Journal of Engineering and Sciences
Published by Nepal Journals Online (JOL)
- Scilit
- Climate Change
- Geotechnical Engineering
- AI & Machine Learning
- Power Systems & Electric Vehicles
- Hydrometeorology
- Computer-Aided Engineering
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 43
- Total Publications
- 44
- Average Citations
- 0.98
- Cited Publications
- 20
- Cited Publications %
- 45.5%
- Self Citations
- 2
- Self Citations %
- 4.7%
- Q1
- 0
- Med
- 1
- Q3
- 3
- 99%
- 8.6
- Max
- 9
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Identification of Optimal Stream Flow Estimation Techniques In Myagdi River Basin
The Myagdi River basin is vital component for the region’s ecological and socioeconomics systems making an in depth understanding of its hydrological behavior essential. This study applies the hydrological engineering center’s hydrologic modeling systems (HEC-HMS) to simulate and analysis stream flow within the basin with the broader goal of the strengthening water resource management and improving flood risk mitigating strategies. Comprehensive data collection and rigorous model calibration were carried out to ensure reliable outputs. The model demonstrated excellent performance with Nash-Sutcliffe Efficiency (NSE) values of 0.9829 during calibration and 0.9869 during validation, indicating a strong agreement between simulated and observed flow. HEC-HMS effectively replicated flood peaks, estimating a maximum discharge of 210.5m3/s closely aligning with the observed 205.7m3/s. The simulation produced an average monthly discharge of 79.95 m³/s, confirming the model's robustness and suitability for hydrological assessment. To complement the flow analysis, the Gumbel distribution method was employed for flood frequency estimation. This approach provided crucial insights into flood magnitudes associated with 10, 25, 50 and 100 years return periods, highlights significant potential risk within the basin. These findings reinforce the value of the model in guiding flood preparedness and infrastructure planning. The study contributes important knowledge on the basin’s hydrological and demonstrates the capability of HEC-HMS as an effective tool for future evaluations. Key recommendation includes integrating climate change projections, improving the density and quality of hydrological data, and promoting stakeholder collaboration to enhance sustainable watershed management. Implementing these strategies will bolster the basin’s resilience to hydrological extremes and support long term regional development.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessIdentification of Optimal Stream Flow Estimation Techniques In Myagdi River Basin
The Myagdi River basin is vital component for the region’s ecological and socioeconomics systems making an in depth understanding of its hydrological behavior essential. This study applies the hydrological engineering center’s hydrologic modeling systems (HEC-HMS) to simulate and analysis stream flow within the basin with the broader goal of the strengthening water resource management and improving flood risk mitigating strategies. Comprehensive data collection and rigorous model calibration were carried out to ensure reliable outputs. The model demonstrated excellent performance with Nash-Sutcliffe Efficiency (NSE) values of 0.9829 during calibration and 0.9869 during validation, indicating a strong agreement between simulated and observed flow. HEC-HMS effectively replicated flood peaks, estimating a maximum discharge of 210.5m3/s closely aligning with the observed 205.7m3/s. The simulation produced an average monthly discharge of 79.95 m³/s, confirming the model's robustness and suitability for hydrological assessment. To complement the flow analysis, the Gumbel distribution method was employed for flood frequency estimation. This approach provided crucial insights into flood magnitudes associated with 10, 25, 50 and 100 years return periods, highlights significant potential risk within the basin. These findings reinforce the value of the model in guiding flood preparedness and infrastructure planning. The study contributes important knowledge on the basin’s hydrological and demonstrates the capability of HEC-HMS as an effective tool for future evaluations. Key recommendation includes integrating climate change projections, improving the density and quality of hydrological data, and promoting stakeholder collaboration to enhance sustainable watershed management. Implementing these strategies will bolster the basin’s resilience to hydrological extremes and support long term regional development.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Assessment of Indoor Air Quality in Selected Residential Buildings of Kathmandu Using Low-Cost PM2.5 Monitoring and Occupant Perception Survey
Indoor air quality (IAQ) has become a critical environmental health concern, particularly in rapidly urbanizing cities where outdoor pollution infiltrates residential environments. This study assessed indoor air quality in selected residential buildings in the Gyaneshwor area of Kathmandu Valley using a low-cost PM2.5 sensor combined with an occupant questionnaire survey. Real-time measurements of PM2.5 concentration, temperature, and relative humidity were conducted in kitchens and living rooms of four residential houses over seven consecutive days during winter. A structured questionnaire survey involving 15 occupants were conducted to examine awareness of air quality, ventilation practices, and health symptoms related to indoor exposure. The results showed that indoor PM2.5 concentrations frequently exceeded the health-based guideline value of 15 µg/m³ recommended by the World Health Organization, with levels often exceeding 100 µg/m³. Higher concentrations were consistently observed in kitchens compared to living rooms, indicating the influence of indoor activities such as cooking. Survey findings revealed low awareness of the Air Quality Index (AQI) and limited preventive practices, despite a high prevalence of symptoms such as headache, cough, and fatigue among occupants. The study highlights that residential indoor environments in Kathmandu may not provide adequate protection from particulate pollution and emphasizes the need for improved ventilation strategies, public awareness, and policy attention to indoor air quality.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessAssessment of Indoor Air Quality in Selected Residential Buildings of Kathmandu Using Low-Cost PM2.5 Monitoring and Occupant Perception Survey
Indoor air quality (IAQ) has become a critical environmental health concern, particularly in rapidly urbanizing cities where outdoor pollution infiltrates residential environments. This study assessed indoor air quality in selected residential buildings in the Gyaneshwor area of Kathmandu Valley using a low-cost PM2.5 sensor combined with an occupant questionnaire survey. Real-time measurements of PM2.5 concentration, temperature, and relative humidity were conducted in kitchens and living rooms of four residential houses over seven consecutive days during winter. A structured questionnaire survey involving 15 occupants were conducted to examine awareness of air quality, ventilation practices, and health symptoms related to indoor exposure. The results showed that indoor PM2.5 concentrations frequently exceeded the health-based guideline value of 15 µg/m³ recommended by the World Health Organization, with levels often exceeding 100 µg/m³. Higher concentrations were consistently observed in kitchens compared to living rooms, indicating the influence of indoor activities such as cooking. Survey findings revealed low awareness of the Air Quality Index (AQI) and limited preventive practices, despite a high prevalence of symptoms such as headache, cough, and fatigue among occupants. The study highlights that residential indoor environments in Kathmandu may not provide adequate protection from particulate pollution and emphasizes the need for improved ventilation strategies, public awareness, and policy attention to indoor air quality.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Stabilization of Low Plastic Clay Soil with Recycled Pet Strips
Expansive and low plasticity clay soils pose significant challenges in geotechnical engineering due to their low bearing capacity, low strength, and high volumetric instability under moisture variations, often leading to excessive settlements, cracking, and premature failures of pavements and shallow foundations. Conventional stabilization methods such as cement and lime are also effective but are associated with high cost, carbon emissions, and environmental concerns. Simultaneously, the accumulation of Polyethylene Terephthalate (PET) waste has become a critical environmental issue particularly in developing countries like Nepal, highlighting the importance of sustainable reuse solutions. This study presents an experimental investigation on the stabilization of low plastic clay (CL) soil using waste PET bottle strips. Soil samples were collected from the Kalimati area of Kathmandu at a depth of 1.5 m and subjected to standard laboratory tests including moisture content, Standard Proctor compaction, Atterberg limits, and specific gravity. The untreated soil exhibited an Optimum Moisture Content (OMC) of 28% and Maximum Dry Density (MDD) of 1.54 g/cm3. With increasing PET content (0-1.25%), MDD decreased to 1.45 g/cm3 while OMC reduced to 22%, indicating a reduction in water affinity and density variation. Unconfined Compressive Strength (UCS) improved significantly from 37.79 kPa (0% PET) to a maximum of 58.22 kPa at 1% PET, representing a strength increment of 54.82%. Beyond the optimum content, UCS decreased to 52.11 kPa at 1.25% PET due to reduction of soil-strip interaction efficiency. The results confirm that 1% PET content provides optimum reinforcement, improving strength, ductility and overall soil performance. The study demonstrates that waste PET bottle strips can serve as an effective, low cost and environmentally sustainable alternative for soil stabilization in pavement subgrades and shallow foundation systems, while simultaneously addressing plastic waste management challenges.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessStabilization of Low Plastic Clay Soil with Recycled Pet Strips
Expansive and low plasticity clay soils pose significant challenges in geotechnical engineering due to their low bearing capacity, low strength, and high volumetric instability under moisture variations, often leading to excessive settlements, cracking, and premature failures of pavements and shallow foundations. Conventional stabilization methods such as cement and lime are also effective but are associated with high cost, carbon emissions, and environmental concerns. Simultaneously, the accumulation of Polyethylene Terephthalate (PET) waste has become a critical environmental issue particularly in developing countries like Nepal, highlighting the importance of sustainable reuse solutions. This study presents an experimental investigation on the stabilization of low plastic clay (CL) soil using waste PET bottle strips. Soil samples were collected from the Kalimati area of Kathmandu at a depth of 1.5 m and subjected to standard laboratory tests including moisture content, Standard Proctor compaction, Atterberg limits, and specific gravity. The untreated soil exhibited an Optimum Moisture Content (OMC) of 28% and Maximum Dry Density (MDD) of 1.54 g/cm3. With increasing PET content (0-1.25%), MDD decreased to 1.45 g/cm3 while OMC reduced to 22%, indicating a reduction in water affinity and density variation. Unconfined Compressive Strength (UCS) improved significantly from 37.79 kPa (0% PET) to a maximum of 58.22 kPa at 1% PET, representing a strength increment of 54.82%. Beyond the optimum content, UCS decreased to 52.11 kPa at 1.25% PET due to reduction of soil-strip interaction efficiency. The results confirm that 1% PET content provides optimum reinforcement, improving strength, ductility and overall soil performance. The study demonstrates that waste PET bottle strips can serve as an effective, low cost and environmentally sustainable alternative for soil stabilization in pavement subgrades and shallow foundation systems, while simultaneously addressing plastic waste management challenges.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Design and Simulation of VRF AC system in cinema hall using ammonia refrigerants
This study presents the modeling, simulation, and validation of a dual-zone Variable Refrigerant Flow (VRF) air-conditioning system using ammonia (R-717) as the working fluid in MATLAB/Simulink. The system comprises detailed subsystem models i.e compressor, condenser, expansion valves, evaporators, and a building thermal network integrated with dynamic control for compressor and fan operation. Indoor loads for two cinema zones were simulated with combined sensible and latent heat effects. System performance was assessed through temperature response, cooling capacity, power consumption, and coefficient of performance (COP). Simulated COPs ranged from 3.8 to 4.4, while analytical validation gave 3.749 – 5.41, with percentage errors between 0.58% and 21.92%, indicating strong correlation under moderate loads and deviations under part-load conditions. Compared to a reference R-410A VRF system (COP = 3.2), the R-717 model demonstrated superior performance across most operating state. The study also incorporates a leak detection mechanism based on refrigerant mass imbalance and indoor concentration monitoring, enhancing system safety. The study highlights the critical role of ventilation in mitigating refrigerant leakage.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessDesign and Simulation of VRF AC system in cinema hall using ammonia refrigerants
This study presents the modeling, simulation, and validation of a dual-zone Variable Refrigerant Flow (VRF) air-conditioning system using ammonia (R-717) as the working fluid in MATLAB/Simulink. The system comprises detailed subsystem models i.e compressor, condenser, expansion valves, evaporators, and a building thermal network integrated with dynamic control for compressor and fan operation. Indoor loads for two cinema zones were simulated with combined sensible and latent heat effects. System performance was assessed through temperature response, cooling capacity, power consumption, and coefficient of performance (COP). Simulated COPs ranged from 3.8 to 4.4, while analytical validation gave 3.749 – 5.41, with percentage errors between 0.58% and 21.92%, indicating strong correlation under moderate loads and deviations under part-load conditions. Compared to a reference R-410A VRF system (COP = 3.2), the R-717 model demonstrated superior performance across most operating state. The study also incorporates a leak detection mechanism based on refrigerant mass imbalance and indoor concentration monitoring, enhancing system safety. The study highlights the critical role of ventilation in mitigating refrigerant leakage.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Forensic Investigation of Submerged Draft Tube Outlet Gate Failure: A Case Study of Incident at Upper Trishuli-3A
The paper deals with a Forensic Engineering Study on the Draft Tube Outlet Gate (DTOG) collapse at Upper Trishuli-3A Hydropower Station. The aim of this research was to find the probable cause of the gate failure using a technique that incorporates scenario recreation, observed operation, as well as Finite Element (FE) Modal Analysis. Data extracted from the SCADA system and observations taken from CCTV footage provided the scenario development with evidence for the collapse sequence. The design document, notes gathered from the post - accident inspection and statements collected from involved authorities supplied supplementary useful information. A 3D FE model was prepared of the DTOG and hoisting machine using relevant design drawings and a mode shape analysis was undertaken to extract inherent structural modes. Findings show that the gate was affected by erratic vibrations prior to failure of its hoist - rod - sleeve bolt connection, then finally it completely fell. After evaluating vibration characteristics, the 5th mode stood out because it corresponded to the hoist rod vibrating along its load path. Its non - wetted (dry) frequency was found to be 11.603 Hertz, but the runner, whirling at 428.57 rpm, was generating vibrations at a frequency of 7.143 Hz. The presence of water will add mass effects, potentially bringing the mode frequency down and increasing vibration. Accounting for this added-mass effect (an estimated 30-33% reduction based on the increase in effective modal mass), the submerged (wet) natural frequency of Mode 5 is estimated at approximately 7.77-8.12 Hz, close to the runner excitation frequency of 7.143 Hz.So the failure resulted in flow - induced vibration of the DTOG with its fatigue sensitive connections.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessForensic Investigation of Submerged Draft Tube Outlet Gate Failure: A Case Study of Incident at Upper Trishuli-3A
The paper deals with a Forensic Engineering Study on the Draft Tube Outlet Gate (DTOG) collapse at Upper Trishuli-3A Hydropower Station. The aim of this research was to find the probable cause of the gate failure using a technique that incorporates scenario recreation, observed operation, as well as Finite Element (FE) Modal Analysis. Data extracted from the SCADA system and observations taken from CCTV footage provided the scenario development with evidence for the collapse sequence. The design document, notes gathered from the post - accident inspection and statements collected from involved authorities supplied supplementary useful information. A 3D FE model was prepared of the DTOG and hoisting machine using relevant design drawings and a mode shape analysis was undertaken to extract inherent structural modes. Findings show that the gate was affected by erratic vibrations prior to failure of its hoist - rod - sleeve bolt connection, then finally it completely fell. After evaluating vibration characteristics, the 5th mode stood out because it corresponded to the hoist rod vibrating along its load path. Its non - wetted (dry) frequency was found to be 11.603 Hertz, but the runner, whirling at 428.57 rpm, was generating vibrations at a frequency of 7.143 Hz. The presence of water will add mass effects, potentially bringing the mode frequency down and increasing vibration. Accounting for this added-mass effect (an estimated 30-33% reduction based on the increase in effective modal mass), the submerged (wet) natural frequency of Mode 5 is estimated at approximately 7.77-8.12 Hz, close to the runner excitation frequency of 7.143 Hz.So the failure resulted in flow - induced vibration of the DTOG with its fatigue sensitive connections.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Graphical exploration for an economic diameter of penstock pipe: A case study of the Middle Kali Gandaki Hydropower Project, Nepal
The design and cost of penstock pipes are significant in hydropower plants with medium to high heads. The empirical formulas for designing practice often rely on simplifying assumptions that are not grasped in all situations for implementation. The economic diameter is an optimum size on the graph where the sum of the overall cost of shaft construction and the cost of energy loss is minimal. This study reports a novel approach to optimize the diameter of the penstock, integrating the cost of energy loss on conventional relations, concluding with a graphical summary. The methodology encompasses the calculation of shaft cost based on the segmented weight of the penstock, incorporating a necessary safety factor and installation expenses, as is conventional practice. The monthly analysis of the cost of energy loss to optimize the size provides dynamic insight into the cost of energy losses using Microsoft Excel. The economic diameter was found to be 3.9 m within the study range of 2.8 m to 4.6 m for a design flow rate of 52.85 m³/s and a gross head of 144 m. Further, it can be more precise by incorporating additional losses and sensitivity analysis, with the expectation of being used as a practical tool in designing new plants of different capacities.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessGraphical exploration for an economic diameter of penstock pipe: A case study of the Middle Kali Gandaki Hydropower Project, Nepal
The design and cost of penstock pipes are significant in hydropower plants with medium to high heads. The empirical formulas for designing practice often rely on simplifying assumptions that are not grasped in all situations for implementation. The economic diameter is an optimum size on the graph where the sum of the overall cost of shaft construction and the cost of energy loss is minimal. This study reports a novel approach to optimize the diameter of the penstock, integrating the cost of energy loss on conventional relations, concluding with a graphical summary. The methodology encompasses the calculation of shaft cost based on the segmented weight of the penstock, incorporating a necessary safety factor and installation expenses, as is conventional practice. The monthly analysis of the cost of energy loss to optimize the size provides dynamic insight into the cost of energy losses using Microsoft Excel. The economic diameter was found to be 3.9 m within the study range of 2.8 m to 4.6 m for a design flow rate of 52.85 m³/s and a gross head of 144 m. Further, it can be more precise by incorporating additional losses and sensitivity analysis, with the expectation of being used as a practical tool in designing new plants of different capacities.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Computed Radiography for Quality Control of Hydropower Penstock Pipe in Nepal
Non-Destructive Testing (NDT) has been extensively used for the inspection of hydropower components in Nepal. Hydropower component penstock pipes are fabricated by rolling mild steel plate. The edges of the rolled plate are arc welded or submerged arc welded (SAW) along its longitudinal or spiral direction. These pipes are circumferentially welded at hydropower construction site to make a desire length of penstock from headrace to turbine. In Nepal, the quality of such welded penstock pipe is inspected using four different NDT methods such as radiography, ultrasound, magnetic and dye penetrant. These four methods are equally important for the inspection of penstock pipe. But the major part of NDT word is covered by radiography and ultrasound in Nepal. The limitation of radiography is its tedious film developing and processing time required. Therefore, pulse echo ultrasound has been widely used in favor of radiography testing. The pulse echo ultrasound testing results are not reliable because discontinuities results listed by NDT Level 1 personnel depends on their skills and judgments. And the pulse echo ultrasound does not produce visible image or report for record keeping. Thus, modern computed digital radiography which uses imaging plate (IP) has came as an alternative NDT testing of conventional pulse echo ultrasound testing. Computed radiography (CR) being modern digital radiography produces visible radiation images of welding and supports computer, based image processing for image evaluation and discontinuities interpretation. CR technology also supports measurement of wall thickness of the penstock pipe that was remained from corrosion. It also supports double wall double image techniques for the pipes less than 100 mm in outside diameter. Standards and codes for the CR technique have been well developed for its application for pressure vessels such as hydropower, storage tanks, casting products and aluminum products. Finally, this paper illustrates modern CR technology for inspection of penstock pipe used in hydropower for the efficient construction, testing and repairing.
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessComputed Radiography for Quality Control of Hydropower Penstock Pipe in Nepal
Non-Destructive Testing (NDT) has been extensively used for the inspection of hydropower components in Nepal. Hydropower component penstock pipes are fabricated by rolling mild steel plate. The edges of the rolled plate are arc welded or submerged arc welded (SAW) along its longitudinal or spiral direction. These pipes are circumferentially welded at hydropower construction site to make a desire length of penstock from headrace to turbine. In Nepal, the quality of such welded penstock pipe is inspected using four different NDT methods such as radiography, ultrasound, magnetic and dye penetrant. These four methods are equally important for the inspection of penstock pipe. But the major part of NDT word is covered by radiography and ultrasound in Nepal. The limitation of radiography is its tedious film developing and processing time required. Therefore, pulse echo ultrasound has been widely used in favor of radiography testing. The pulse echo ultrasound testing results are not reliable because discontinuities results listed by NDT Level 1 personnel depends on their skills and judgments. And the pulse echo ultrasound does not produce visible image or report for record keeping. Thus, modern computed digital radiography which uses imaging plate (IP) has came as an alternative NDT testing of conventional pulse echo ultrasound testing. Computed radiography (CR) being modern digital radiography produces visible radiation images of welding and supports computer, based image processing for image evaluation and discontinuities interpretation. CR technology also supports measurement of wall thickness of the penstock pipe that was remained from corrosion. It also supports double wall double image techniques for the pipes less than 100 mm in outside diameter. Standards and codes for the CR technique have been well developed for its application for pressure vessels such as hydropower, storage tanks, casting products and aluminum products. Finally, this paper illustrates modern CR technology for inspection of penstock pipe used in hydropower for the efficient construction, testing and repairing.
- Open Access
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
A comparative study of point load index and uniaxial compressive strength in anisotropic metamorphic rocks of central Nepal
Point load index strength is a simple parameter for estimating the compressive strength of intact rock. This research examines the impact of foliation orientation on the point load index strength characteristics and failure patterns of foliated metamorphic rocks from the hilly region of Central Nepal, an area that has been the subject of limited study. Rock blocks were collected from three anisotropic metamorphic units: banded gneiss from the Higher Himalayan gneissic complex at Kodari, slate from the Benighat Formation at Sunitar, Hetauda, and metasandstone from the Tistung Formation at Makhubesi, Lalitpur, in the Lesser Himalaya. Core specimens (56.5 mm diameter) were drilled with orientations parallel, inclined, and perpendicular to the foliation planes. Overall, 150 cylindrical specimens were tested for point load strength and uniaxial compressive strength across ten anisotropy angles (β) from 0° to 90°, at 10° intervals, where β is the angle between the loading direction and the foliation plane. The findings revealed that the lowest axial point load test (PLT) values were obtained at β = 30° for all three rock types. The highest PLT values were obtained at β = 50° for banded gneiss, β = 80° for slate, and β = 0° for metasandstone. Analysis of the failure patterns from the axial point load tests identified four primary failure modes: fracture parallel to foliation (PF), fracture across foliation (AF), axial slitting into two cylindrical blocks (AS2), and axial slitting into three cylindrical blocks (AS3).
- 17 September 2026
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 5 (1)
Open AccessA comparative study of point load index and uniaxial compressive strength in anisotropic metamorphic rocks of central Nepal
Point load index strength is a simple parameter for estimating the compressive strength of intact rock. This research examines the impact of foliation orientation on the point load index strength characteristics and failure patterns of foliated metamorphic rocks from the hilly region of Central Nepal, an area that has been the subject of limited study. Rock blocks were collected from three anisotropic metamorphic units: banded gneiss from the Higher Himalayan gneissic complex at Kodari, slate from the Benighat Formation at Sunitar, Hetauda, and metasandstone from the Tistung Formation at Makhubesi, Lalitpur, in the Lesser Himalaya. Core specimens (56.5 mm diameter) were drilled with orientations parallel, inclined, and perpendicular to the foliation planes. Overall, 150 cylindrical specimens were tested for point load strength and uniaxial compressive strength across ten anisotropy angles (β) from 0° to 90°, at 10° intervals, where β is the angle between the loading direction and the foliation plane. The findings revealed that the lowest axial point load test (PLT) values were obtained at β = 30° for all three rock types. The highest PLT values were obtained at β = 50° for banded gneiss, β = 80° for slate, and β = 0° for metasandstone. Analysis of the failure patterns from the axial point load tests identified four primary failure modes: fracture parallel to foliation (PF), fracture across foliation (AF), axial slitting into two cylindrical blocks (AS2), and axial slitting into three cylindrical blocks (AS3).
- Open Access
- 30 November 2025
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 4 (2) , 187-194
Comparative Analysis of Horizontal Axis Wind Turbine Rotors with and without winglet at various wind speeds using Computational Fluid Dynamics Approach
This project investigates the aerodynamic performance of a Horizontal Axis Wind Turbine (HAWT) blade using NREL S-series airfoils (S830, S831, S832) with and without a winglet at various wind speeds. The blade was designed in QBlade and modeled in SolidWorks, with simulations performed in ANSYS Fluent using a steady-state RANS approach and the SST k–ω turbulence model. A winglet was added to the blade tip to assess its effect on performance. The computational domain applied the Multiple Reference Frame (MRF) to simulate rotating effects. Results show that the winglet improves power output by up to 3.55% at low wind speeds, with smaller gains at higher speeds. Comparative torque analyses and mesh-independence tests were performed to validate numerical accuracy. This suggests that winglets help reduce energy losses and improve turbine performance, especially at lower wind speeds.
- 30 November 2025
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 4 (2) , 187-194
Open AccessComparative Analysis of Horizontal Axis Wind Turbine Rotors with and without winglet at various wind speeds using Computational Fluid Dynamics Approach
This project investigates the aerodynamic performance of a Horizontal Axis Wind Turbine (HAWT) blade using NREL S-series airfoils (S830, S831, S832) with and without a winglet at various wind speeds. The blade was designed in QBlade and modeled in SolidWorks, with simulations performed in ANSYS Fluent using a steady-state RANS approach and the SST k–ω turbulence model. A winglet was added to the blade tip to assess its effect on performance. The computational domain applied the Multiple Reference Frame (MRF) to simulate rotating effects. Results show that the winglet improves power output by up to 3.55% at low wind speeds, with smaller gains at higher speeds. Comparative torque analyses and mesh-independence tests were performed to validate numerical accuracy. This suggests that winglets help reduce energy losses and improve turbine performance, especially at lower wind speeds.
- Open Access
- 30 November 2025
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 4 (2) , 154-170
Intrusion Detection System using Clustering, Deep Learning and Feature Reduction Technique
TThis research proposes an intrusion detection system (IDS) leveraging a hybrid machine learning and deep learning approach to enhance multiclass classification accuracy. The study uses the KDD99 dataset, comprising 494,020 instances with 42 features, which undergoes preprocessing steps including label encoding, memory optimization (reducing the data size by 49.99%), and feature scaling using a Standard Scaler. A hybrid feature selection technique combining Select Best and Recursive Feature Elimination (RFE) reduces the feature set from 42 to 15, improving computational efficiency. For clustering, K-means (with optimal *k* determined via the elbow method) and DBSCAN (with epsilon tuning using the knee method) are employed. Performance is evaluated using the Silhouette Score, where K-means achieves the highest score (0.885) with 11 clusters. The clustered data is then classified using an LSTM model, achieving 99.92% accuracy for 5 clusters, 99.86% for 11 clusters, and 99.53% for 22 clusters. The model demonstrates high precision, recall, and F1-scores across all clusters, even for minority attack classes. Comparative analysis with existing methods highlights the superiority of the proposed hybrid feature selection and LSTM-based classification approach. Future work may explore alternative clustering techniques and real-time deployment for enhanced intrusion detection performance
- 30 November 2025
- Published by Nepal Journals Online (JOL) in Journal of Engineering and Sciences
- Vol. 4 (2) , 154-170
Open AccessIntrusion Detection System using Clustering, Deep Learning and Feature Reduction Technique
TThis research proposes an intrusion detection system (IDS) leveraging a hybrid machine learning and deep learning approach to enhance multiclass classification accuracy. The study uses the KDD99 dataset, comprising 494,020 instances with 42 features, which undergoes preprocessing steps including label encoding, memory optimization (reducing the data size by 49.99%), and feature scaling using a Standard Scaler. A hybrid feature selection technique combining Select Best and Recursive Feature Elimination (RFE) reduces the feature set from 42 to 15, improving computational efficiency. For clustering, K-means (with optimal *k* determined via the elbow method) and DBSCAN (with epsilon tuning using the knee method) are employed. Performance is evaluated using the Silhouette Score, where K-means achieves the highest score (0.885) with 11 clusters. The clustered data is then classified using an LSTM model, achieving 99.92% accuracy for 5 clusters, 99.86% for 11 clusters, and 99.53% for 22 clusters. The model demonstrates high precision, recall, and F1-scores across all clusters, even for minority attack classes. Comparative analysis with existing methods highlights the superiority of the proposed hybrid feature selection and LSTM-based classification approach. Future work may explore alternative clustering techniques and real-time deployment for enhanced intrusion detection performance