Semarak International Journal of Public Health and Primary Care
Published by Akademia Baru Publishing
- Scilit
- Biomedical Physics
- Musculoskeletal Disorders
- Wounds & Ulcers
- Palliative Care
- Auditory Loss
- Facilities Management
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 0
- Total Publications
- 0
- Average Citations
- 0.00
- Cited Publications
- 0
- Cited Publications %
- 0%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 2
- Monthly Citation Metric (MCM)
- 0.31
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 0
- Max
- 0
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 14-26
Development and Evaluation of the Inner Peace Meter: A Galvanic Skin Response-Based Stress Monitoring System
Stress is a critical physiological and psychological response that affects individuals across various domains, including healthcare, workplaces, and academic settings. Conventional stress assessment methods, such as self-report surveys and heart rate monitoring, often lack objectivity or require complex instrumentation. This necessitates the development of alternative, non-invasive stress monitoring techniques. This study aims to develop and evaluate a portable Galvanic Skin Response (GSR) sensor prototype for real-time stress monitoring. The device is designed to improve the accuracy and accessibility of stress detection through continuous skin conductance measurements. The Inner Peace Meter prototype was developed using a GSR sensor, an Arduino Uno microcontroller, and LED indicators to visualize stress levels. The system was tested on volunteers under controlled conditions, including relaxation and stress-inducing tasks. A moving average filter was applied to stabilize sensor readings, and calibration was performed to account for individual differences in skin conductivity. The device successfully detected stress fluctuations, with red LEDs indicating heightened stress, green LEDs signaling relaxation, and yellow LEDs representing stable conditions. Quantitative analysis showed a strong correlation between stress-inducing activities and increased GSR readings. Challenges related to environmental factors and individual variability were addressed through calibration and optimized sensor placement. The Inner Peace Meter demonstrates a reliable and cost-effective approach to stress monitoring, with potential applications in mental health, biofeedback therapy, and wearable health technology. Future enhancements, such as smartphone integration and wireless data logging, could further improve usability and expand its practical applications.
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 14-26
Open AccessDevelopment and Evaluation of the Inner Peace Meter: A Galvanic Skin Response-Based Stress Monitoring System
Stress is a critical physiological and psychological response that affects individuals across various domains, including healthcare, workplaces, and academic settings. Conventional stress assessment methods, such as self-report surveys and heart rate monitoring, often lack objectivity or require complex instrumentation. This necessitates the development of alternative, non-invasive stress monitoring techniques. This study aims to develop and evaluate a portable Galvanic Skin Response (GSR) sensor prototype for real-time stress monitoring. The device is designed to improve the accuracy and accessibility of stress detection through continuous skin conductance measurements. The Inner Peace Meter prototype was developed using a GSR sensor, an Arduino Uno microcontroller, and LED indicators to visualize stress levels. The system was tested on volunteers under controlled conditions, including relaxation and stress-inducing tasks. A moving average filter was applied to stabilize sensor readings, and calibration was performed to account for individual differences in skin conductivity. The device successfully detected stress fluctuations, with red LEDs indicating heightened stress, green LEDs signaling relaxation, and yellow LEDs representing stable conditions. Quantitative analysis showed a strong correlation between stress-inducing activities and increased GSR readings. Challenges related to environmental factors and individual variability were addressed through calibration and optimized sensor placement. The Inner Peace Meter demonstrates a reliable and cost-effective approach to stress monitoring, with potential applications in mental health, biofeedback therapy, and wearable health technology. Future enhancements, such as smartphone integration and wireless data logging, could further improve usability and expand its practical applications.
- Open Access
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 40-51
Optimising Breast Ultrasound Image Quality: Impact of Body Mass Index on Breast Carcinoma Detection on Women
Breast carcinoma remains a leading cause of cancer-related mortality among women globally, with early detection being critical for improving prognosis and survival rates. While mammography is widely used for screening, its limitations in young women and those with dense breast tissue have led to the increased use of ultrasound (US) imaging as a complementary tool. However, the quality of breast US images can vary significantly, with body mass index (BMI) emerging as a potential influencing factor. This study investigates the correlation between BMI and breast US image quality, focusing on its implications for breast carcinoma detection in Malaysian women. A prospective observational study was conducted in a hospital in Alor Setar, Kedah, involving 18 female patients with breast lesions classified as Bi-RADS 4 or above. Participants were categorized into normal (18.5–24.9 kg/m²), overweight (25–29.9 kg/m²), and obese (≥30 kg/m²) BMI groups. Breast US images were evaluated for pathology demonstration, spatial resolution, and contrast resolution using a subjective scoring survey assessed by five medical officers. Statistical analysis, including Spearman correlation and Cronbach’s Alpha coefficient, was performed to determine the relationship between BMI and image quality.The results revealed a weak negative correlation between higher BMI and inferior image quality, particularly in obese patients. However, the impact of BMI was not as significant as initially expected, with minimal disparities observed between normal and overweight groups. The normal BMI group achieved superior image quality, attributed to smaller breast volumes and optimal acoustic properties. Overweight patients demonstrated comparable image quality, likely due to adipose tissue acting as an acoustic interface. In contrast, obese patients exhibited the lowest image quality scores, primarily due to increased breast thickness and ultrasound wave attenuation. Despite these challenges, image quality in obese patients remained acceptable for clinical use. The study highlights that while BMI influences breast US image quality, other factors such as breast composition, lesion characteristics, and operator expertise play a more substantial role. Variability in breast tissue density and the skill of the sonographer were identified as critical determinants of image quality. These findings underscore the need for tailored imaging protocols and advanced technologies, such as high-frequency transducers and three-dimensional US, to optimize diagnostic accuracy across all BMI categories.
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 40-51
Open AccessOptimising Breast Ultrasound Image Quality: Impact of Body Mass Index on Breast Carcinoma Detection on Women
Breast carcinoma remains a leading cause of cancer-related mortality among women globally, with early detection being critical for improving prognosis and survival rates. While mammography is widely used for screening, its limitations in young women and those with dense breast tissue have led to the increased use of ultrasound (US) imaging as a complementary tool. However, the quality of breast US images can vary significantly, with body mass index (BMI) emerging as a potential influencing factor. This study investigates the correlation between BMI and breast US image quality, focusing on its implications for breast carcinoma detection in Malaysian women. A prospective observational study was conducted in a hospital in Alor Setar, Kedah, involving 18 female patients with breast lesions classified as Bi-RADS 4 or above. Participants were categorized into normal (18.5–24.9 kg/m²), overweight (25–29.9 kg/m²), and obese (≥30 kg/m²) BMI groups. Breast US images were evaluated for pathology demonstration, spatial resolution, and contrast resolution using a subjective scoring survey assessed by five medical officers. Statistical analysis, including Spearman correlation and Cronbach’s Alpha coefficient, was performed to determine the relationship between BMI and image quality.The results revealed a weak negative correlation between higher BMI and inferior image quality, particularly in obese patients. However, the impact of BMI was not as significant as initially expected, with minimal disparities observed between normal and overweight groups. The normal BMI group achieved superior image quality, attributed to smaller breast volumes and optimal acoustic properties. Overweight patients demonstrated comparable image quality, likely due to adipose tissue acting as an acoustic interface. In contrast, obese patients exhibited the lowest image quality scores, primarily due to increased breast thickness and ultrasound wave attenuation. Despite these challenges, image quality in obese patients remained acceptable for clinical use. The study highlights that while BMI influences breast US image quality, other factors such as breast composition, lesion characteristics, and operator expertise play a more substantial role. Variability in breast tissue density and the skill of the sonographer were identified as critical determinants of image quality. These findings underscore the need for tailored imaging protocols and advanced technologies, such as high-frequency transducers and three-dimensional US, to optimize diagnostic accuracy across all BMI categories.
- Open Access
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 52-58
Radiation Doses from Computed Tomography of The Brain Based on Head Sizes in A Diagnostic Center in Northern Nigeria
The study aims to evaluate and assess radiation dose and its relationship with the effective diameter of the head for CT brain examinations conducted using a 16 multi-slice CT scanning machine. Data from 30 patients who had CT brain examinations done at our facility was retrospectively collected in the month of May 2024. Data, including the volume Computed Tomography Dose Index (CTDIvol) value, dose-length product (DLP) value, scan range and the head diameter of the patient measured in the Antero-posterior (AP) and Lateral (LAT) orientations, were documented in a standardized format for analysis. The effective dosage E was then calculated. The mean ± S.D of E for brain CT was 2.5 ± 0.5 mSv. The mean ± S.D for the Effective Diameter DEFF was documented as 159.9 ± 8.7. The correlation (R2) between the E and DEFF showed 0.3315 as its values, indicating a positive correlation. The radiation increases according to the increase in head diameter. This study demonstrates that radiation exposures from CT brain scans may rely on the size of the head. Consequently, additional safety protocols should be implemented for the type of examination so as to reduce the potential risks linked to CT scans.
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 52-58
Open AccessRadiation Doses from Computed Tomography of The Brain Based on Head Sizes in A Diagnostic Center in Northern Nigeria
The study aims to evaluate and assess radiation dose and its relationship with the effective diameter of the head for CT brain examinations conducted using a 16 multi-slice CT scanning machine. Data from 30 patients who had CT brain examinations done at our facility was retrospectively collected in the month of May 2024. Data, including the volume Computed Tomography Dose Index (CTDIvol) value, dose-length product (DLP) value, scan range and the head diameter of the patient measured in the Antero-posterior (AP) and Lateral (LAT) orientations, were documented in a standardized format for analysis. The effective dosage E was then calculated. The mean ± S.D of E for brain CT was 2.5 ± 0.5 mSv. The mean ± S.D for the Effective Diameter DEFF was documented as 159.9 ± 8.7. The correlation (R2) between the E and DEFF showed 0.3315 as its values, indicating a positive correlation. The radiation increases according to the increase in head diameter. This study demonstrates that radiation exposures from CT brain scans may rely on the size of the head. Consequently, additional safety protocols should be implemented for the type of examination so as to reduce the potential risks linked to CT scans.
- Open Access
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 1-13
Comparison between Size-Specific Dose Estimate (SSDE) Based on Water Equivalent Diameter and Effective Dose in Adult Computed Tomography (CT) Thorax, Abdomen and Pelvis (TAP)
Computed Tomography (CT) scan examination the most predominant source of medical radiation exposure towards patients globally contributing to 44% of the global effective radiation dose. In Malaysia, the prevalent usage of CT scans to aid diagnostic procedures among patients have raised concerns about the impacts of increasing use of ionizing radiation for diagnosis. This study compares the patient effective dose (ED) and the patient size specific dose estimate based on water equivalent diameter (SSDE Dw) in CT Thorax-Abdomen-Pelvis (TAP) procedure.A prospective study was conducted at a hospital in Wilayah Persekutuan Kuala Lumpur. The study utilized the 128-slice Siemens SOMATOM Definition Dual Source CT scanner. Study parameters of: CTDIvol, DLP, patient antero-posterior (AP) and lateral (LAT) diameter were retrieved from Picture Archiving and Communications System (PACS) for calculations of patient effective diameter, effective dose and SSDE Dw for each respective patient involved in the study. The data obtained were numerically coded and analyzed using SPSS version 29 for Windows 11. Independent T-Test was employed to compare the difference between the means of patient effective dose and SSDE Dw.The results revealed a significant difference between values of patient effective dose and SSDE Dw among patients undergoing CT TAP procedure. The calculated patient effective dose for CT TAP imaging procedure were 11.15 ± 3.3 mSv. The SSDE Dw values in patients who underwent CT TAP imaging procedure were 16.54 ± 3.2 mGy.The radiation dose calculation purely based on effective dose for CT TAP procedure will result in underestimation of patient radiation dose as compared to calculation of patient radiation dose using SSDE Dw. Future study should consider a larger sample size with inclusion of multiple healthcare institutions around Malaysia and a more advance and accurate calculation method for patient radiation dose.
- 30 June 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 4 (1) , 1-13
Open AccessComparison between Size-Specific Dose Estimate (SSDE) Based on Water Equivalent Diameter and Effective Dose in Adult Computed Tomography (CT) Thorax, Abdomen and Pelvis (TAP)
Computed Tomography (CT) scan examination the most predominant source of medical radiation exposure towards patients globally contributing to 44% of the global effective radiation dose. In Malaysia, the prevalent usage of CT scans to aid diagnostic procedures among patients have raised concerns about the impacts of increasing use of ionizing radiation for diagnosis. This study compares the patient effective dose (ED) and the patient size specific dose estimate based on water equivalent diameter (SSDE Dw) in CT Thorax-Abdomen-Pelvis (TAP) procedure.A prospective study was conducted at a hospital in Wilayah Persekutuan Kuala Lumpur. The study utilized the 128-slice Siemens SOMATOM Definition Dual Source CT scanner. Study parameters of: CTDIvol, DLP, patient antero-posterior (AP) and lateral (LAT) diameter were retrieved from Picture Archiving and Communications System (PACS) for calculations of patient effective diameter, effective dose and SSDE Dw for each respective patient involved in the study. The data obtained were numerically coded and analyzed using SPSS version 29 for Windows 11. Independent T-Test was employed to compare the difference between the means of patient effective dose and SSDE Dw.The results revealed a significant difference between values of patient effective dose and SSDE Dw among patients undergoing CT TAP procedure. The calculated patient effective dose for CT TAP imaging procedure were 11.15 ± 3.3 mSv. The SSDE Dw values in patients who underwent CT TAP imaging procedure were 16.54 ± 3.2 mGy.The radiation dose calculation purely based on effective dose for CT TAP procedure will result in underestimation of patient radiation dose as compared to calculation of patient radiation dose using SSDE Dw. Future study should consider a larger sample size with inclusion of multiple healthcare institutions around Malaysia and a more advance and accurate calculation method for patient radiation dose.
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 2 (1) , 45-58
Assessing Acute Kidney Injury Risk in Cancer Patients Undergoing Surgery: Insights from a Public Teaching Hospital in Kuala Lumpur
Acute Kidney Injury (AKI) is a critical complication among cancer patients undergoing surgical interventions. This study aimed to assess the association between patients with malignancy/ tumour and the risk of AKI in the surgical department of a public teaching hospital in Kuala Lumpur. The prospective observational study included 193 patients and involved seventy-five surgical nurses who underwent an AKI nursing risk assessment education program. Utilizing the Nursing Risk Assessment of Acute Kidney Injury (NURA-AKI) tool, the risk assessments were conducted from July to December 2022. The data was collected during three distinct assessment phases. Results showed AKI risk factors among surgical patients include age > 65 years (40.9%), male gender (58.5%), comorbidities like hypertension (56.5%), DM (43.5%), malignancy/ tumors 20.7% of patients, infection/sepsis at 22.8% and least patients with CKD were 11.9%, chronic liver 7.3% and hypotension 6.2%. The risk of AKI clinical parameters such as elevated serum creatinine (34.2%), blood loss/dehydration (25.4%), and low hemoglobin levels (23.3%). Patients with malignancy/ tumour had elective surgeries 43.5%, emergency surgeries 32.6%, meanwhile, 36.8% of patients consumed nephrotoxic agents. The Chi-square test was used to analyze the association between patients with malignancy/ tumour and the risk factors of AKI in the surgical department HCTM. There was a significant association between patients with malignancy/ tumour and the risk factors of AKI and the patients admitted to the different units in surgical department (p < 0.05). The general surgery and urology ward reported more than 40% of patients had malignancy/ tumour. However, there was no significant association between AKI risk factor consuming nephrotoxin agent and AKI risk factor surgery within patients had malignancy/ tumour with AKI risk (p-value> 0.05). The results demonstrate the prevalence of AKI among cancer patients in the surgical setting, identifying key risk factors and informing strategies for early detection and prevention
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 2 (1) , 45-58
Open AccessAssessing Acute Kidney Injury Risk in Cancer Patients Undergoing Surgery: Insights from a Public Teaching Hospital in Kuala Lumpur
Acute Kidney Injury (AKI) is a critical complication among cancer patients undergoing surgical interventions. This study aimed to assess the association between patients with malignancy/ tumour and the risk of AKI in the surgical department of a public teaching hospital in Kuala Lumpur. The prospective observational study included 193 patients and involved seventy-five surgical nurses who underwent an AKI nursing risk assessment education program. Utilizing the Nursing Risk Assessment of Acute Kidney Injury (NURA-AKI) tool, the risk assessments were conducted from July to December 2022. The data was collected during three distinct assessment phases. Results showed AKI risk factors among surgical patients include age > 65 years (40.9%), male gender (58.5%), comorbidities like hypertension (56.5%), DM (43.5%), malignancy/ tumors 20.7% of patients, infection/sepsis at 22.8% and least patients with CKD were 11.9%, chronic liver 7.3% and hypotension 6.2%. The risk of AKI clinical parameters such as elevated serum creatinine (34.2%), blood loss/dehydration (25.4%), and low hemoglobin levels (23.3%). Patients with malignancy/ tumour had elective surgeries 43.5%, emergency surgeries 32.6%, meanwhile, 36.8% of patients consumed nephrotoxic agents. The Chi-square test was used to analyze the association between patients with malignancy/ tumour and the risk factors of AKI in the surgical department HCTM. There was a significant association between patients with malignancy/ tumour and the risk factors of AKI and the patients admitted to the different units in surgical department (p < 0.05). The general surgery and urology ward reported more than 40% of patients had malignancy/ tumour. However, there was no significant association between AKI risk factor consuming nephrotoxin agent and AKI risk factor surgery within patients had malignancy/ tumour with AKI risk (p-value> 0.05). The results demonstrate the prevalence of AKI among cancer patients in the surgical setting, identifying key risk factors and informing strategies for early detection and prevention
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 2 (1) , 20-27
Translation, Adaptation, and Integration of the Automated Method for Testing Auditory Sensitivity (AMTAS) instructional video in Malay
The growing demand for hearing healthcare services in Malaysia, aggravated by a shortage of audiologists, underscores the need for alternative solutions like automated hearing assessment tools. The Automated Method for Testing Auditory Sensitivity (AMTAS), a widely recognized system internationally, has not yet been adapted for use in Malaysia. This study aimed to translate and validate the AMTAS instructional video into Bahasa Malaysia, enabling its application among the local population. The verbatim translation approach ensured word-for-word accuracy to maintain instructional integrity. The translated content was incorporated into the AMTAS system, providing clearer instructions for Malaysian users. The methodology involved a multi-step process: transcription of the original video, translation into Malay, and final review by language experts. Results indicated that the Malay version of the instructional video improves accessibility, leading to enhanced user comfort and response accuracy. This initiative addresses the language barrier in hearing assessments and contributes to expanding AMTAS usability in Malaysia. In conclusion, the translated video can facilitate better hearing assessments, particularly in rural and underserved communities, potentially improving audiology services nationwide.
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 2 (1) , 20-27
Open AccessTranslation, Adaptation, and Integration of the Automated Method for Testing Auditory Sensitivity (AMTAS) instructional video in Malay
The growing demand for hearing healthcare services in Malaysia, aggravated by a shortage of audiologists, underscores the need for alternative solutions like automated hearing assessment tools. The Automated Method for Testing Auditory Sensitivity (AMTAS), a widely recognized system internationally, has not yet been adapted for use in Malaysia. This study aimed to translate and validate the AMTAS instructional video into Bahasa Malaysia, enabling its application among the local population. The verbatim translation approach ensured word-for-word accuracy to maintain instructional integrity. The translated content was incorporated into the AMTAS system, providing clearer instructions for Malaysian users. The methodology involved a multi-step process: transcription of the original video, translation into Malay, and final review by language experts. Results indicated that the Malay version of the instructional video improves accessibility, leading to enhanced user comfort and response accuracy. This initiative addresses the language barrier in hearing assessments and contributes to expanding AMTAS usability in Malaysia. In conclusion, the translated video can facilitate better hearing assessments, particularly in rural and underserved communities, potentially improving audiology services nationwide.
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 3 (1) , 69-81
Transforming Nursing Education: Evaluating Knowledge and Practices in Pressure Ulcer Prevention among Undergraduate Nursing Students at the International Islamic University Malaysia (IIUM)
Pressure ulcers are a significant concern in healthcare settings, particularly for immobile patients. Nursing students play a key role in preventing these injuries, making their preparedness essential for improved patient outcomes. Gaps in the practical application of pressure ulcer prevention knowledge among nursing students may hinder their clinical effectiveness. This study assessed the knowledge and practices of undergraduate nursing students at the International Islamic University Malaysia (IIUM), Kuantan Campus, regarding pressure ulcer prevention. A cross-sectional study was conducted using the Pieper-Zulkowski Pressure Ulcer Knowledge Test (PZ-PUKT) 2016 questionnaire. Convenience sampling was used to recruit 160 students. Data were analysed using SPSS version 27. Of the participants (response rate: 70.48%), 71.25% demonstrated high knowledge, but only 16.25% achieved satisfactory practice scores, with poor practice observed in 83.75%. There was no significant association between the year of study and knowledge or practice levels. Conclusion: These findings highlight the need for improved practical training and curricular enhancements to align theoretical knowledge with clinical practice in pressure ulcer prevention.
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 3 (1) , 69-81
Open AccessTransforming Nursing Education: Evaluating Knowledge and Practices in Pressure Ulcer Prevention among Undergraduate Nursing Students at the International Islamic University Malaysia (IIUM)
Pressure ulcers are a significant concern in healthcare settings, particularly for immobile patients. Nursing students play a key role in preventing these injuries, making their preparedness essential for improved patient outcomes. Gaps in the practical application of pressure ulcer prevention knowledge among nursing students may hinder their clinical effectiveness. This study assessed the knowledge and practices of undergraduate nursing students at the International Islamic University Malaysia (IIUM), Kuantan Campus, regarding pressure ulcer prevention. A cross-sectional study was conducted using the Pieper-Zulkowski Pressure Ulcer Knowledge Test (PZ-PUKT) 2016 questionnaire. Convenience sampling was used to recruit 160 students. Data were analysed using SPSS version 27. Of the participants (response rate: 70.48%), 71.25% demonstrated high knowledge, but only 16.25% achieved satisfactory practice scores, with poor practice observed in 83.75%. There was no significant association between the year of study and knowledge or practice levels. Conclusion: These findings highlight the need for improved practical training and curricular enhancements to align theoretical knowledge with clinical practice in pressure ulcer prevention.
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 3 (1) , 82-97
Angle-Of-Pull (AOP) Resistor Point Locator Prototype for Application in Physiotherapy
The increasing prevalence of musculoskeletal disorders necessitates the development of precise and user-friendly tools in physiotherapy to improve rehabilitation outcomes. Traditional methods for determining the Angle of Pull (AOP) and locating resistance points in clinical settings often lack accuracy and accessibility. To address this issue, this study introduces the Angle Assist (A²) device, aimed at enhancing the precision and effectiveness of rehabilitation exercises by accurately identifying the resistance point where the line of pull generates maximal muscle torque. The primary objective of this research was to design and develop a prototype for an AOP resistor point locator equipped with a precise angle reading display, aimed at reducing the time required to determine the AOP and pinpoint the resistance point by at least 10%. The methodology involved the integration of an MPU6050 sensor, an OLED display, and laser pointers, all controlled by customized firmware. The device was subjected to a series of tests, including accuracy, reliability and time improvement test. The results demonstrate that the A² device achieves high accuracy, with an R² value of 0.9991 when compared to true angles. Additionally, the device exceeded the initial objective by reducing the time required to determine the AOP and pinpoint the resistance point by 16.92%. In conclusion, the A² device represents a significant advancement in physiotherapy practices by providing precise angle measurements and improving the accuracy of resistance point placement.
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 3 (1) , 82-97
Open AccessAngle-Of-Pull (AOP) Resistor Point Locator Prototype for Application in Physiotherapy
The increasing prevalence of musculoskeletal disorders necessitates the development of precise and user-friendly tools in physiotherapy to improve rehabilitation outcomes. Traditional methods for determining the Angle of Pull (AOP) and locating resistance points in clinical settings often lack accuracy and accessibility. To address this issue, this study introduces the Angle Assist (A²) device, aimed at enhancing the precision and effectiveness of rehabilitation exercises by accurately identifying the resistance point where the line of pull generates maximal muscle torque. The primary objective of this research was to design and develop a prototype for an AOP resistor point locator equipped with a precise angle reading display, aimed at reducing the time required to determine the AOP and pinpoint the resistance point by at least 10%. The methodology involved the integration of an MPU6050 sensor, an OLED display, and laser pointers, all controlled by customized firmware. The device was subjected to a series of tests, including accuracy, reliability and time improvement test. The results demonstrate that the A² device achieves high accuracy, with an R² value of 0.9991 when compared to true angles. Additionally, the device exceeded the initial objective by reducing the time required to determine the AOP and pinpoint the resistance point by 16.92%. In conclusion, the A² device represents a significant advancement in physiotherapy practices by providing precise angle measurements and improving the accuracy of resistance point placement.
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 1 (1) , 1-15
Integrating HIRARC and Fault Tree Analysis (FTA) for Comprehensive Work Health and Safety Assessment in a Wood Industry Workshop
The wood business is inherently dangerous, with workers frequently exposed to hazards such as mechanical breakdowns, chemical exposures, and ergonomic strains. Ensuring the safety and health of workers in such circumstances is critical. The objective of this study is to identify the potential risks associated with each occupation, determine the underlying causes of workplace accidents, and subsequently propose recommendations for enhancing safety. This study provides a thorough examination of occupational health and safety in a wood industry workshop, employing the HIRARC (Hazard Identification, Risk Assessment, and Risk Control) approach and the Fault Tree Analysis method (FTA). The investigation commences by methodically analysing potential dangers that may be present in the workshop, encompassing physical, chemical, fire, noise, ergonomic, electrical, and environmental threats. A comprehensive risk assessment is performed to evaluate the probability and magnitude of these dangers, with them being categorised based on their levels of risk. The findings emphasise areas of elevated risk, specifically the use of machinery, manual handling, and exposure to wood dust and chemicals. Next, risk management strategies are suggested to reduce the highlighted dangers, with the significance of engineering controls, administrative controls, and personal protective equipment (PPE) being highlighted. The measures include the installation of machine guards, improved ventilation systems, ergonomic workstation design, comprehensive safety training programmes, and regular maintenance schedules. The HIRARC method's systematic approach to identifying and addressing workplace dangers demonstrates its efficacy, ultimately resulting in a more secure work environment. The findings of this study are useful for industry practitioners and safety managers seeking to improve occupational health and safety standards in wood industry workshops. Future research directions include continual monitoring of existing safety measures and the use of enhanced safety technologies.
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 1 (1) , 1-15
Open AccessIntegrating HIRARC and Fault Tree Analysis (FTA) for Comprehensive Work Health and Safety Assessment in a Wood Industry Workshop
The wood business is inherently dangerous, with workers frequently exposed to hazards such as mechanical breakdowns, chemical exposures, and ergonomic strains. Ensuring the safety and health of workers in such circumstances is critical. The objective of this study is to identify the potential risks associated with each occupation, determine the underlying causes of workplace accidents, and subsequently propose recommendations for enhancing safety. This study provides a thorough examination of occupational health and safety in a wood industry workshop, employing the HIRARC (Hazard Identification, Risk Assessment, and Risk Control) approach and the Fault Tree Analysis method (FTA). The investigation commences by methodically analysing potential dangers that may be present in the workshop, encompassing physical, chemical, fire, noise, ergonomic, electrical, and environmental threats. A comprehensive risk assessment is performed to evaluate the probability and magnitude of these dangers, with them being categorised based on their levels of risk. The findings emphasise areas of elevated risk, specifically the use of machinery, manual handling, and exposure to wood dust and chemicals. Next, risk management strategies are suggested to reduce the highlighted dangers, with the significance of engineering controls, administrative controls, and personal protective equipment (PPE) being highlighted. The measures include the installation of machine guards, improved ventilation systems, ergonomic workstation design, comprehensive safety training programmes, and regular maintenance schedules. The HIRARC method's systematic approach to identifying and addressing workplace dangers demonstrates its efficacy, ultimately resulting in a more secure work environment. The findings of this study are useful for industry practitioners and safety managers seeking to improve occupational health and safety standards in wood industry workshops. Future research directions include continual monitoring of existing safety measures and the use of enhanced safety technologies.
- Open Access
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 1 (1) , 37-45
Obesity, Eating Habits, and Physical Activity before and during Covid-19 Pandemic among University Lecturers
The COVID-19 pandemic has caused significant changes to the lives of individuals around the world. Malaysia has implemented restrictions as response to the pandemic and the effects are felt by all parties, including lecturers. This study aims to investigate the impact of the lockdown on the prevalence of obesity, body weight, physical activity and eating habits of university lecturers in Malaysia. A self-reported questionnaire was distributed to lecturers of different universities in Malaysia. The questionnaire involves 2 main sections. The first section records the participants’ physical activity level before and during the pandemic while the second section records the changes in eating habits. 323 eligible responses were analyzed, 13.9% of participants were obese and 27.6 were overweight before the pandemic. Significant weight change was recorded as the mean weight increased by 0.57 ± 0.56 kg during the pandemic. Physical activity level decreased from 1.67 ± 0.17 to 1.60 ± 0.17 and changes in eating habits were also observed. Weight change was significantly associated with physical activity, total food intake, sweetened products and confectionery intake, salty snacks, fast food and sweet drinks intake. Prevalence of obesity increased slightly but changes were not significant. The prevalence of obesity is worrying among university lecturers in Malaysia. Interventions should be implemented to improve the current situation. Significant weight gain and PAL decrease was recorded during the COVID-19 pandemic. Weight gain was associated with the decrease in physical activity and the increased consumption of unhealthy foods.
- 13 May 2025
- Published by Akademia Baru Publishing in Semarak International Journal of Public Health and Primary Care
- Vol. 1 (1) , 37-45
Open AccessObesity, Eating Habits, and Physical Activity before and during Covid-19 Pandemic among University Lecturers
The COVID-19 pandemic has caused significant changes to the lives of individuals around the world. Malaysia has implemented restrictions as response to the pandemic and the effects are felt by all parties, including lecturers. This study aims to investigate the impact of the lockdown on the prevalence of obesity, body weight, physical activity and eating habits of university lecturers in Malaysia. A self-reported questionnaire was distributed to lecturers of different universities in Malaysia. The questionnaire involves 2 main sections. The first section records the participants’ physical activity level before and during the pandemic while the second section records the changes in eating habits. 323 eligible responses were analyzed, 13.9% of participants were obese and 27.6 were overweight before the pandemic. Significant weight change was recorded as the mean weight increased by 0.57 ± 0.56 kg during the pandemic. Physical activity level decreased from 1.67 ± 0.17 to 1.60 ± 0.17 and changes in eating habits were also observed. Weight change was significantly associated with physical activity, total food intake, sweetened products and confectionery intake, salty snacks, fast food and sweet drinks intake. Prevalence of obesity increased slightly but changes were not significant. The prevalence of obesity is worrying among university lecturers in Malaysia. Interventions should be implemented to improve the current situation. Significant weight gain and PAL decrease was recorded during the COVID-19 pandemic. Weight gain was associated with the decrease in physical activity and the increased consumption of unhealthy foods.