Journal of Electrical Engineering and Informatics
Published by Fakultas Teknik, Universitas Negeri Makassar
- Scilit
- AI & Machine Learning
- Power Systems & Electric Vehicles
- Software Design
- Remote Learning & Research
- Education & Pedagogy
- Electrical Safety
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 9
- Total Publications
- 17
- Average Citations
- 0.53
- Cited Publications
- 7
- Cited Publications %
- 41.2%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 3
- Monthly Citation Metric (MCM)
- 0.48
- Q1
- 0
- Med
- 1
- Q3
- 1
- 99%
- 4
- Max
- 4
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 189-196
Pulse-Resistance Estimation and Health-Weighted Passive Balancing for a Lithium-Ion Pack
Passive balancing that always bleeds the highest terminal voltage ignores a cell whose resistance has already risen. This paper integrates three steps into one simulated balancing loop: ohmic resistance is estimated from a short load step, a pack-relative health index is built from voltage, resistance, and temperature, and the index ranks the cells for passive bleeding. The estimator is the voltage jump divided by the load current; the polarization voltage remains approximately unchanged when the pulse duration is short relative to the RC time constant. The index is a weighted sum after min-max normalization across the pack, with weights 0.10, 0.80, and 0.10 chosen by correlation with capacity. A cell may be bled only if its rest voltage exceeds the pack minimum by more than 2 mV; among such cells, the one with the highest index, which here means the lowest resistance and temperature, is bled first. A four-cell Thevenin-model battery pack was simulated over 200 charge–rest–discharge cycles. Resistance error against the generating model stayed between 0.83 and 1.73 percent. Without balancing, usable pack capacity fell to 0.889 Ah; the voltage rule and the gated health rule both held it at 1.150 Ah with a mean voltage spread below 1 mV. Bleeding the highest index without the voltage gate drained the healthiest cells and reduced usable capacity to zero. Minimum cell capacity and cycle life were equal under every policy because the fade law does not depend on the bleed. The main contribution lies in integrating these three steps into a unified simulation framework. All results come from simulation.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 189-196
Open AccessPulse-Resistance Estimation and Health-Weighted Passive Balancing for a Lithium-Ion Pack
Passive balancing that always bleeds the highest terminal voltage ignores a cell whose resistance has already risen. This paper integrates three steps into one simulated balancing loop: ohmic resistance is estimated from a short load step, a pack-relative health index is built from voltage, resistance, and temperature, and the index ranks the cells for passive bleeding. The estimator is the voltage jump divided by the load current; the polarization voltage remains approximately unchanged when the pulse duration is short relative to the RC time constant. The index is a weighted sum after min-max normalization across the pack, with weights 0.10, 0.80, and 0.10 chosen by correlation with capacity. A cell may be bled only if its rest voltage exceeds the pack minimum by more than 2 mV; among such cells, the one with the highest index, which here means the lowest resistance and temperature, is bled first. A four-cell Thevenin-model battery pack was simulated over 200 charge–rest–discharge cycles. Resistance error against the generating model stayed between 0.83 and 1.73 percent. Without balancing, usable pack capacity fell to 0.889 Ah; the voltage rule and the gated health rule both held it at 1.150 Ah with a mean voltage spread below 1 mV. Bleeding the highest index without the voltage gate drained the healthiest cells and reduced usable capacity to zero. Minimum cell capacity and cycle life were equal under every policy because the fade law does not depend on the bleed. The main contribution lies in integrating these three steps into a unified simulation framework. All results come from simulation.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 181-188
Edge-AI Firmware for Machine Anomaly Detection Using EWMS and Spectral Energy Shift
FFT amplitude thresholds raise false alarms when machine load changes, and storing a full spectral history exceeds microcontroller memory. This paper presents edge-AI firmware that runs the whole decision, from spectrum to alarm, on a microcontroller-class node without a network. Three modules process each vibration frame. An exponential weighted moving spectrum stores a normal fingerprint in one vector. Spectral energy distribution shift scores the frame by the Kullback–Leibler divergence of the normalized spectrum against that fingerprint, so a global gain change cancels out. The alarm threshold is updated only from frames that did not alarm. Tests used 400 synthetic frames of normal running, bearing fault, imbalance, and load drift, against an FFT-peak rule and a total-energy z-score. The 16-bit fingerprint used 512 bytes, 400 times smaller than a 200-frame floating-point buffer. Bearing-fault scores averaged 1,651 times the normal score, while a 30 percent load rise stayed at or below normal. On a 350-frame timeline the proposed threshold kept a 100 percent true-positive rate through the fault, against 4 percent for a conventional adaptive threshold. The mixed-set area under the ROC curve was 1.000 and the F1 score was 0.976, with no missed faults. Each element has precedents; the contribution is their combination, which keeps a sustained fault alarmed with a 512-byte fingerprint. All results are from simulation; the firmware has not yet run on a physical microcontroller.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 181-188
Open AccessEdge-AI Firmware for Machine Anomaly Detection Using EWMS and Spectral Energy Shift
FFT amplitude thresholds raise false alarms when machine load changes, and storing a full spectral history exceeds microcontroller memory. This paper presents edge-AI firmware that runs the whole decision, from spectrum to alarm, on a microcontroller-class node without a network. Three modules process each vibration frame. An exponential weighted moving spectrum stores a normal fingerprint in one vector. Spectral energy distribution shift scores the frame by the Kullback–Leibler divergence of the normalized spectrum against that fingerprint, so a global gain change cancels out. The alarm threshold is updated only from frames that did not alarm. Tests used 400 synthetic frames of normal running, bearing fault, imbalance, and load drift, against an FFT-peak rule and a total-energy z-score. The 16-bit fingerprint used 512 bytes, 400 times smaller than a 200-frame floating-point buffer. Bearing-fault scores averaged 1,651 times the normal score, while a 30 percent load rise stayed at or below normal. On a 350-frame timeline the proposed threshold kept a 100 percent true-positive rate through the fault, against 4 percent for a conventional adaptive threshold. The mixed-set area under the ROC curve was 1.000 and the F1 score was 0.976, with no missed faults. Each element has precedents; the contribution is their combination, which keeps a sustained fault alarmed with a 512-byte fingerprint. All results are from simulation; the firmware has not yet run on a physical microcontroller.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 170-180
Development of a School Information Website for MA Ma’arif Lasepang Using an Agile Approach
This study developed an official information website for Madrasah Aliyah (MA) Ma’arif Lasepang in Bantaeng Regency and evaluated its quality against all eight characteristics of ISO/IEC 25010. A Research and Development (R&D) design with an Agile model was used, covering requirements analysis, design, development, testing, review, and deployment. Data were gathered through observation, interviews, documentation, and questionnaires. The resulting website offers the school profile, news, achievements, teacher data, extracurricular activities, photo and video galleries, online new-student registration (PMBM), and an administrator panel for content management. Quality testing produced the following results. Evaluation results show that the system successfully met all testing parameters: functional suitability scored 100% by experts, usability reached 85.04% (very feasible), and reliability maintained zero failures under a 20-user load test (0.39 s average response time). Furthermore, the application achieved performance efficiency with GTmetrix Grade B (LCP 1.2 s, TBT 11 ms), security at Threat Level 2 (no high vulnerabilities), full maintainability compliance across all criteria, and seamless compatibility and portability across various browsers and device configurations. The website is therefore feasible as a school information channel, but the short load test and the open medium-severity security findings mean that long-term reliability and security still need verification.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 170-180
Open AccessDevelopment of a School Information Website for MA Ma’arif Lasepang Using an Agile Approach
This study developed an official information website for Madrasah Aliyah (MA) Ma’arif Lasepang in Bantaeng Regency and evaluated its quality against all eight characteristics of ISO/IEC 25010. A Research and Development (R&D) design with an Agile model was used, covering requirements analysis, design, development, testing, review, and deployment. Data were gathered through observation, interviews, documentation, and questionnaires. The resulting website offers the school profile, news, achievements, teacher data, extracurricular activities, photo and video galleries, online new-student registration (PMBM), and an administrator panel for content management. Quality testing produced the following results. Evaluation results show that the system successfully met all testing parameters: functional suitability scored 100% by experts, usability reached 85.04% (very feasible), and reliability maintained zero failures under a 20-user load test (0.39 s average response time). Furthermore, the application achieved performance efficiency with GTmetrix Grade B (LCP 1.2 s, TBT 11 ms), security at Threat Level 2 (no high vulnerabilities), full maintainability compliance across all criteria, and seamless compatibility and portability across various browsers and device configurations. The website is therefore feasible as a school information channel, but the short load test and the open medium-severity security findings mean that long-term reliability and security still need verification.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 159-169
Multivariate Anomaly Detection of Three-Phase Electrical Power Systems Using Isolation Forest
The increasing availability of electrical monitoring data provides opportunities for data-driven identification of atypical operating conditions in three-phase electrical systems. This study investigates multivariate anomaly detection using Isolation Forest on an open-source dataset comprising three-phase voltage, current, active power, reactive power, power factor, and frequency measurements. Following data integration and quality assessment, 33,211 complete observations (99.88%) across 18 electrical variables were analyzed. An Isolation Forest model with 300 estimators and contamination set to ‘auto’ identified 7,118 observations (21.43%) as candidate anomalies under its automatic decision threshold, rather than confirmed electrical faults. Continuous anomaly scores and percentile-based lower-tail rankings were subsequently used for characterization. The lowest anomaly scores were primarily associated with phase-B and phase-C current, active power, and reactive power variables, accompanied by reduced phase-C power factor. Frequency exhibited negligible monotonic association with anomaly scores (Spearman’s ρ = 0.0034, p = 0.535), and its exclusion minimally affected anomaly rankings (ρ = 0.9826). Feature-group ablation demonstrated high overall ranking stability (ρ = 0.940–0.983), indicating that observation rankings remained relatively consistent despite the exclusion of individual electrical feature groups. Temporal analysis further revealed a pronounced concentration of low-score observations during 18:00–21:00. These findings demonstrate that combining anomaly ranking, electrical characterization, feature-group sensitivity analysis, and temporal analysis provides an interpretable unsupervised framework for screening and prioritizing atypical multivariate operating conditions in three-phase electrical systems.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 159-169
Open AccessMultivariate Anomaly Detection of Three-Phase Electrical Power Systems Using Isolation Forest
The increasing availability of electrical monitoring data provides opportunities for data-driven identification of atypical operating conditions in three-phase electrical systems. This study investigates multivariate anomaly detection using Isolation Forest on an open-source dataset comprising three-phase voltage, current, active power, reactive power, power factor, and frequency measurements. Following data integration and quality assessment, 33,211 complete observations (99.88%) across 18 electrical variables were analyzed. An Isolation Forest model with 300 estimators and contamination set to ‘auto’ identified 7,118 observations (21.43%) as candidate anomalies under its automatic decision threshold, rather than confirmed electrical faults. Continuous anomaly scores and percentile-based lower-tail rankings were subsequently used for characterization. The lowest anomaly scores were primarily associated with phase-B and phase-C current, active power, and reactive power variables, accompanied by reduced phase-C power factor. Frequency exhibited negligible monotonic association with anomaly scores (Spearman’s ρ = 0.0034, p = 0.535), and its exclusion minimally affected anomaly rankings (ρ = 0.9826). Feature-group ablation demonstrated high overall ranking stability (ρ = 0.940–0.983), indicating that observation rankings remained relatively consistent despite the exclusion of individual electrical feature groups. Temporal analysis further revealed a pronounced concentration of low-score observations during 18:00–21:00. These findings demonstrate that combining anomaly ranking, electrical characterization, feature-group sensitivity analysis, and temporal analysis provides an interpretable unsupervised framework for screening and prioritizing atypical multivariate operating conditions in three-phase electrical systems.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 148-158
Performance Analysis of CNN and LSTM for SARS-CoV-2 Detection Based on Genomic Sequence Data
This study compares the performance of Convolutional Neural Network (CNN) and Long Short-Term Memory (LSTM) architecture implemented with a bidirectional configuration for binary SARS-CoV-2 detection from genomic sequence data. A total of 8,273 sequences were programmatically retrieved from NCBI, comprising 2,000 SARS-CoV-2 sequences and 6,273 sequences from other viruses. Sequences were standardized to 30,000 bases through padding or truncating and transformed using one-hot encoding. A stratified split produced 5,977 training, 1,055 validation, and 1,241 test samples. Because the experimental generator processed only complete batches of 32, final evaluation covered 1,216 of the 1,241 test samples; 25 samples that did not form a complete batch were not included in the reported metric calculations. Both models used Adam, binary cross-entropy, a maximum of 10 epochs, and EarlyStopping. CNN achieved 99.75% accuracy, 98.99% precision, 100% recall, 99.49% F1-score, and 1.0000 ROC-AUC, with 3 misclassifications. LSTM achieved 97.04% accuracy, 94.48% precision, 93.20% recall, 93.84% F1-score, and 0.9953 ROC-AUC, with 36 misclassifications. CNN required 399 seconds for training and 8 seconds for prediction, compared with 3,157 and 29 seconds for LSTM. The contribution is a controlled head-to-head comparison under a shared genomic preprocessing and training pipeline. The observed classification-efficiency advantage of CNN is specific to the dataset, implemented architectures, Google Colab/NVIDIA T4 hardware environment, and training configuration used in this experimental run and should not be interpreted as universal superiority over recurrent architectures.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 148-158
Open AccessPerformance Analysis of CNN and LSTM for SARS-CoV-2 Detection Based on Genomic Sequence Data
This study compares the performance of Convolutional Neural Network (CNN) and Long Short-Term Memory (LSTM) architecture implemented with a bidirectional configuration for binary SARS-CoV-2 detection from genomic sequence data. A total of 8,273 sequences were programmatically retrieved from NCBI, comprising 2,000 SARS-CoV-2 sequences and 6,273 sequences from other viruses. Sequences were standardized to 30,000 bases through padding or truncating and transformed using one-hot encoding. A stratified split produced 5,977 training, 1,055 validation, and 1,241 test samples. Because the experimental generator processed only complete batches of 32, final evaluation covered 1,216 of the 1,241 test samples; 25 samples that did not form a complete batch were not included in the reported metric calculations. Both models used Adam, binary cross-entropy, a maximum of 10 epochs, and EarlyStopping. CNN achieved 99.75% accuracy, 98.99% precision, 100% recall, 99.49% F1-score, and 1.0000 ROC-AUC, with 3 misclassifications. LSTM achieved 97.04% accuracy, 94.48% precision, 93.20% recall, 93.84% F1-score, and 0.9953 ROC-AUC, with 36 misclassifications. CNN required 399 seconds for training and 8 seconds for prediction, compared with 3,157 and 29 seconds for LSTM. The contribution is a controlled head-to-head comparison under a shared genomic preprocessing and training pipeline. The observed classification-efficiency advantage of CNN is specific to the dataset, implemented architectures, Google Colab/NVIDIA T4 hardware environment, and training configuration used in this experimental run and should not be interpreted as universal superiority over recurrent architectures.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 135-147
Transfer Learning CNN for BRCA1 Gene Variant Classification Using a SARS-CoV-2 Detection Architecture
This study aims to develop a one-dimensional Convolutional Neural Network (CNN) using Transfer Learning to classify BRCA1 gene variants into Benign and Pathogenic classes based on their clinical significance. Method: BRCA1 variants obtained from ClinVar were processed into 200 bp DNA sequence windows centered on the variant position and transformed using One-Hot Encoding into 200 × 4 representations. The CNN was trained through three stages: pretraining, Transfer Learning with frozen convolutional layers, and Fine-Tuning. Model performance was evaluated using accuracy, precision, recall, specificity, F1-score, ROC-AUC, and confusion matrix. Results: The final model achieved 84.70% accuracy, 85.28% precision, 85.70% recall, 83.59% specificity, 85.49% F1-score, and 91.50% ROC-AUC on 4,588 unseen test sequences. Fine-Tuning increased training accuracy from 90.27% to 90.92%, with a best validation accuracy of 85.03%. Novelty: This study demonstrates the adaptation of a CNN architecture previously applied to SARS-CoV-2 detection for BRCA1 DNA sequence classification. The findings indicate that the adapted architecture can learn meaningful sequence patterns and provide a promising computational approach for BRCA1 variant classification.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 135-147
Open AccessTransfer Learning CNN for BRCA1 Gene Variant Classification Using a SARS-CoV-2 Detection Architecture
This study aims to develop a one-dimensional Convolutional Neural Network (CNN) using Transfer Learning to classify BRCA1 gene variants into Benign and Pathogenic classes based on their clinical significance. Method: BRCA1 variants obtained from ClinVar were processed into 200 bp DNA sequence windows centered on the variant position and transformed using One-Hot Encoding into 200 × 4 representations. The CNN was trained through three stages: pretraining, Transfer Learning with frozen convolutional layers, and Fine-Tuning. Model performance was evaluated using accuracy, precision, recall, specificity, F1-score, ROC-AUC, and confusion matrix. Results: The final model achieved 84.70% accuracy, 85.28% precision, 85.70% recall, 83.59% specificity, 85.49% F1-score, and 91.50% ROC-AUC on 4,588 unseen test sequences. Fine-Tuning increased training accuracy from 90.27% to 90.92%, with a best validation accuracy of 85.03%. Novelty: This study demonstrates the adaptation of a CNN architecture previously applied to SARS-CoV-2 detection for BRCA1 DNA sequence classification. The findings indicate that the adapted architecture can learn meaningful sequence patterns and provide a promising computational approach for BRCA1 variant classification.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 127-134
WORD2VEC Versus Random Embedding Initialization for SARS-COV-2 Genome Classification using CNN
This study evaluates whether contextual Word2Vec initialization provides a consistent performance advantage over Random Embedding initialization for SARS-CoV-2 genome classification using a Convolutional Neural Network (CNN). A computational experiment was conducted using 76,856 cleaned genome sequences from NCBI Virus, consisting of SARS-CoV-2 and non-SARS-CoV-2 respiratory viruses. The data were stratified at the genome level into training, validation, and testing subsets with an 80:10:10 ratio before sliding-window segmentation. Sequences were segmented into 1,000-base windows with a 500-base step and tokenized into overlapping 6-mers. Word2Vec provided pretrained 100-dimensional embedding weights, while Random Embedding used randomly initialized weights with the same vocabulary and dimension. Both embedding layers remained trainable and used the same CNN configuration across three runs. At the window level, Word2Vec achieved balanced accuracy of 0.999572 ± 0.000283 and MCC of 0.984809 ± 0.013068, while Random Embedding achieved 0.999628 ± 0.000076 and 0.988734 ± 0.002149, respectively. PR-AUC for the minority non-SARS-CoV-2 class was 0.997643 ± 0.001402 for Word2Vec and 0.997282 ± 0.002533 for Random Embedding. At the genome level, both approaches produced identical decisions across all three runs and correctly classified 6,743 of 6,744 evaluable genomes. The controlled comparison isolates the effect of embedding initialization and shows that Word2Vec initialization does not provide a consistent performance advantage over trainable Random Embedding under the evaluated configuration.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 127-134
Open AccessWORD2VEC Versus Random Embedding Initialization for SARS-COV-2 Genome Classification using CNN
This study evaluates whether contextual Word2Vec initialization provides a consistent performance advantage over Random Embedding initialization for SARS-CoV-2 genome classification using a Convolutional Neural Network (CNN). A computational experiment was conducted using 76,856 cleaned genome sequences from NCBI Virus, consisting of SARS-CoV-2 and non-SARS-CoV-2 respiratory viruses. The data were stratified at the genome level into training, validation, and testing subsets with an 80:10:10 ratio before sliding-window segmentation. Sequences were segmented into 1,000-base windows with a 500-base step and tokenized into overlapping 6-mers. Word2Vec provided pretrained 100-dimensional embedding weights, while Random Embedding used randomly initialized weights with the same vocabulary and dimension. Both embedding layers remained trainable and used the same CNN configuration across three runs. At the window level, Word2Vec achieved balanced accuracy of 0.999572 ± 0.000283 and MCC of 0.984809 ± 0.013068, while Random Embedding achieved 0.999628 ± 0.000076 and 0.988734 ± 0.002149, respectively. PR-AUC for the minority non-SARS-CoV-2 class was 0.997643 ± 0.001402 for Word2Vec and 0.997282 ± 0.002533 for Random Embedding. At the genome level, both approaches produced identical decisions across all three runs and correctly classified 6,743 of 6,744 evaluable genomes. The controlled comparison isolates the effect of embedding initialization and shows that Word2Vec initialization does not provide a consistent performance advantage over trainable Random Embedding under the evaluated configuration.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 118-126
Energy-Consistent dq Modeling of Synchronous Generator Dynamics: Electrical and Mechanical Parameter Effects
This study aimed to determine how stator resistance, rotor saliency, mechanical torque, viscous damping, and terminal voltage influence the transient response of a synchronous generator, while avoiding conclusions based on inconsistent power conventions or an insufficient observation period. An energy consistent, three state dq model with outward generator currents and constant rotor flux was derived. Ten illustrative scenarios were computed over five seconds using an adaptive Runge–Kutta method. Independent solver comparison, an integrated energy balance, analytical equilibrium calculation, and local eigenvalue analysis were used to check the results. Increasing stator resistance from 0.2 to 0.8 Ω reduced the sampled peak current from 172.93 to 134.68 A. Increasing mechanical torque from 100 to 200 N m increased the five second rotor speed from 178.77 to 339.12 rad/s. Raising terminal q axis voltage from 150 to 300 V increased peak current from 115.58 to 202.85 A. All scenarios remained accelerating at five seconds; the baseline acceleration was 48.23 rad/s². The maximum normalized energy discrepancy was 1.08 × 10⁻⁹. The study integrates five parameter investigations within one checked model and distinguishes finite horizon behavior from formal equilibrium. Its contribution is a reproducible diagnostic framework for generator modeling rather than a claim of experimentally validated machine performance.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 118-126
Open AccessEnergy-Consistent dq Modeling of Synchronous Generator Dynamics: Electrical and Mechanical Parameter Effects
This study aimed to determine how stator resistance, rotor saliency, mechanical torque, viscous damping, and terminal voltage influence the transient response of a synchronous generator, while avoiding conclusions based on inconsistent power conventions or an insufficient observation period. An energy consistent, three state dq model with outward generator currents and constant rotor flux was derived. Ten illustrative scenarios were computed over five seconds using an adaptive Runge–Kutta method. Independent solver comparison, an integrated energy balance, analytical equilibrium calculation, and local eigenvalue analysis were used to check the results. Increasing stator resistance from 0.2 to 0.8 Ω reduced the sampled peak current from 172.93 to 134.68 A. Increasing mechanical torque from 100 to 200 N m increased the five second rotor speed from 178.77 to 339.12 rad/s. Raising terminal q axis voltage from 150 to 300 V increased peak current from 115.58 to 202.85 A. All scenarios remained accelerating at five seconds; the baseline acceleration was 48.23 rad/s². The maximum normalized energy discrepancy was 1.08 × 10⁻⁹. The study integrates five parameter investigations within one checked model and distinguishes finite horizon behavior from formal equilibrium. Its contribution is a reproducible diagnostic framework for generator modeling rather than a claim of experimentally validated machine performance.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 93-98
Mathematical Modeling of Household Electricity Use Based On Time Variation and Appliance-Use Intensity in Minasa Upa, Makassar, Indonesia
This study develops a parsimonious and physically interpretable framework for describing household electricity use by combining appliance operating intensity, dominant temporal-use patterns, and an empirical consumption model. A quantitative survey was conducted among 93 households. Descriptive analysis characterized appliance operating intensity and dominant use periods, while the primary empirical model used 37 observations with explicitly recorded monthly electricity consumption in kWh. Candidate models were assessed using residual diagnostics, heteroskedasticity and normality tests, multicollinearity assessment, and five-fold cross-validation. The selected model was ln(E) = -5,3721 + 1,5946 ln(D), where E is monthly electricity consumption and D is installed power. The regression explained 57,23% of variance on the logarithmic scale (adjusted R² = 0,560). After smearing correction and back-transformation, the observed–predicted R² was approximately 0,679. The model showed no statistical evidence of heteroskedasticity (Breusch-Pagan p = 0,960) or non-normal residuals (Jarque-Bera p = 0,935), with VIF = 1,00. Five-fold cross-validation produced R² = 0,560, MAE = 195,22 kWh, and RMSE = 248,85 kWh. The study contributes a validation-oriented two-layer framework that separates a physical appliance-intensity formulation from an empirical household consumption model. This design preserves interpretability while avoiding unverified reconstruction of kWh from billing values and demonstrates how parsimonious modeling can remain useful when field data are heterogeneous and high-resolution smart-meter records are unavailable.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 93-98
Open AccessMathematical Modeling of Household Electricity Use Based On Time Variation and Appliance-Use Intensity in Minasa Upa, Makassar, Indonesia
This study develops a parsimonious and physically interpretable framework for describing household electricity use by combining appliance operating intensity, dominant temporal-use patterns, and an empirical consumption model. A quantitative survey was conducted among 93 households. Descriptive analysis characterized appliance operating intensity and dominant use periods, while the primary empirical model used 37 observations with explicitly recorded monthly electricity consumption in kWh. Candidate models were assessed using residual diagnostics, heteroskedasticity and normality tests, multicollinearity assessment, and five-fold cross-validation. The selected model was ln(E) = -5,3721 + 1,5946 ln(D), where E is monthly electricity consumption and D is installed power. The regression explained 57,23% of variance on the logarithmic scale (adjusted R² = 0,560). After smearing correction and back-transformation, the observed–predicted R² was approximately 0,679. The model showed no statistical evidence of heteroskedasticity (Breusch-Pagan p = 0,960) or non-normal residuals (Jarque-Bera p = 0,935), with VIF = 1,00. Five-fold cross-validation produced R² = 0,560, MAE = 195,22 kWh, and RMSE = 248,85 kWh. The study contributes a validation-oriented two-layer framework that separates a physical appliance-intensity formulation from an empirical household consumption model. This design preserves interpretability while avoiding unverified reconstruction of kWh from billing values and demonstrates how parsimonious modeling can remain useful when field data are heterogeneous and high-resolution smart-meter records are unavailable.
- Open Access
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 99-106
An Explainable AI Framework for Bias Detection in Indonesian Sentiment Analysis
The development of deep learning models in sentiment analysis has significantly improved the accuracy of text classification. However, these models are generally black-box, making them difficult to interpret and potentially contain undetectable biases. This study aims to detect and evaluate bias in sentiment analysis models using SHAP-based Explainable Artificial Intelligence (XAI) approach. The model used is IndoBERT which is trained on the Indonesian sentiment dataset. The research stages include data preprocessing, model training, interpretability analysis using SHAP, and fairness evaluation using disparate impact metrics. The results showed that the model achieved an accuracy of 88%, but SHAP analysis revealed the dominance of certain features in decision-making. In addition, fairness evaluation shows that there is an inequality in the distribution of predictions between groups. These findings show that high accuracy does not guarantee model fairness, so Explainable AI integration is important in the development of transparent and accountable NLP systems.
- 14 August 2026
- Published by Fakultas Teknik, Universitas Negeri Makassar in Journal of Electrical Engineering and Informatics
- Vol. 4 (1) , 99-106
Open AccessAn Explainable AI Framework for Bias Detection in Indonesian Sentiment Analysis
The development of deep learning models in sentiment analysis has significantly improved the accuracy of text classification. However, these models are generally black-box, making them difficult to interpret and potentially contain undetectable biases. This study aims to detect and evaluate bias in sentiment analysis models using SHAP-based Explainable Artificial Intelligence (XAI) approach. The model used is IndoBERT which is trained on the Indonesian sentiment dataset. The research stages include data preprocessing, model training, interpretability analysis using SHAP, and fairness evaluation using disparate impact metrics. The results showed that the model achieved an accuracy of 88%, but SHAP analysis revealed the dominance of certain features in decision-making. In addition, fairness evaluation shows that there is an inequality in the distribution of predictions between groups. These findings show that high accuracy does not guarantee model fairness, so Explainable AI integration is important in the development of transparent and accountable NLP systems.