Type
Company
Locations
Bjæverskov, Denmark
Relationships
Parent Organizations

Latest Publications

  • The current false lumen endograft and clinical experience for false lumen occlusion in chronic aortic dissection

    by Márton Berczeli, Björn Sonesson, John Mogensen, Angelos Karelis, Nuno V. Dias

    Article: The current false lumen endograft and clinical experience for false lumen occlusion in chronic aortic dissection - The Journal of Cardiovascular Surgery 2025 May 23 - Minerva Medica - Journals


  • Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results

    by Ahmed Eleshra, Tilo Kölbel, Nikolaos Tsilimparis, Giuseppe Panuccio, Martin Scheerbaum, E. Sebastian Debus, John Mogensen, Fiona Rohlffs

    Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid–LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3–12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.


  • Distribution of Air Embolization During TEVAR Depends on Landing Zone: Insights From a Pulsatile Flow Model

    by Vladimir Makaloski, Fiona Rohlffs, Constantin Trepte, E. Sebastian Debus, Bent Øhlenschlaeger, Jürg Schmidli, Tilo Kölbel

    Purpose: To analyze the distribution of air bubbles in the supra-aortic vessels during thoracic stent-graft deployment in zones 2 and 3 in an aortic flow model. Materials and Methods: Ten identical, investigational, tubular, thoracic stent-grafts were deployed in a glass aortic flow model with a type I arch: 5 in zone 2 and 5 in zone 3. A pulsatile pump generated a flow of 5 L/min with systolic and diastolic pressures (±5%) of 105 and 70 mm Hg, respectively. The flow rates (±5%) were 300 mL/min in the subclavian arteries, 220 mL/min in the vertebral arteries, and 400 mL/min in the common carotid arteries (CCAs). The total amounts of air released in each supra-aortic branch and in the aorta were recorded. Results: The mean amounts of air measured were 0.82±0.23 mL in the zone-2 group and 0.94±0.28 mL in the zone-3 group (p=0.49). In the zone-2 group compared with zone 3, the amounts of released air were greater in the right subclavian artery (0.07±0.02 vs 0.02±0.02 mL, p<0.01) and right CCA (0.30±0.8 vs 0.18±07 mL, p=0.04). There were no differences between the groups concerning the mean amounts of air measured in the right vertebral and all left-side supra-aortic branches. The amount of air released in the descending aorta was significantly higher in the zone-3 group vs the zone-2 group (0.48±0.12 vs 0.13±0.08 mL, p<0.01). Small bubbles were observed continuously during deployment, whereas large bubbles appeared more commonly during deployment of the proximal stent-graft end and after proximal release of the stent-graft. Conclusion: Air is released into all supra-aortic branches and the descending aorta during deployment of tubular thoracic stent-grafts in zones 2 and 3 in an aortic flow model. Higher amounts of air were observed in right-side supra-aortic branches during deployment in zone 2, whereas significantly greater amounts of air were observed in the descending aorta during deployment in zone 3.


  • False Lumen Occlusion in Chronic Aortic Dissection: The New Generation Candy-Plug II

    by Fiona Rohlffs, Nikolaos Tsilimparis, John Mogensen, Vladimir Makaloski, Sebastian Debus, Tilo Kölbel


  • Transapical Access for Antegrade Catheterization of the Inner Branches of an Arch Stent-Graft Deployed Distal to an Ascending Arch Stent-Graft

    by Yuk Law, Tilo Kölbel, Johannes Schirmer, Shadi Aleed, John Mogensen, E. Sebastian Debus, Christian Detter, Nikolaos Tsilimparis

    Propose: To describe a technique for antegrade cannulation and bridging of the supra-aortic branches through a transapical access in the treatment of an arch aneurysm using combined ascending and branched arch stent-grafts. Technique: An 81-year-old man with a past history of open infrarenal aortic repair, emergent endovascular aortic repair for thoracic aortic rupture, and later perivisceral 4-vessel branched endovascular repair of type I thoracoabdominal aneurysm presented for repair of a concomitant 7.5-cm arch aneurysm. Because of a 44-mm ascending aorta, a tapered 50/44-mm ascending stent-graft was delivered through a transapical access to establish an adequate landing zone before implantation of a 46-mm inner branched arch device via a transfemoral route. Innominate and left subclavian arteries were antegradely cannulated and bridged through the existing transapical path. Conclusion: Our case demonstrates the feasibility of transapical access for cannulation of an arch branched device, while introducing the theoretical possibility of completing the entire procedure through a transapical access.


  • Air Embolism During TEVAR: An Additional Flush Port on the Delivery System Pusher Significantly Reduces the Amount of Air Released During Deployment of a Thoracic Stent-Graft in an Experimental Setting

    by Fiona Rohlffs, Nikolaos Tsilimparis, Constantin Trepte, Jarin Kratzberg, John Mogensen, Eike Sebastian Debus, Tilo Kölbel

    Purpose: To investigate the influence of (1) an additional side port for flushing the hollow pusher in Zenith thoracic stent-graft delivery systems and (2) additional carbon dioxide flushing on the amount of air released during stent-graft deployment. Methods: Twenty thoracic stent-grafts with an additional flush port to fill the hollow pusher were separated into 2 equal groups (C and D). Both groups were flushed with 20 mL of normal saline through the extra side port connected to the pusher and with 60 mL of saline through the regular flushing port. One group of grafts (group D) was additionally flushed with carbon dioxide through the regular flushing port prior to saline. All grafts were deployed into a curved plastic pipe attached to the bottom of a water-filled container. The released gas was recorded and measured using a calibrated setup. To evaluate the influence of the extra side port irrespective of the carbon dioxide flushing technique, group C was compared with a previously published reference group A without an extra side port that was flushed with the standard 60 mL of saline. Results: Volumes of gas were released in various amounts from the stent-grafts during deployment. The average amount of released gas was 0.51 mL in group C and 0.07 mL in group D (p<0.001). The mean amount of gas from group C samples (0.51 mL) was also significantly lower (p=0.002) compared with the reference group (0.79 mL). Conclusion: Thoracic endografts release air during deployment. Reducing the air-filled space inside the pusher of the catheter assembly using an additional side port can significantly reduce the amount of released air. Using the extra side port in combination with the carbon dioxide flushing technique reduces gas release further to small volumes. In a clinical setting this could be a promising approach to lower the risk of air embolism and stroke during thoracic endovascular aortic repair.


  • Programming of glucose–insulin homoeostasis: long‐term consequences of pre‐natal versus early post‐natal nutrition insults. Evidence from a sheep model

    by A. H. Kongsted, M. P. Tygesen, S. V. Husted, M. H. Oliver, A. Tolver, V. G. Christensen, J. H. Nielsen, M. O. Nielsen

    Aim: Exposure to adverse intra‐uterine conditions can predispose for metabolic disorders later in life. By using a sheep model, we studied (i) how programming of glucose–insulin homoeostasis during late gestation is manifested later in life depending on the early post‐natal dietary exposure and (ii) whether dietary alteration in obese individuals can prevent adverse outcomes of early life programming.Methods: During late gestation, twin‐pregnant sheep were fed 100% (NORM) or 50% (LOW) of energy and protein requirements. After birth, offspring were exposed to a moderate (CONV) or high‐carbohydrate–high‐fat (HCHF) diet until around puberty. Offspring remaining thereafter (exclusively females) were fed a moderate diet until young adulthood.Results: LOW lambs had increased insulin secretory responses during intravenous glucose tolerance tests indicative of reduced insulin sensitivity. HCHF lambs were hypertriglyceridaemic, 75% had mild pancreatic collagen infiltration, and their acute insulin secretory response and insulin clearance during intravenous glucose and insulin tolerance tests, respectively, were reduced. However, NORM‐HCHF in contrast to LOW‐HCHF lambs had normal glucose tolerance, indicating that later health outcomes are highly influenced by pre‐natal nutrition. Dietary alteration normalized glucose–insulin homoeostasis in adult HCHF females, whereas late‐gestation undernutrition (LOW) permanently depressed insulin sensitivity.Conclusion: Maintenance of glucose tolerance in sheep exposed to pre‐natal undernutrition relied on pancreatic hypersecretion of insulin to compensate for reduced insulin sensitivity. A mismatching high‐fat diet in early post‐natal life interfered with this pancreatic hypersecretion resulting in reduced glucose tolerance. Early post‐natal, but not late pre‐natal, impacts on glucose–insulin homoeostasis could be reversed by dietary correction later in life.