Anti-Corrosion Manual
Published by Emerald Publishing
- Scilit
- Total Citations
- 0
- Total Publications
- 0
- Average Citations
- 0.00
- Cited Publications
- 0
- Cited Publications %
- 0%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 0
- Monthly Citation Metric (MCM)
- 0
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 0
- Max
- 0
- Citing Source Titles
- Citing Publishers
Latest Publications
- 1 October 1993
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 40 (10) , 9-13
Development of a mathematical treatment for electrochemical impedance data obtained from coated metals: Part 2
Mathematical correlations For obtaining the described parameters, the general model of equivalent circuit used in studying painted metals must be simplified. Within a determined range of high enough frequencies the impedance afforded by Cm is small, therefore, the simplified circuit is reduced as shown in Fig. 18.
- 1 October 1993
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 40 (10) , 9-13
Development of a mathematical treatment for electrochemical impedance data obtained from coated metals: Part 2
Mathematical correlations For obtaining the described parameters, the general model of equivalent circuit used in studying painted metals must be simplified. Within a determined range of high enough frequencies the impedance afforded by Cm is small, therefore, the simplified circuit is reduced as shown in Fig. 18.
- 1 September 1992
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 39 (9) , 4-6
CR12 steels for the coal industry
Over the last 25 years stainless steels have rapidly become accepted as a suitable material for coal processing, handling and transportation systems due to their fractional maintenance costs, improved operational efficiency and favourable life cycle costs. The introduction of a new generation of utility ferritic stainless steels with superior structural rigidity now also means that such steels offer significant savings over carbon steels for coal plant construction because they require less material.
- 1 September 1992
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 39 (9) , 4-6
CR12 steels for the coal industry
Over the last 25 years stainless steels have rapidly become accepted as a suitable material for coal processing, handling and transportation systems due to their fractional maintenance costs, improved operational efficiency and favourable life cycle costs. The introduction of a new generation of utility ferritic stainless steels with superior structural rigidity now also means that such steels offer significant savings over carbon steels for coal plant construction because they require less material.
- 1 March 1992
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 39 (3) , 4-7
Effect of 4-benzylidene, 3-methyl. 5-oxo-1-phenyl phyrazoline derivatives on the corrosion of aluminium in HC1 solutions
The effect of some pyrazoline derivatives as inhibitors on the dissolution of A1 in 2 mol.L−1 HC1 has been studied by weight-loss, galvanostatic polarization, polarographic and scanning electron microscopy methods. Additions of Cu2+ Co2+ or Ni2+ ions increases the efficiency of the inhibitors.
- 1 March 1992
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 39 (3) , 4-7
Effect of 4-benzylidene, 3-methyl. 5-oxo-1-phenyl phyrazoline derivatives on the corrosion of aluminium in HC1 solutions
The effect of some pyrazoline derivatives as inhibitors on the dissolution of A1 in 2 mol.L−1 HC1 has been studied by weight-loss, galvanostatic polarization, polarographic and scanning electron microscopy methods. Additions of Cu2+ Co2+ or Ni2+ ions increases the efficiency of the inhibitors.
- 1 December 1991
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 38 (12) , 4-6
Inhibition of pitting corrosion of Pb in alkaline chlorate and perchlorate solutions by some inorganic anions
The potentiodynamic anodic polarization curves for the lead electrode were obtained in 0.1 mol L-1 KOH solution in the absence and presence of C103- or C104- as aggressive ions at different concentrations. Lower concentrations of these ions have no significant influence on the passive film, while higher concentrations raise the active dissolution current density, and cause destruction of passivity and initiation of pitting corrosion. The critical pitting corrosion potential varies with the concentration of the aggressive ions according to sigmoidal curves. These curves were explained on the basis of the formation of passivitable, active and continuously propagagting pits depending on the range of the aggressive ion concentration. Additions of increasing concentrations of chromate, phosphate, sulphate and carbonate ions cause a shift of the critical pitting potential in the noble direction accounting for increase resistance to pitting attack (inhibition). The pitting corrosion potential varies with the concentration of the inhibitive ions, in the presence of a constant concentration of the aggressive ions, according to curves of sigmoidal shape. From these curves one can determine the minimum concentration of the inhibitive ions necessary for inhibition of pitting corrosion to occur.
- 1 December 1991
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 38 (12) , 4-6
Inhibition of pitting corrosion of Pb in alkaline chlorate and perchlorate solutions by some inorganic anions
The potentiodynamic anodic polarization curves for the lead electrode were obtained in 0.1 mol L-1 KOH solution in the absence and presence of C103- or C104- as aggressive ions at different concentrations. Lower concentrations of these ions have no significant influence on the passive film, while higher concentrations raise the active dissolution current density, and cause destruction of passivity and initiation of pitting corrosion. The critical pitting corrosion potential varies with the concentration of the aggressive ions according to sigmoidal curves. These curves were explained on the basis of the formation of passivitable, active and continuously propagagting pits depending on the range of the aggressive ion concentration. Additions of increasing concentrations of chromate, phosphate, sulphate and carbonate ions cause a shift of the critical pitting potential in the noble direction accounting for increase resistance to pitting attack (inhibition). The pitting corrosion potential varies with the concentration of the inhibitive ions, in the presence of a constant concentration of the aggressive ions, according to curves of sigmoidal shape. From these curves one can determine the minimum concentration of the inhibitive ions necessary for inhibition of pitting corrosion to occur.
- 1 October 1991
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 38 (10) , 19-21
Guide to plastic piping
A newly upgraded and expanded guide provides chemical resistance ratings for most fluids handled by plastic lined piping products.
- 1 October 1991
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 38 (10) , 19-21
Guide to plastic piping
A newly upgraded and expanded guide provides chemical resistance ratings for most fluids handled by plastic lined piping products.
- 1 June 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (6) , 10-11
Reference half cells for monitoring corrosion condition of steel in reinforced concrete structures
Use of half cell potential for monitoring corrosion condition of steel in concrete structures is a well established technique. It is known that once any external sign of corrosion appears on the concrete, a fairly major repair is necessary. It follows that any method of non-destructively ascertaining the probability that reinforcement is corroding at an early stage as possible, must be of a great use to engineers. The half cell technique does just this, and when used with other test methods allows a more complete picture of sick structures to be perceived. Moreover, commissioning a particular cathodic protection (CP) criterion for protecting steel in concrete structures rely on half cell potential technique. Thus the importance of corrosion detection and corrosion inhibition (CP) necessitates the selection of suitable half cells.
- 1 June 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (6) , 10-11
Reference half cells for monitoring corrosion condition of steel in reinforced concrete structures
Use of half cell potential for monitoring corrosion condition of steel in concrete structures is a well established technique. It is known that once any external sign of corrosion appears on the concrete, a fairly major repair is necessary. It follows that any method of non-destructively ascertaining the probability that reinforcement is corroding at an early stage as possible, must be of a great use to engineers. The half cell technique does just this, and when used with other test methods allows a more complete picture of sick structures to be perceived. Moreover, commissioning a particular cathodic protection (CP) criterion for protecting steel in concrete structures rely on half cell potential technique. Thus the importance of corrosion detection and corrosion inhibition (CP) necessitates the selection of suitable half cells.
- 1 May 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (5) , 14-17
Durr paint plant at Rolls Royce Motor Cars
On a ‘green field’ site adjacent to the existing paint shop at Rolls-Royce Motor Cars in Crewe, Durr has erected a new 66,000 sq ft building, complete with services, in which they have installed a new pretreatment and paint finishing line for Rolls-Royce and Bentley cars. The plant entered service in July 1989.
- 1 May 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (5) , 14-17
Durr paint plant at Rolls Royce Motor Cars
On a ‘green field’ site adjacent to the existing paint shop at Rolls-Royce Motor Cars in Crewe, Durr has erected a new 66,000 sq ft building, complete with services, in which they have installed a new pretreatment and paint finishing line for Rolls-Royce and Bentley cars. The plant entered service in July 1989.
- 1 May 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (5) , 4-5
Dry and wet blasting processes increase in popularity report Abrasive Developments
More and more companies are turning to their dry and wet blasting surface treatments say West Midlands based specialists Abrasive Developments.
- 1 May 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (5) , 4-5
Dry and wet blasting processes increase in popularity report Abrasive Developments
More and more companies are turning to their dry and wet blasting surface treatments say West Midlands based specialists Abrasive Developments.
- 1 April 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (4) , 12-14
Chemical reactions in fluxes for hot dip galvanizing
In the hot dip galvanizing process two different fluxes are used to remove the zinc oxide layer, always present on the liquid zinc surface. When this oxide layer, which contains also aluminium oxide, is dragged into the zinc by the articles, interfering the reaction zinc-iron. In former days a flux floating on a part of the liquid zinc surface was rather common, at present this wet flux is almost completely replaced by the dry galvanizing process. Since the chemical reactions taking place in the wet flux, partly take place in the flux for dry galvanizing too, first this wet flux will be discussed in brief.
- 1 April 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (4) , 12-14
Chemical reactions in fluxes for hot dip galvanizing
In the hot dip galvanizing process two different fluxes are used to remove the zinc oxide layer, always present on the liquid zinc surface. When this oxide layer, which contains also aluminium oxide, is dragged into the zinc by the articles, interfering the reaction zinc-iron. In former days a flux floating on a part of the liquid zinc surface was rather common, at present this wet flux is almost completely replaced by the dry galvanizing process. Since the chemical reactions taking place in the wet flux, partly take place in the flux for dry galvanizing too, first this wet flux will be discussed in brief.
- 1 March 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (3) , 4-8
Carboxylic acids as corrosion inhibitors for aluminium in acidic and alkaline solutions
Inhibition of carboxylic acids of aluminium corrosion in hydrochloric acid and sodium hydroxide solutions has been studied using weight-loss and hydrogen evolution methods. The order of inhibition action of aromatic acids depends on the number and position of the carboxylic groups and the other substituents in the benzene ring. Increase of the chain length increases the inhibiting power of aliphatic acids. The inhibition efficiency in NaOH is higher than that in HCI solutions. The action of inhibition was discussed in terms of the chemical structure of the inhibitors.
- 1 March 1990
- Published by Emerald Publishing in Anti-Corrosion Manual
- Vol. 37 (3) , 4-8
Carboxylic acids as corrosion inhibitors for aluminium in acidic and alkaline solutions
Inhibition of carboxylic acids of aluminium corrosion in hydrochloric acid and sodium hydroxide solutions has been studied using weight-loss and hydrogen evolution methods. The order of inhibition action of aromatic acids depends on the number and position of the carboxylic groups and the other substituents in the benzene ring. Increase of the chain length increases the inhibiting power of aliphatic acids. The inhibition efficiency in NaOH is higher than that in HCI solutions. The action of inhibition was discussed in terms of the chemical structure of the inhibitors.