.g. WLTP, EPA/UDDS, JC08) are widely used on dynos to benchmark EV energy use. We summarize representative studies that apply dynotests to EV powertrains, including single-motor and dual-/multi-motor drivetrains. Emerging challenges are reviewed: bidirectional (regen) energy flow, thermal management under high load, synchronization of multiple drive units and batteries, and specialized needs for all-wheel-drive (AWD) and multi-motor EV testing. The review concludes that comprehensive dynotest methods, combined with rigorous standards, HIL integration, and advanced data analysis, are critical for validating next-generation EV drivetrains and enabling accurate energy-consumption benchmarking. Future work should address remaining gaps in multi-axis dyno platforms, long-term durability tests, and AI-driven real-time analysis during dyno runs.

  • Open Access

    Design of a Heavy-Duty Manual Turntable for Heavy Material Handling Activities to Reduce the Potential Risk of Musculoskeletal Disorders (MSDs)

    by Ari Dwiyanto, Agus Edy Pramono, Zuhri Aminudin

    Heavy material handling and rotation activities in the fabrication area are still performed manually using a conventional worktable without a material rotation system. This condition requires the observed operator to bend, twist the body, and repeatedly lift and reposition the material during the work process. These non-neutral working postures have the potential to cause Musculoskeletal Disorders (MSDs), particularly in the neck, shoulders, lower back, arms, and wrists due to excessive and repetitive physical loading. Therefore, this study aims to analyze ergonomic risks in heavy material handling activities and design a Heavy-Duty Manual Turntable to improve operator working posture. The methods used include field observation, work posture documentation, Nordic Body Map (NBM) analysis, posture angle measurement, ergonomic evaluation using Rapid Upper Limb Assessment (RULA) and Rapid Entire Body Assessment (REBA), anthropometric analysis, CAD-based design simulation, and simple biomechanical analysis. The NBM screening was completed by one observed operator and identified complaints in the neck, shoulders, lower back, upper arms, wrists, and lower legs. The initial condition had a RULA score of 6–7 and a REBA score of 9–11. The proposed solution is a Heavy-Duty Manual Turntable Model VP1-R with 360° rotational capability and an adjustable working height. Based on the proposed posture simulation, the estimated RULA score decreased to 2–3 and the estimated REBA score decreased to 2–3. The simplified biomechanical comparison also indicated an approximately 45% reduction in the lower-back moment. Because the post-design assessment was based on CAD simulation and not on a fabricated prototype, these results should be interpreted as preliminary design estimates. This study presents an ergonomic assistive-device design that can be used as a basis for prototype development and field testing.

  • Open Access

    Failure Analysis of Economizer Tube Leakage Caused by Localized Internal Corrosion at Weld-Root Regions

    by Dede Ramadhan, Yudha Pratesa, Johny Wahyuadi Mudaryoto

    Economizer tube leakage is a common failure in industrial boiler systems and may result in unplanned shutdowns and significant production losses. This study investigates the leakage failure of ASTM A210 Grade C economizer tubes removed from a pulp and paper boiler after long-term service. The investigation combined field inspection, wall-thickness measurements, chemical composition analysis, hardness testing, metallography, and SEM–EDS characterization to determine the degradation mechanism responsible for leakage. Leakage was detected in Tube Row 99 and Tube Row 185 near circumferential and stopper-weld locations. Visual examination revealed that damage was concentrated in the weld-root vicinity, whereas adjacent tube sections remained comparatively unaffected. Thickness measurements showed severe localized wall loss, with the minimum remaining thickness decreasing from 3.00 mm to 1.85 mm. Chemical composition analysis confirmed compliance with ASTM A210 Grade C requirements, while hardness testing showed no evidence of abnormal hardening or thermal degradation. Metallographic examination revealed oxide-layer deterioration and corrosion penetration adjacent to the weld-root interface. SEM–EDS analysis identified corrosion products dominated by iron oxides, confirming an internally initiated corrosion process. Available operating records indicated fluctuations in dissolved oxygen concentration, although the monitoring data were incomplete. The results indicate that excessive weld-root penetration promoted deposit retention and localized environmental variations, creating conditions favorable for oxide-layer deterioration and localized internal corrosion. Progressive wall thinning adjacent to the weld-root region subsequently led to through-wall perforation and leakage. The failure mechanism was identified as weld-root-associated localized internal corrosion, while dissolved oxygen fluctuations were considered a contributing factor to corrosion propagation rather than the primary cause of failure.

  • Open Access

    Review on Strengthening Asset Integrity Management through Risk-Based Inspection In Hydrocarbon Piping Systems

    by Edy Karina, Yudha Pratesa, Jhony Wahyuadi Mudaryoto

    Hydrocarbon piping systems are critical assets in oil and gas facilities because they operate under pressure, temperature, fluid variability, and corrosive environments that can accelerate material degradation. This study develops a risk-based integrity evaluation framework for hydrocarbon piping systems by integrating corrosion rate assessment, remaining life estimation, and Risk-Based Inspection (RBI) prioritization within an Asset Integrity Management (AIM) perspective. A quantitative case study was conducted using 2025 inspection data from hydrocarbon and utility piping systems at PT X. The evaluation followed the principles of API RP 580 and API RP 581 and used ultrasonic thickness measurement, actual wall thickness, minimum required thickness, corrosion rate, remaining life, Probability of Failure (PoF), Consequence of Failure (CoF), and risk ranking. The results show that most piping systems were categorized as Very Low Risk, while several lines remained in the Medium Risk category. Utility Water Piping had the highest corrosion rate of 0.253 mmpy and the shortest remaining life of 8 years. Hydrocarbon Gas Piping had a lower corrosion rate of 0.076 mmpy and a remaining life of 38 years. The proposed framework strengthens inspection prioritization, risk-based maintenance, and long-term AIM implementation.