Database Coverage
  • Scilit
Journal Articles
All-time journal articles
5
2025 journal articles
0
Subject
  • Dermatology
  • Hepatitis
  • Sports Science
  • Osteopathies
  • AI & Machine Learning
  • Computer Vision & Graphics

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Dermatology
2
Sports Science
1
Diagnostic & Therapeutic Ultrasound
1
AI & Machine Learning
1
Anesthetic & Pain Medicine
1
Computer Vision & Graphics
1
Hepatitis
1
Mechanics
1
Osteopathies
1
Musculoskeletal Disorders
1

Top Countries

Publications in 2016-2026.

CountryPublications
Turkey
3

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
0
Total Publications
0
Average Citations
0.00
Cited Publications
0
Cited Publications %
0%
Self Citations
0
Self Citations %
0%

Metrics
h5_index
0
Monthly Citation Metric (MCM)
0

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
0
Max
0

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Optimization and Mathematical Formulation of a DBNE–AlexNet–BiLSTM Hybrid Network for Dermatological Image Classification

    by Nitalaksheswara Rao Kolukula, Jayasree Pinajala, James Stephen Meka

    One of the deadliest forms of cancer is skin cancer, especially melanoma, which calls for accurate and efficient detection methods. Biopsies and other traditional diagnostic techniques are disruptive, time-consuming, and often painful. Automated skin cancer classification has been made possible by novel advances in deep learning method. However, processing resolution images, and obtaining high accuracy, and requiring enormous datasets are the challenges for current techniques. In a bid to enhance skin cancer classification, this research proposes a hybrid model that combines Deep Batch-normalized eLU AlexNet (DbneAlexNet) and Bi-directional Long Short-Term Memory (Bi-LSTM). The approach includes pre-processing with guassian filters, Region of Interest (RoI) extraction, and skin lesion segmentation using Multi Scale Receptive Field Network (MSRFNet). Geometric and color space transformations are two different image augmentation that enhance dataset diversity. To provide high quality feature representation, feature extraction is performed by applying statistical parameters and Local Vector Position (LVP). The proposed hybrid model exceeds current techniques in terms of classification accuracy. Its remarkable 99.6% classification accuracy demonstrates how effective it is at automatically detecting skin cancer. This research addresses the drawback of existing techniques by providing a reliable, non-invasive, and efficient early detection technique.

  • Open Access

    Comparative Evaluation of Isotropic, Transversely Isotropic, and Orthotropic Material Properties in Human Femur Finite Element Analysis under Complex Loading Conditions

    by Talip Çelik, Arif Özkan

    The precision of Finite Element Analysis in skeletal biomechanics is heavily dependent on the accurate representation of bone’s material symmetry. This study aims to quantify the influence of isotropic, transversely isotropic, and orthotropic material models on the mechanical response of a detailed human femur model including cortical bone, trabecular networks, and marrow. A high-resolution 3D femur geometry was segmented and subjected to nine simulation scenarios. These scenarios combined three material symmetry assumptions-Isotropic, Transversely Isotropic, and Orthotropic-with three physiological loading modes: axial (1000 N), torsional (10,000 Nmm), and combined axial-torsional loading. Equivalent von Mises stress, total deformation, and equivalent strain (με) were evaluated using ANSYS Workbench software. While results were relatively consistent under axial loading (stress variations within 4-6%), significant discrepancies emerged under torsional and combined modes. For torsional loading, the isotropic model underestimated total deformation by 32% and equivalent strain by 43% compared to the orthotropic reference. Conversely, the transversely isotropic model predicted the highest structural compliance, overestimating deformation by 33% relative to the orthotropic case. In all combined loading states, the orthotropic model provided the most balanced representation of directional stiffness. The findings underscore that isotropic simplifications are particularly unreliable for predicting strain distributions and structural stability during rotational movements. Orthotropic material properties should be implemented to ensure clinical relevance in orthopedic simulations and fracture risk assessments.

  • Open Access

    Design, Thermal Modeling and Metaheuristic Based PID Control of a Hand Heater System to Improve Pulse Oximetry Performance Under Low Perfusion Conditions

    by Mehmet Ekici, Kutay Aydın

    Pulse oximeters are critical clinical devices widely used for the non-invasive monitoring of peripheral oxygen saturation (SpO₂). However, low peripheral perfusion and reduced tissue temperature significantly reduce measurement accuracy, particularly in patients who remain immobile for extended periods, and in some cases prevent measurements from being taken at all. In clinical practice, passive heating methods are typically used to address this issue; however, these approaches are uncontrolled and limited in terms of reproducibility. In this study, a controlled hand-heating system was designed and developed to improve pulse oximeter measurements under low-perfusion conditions. The system provides homogeneous heating of the hand’s upper and lower surfaces using low-power resistive heaters. A three-dimensional heater geometry was designed, the resistor placement was optimized, and a prototype was manufactured. Subsequently, a First-Order Plus Dead Time (FOPDT) transfer function was derived using experimental temperature-time data (33.9 °C initial, 46.9 °C steady-state temperature) obtained from the prototype’s open-loop step response. Particle Swarm Optimization (PSO) and Artificial Bee Colony (ABC) algorithms were compared and competed against each other in the optimization of a filtered PID controller architecture capable of maintaining hand temperature exactly at 36.0 °C body temperature with system identification and zero overshoot. While both algorithms showed a similar convergence error ("RMSE"≈0.81 °C), the PSO algorithm demonstrated absolute stability in parameter estimation with a standard deviation of 0.0000. When subjected to a sudden -1.5 °C load disturbance applied at t=400. seconds to simulate clinical disturbance scenarios, the optimized controllers were observed to rapidly recover the temperature with an instantaneous power increase and stabilize it back to 36.0 °C within seconds. The controlled thermal intervention system developed offers an approach for ensuring the stable thermal perfusion conditions required for pulse oximetry measurements, and the design and simulation results demonstrate that the system is configured to operate within its safety limits.

  • Open Access

    Machine Learning Prediction of Hepatic Steatosis from Routine Metabolic and Lipid Markers: A Cross-Sectional Analysis of NHANES 2017-2018

    by Funda Kutlu Onay

    Hepatic steatosis, or fatty liver, is the defining lesion of metabolic dysfunction-associated steatotic liver disease (MASLD), and its prevalence continues to rise. Vibration-controlled transient elastography (FibroScan) measures liver fat through the controlled attenuation parameter (CAP). Because access to elastography is limited in many settings, the question of whether routinely measured blood markers can identify steatosis is of practical interest. Records of 7,724 participants from the National Health and Nutrition Examination Survey (NHANES) 2017-2018 with a valid CAP measurement were analysed. Steatosis was defined as a CAP value of 274 dB/m or higher. Six routinely available markers were used as predictors (insulin, systolic and diastolic blood pressure, total cholesterol, triglycerides, and LDL cholesterol). Liver stiffness and CAP, both produced by elastography, were excluded so that prediction relied only on data obtainable without that device. Logistic regression, random forest, and gradient boosting (XGBoost, with and without SMOTE) were compared using stratified five-fold cross-validation and a held-out internal test set (25 percent). Imputation and standardisation were carried out inside the cross-validation pipeline to prevent leakage, and test-set performance is reported with 95 percent bootstrap confidence intervals. Steatosis was present in 38.6 percent of the sample. The random forest gave the strongest performance, with a test ROC-AUC of 0.876 (95 percent CI 0.861 to 0.891), a PR-AUC of 0.820, and a Brier score of 0.140; its cross-validated ROC-AUC was 0.846. XGBoost followed (test AUC 0.835), and logistic regression served as a linear baseline (0.786). Insulin and triglycerides carried the most predictive information. Synthetic oversampling did not improve performance, and the cross-validated discrimination of the random forest stayed close to 0.845 across alternative steatosis thresholds. Routine blood and blood-pressure markers, obtainable without elastography, identify CAP-defined hepatic steatosis with good discrimination and adequate calibration, which supports their possible use in non-invasive screening. The findings are cross-sectional, and external and prospective validation is still required.

  • Open Access

    A Comparative Benchmark of Transformer-Based Architectures for Dermoscopic Skin Lesion Classification on the HAM10000 Dataset

    by Salih Berkan Aydemir

    Skin cancer is among the most prevalent malignancies worldwide, and early accurate classification of dermoscopic lesions is critical for improving patient outcomes. While convolutional neural networks have long dominated automated dermatology, Transformer-based architectures have emerged as competitive alternatives owing to their capacity to model long-range spatial dependencies. However, systematic comparisons among Transformer families under identical protocols remain scarce. We benchmark four representative architectures Vision Transformer (ViT-B/16), Swin Transformer (Swin-T), a hybrid EfficientNet-B4 with Transformer encoder, and self-supervised DINOv2-Small for seven-class dermoscopic lesion classification on HAM10000 using five-fold stratified cross-validation. The Swin Transformer achieved the highest performance (accuracy 0.8520 ± 0.0151, macro-F1 0.8582 ± 0.0084, AUC-ROC 0.9861 ± 0.0012), outperforming ViT-B/16 by 9.5 percentage points in F1. DINOv2, despite a competitive AUC-ROC (0.9243 ± 0.0039), underperformed in F1 (0.5656 ± 0.0178) under this fixed fine-tuning budget, suggesting that self-supervised features require extended adaptation for imbalanced dermoscopic data. Our results provide actionable guidance for architecture selection under realistic constraints.