Cook Medical (United States)
Types
Company, FunderLocations
Bloomington, United StatesRelationships
Latest Publications
- Open Access
- 1 September 2026
- Published by BMJ in BMJ Connections Surgery
- Vol. 8 (1) , e000028
Evaluation of devices used for endovascular repair of ruptured abdominal aortic aneurysms in the international consortium of vascular registries: an international, retrospective, multicentre, single-arm, open-label performance goal study
Introduction: The purpose of this study was to pilot a new concept for device appraisal—leveraging international real-world data (RWD) from the International Consortium of Vascular Registries (ICVRs) to assess aggregate endovascular aortic repair (EVAR) performance against a conservative performance goal (PG) derived from open surgical repair (OSR), with the intention of helping refine device labelling in collaboration with industry and the US Food and Drug Administration. Research Design and Methods: International retrospective, multicentre, single-arm cohort, open-label clinical PG-based study within the ICVRs. Because OSR patients may not have been anatomically EVAR-eligible, the OSR cohort used for PG derivation was restricted to smaller diameters (<6.5 cm men; <5.5 cm women) to include patients eligible for EVAR. Analyses performed at Weill Cornell Medicine (MDEpiNet Center). Results: OSR PG cohort: 932 patients (72±9 years average; 83.8% men) with 30% in-hospital mortality. EVAR cohort: 219 patients (75±10 years average, 83.1% men) with larger aneurysms (EVAR 7.3±2.0 cm vs OSR 5.3±1.3 cm; p<0.001). In-hospital mortality after EVAR was 18% (upper 95% CI 13% to 23%), exceeding the PG (p<0.001). EVAR showed lower dialysis (10.6% vs 15.7%; p=0.02), bowel ischaemia (1.8% vs 7.5%; p<0.001) and reoperation for bleeding (2.7% vs 7.1%; p=0.004). Conclusions: This proof-of-concept study shows harmonised international RWD can evaluate device performance in ruptured abdominal aortic aneurysm. Despite a comparator biased to favour OSR, EVAR met/exceeded the PG and reduced complications, supporting regulatory discussions to align instructions for use with guideline-endorsed EVAR-first strategies
- 1 September 2026
- Published by BMJ in BMJ Connections Surgery
- Vol. 8 (1) , e000028
Open AccessEvaluation of devices used for endovascular repair of ruptured abdominal aortic aneurysms in the international consortium of vascular registries: an international, retrospective, multicentre, single-arm, open-label performance goal study
Introduction: The purpose of this study was to pilot a new concept for device appraisal—leveraging international real-world data (RWD) from the International Consortium of Vascular Registries (ICVRs) to assess aggregate endovascular aortic repair (EVAR) performance against a conservative performance goal (PG) derived from open surgical repair (OSR), with the intention of helping refine device labelling in collaboration with industry and the US Food and Drug Administration. Research Design and Methods: International retrospective, multicentre, single-arm cohort, open-label clinical PG-based study within the ICVRs. Because OSR patients may not have been anatomically EVAR-eligible, the OSR cohort used for PG derivation was restricted to smaller diameters (<6.5 cm men; <5.5 cm women) to include patients eligible for EVAR. Analyses performed at Weill Cornell Medicine (MDEpiNet Center). Results: OSR PG cohort: 932 patients (72±9 years average; 83.8% men) with 30% in-hospital mortality. EVAR cohort: 219 patients (75±10 years average, 83.1% men) with larger aneurysms (EVAR 7.3±2.0 cm vs OSR 5.3±1.3 cm; p<0.001). In-hospital mortality after EVAR was 18% (upper 95% CI 13% to 23%), exceeding the PG (p<0.001). EVAR showed lower dialysis (10.6% vs 15.7%; p=0.02), bowel ischaemia (1.8% vs 7.5%; p<0.001) and reoperation for bleeding (2.7% vs 7.1%; p=0.004). Conclusions: This proof-of-concept study shows harmonised international RWD can evaluate device performance in ruptured abdominal aortic aneurysm. Despite a comparator biased to favour OSR, EVAR met/exceeded the PG and reduced complications, supporting regulatory discussions to align instructions for use with guideline-endorsed EVAR-first strategies
- Open Access
- 18 May 2026
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 11 (6) , 101562
Feasibility of Magnetic Resonance Imaging–Guided Pulmonary Artery Stenting in a Commercial Wide-Bore 0.55-T Scanner
- 18 May 2026
- Published by Elsevier in JACC: Basic To Translational Science
- Vol. 11 (6) , 101562
Open AccessFeasibility of Magnetic Resonance Imaging–Guided Pulmonary Artery Stenting in a Commercial Wide-Bore 0.55-T Scanner
- Open Access
- 29 May 2025
- Published by Elsevier in JHEP Reports
- Vol. 7 (8) , 101466
Endoscopic ultrasound-guided portosystemic pressure gradient measurement vs. transjugular balloon occlusion measurement in patients with cirrhosis (ENCOUNTER): A bicentric EU study
- 29 May 2025
- Published by Elsevier in JHEP Reports
- Vol. 7 (8) , 101466
Open AccessEndoscopic ultrasound-guided portosystemic pressure gradient measurement vs. transjugular balloon occlusion measurement in patients with cirrhosis (ENCOUNTER): A bicentric EU study
- Open Access
- 1 May 2025
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 20 (3) , 244
FET Repair With the Cook FET-FEN Device
- 1 May 2025
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 20 (3) , 244
Open AccessFET Repair With the Cook FET-FEN Device
- Open Access
- 9 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 401
Pressure–Flow Relation of Porcine Thoracic Duct Segment
The lymphatic system collects excess fluid and molecules from the interstitial space back into the venous system mainly via the thoracic duct (TD). Despite the importance of the lymphatic flow in health and disease, a validated pressure–flow relation of lymphatic fluid through the TD is lacking in a translational large animal model. The objective of this work was to establish a pressure–flow relationship for a TD segment with one valve in a swine model. Our methodology consisted of using a specialized bench experimental setup to measure the passive forward flow of 0.9% saline through single-valve TD segments (n = 5) under various pressure gradients. Using Poiseuille’s law, we computed the resistance to flow in the TD segment. Subsequently, we used a sigmoidal function to model the relation between valve resistance and pressure gradient across the valve. We estimated the model’s parameters using the Poiseuille-based resistance values and associated experimental pressure date then validated the model by comparing model predictions of flow to experimental measurements. We found that the model performs accurately (). The resistance model validated here for a single valve TD segment provides a fundamental element for computational simulations of lymphatic flow in the entire TD. Moreover, this work provides a baseline for future characterization of TD behavior under pathological conditions, such as congestive heart failure or hepatitis caused ascites.- 9 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 401
Open AccessPressure–Flow Relation of Porcine Thoracic Duct Segment
The lymphatic system collects excess fluid and molecules from the interstitial space back into the venous system mainly via the thoracic duct (TD). Despite the importance of the lymphatic flow in health and disease, a validated pressure–flow relation of lymphatic fluid through the TD is lacking in a translational large animal model. The objective of this work was to establish a pressure–flow relationship for a TD segment with one valve in a swine model. Our methodology consisted of using a specialized bench experimental setup to measure the passive forward flow of 0.9% saline through single-valve TD segments (n = 5) under various pressure gradients. Using Poiseuille’s law, we computed the resistance to flow in the TD segment. Subsequently, we used a sigmoidal function to model the relation between valve resistance and pressure gradient across the valve. We estimated the model’s parameters using the Poiseuille-based resistance values and associated experimental pressure date then validated the model by comparing model predictions of flow to experimental measurements. We found that the model performs accurately (). The resistance model validated here for a single valve TD segment provides a fundamental element for computational simulations of lymphatic flow in the entire TD. Moreover, this work provides a baseline for future characterization of TD behavior under pathological conditions, such as congestive heart failure or hepatitis caused ascites. - 27 March 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 02) , eP1021
Endoscopic Ultrasound-Guided Portosystemic Pressure Gradient Measurement vs. Transjugular Balloon Occlusion Measurement (ENCOUNTER): A Multicenter EU Study
Aims Patients with cirrhosis and clinically significant portal hypertension are at elevated risk for hepatic decompensation and liver-related mortality. The hepatic venous pressure gradient (HVPG) is the accepted method for quantifying portal hypertension, providing valuable risk assessment and treatment guidance for individual patients. However, HVPG has limitations due to its indirect measurement approach and limited availability. Endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) offers an alternative using EUS-guided venipuncture to directly measure hepatic and portal venous pressures. The ENCOUNTER study is the first to compare EUS-PPG to HVPG in the same patient, simultaneously. Methods This prospective, international, bicentric study included patients referred for HVPG measurement or transjugular intrahepatic portosystemic shunt (TIPS) placement at the University Hospital of Leuven (Belgium) and Hospital Clinic Barcelona (Spain). Patients underwent standard-of-care HVPG, followed by simultaneous HVPG and EUS-PPG measurements under propofol general anesthesia. Adverse events were monitored for up to 30 days post-procedure. Results From a total of 35 patients, 14 had to be excluded because of intrahepatic venovenous shunts, hemodynamic instability and/or inadequate HVPG tracings. The final analysis included 21 patients with cirrhosis undergoing simultaneous HVPG and EUS-PPG of whom 15 received TIPS. All patients had underlying cirrhosis, which was predominantly alcohol-related (57.1%). Mean MELD score was 10.8±4.2 and most patients had Child-Pugh B cirrhosis. Mean HVPG and EUS-PPG under general anesthesia were comparable (11.9±5.2 vs. 10.9±5.6 mmHg, p=0.2332) and correlated with one another (r=0.74, p=0.0001). The individual components of the gradients (portal vein and hepatic vein) equally showed a good correlation (portal vein: r=0.85, p<0.0001; hepatic vein: r=0.72, p=0.0003). In patients receiving TIPS, direct transjugular portal pressure measurements demonstrated an excellent correlation with EUS-guided portal pressures (r=0.91, p<0.0001). Technical success was achieved in all cases, with no adverse events associated with the EUS-PPG procedure. Conclusions EUS-PPG is a reliable and safe alternative tool to HVPG for the direct measurement of portal pressure, and yields comparable results to HVPG when measured simultaneously in the same patients and under the same conditions. This technique could be particularly valuable in situations where non-invasive tests are unable to confirm or rule out portal hypertension, in conditions where HVPG underestimates portal hypertension, or when used alongside other endoscopic or endosonographic procedures. Future research should explore the impact of anesthesia on EUS-PPG, its role in monitoring therapeutic responses to beta-blocker therapy, as well as its cost-effectiveness. Article published online: 27 March 2025 © 2025. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 27 March 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 02) , eP1021
Endoscopic Ultrasound-Guided Portosystemic Pressure Gradient Measurement vs. Transjugular Balloon Occlusion Measurement (ENCOUNTER): A Multicenter EU Study
Aims Patients with cirrhosis and clinically significant portal hypertension are at elevated risk for hepatic decompensation and liver-related mortality. The hepatic venous pressure gradient (HVPG) is the accepted method for quantifying portal hypertension, providing valuable risk assessment and treatment guidance for individual patients. However, HVPG has limitations due to its indirect measurement approach and limited availability. Endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) offers an alternative using EUS-guided venipuncture to directly measure hepatic and portal venous pressures. The ENCOUNTER study is the first to compare EUS-PPG to HVPG in the same patient, simultaneously. Methods This prospective, international, bicentric study included patients referred for HVPG measurement or transjugular intrahepatic portosystemic shunt (TIPS) placement at the University Hospital of Leuven (Belgium) and Hospital Clinic Barcelona (Spain). Patients underwent standard-of-care HVPG, followed by simultaneous HVPG and EUS-PPG measurements under propofol general anesthesia. Adverse events were monitored for up to 30 days post-procedure. Results From a total of 35 patients, 14 had to be excluded because of intrahepatic venovenous shunts, hemodynamic instability and/or inadequate HVPG tracings. The final analysis included 21 patients with cirrhosis undergoing simultaneous HVPG and EUS-PPG of whom 15 received TIPS. All patients had underlying cirrhosis, which was predominantly alcohol-related (57.1%). Mean MELD score was 10.8±4.2 and most patients had Child-Pugh B cirrhosis. Mean HVPG and EUS-PPG under general anesthesia were comparable (11.9±5.2 vs. 10.9±5.6 mmHg, p=0.2332) and correlated with one another (r=0.74, p=0.0001). The individual components of the gradients (portal vein and hepatic vein) equally showed a good correlation (portal vein: r=0.85, p<0.0001; hepatic vein: r=0.72, p=0.0003). In patients receiving TIPS, direct transjugular portal pressure measurements demonstrated an excellent correlation with EUS-guided portal pressures (r=0.91, p<0.0001). Technical success was achieved in all cases, with no adverse events associated with the EUS-PPG procedure. Conclusions EUS-PPG is a reliable and safe alternative tool to HVPG for the direct measurement of portal pressure, and yields comparable results to HVPG when measured simultaneously in the same patients and under the same conditions. This technique could be particularly valuable in situations where non-invasive tests are unable to confirm or rule out portal hypertension, in conditions where HVPG underestimates portal hypertension, or when used alongside other endoscopic or endosonographic procedures. Future research should explore the impact of anesthesia on EUS-PPG, its role in monitoring therapeutic responses to beta-blocker therapy, as well as its cost-effectiveness. Article published online: 27 March 2025 © 2025. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 16 August 2024
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics Nexus
- Vol. 3 (05) , 056011-10
Multimodal fiber antenna for proximity and stress sensing
Fiber sensors are commonly used to detect environmental, physiological, optical, chemical, and biological factors. Thermally drawn fibers offer numerous advantages over other commercial products, including enhanced sensitivity, accuracy, improved functionality, and ease of manufacturing. Multimaterial, multifunctional fibers encapsulate essential internal structures within a microscale fiber, unlike macroscale sensors requiring separate electronic components. The compact size of fiber sensors enables seamless integration into existing systems, providing the desired functionality. We present a multimodal fiber antenna monitoring, in real time, both the local deformation of the fiber and environmental changes caused by foreign objects in proximity to the fiber. Time domain reflectometry propagates an electromagnetic wave through the fiber, allowing precise determination of spatial changes along the fiber with exceptional resolution and sensitivity. Local changes in impedance reflect fiber deformation, whereas proximity is detected through alterations in the evanescent field surrounding the fiber. The fiber antenna operates as a waveguide to detect local deformation through the antisymmetric mode and environmental changes through the symmetric mode. This multifunctionality broadens its application areas from biomedical engineering to cyber–physical interfacing. In antisymmetric mode, the device can sense local changes in pressure, and, potentially, temperature, pH, and other physiological conditions. In symmetric mode, it can be used in touch screens, environmental detection for security, cyber–physical interfacing, and human–robot interactions.
- 16 August 2024
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics Nexus
- Vol. 3 (05) , 056011-10
Open AccessMultimodal fiber antenna for proximity and stress sensing
Fiber sensors are commonly used to detect environmental, physiological, optical, chemical, and biological factors. Thermally drawn fibers offer numerous advantages over other commercial products, including enhanced sensitivity, accuracy, improved functionality, and ease of manufacturing. Multimaterial, multifunctional fibers encapsulate essential internal structures within a microscale fiber, unlike macroscale sensors requiring separate electronic components. The compact size of fiber sensors enables seamless integration into existing systems, providing the desired functionality. We present a multimodal fiber antenna monitoring, in real time, both the local deformation of the fiber and environmental changes caused by foreign objects in proximity to the fiber. Time domain reflectometry propagates an electromagnetic wave through the fiber, allowing precise determination of spatial changes along the fiber with exceptional resolution and sensitivity. Local changes in impedance reflect fiber deformation, whereas proximity is detected through alterations in the evanescent field surrounding the fiber. The fiber antenna operates as a waveguide to detect local deformation through the antisymmetric mode and environmental changes through the symmetric mode. This multifunctionality broadens its application areas from biomedical engineering to cyber–physical interfacing. In antisymmetric mode, the device can sense local changes in pressure, and, potentially, temperature, pH, and other physiological conditions. In symmetric mode, it can be used in touch screens, environmental detection for security, cyber–physical interfacing, and human–robot interactions.
- 22 July 2024
- Published by ASTM International in Materials Performance and Characterization
- Vol. 13 (2) , 122-135
Novel Fatigue-to-Fracture Technology for Super-Elastic Alloy in Cardiac Pulsatile Loading Mode
With regulatory scrutiny of medical devices on the rise, increased attention is being placed on the long-term safety and performance of permanent implants. State-of-the-art standards like ASTM F2477, Standard Test Methods forIn VitroPulsatile Durability Testing of Vascular Stents and Endovascular Prostheses, and ISO 25539-2, Cardiovascular Implants—Endovascular Devices—Part 2: Vascular Stents, for example, provide historical frameworks for empirically demonstrating adequate durability of vascular stents. Subsequent guidances have been published, which are gaining traction as complementary tools supporting the collective framework of long-term permanent implant understanding. ASTM F3211, Standard Guide for Fatigue-to-Fracture (FtF) Methodology for Cardiovascular Medical Devices, for example, outlines elegant methodologies for fatigue-to-fracture of cardiovascular medical devices. Some challenges that ensue, however, are apparent in exceptionally durable super-elastic alloys, like nitinol, where equipment limitations become rate limiting. Furthermore, once hyperphysiological loading levels are achieved, the subsequent challenge of fracture detection arises. Partnering with Dynatek Labs, Inc., Cook Medical presents a novel pulsatile fatigue testing platform capable of both applying hyperphysiological load levels, which induce fracture, as well as detecting fractures when they occur. Coupled with sophisticated statistical analysis projections, these pulsatile fatigue-to-fracture data align with cutting-edge standards like ASTM F3211 and provide confirmatory evidence of long-term permanent implant durability predictions associated with state-of-the-art standards of ASTM F2477 and ISO 25539-2.
- 22 July 2024
- Published by ASTM International in Materials Performance and Characterization
- Vol. 13 (2) , 122-135
Novel Fatigue-to-Fracture Technology for Super-Elastic Alloy in Cardiac Pulsatile Loading Mode
With regulatory scrutiny of medical devices on the rise, increased attention is being placed on the long-term safety and performance of permanent implants. State-of-the-art standards like ASTM F2477, Standard Test Methods forIn VitroPulsatile Durability Testing of Vascular Stents and Endovascular Prostheses, and ISO 25539-2, Cardiovascular Implants—Endovascular Devices—Part 2: Vascular Stents, for example, provide historical frameworks for empirically demonstrating adequate durability of vascular stents. Subsequent guidances have been published, which are gaining traction as complementary tools supporting the collective framework of long-term permanent implant understanding. ASTM F3211, Standard Guide for Fatigue-to-Fracture (FtF) Methodology for Cardiovascular Medical Devices, for example, outlines elegant methodologies for fatigue-to-fracture of cardiovascular medical devices. Some challenges that ensue, however, are apparent in exceptionally durable super-elastic alloys, like nitinol, where equipment limitations become rate limiting. Furthermore, once hyperphysiological loading levels are achieved, the subsequent challenge of fracture detection arises. Partnering with Dynatek Labs, Inc., Cook Medical presents a novel pulsatile fatigue testing platform capable of both applying hyperphysiological load levels, which induce fracture, as well as detecting fractures when they occur. Coupled with sophisticated statistical analysis projections, these pulsatile fatigue-to-fracture data align with cutting-edge standards like ASTM F3211 and provide confirmatory evidence of long-term permanent implant durability predictions associated with state-of-the-art standards of ASTM F2477 and ISO 25539-2.
- Open Access
- 28 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1326190
Dissection flap fenestration can reduce re-apposition force of the false lumen in type-B aortic dissection: a computational and bench study
Thoracic endovascular aortic repair (TEVAR) has been widely adopted as a standard for treating complicated acute and high-risk uncomplicated Stanford Type-B aortic dissections. The treatment redirects the blood flow towards the true lumen by covering the proximal dissection tear which promotes sealing of the false lumen. Despite advances in TEVAR, over 30% of Type-B dissection patients require additional interventions. This is primarily due to the presence of a persistent patent false lumen post-TEVAR that could potentially enlarge over time. We propose a novel technique, called slit fenestration pattern creation, which reduces the forces for re-apposition of the dissection flap (i.e., increase the compliance of the flap). We compute the optimal slit fenestration design using a virtual design of experiment (DOE) and demonstrate its effectiveness in reducing the re-apposition forces through computational simulations and benchtop experiments using porcine aortas. The findings suggest this potential therapy can drastically reduce the radial loading required to re-appose a dissected flap against the aortic wall to ensure reconstitution of the aortic wall (remodeling).
- 28 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1326190
Open AccessDissection flap fenestration can reduce re-apposition force of the false lumen in type-B aortic dissection: a computational and bench study
Thoracic endovascular aortic repair (TEVAR) has been widely adopted as a standard for treating complicated acute and high-risk uncomplicated Stanford Type-B aortic dissections. The treatment redirects the blood flow towards the true lumen by covering the proximal dissection tear which promotes sealing of the false lumen. Despite advances in TEVAR, over 30% of Type-B dissection patients require additional interventions. This is primarily due to the presence of a persistent patent false lumen post-TEVAR that could potentially enlarge over time. We propose a novel technique, called slit fenestration pattern creation, which reduces the forces for re-apposition of the dissection flap (i.e., increase the compliance of the flap). We compute the optimal slit fenestration design using a virtual design of experiment (DOE) and demonstrate its effectiveness in reducing the re-apposition forces through computational simulations and benchtop experiments using porcine aortas. The findings suggest this potential therapy can drastically reduce the radial loading required to re-appose a dissected flap against the aortic wall to ensure reconstitution of the aortic wall (remodeling).
- 29 October 2023
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 145, 105502
Range of the perfluorooctanoate (PFOA) safe dose for human health: An international collaboration
- 29 October 2023
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 145, 105502
Range of the perfluorooctanoate (PFOA) safe dose for human health: An international collaboration