Respiratory Care Reports
Published by SAGE Publications
- Scilit
- Respiratory Support
- Patient Care
- Palliative Care
- Neurodegenerative Disorders
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 0
- Total Publications
- 0
- Average Citations
- 0.00
- Cited Publications
- 0
- Cited Publications %
- 0%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 0
- Monthly Citation Metric (MCM)
- 0
- Q1
- 0
- Med
- 0
- Q3
- 0
- 99%
- 0
- Max
- 0
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 26 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Environmental sustainability in respiratory care: An RT-led PDSA-S approach
- 26 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessEnvironmental sustainability in respiratory care: An RT-led PDSA-S approach
- Open Access
- 25 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Methacholine challenge testing: How I do it
- 25 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessMethacholine challenge testing: How I do it
- Open Access
- 17 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Evidence implemented, outcomes unknown: Advancing outcome accountability in respiratory therapy
- 17 November 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessEvidence implemented, outcomes unknown: Advancing outcome accountability in respiratory therapy
- Open Access
- 30 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
An exploration of perceptions of U.S.-based respiratory care department leaders regarding advanced degrees among their clinical staff
Background: Though the skill set and scope of practice for respiratory therapists (RT) have expanded over the years, the minimum degree required for entry into practice has remained at the associate-degree level. Respiratory department leadership set the tone for hiring preferences and education expectations for their staff. The purpose of this study is to understand the perceptions of RT department managers/directors regarding RTs with advanced degrees (bachelor’s or higher). Methods: Twenty virtual semi-structured interviews with RT department leaders from across the United States were conducted between February and March 2026. Transcripts were coded by four investigators and analyzed for themes. Results: Of the 20 participants, 12 were department managers and 8 were directors. Nine were female and 11 were male. There was near-equal distribution across the four demographic regions. Nine participants reported having earned the AARC Apex designation for Acute Care facilities. Interview questions were categorized into five content areas: (1) Value and Perception of RT, (2) Impact of Advanced Degrees, (3) Leadership and Career Advancement, (4) Support, Barriers, and Professional Development, and (5) Future Outlook of the Profession. There was a perceived status gap between the operational value of RTs and the undervaluation of their professional identity. There was a common theme that an advanced degree could positively impact patient outcomes, but leadership needs more tangible evidence. An advanced degree may provide distinguishable legitimacy that complements RTs’ experience and credentials. Participants feel that formal education and localized professional development serve different but equally vital purposes. There was a reported desire for higher-educated RTs, but there is a quantity crisis that must also be navigated. Conclusions: This study explored leadership perceptions regarding advanced respiratory care degrees, finding that while leaders value higher education alongside credentials and experience as vital for advancing the profession, key barriers to acquisition remain.
- 30 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessAn exploration of perceptions of U.S.-based respiratory care department leaders regarding advanced degrees among their clinical staff
Background: Though the skill set and scope of practice for respiratory therapists (RT) have expanded over the years, the minimum degree required for entry into practice has remained at the associate-degree level. Respiratory department leadership set the tone for hiring preferences and education expectations for their staff. The purpose of this study is to understand the perceptions of RT department managers/directors regarding RTs with advanced degrees (bachelor’s or higher). Methods: Twenty virtual semi-structured interviews with RT department leaders from across the United States were conducted between February and March 2026. Transcripts were coded by four investigators and analyzed for themes. Results: Of the 20 participants, 12 were department managers and 8 were directors. Nine were female and 11 were male. There was near-equal distribution across the four demographic regions. Nine participants reported having earned the AARC Apex designation for Acute Care facilities. Interview questions were categorized into five content areas: (1) Value and Perception of RT, (2) Impact of Advanced Degrees, (3) Leadership and Career Advancement, (4) Support, Barriers, and Professional Development, and (5) Future Outlook of the Profession. There was a perceived status gap between the operational value of RTs and the undervaluation of their professional identity. There was a common theme that an advanced degree could positively impact patient outcomes, but leadership needs more tangible evidence. An advanced degree may provide distinguishable legitimacy that complements RTs’ experience and credentials. Participants feel that formal education and localized professional development serve different but equally vital purposes. There was a reported desire for higher-educated RTs, but there is a quantity crisis that must also be navigated. Conclusions: This study explored leadership perceptions regarding advanced respiratory care degrees, finding that while leaders value higher education alongside credentials and experience as vital for advancing the profession, key barriers to acquisition remain.
- Open Access
- 27 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
A cross-national examination of weaning assessments: Comparing respiratory therapists’ perceptions in Saudi Arabia and the United States
Background: Weaning from mechanical ventilation is a fundamental objective in intensive care, as successful weaning reduces morbidity and mortality and reduces intensive care unit resource utilization. Multiple physiological and clinical assessments guide the weaning process; however, practice patterns and therapists’ perceptions may vary across healthcare systems. Understanding these differences can inform clinical training and standardization efforts across respiratory care practice. Methods: A cross-sectional online survey was administered to respiratory therapists in Saudi Arabia and the United States. The questionnaire included demographic items and Likert-scale questions assessing perceived frequency of use and prioritization of weaning assessments, as well as the influence of patient-specific clinical factors on ventilator weaning decisions. Descriptive statistics and Mann–Whitney U tests were calculated. Statistical significance was set at P < .05. Results: A total of 99 respiratory therapists completed the survey (Saudi Arabia: n = 63; United States: n = 36). Among patient-specific factors, age and neuromuscular blockade differed significantly between countries, with Saudi respiratory therapists reporting greater perceived influence than U.S. respiratory therapists ( P = .01 and P = .042, respectively). Of the 18 weaning assessments evaluated, only the Glasgow Coma Score (GCS) differed significantly between countries, with Saudi respiratory therapists reporting higher prioritization than U.S. respiratory therapists ( P < .001). The most frequently prioritized weaning assessments among Saudi respiratory therapists were spontaneous breathing trials (SBTs), GCS, breathing frequency, pH, and P a CO 2 . U.S. respiratory therapists most commonly prioritized SBTs, minute ventilation, pH, P a CO 2 , and following commands. Conclusions: Few differences were identified between countries, suggesting consistent clinical perceptions regarding ventilator weaning assessments and practices among respiratory therapists in both countries. These findings support a shared evidence-based foundation across both settings and may inform benchmarking efforts and educational strategies in respiratory therapy.
- 27 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessA cross-national examination of weaning assessments: Comparing respiratory therapists’ perceptions in Saudi Arabia and the United States
Background: Weaning from mechanical ventilation is a fundamental objective in intensive care, as successful weaning reduces morbidity and mortality and reduces intensive care unit resource utilization. Multiple physiological and clinical assessments guide the weaning process; however, practice patterns and therapists’ perceptions may vary across healthcare systems. Understanding these differences can inform clinical training and standardization efforts across respiratory care practice. Methods: A cross-sectional online survey was administered to respiratory therapists in Saudi Arabia and the United States. The questionnaire included demographic items and Likert-scale questions assessing perceived frequency of use and prioritization of weaning assessments, as well as the influence of patient-specific clinical factors on ventilator weaning decisions. Descriptive statistics and Mann–Whitney U tests were calculated. Statistical significance was set at P < .05. Results: A total of 99 respiratory therapists completed the survey (Saudi Arabia: n = 63; United States: n = 36). Among patient-specific factors, age and neuromuscular blockade differed significantly between countries, with Saudi respiratory therapists reporting greater perceived influence than U.S. respiratory therapists ( P = .01 and P = .042, respectively). Of the 18 weaning assessments evaluated, only the Glasgow Coma Score (GCS) differed significantly between countries, with Saudi respiratory therapists reporting higher prioritization than U.S. respiratory therapists ( P < .001). The most frequently prioritized weaning assessments among Saudi respiratory therapists were spontaneous breathing trials (SBTs), GCS, breathing frequency, pH, and P a CO 2 . U.S. respiratory therapists most commonly prioritized SBTs, minute ventilation, pH, P a CO 2 , and following commands. Conclusions: Few differences were identified between countries, suggesting consistent clinical perceptions regarding ventilator weaning assessments and practices among respiratory therapists in both countries. These findings support a shared evidence-based foundation across both settings and may inform benchmarking efforts and educational strategies in respiratory therapy.
- Open Access
- 23 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
The effect of cannula and oral aperture size on airway pressure generation during high-flow nasal cannula therapy
Background: High-flow nasal cannula (HFNC) therapy can deliver ideally conditioned (body temperature, pressure, and water vapor saturated) gas at high flows with variable oxygen concentrations. Two proposed benefits are the washout of CO 2 from the upper airways and the production of a coincident positive airway pressure. The effects of cannula geometry and various degrees of mouth opening on the positive airway pressure generated by HFNC were tested using a computerized mathematical model based upon a scan of a human airway. Methods: Computational fluid dynamics models of the human upper airway were used to collect pressure information throughout the airway. Mouth openings of 5, 10, 20, 30, and 100% were tested. Small-bore and large-bore cannula geometries were tested. All other airway components and therapy settings remained unchanged across tests. Results: The small-bore cannula geometry produced higher distending pressures than the large-bore cannula geometry. Smaller mouth openings generated higher pressures than larger mouth openings. Mean positive airway pressure during expiration (P aw,exp ) ranged from 1.20 cm H 2 O to 3.97 cm H 2 O over the scenarios tested. Mean positive airway pressure during inspiration (P aw,insp ) ranged from −0.002 cm H 2 O to 0.734 cm H 2 O over the scenarios tested. Positive airway pressure at end expiration (P aw,EE ) ranged from 0.512 cm H 2 O to 2.24 cm H 2 O over the scenarios tested. Maximum pressures were generated using a small-bore cannula at a mouth opening of 5%, while minimum pressures were generated using a large-bore cannula at a mouth opening of 100%. Conclusions: Mouth opening size and cannula prong size had a measurable effect on positive airway pressure resulting from HFNC. The smaller the mouth opening, the greater the resulting pressure. The small-bore cannula geometry produced higher pressures than the large-bore geometry at the same settings, indicating that a lower therapy flow using a small-bore cannula could provide an equivalent pressure to that of therapy using a large-bore geometry.
- 23 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessThe effect of cannula and oral aperture size on airway pressure generation during high-flow nasal cannula therapy
Background: High-flow nasal cannula (HFNC) therapy can deliver ideally conditioned (body temperature, pressure, and water vapor saturated) gas at high flows with variable oxygen concentrations. Two proposed benefits are the washout of CO 2 from the upper airways and the production of a coincident positive airway pressure. The effects of cannula geometry and various degrees of mouth opening on the positive airway pressure generated by HFNC were tested using a computerized mathematical model based upon a scan of a human airway. Methods: Computational fluid dynamics models of the human upper airway were used to collect pressure information throughout the airway. Mouth openings of 5, 10, 20, 30, and 100% were tested. Small-bore and large-bore cannula geometries were tested. All other airway components and therapy settings remained unchanged across tests. Results: The small-bore cannula geometry produced higher distending pressures than the large-bore cannula geometry. Smaller mouth openings generated higher pressures than larger mouth openings. Mean positive airway pressure during expiration (P aw,exp ) ranged from 1.20 cm H 2 O to 3.97 cm H 2 O over the scenarios tested. Mean positive airway pressure during inspiration (P aw,insp ) ranged from −0.002 cm H 2 O to 0.734 cm H 2 O over the scenarios tested. Positive airway pressure at end expiration (P aw,EE ) ranged from 0.512 cm H 2 O to 2.24 cm H 2 O over the scenarios tested. Maximum pressures were generated using a small-bore cannula at a mouth opening of 5%, while minimum pressures were generated using a large-bore cannula at a mouth opening of 100%. Conclusions: Mouth opening size and cannula prong size had a measurable effect on positive airway pressure resulting from HFNC. The smaller the mouth opening, the greater the resulting pressure. The small-bore cannula geometry produced higher pressures than the large-bore geometry at the same settings, indicating that a lower therapy flow using a small-bore cannula could provide an equivalent pressure to that of therapy using a large-bore geometry.
- Open Access
- 9 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Exploring faculty perspectives of the affective domain of learning in entry-to-practice respiratory therapy education
Background: The affective domain of learning is one of the three learning domains described in Bloom’s taxonomy and is considered an important component of entry-to-practice respiratory therapy education. Although accreditation standards require assessment of the cognitive, psychomotor, and affective learning domains in respiratory therapy education, the affective domain remains poorly defined and underexplored. The purpose of this study was to examine the affective domain of learning in entry-to-practice respiratory therapy education, with specific attention to how faculty define the domain and support its development. Methods: This study utilized an exploratory descriptive qualitative research design. 19 respiratory therapy faculty members participated in semi-structured interviews conducted using audiovisual conferencing technology. Interview transcripts were analyzed using reflexive thematic analysis, informed by a social constructivist perspective. Results: Analysis resulted in three themes: Inward Reflection, Outward Connection ; The Telling and Doing of Becoming ; and Different Paths, Same Destination . Findings illustrate how faculty conceptualize affective learning as a process involving self-reflection, relational engagement, and professional identity development. Conclusions: While faculty described a range of instructional strategies and approaches, these practices reflected common educational goals related to the development of professional values, attitudes, and behaviors. These findings contribute conceptual clarity to the affective domain within respiratory therapy education and support its more intentional integration within entry-to-practice curricula.
- 9 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessExploring faculty perspectives of the affective domain of learning in entry-to-practice respiratory therapy education
Background: The affective domain of learning is one of the three learning domains described in Bloom’s taxonomy and is considered an important component of entry-to-practice respiratory therapy education. Although accreditation standards require assessment of the cognitive, psychomotor, and affective learning domains in respiratory therapy education, the affective domain remains poorly defined and underexplored. The purpose of this study was to examine the affective domain of learning in entry-to-practice respiratory therapy education, with specific attention to how faculty define the domain and support its development. Methods: This study utilized an exploratory descriptive qualitative research design. 19 respiratory therapy faculty members participated in semi-structured interviews conducted using audiovisual conferencing technology. Interview transcripts were analyzed using reflexive thematic analysis, informed by a social constructivist perspective. Results: Analysis resulted in three themes: Inward Reflection, Outward Connection ; The Telling and Doing of Becoming ; and Different Paths, Same Destination . Findings illustrate how faculty conceptualize affective learning as a process involving self-reflection, relational engagement, and professional identity development. Conclusions: While faculty described a range of instructional strategies and approaches, these practices reflected common educational goals related to the development of professional values, attitudes, and behaviors. These findings contribute conceptual clarity to the affective domain within respiratory therapy education and support its more intentional integration within entry-to-practice curricula.
- Open Access
- 1 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Optimizing oxygen delivery in duckbill bag-valve-mask devices during spontaneous breathing
Introduction: Pre-oxygenation is often performed with bag-valve-mask (BVM) devices whose oxygen delivery performance during spontaneous breathing is incompletely characterized. Duckbill-valve BVMs without an expiratory valve are prone to air entrainment during inspiration. This study evaluated how patient valve configuration and ventilatory pattern influence oxygen delivery during simulated spontaneous breathing with two duckbill devices. Methods: In a mechanical lung simulator, we tested two adult BVMs: a duckbill device without an expiratory valve (Med-Rescuer) and one with a disc-type expiratory valve (Laerdal The BAG II). Devices were supplied with oxygen flows of 8, 15, or 30 L/min. Spontaneous breathing patterns were programmed across a broad range of volumes (250–1000 mL) and rates (15 and 25 breaths per minute). Additional runs for Med-Rescuer included a PEEP valve (5 and 10 cm H 2 O) to reduce air entrainment. Results: For Med-Rescuer, delivered oxygen fraction ( FDO 2 ) decreased significantly once volume exceeded 250 mL ( P < .001), plateauing around 0.66–0.72 at higher volumes and oxygen flow of 15 L/min, independent of rate. Laerdal The BAG II maintained higher FDO 2 (0.74–0.92) across most volumes. Increasing oxygen flow from 8 to 30 L/min improved FDO 2 for both devices ( P < .001), with Laerdal consistently delivering higher FDO 2 than Med-Rescuer at all flows ( P < .001). Crucially, adding a PEEP valve to Med-Rescuer increased the FDO 2 from 0.71 to 0.98 ( P < .001), with no additional benefit seen at 10 versus 5 cm H 2 O PEEP ( P > .99). Conclusions: The duckbill BVM incorporating an expiratory valve delivered higher and more stable FDO 2 across the tested range of simulated volumes and rates than the duckbill device without an expiratory valve. The FDO 2 delivered by the duckbill system without an expiratory valve could be substantially improved by higher oxygen flow rates and, most effectively, by adding a PEEP valve.
- 1 October 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessOptimizing oxygen delivery in duckbill bag-valve-mask devices during spontaneous breathing
Introduction: Pre-oxygenation is often performed with bag-valve-mask (BVM) devices whose oxygen delivery performance during spontaneous breathing is incompletely characterized. Duckbill-valve BVMs without an expiratory valve are prone to air entrainment during inspiration. This study evaluated how patient valve configuration and ventilatory pattern influence oxygen delivery during simulated spontaneous breathing with two duckbill devices. Methods: In a mechanical lung simulator, we tested two adult BVMs: a duckbill device without an expiratory valve (Med-Rescuer) and one with a disc-type expiratory valve (Laerdal The BAG II). Devices were supplied with oxygen flows of 8, 15, or 30 L/min. Spontaneous breathing patterns were programmed across a broad range of volumes (250–1000 mL) and rates (15 and 25 breaths per minute). Additional runs for Med-Rescuer included a PEEP valve (5 and 10 cm H 2 O) to reduce air entrainment. Results: For Med-Rescuer, delivered oxygen fraction ( FDO 2 ) decreased significantly once volume exceeded 250 mL ( P < .001), plateauing around 0.66–0.72 at higher volumes and oxygen flow of 15 L/min, independent of rate. Laerdal The BAG II maintained higher FDO 2 (0.74–0.92) across most volumes. Increasing oxygen flow from 8 to 30 L/min improved FDO 2 for both devices ( P < .001), with Laerdal consistently delivering higher FDO 2 than Med-Rescuer at all flows ( P < .001). Crucially, adding a PEEP valve to Med-Rescuer increased the FDO 2 from 0.71 to 0.98 ( P < .001), with no additional benefit seen at 10 versus 5 cm H 2 O PEEP ( P > .99). Conclusions: The duckbill BVM incorporating an expiratory valve delivered higher and more stable FDO 2 across the tested range of simulated volumes and rates than the duckbill device without an expiratory valve. The FDO 2 delivered by the duckbill system without an expiratory valve could be substantially improved by higher oxygen flow rates and, most effectively, by adding a PEEP valve.
- Open Access
- 20 August 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
The digital respiratory therapist: A staged implementation framework
- 20 August 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessThe digital respiratory therapist: A staged implementation framework
- Open Access
- 11 August 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Proof-of-principle evaluation of a real-time 3D video respiratory monitoring device
Background: Continuous monitoring of breathing frequency ( f ), tidal volume ( V T ), and flow parameters is essential in intensive care units (ICUs) for detecting early respiratory deterioration. In spontaneously breathing ICU patients, these parameters are difficult to measure continuously because spirometry requires cooperation and interrupts care. Non-contact depth-based sensing may offer a practical and real-time alternative for bedside respiratory monitoring. Methods: This prospective study evaluated the accuracy of a Kinect Azure–based RGB-D camera system (3DRespiView) designed for automated and non-invasive respiratory monitoring in an ICU-oriented configuration. Healthy adult volunteers underwent simultaneous recordings with a spirometer (reference) and the 3DRespiView system. Each participant completed three 30-second sessions of spontaneous breathing in the supine position. The system automatically detected the thorax, quantified 3D surface displacement, and extracted respiratory parameters including V T , f , inspiratory time ( T i ), expiratory time ( T e ), and peak inspiratory and expiratory flows (PIF/PEF). Agreement was assessed using Bland–Altman analysis, correlation coefficients, mean absolute error (MAE), and root mean square error (RMSE). Results: Eight participants completed 24 paired recordings. 3DRespiView demonstrated high accuracy across all parameters. For V T , the Bland–Altman bias was 24.1 mL with limits of agreement −17.7 to +66.0 mL; MAE was 26 mL (3.5%) and RMSE 33 mL (4.9%), with a strong correlation (R 2 = 0.99). Breathing frequency ( f ) showed perfect agreement with spirometry (MAE = 0%, R 2 = 1), and T i and T e showed MAEs of 0.10 s (5.2%) and 0.09 s (4.1%), respectively. PIF and PEF showed MAEs of 21 mL/s (3.6%) and 28 mL/s (5.6%), with correlations ranging from R 2 = 0.93 to 0.98. Volume–time waveform comparison showed close temporal alignment between modalities. Conclusions: 3DRespiView demonstrates the potential for accurate, automated, and real-time estimation of respiratory parameters using a non-contact 3D camera. These findings support the technical validity of the approach and highlight its future potential for continuous bedside respiratory monitoring in the ICU.
- 11 August 2026
- Published by SAGE Publications in Respiratory Care Reports
- Vol. 2
Open AccessProof-of-principle evaluation of a real-time 3D video respiratory monitoring device
Background: Continuous monitoring of breathing frequency ( f ), tidal volume ( V T ), and flow parameters is essential in intensive care units (ICUs) for detecting early respiratory deterioration. In spontaneously breathing ICU patients, these parameters are difficult to measure continuously because spirometry requires cooperation and interrupts care. Non-contact depth-based sensing may offer a practical and real-time alternative for bedside respiratory monitoring. Methods: This prospective study evaluated the accuracy of a Kinect Azure–based RGB-D camera system (3DRespiView) designed for automated and non-invasive respiratory monitoring in an ICU-oriented configuration. Healthy adult volunteers underwent simultaneous recordings with a spirometer (reference) and the 3DRespiView system. Each participant completed three 30-second sessions of spontaneous breathing in the supine position. The system automatically detected the thorax, quantified 3D surface displacement, and extracted respiratory parameters including V T , f , inspiratory time ( T i ), expiratory time ( T e ), and peak inspiratory and expiratory flows (PIF/PEF). Agreement was assessed using Bland–Altman analysis, correlation coefficients, mean absolute error (MAE), and root mean square error (RMSE). Results: Eight participants completed 24 paired recordings. 3DRespiView demonstrated high accuracy across all parameters. For V T , the Bland–Altman bias was 24.1 mL with limits of agreement −17.7 to +66.0 mL; MAE was 26 mL (3.5%) and RMSE 33 mL (4.9%), with a strong correlation (R 2 = 0.99). Breathing frequency ( f ) showed perfect agreement with spirometry (MAE = 0%, R 2 = 1), and T i and T e showed MAEs of 0.10 s (5.2%) and 0.09 s (4.1%), respectively. PIF and PEF showed MAEs of 21 mL/s (3.6%) and 28 mL/s (5.6%), with correlations ranging from R 2 = 0.93 to 0.98. Volume–time waveform comparison showed close temporal alignment between modalities. Conclusions: 3DRespiView demonstrates the potential for accurate, automated, and real-time estimation of respiratory parameters using a non-contact 3D camera. These findings support the technical validity of the approach and highlight its future potential for continuous bedside respiratory monitoring in the ICU.