Type
Company
Locations
Oxford, United Kingdom
Relationships

Latest Publications

  • Perpetual Pharmacy Inventory Management Systems: A Health-System Evaluation and Implementation Toolkit

    by Craig A Greszler, Shannon J Johnson, Jaclyn A Kilsgaard, Derek Rhodes, Kayleigh Thompson

    Purpose: Medication costs continue to rise across health systems, increasing the need for efficient and effective inventory management strategies. Perpetual pharmacy inventory management systems (IMS) provide continuous, real-time inventory tracking, yet adoption remains variable. This article describes a practical approach to support health systems in evaluating, selecting, implementing, and optimizing IMS. Summary: Three primary categories of IMS are reviewed: electronic health record–integrated solutions, software-only standalone inventory platforms, and systems incorporating hardware automation with their software. Key differences in functionality, integration requirements, scalability, and operational impact are described. The authors outline core benefits of IMS and practical considerations for purchasing decisions, implementation planning, system transitions, and ongoing governance. This article also addresses common challenges encountered during implementation, along with strategies to overcome these barriers. Finally, the applicability of IMS in non-traditional pharmacy and clinical settings is discussed. Conclusion: IMS can substantially improve inventory visibility, operational efficiency, and compliance when thoughtfully evaluated and implemented. This article provides a structured, practical framework to guide health systems in selecting and optimizing IMS to support safe, efficient, and sustainable medication-use processes.

  • Agile Approach to Hardware Design for Reliability

    by Andre Kleyner

    Agile methods were originally developed for software, but there has been growing interest in applying these principles to hardware, along with discussions about the associated methods and challenges in hardware-centric product development. This paper presents an approach to Agile hardware development with a focus on achieving high product reliability. The approach is grounded in the author’s experience developing electronic products for harsh environments, such as those found in the automotive, defense, aerospace, and oil and gas industries. Specifically, the paper explores the application of Agile principles to reliability engineering and the process commonly known as Design for Reliability (DfR). To illustrate the concepts without loss of generality, examples are drawn from electronic controllers designed for demanding operational conditions typical of the industries mentioned.

  • NK cell dysregulation in the multiple myeloma: insights from multi-modal profiling of the bone marrow microenvironment 2812

    by Siobhán B. Cashman, Aruna Ayer, Teresa Swift

    Description: : Innate immune cells (NK & NK-T-like cells) are important effector cells for anti-tumor responses in multiple myeloma (MM), a hematological malignancy where clonal plasma cells expand in the bone marrow (BM). There is a disjointed picture of the NK cell phenotype in the MM tumor microenvironment (TME). Using a combination of traditional flow cytometry, spectral flow cytometry, & single-cell RNA sequencing with the addition of CITE-seq, we sought to gain a greater understanding of NK cells in the TME of MM patients by sampling BM from healthy and newly diagnosed cohorts. We observed an increase in total NK cells, but a decrease in the CD56DimCD16+ NK cell subset. CD56DimCD16+ NK cells displayed a more mature, terminally differentiated phenotype in MM compared to controls. Further, we report that CD158a & CD158f were altered within this subset. Additional characterization of CD57+ NK cells, increased in MM, found that this subset was enriched in high frequencies of KIR-expressing cells & granzyme transcripts. This study illustrated the profiles of NK cells in the BM immune cell microenvironment using flow cytometry and CITE-seq. This methodology facilitated the integration of surface marker expression with corresponding gene expression patterns, providing a robust framework for analyzing the TME. For Research-Use Only. Not for use in diagnostic or therapeutic procedures. BD and the BD Logo are trademarks of Becton, Dickinson and Company. © 2024 BD. All rights reserved. NPM-5211 Topic Categories: Tumor Immunology: Cellular Responses and Tumor Microevironment (TIME)

  • Mapping the cytotoxic landscape: an integrated analysis of T cell heterogeneity in the bone marrow microenvironment of multiple myeloma 2810

    by Siobhán B. Cashman, Aruna Ayer, Teresa Swift

    Description: : Multiple Myeloma (MM) is characterized by the clonal proliferation of plasma cells in the bone marrow (BM), which serves as the tumor microenvironment (TME). Despite treatment advances, MM remains incurable. Therefore, understanding the cytotoxic T-cell component of the TME may enable the development of better-targeted therapies. We characterized the cytotoxic T cells from the BM of MM & healthy cohorts using flow cytometry & single-cell RNA sequencing (scRNA-seq) with CITE-seq, enabling the high-resolution analysis of surface protein & transcriptomic changes within individual cells. We identified an expanded population of CD57+ cytotoxic T cells. This CD57+ subset had reduced expression of CD28 & did not express common exhaustion markers. These cells exhibited a bias towards polyfunctionality, however, both transcript & protein were expressed at lower levels than controls. Furthermore, scRNA-seq revealed enrichment of perforin & granzyme transcripts, further supporting the finding of a senescent cell with high cytotoxic potential. By combining flow cytometry with scRNA-seq & CITE-seq, this study mapped the changes in the BM TME. This approach allowed us to link surface marker expression with gene expression profiles, enabling a comprehensive analysis of the CD8+ T cells in TME of MM patients. For Research-Use Only. Not for use in diagnostic or therapeutic procedures. BD and the BD Logo are trademarks of Becton, Dickinson and Company. © 2024 BD. All rights reserved. NPM-5210 Topic Categories: Tumor Immunology: Cellular Responses and Tumor Microevironment (TIME)

  • Open Access

    Enhancing blood culture volume with ultrathin-wall cannula devices

    by Grant Johnson, Valentin Parvu, Stephane Beauchamp, Mike Cuttler, Arek Zubrzycki, Lauren Cooper

    Suboptimal blood volume collection negatively affects pathogen recovery and time to pathogen detection in clinical blood culture samples. This study evaluated the performance of the ultrathin-wall cannula device of the BD Vacutainer UltraTouch Push Button Blood Collection Set (UltraTouch; BD Life Sciences, Franklin Lakes, NJ) in increasing the blood volume collected compared to regular cannulas. In this retrospective study, the volume of blood collected in negative BD BACTEC Plus Aerobic/F Culture Vials prior to and following blind conversion to UltraTouch was measured from blood background metabolic activity signal acquired during the initial incubation period in the BD BACTEC FX instrument using a custom software application (patent pending). Differences in average fill volume between pre- and post-conversion were evaluated overall and by month. A separate logistic regression was also performed to model the relationship between monthly average blood volume increase (mL) and sample positivity rate. Prevalence rates for identified organisms were also assessed. The blood fill volume of 13,356 pre-conversion and 119,971 post-conversion bottles was compared. The average post-conversion fill volume was significantly higher than that of pre-conversion (7.56 mL [95% CI, 7.54–7.59] vs. 5.68 mL [95% CI, 5.62–5.74], respectively). This 1.88 mL increase in collected blood volume increased sample positivity from 7.0% to 7.7% ( P = 0.002; odds ratio [OR], 1.11; 95% CI, 1.04–1.19). This study demonstrated that using an ultrathin-wall cannula blood collection device can significantly increase blood culture volume and sample positivity, supporting improved identification of patients suffering from bloodstream infections. IMPORTANCE: Substandard blood fill volume practices in clinical settings negatively affect pathogen recovery which, in turn, may impact patients’ care. Whereas professional education regarding the importance of adhering to clinical guidelines has been helpful in partly remediating the issue, the role of blood collection set technologies in optimizing blood culture volume has not been studied as thoroughly. Our study assessed the performance of the BD Vacutainer UltraTouch Push Button Blood Collection Set, which is designed with an ultrathin-wall cannula, to improve blood culture volume.

  • Open Access

    Improved time-to-detection with the new formulation of BD BACTEC Plus Aerobic/F Culture Vials: a real-world evidence study

    by Kayla Van Benten, Mondraya Howard, Valentin Parvu, Chris Massey, Stephanie Frey

    BD BACTEC Plus Aerobic/F Culture Vials were modified to reduce time-to-detection (TTD) of bacteria and yeast in blood specimens. Analytical testing involved seeded blood specimens in either predicate plus (N = 500) and modified plus (N = 500) media. Clinical testing used positive aerobic vial results from BD EpiCenter System Software for two periods: predicate plus (N = 1,075) and modified plus medium (N = 873). TTD was measured from the start of vial incubation to microorganism growth detection on BD BACTEC FX. Wilcoxon rank-sum and Chi-square (χ²) tests were used to compare TTD and 48-hour positivity. Modified plus reduced TTD by 2.6 hours ( P < 0.001) in analytical testing and 2.9 hours ( P < 0.05) in clinical testing. Significant TTD reductions were observed for E. coli , E. faecalis , S. epidermidis , and P. mirabilis . The incidence of late positives (detection after 48 hours) decreased from 10.5% to 6.9%. Modified plus media significantly reduces TTD and the number of late positives for a range of microorganisms. IMPORTANCE: Faster detection of infectious organisms can help improve patient prognosis. Recently, the formulation of aerobic culture vial media was modified for blood culture on the BD BACTEC instrument. The work presented here provides compelling evidence that the new aerobic media formulation improves time-to-detection for bloodstream infections. This has the potential to impact the healthcare treatment of millions of patients each year without requiring changes in clinical workflow. Faster time to detection can lead to faster organism identification and antimicrobial susceptibility testing (when appropriate). This report provides a comprehensive comparison of the novel media formulation with the predicate formulation for detecting multiple organism genera in both analytical and prospective clinical studies.

  • Open Access

    Enhancing medication adherence with blister-packed oral oncolytics: A case example in chronic lymphocytic leukemia

    by Eric P. Borrelli, Nathan Barnes, Heather Nelkin, Peter Saad, Doina Dumitru, Julia D. Lucaci

    Introduction: Medication nonadherence is a prevalent issue in the oncology population and can be costly on the healthcare system while leading to worsened outcomes, including increased mortality. One intervention that has been shown to help promote medication adherence to oral therapies for chronic conditions is blister-packaging. However, no literature is available assessing the potential impact of blister-packaging in oncology. Therefore, we aimed to quantify the impact of blister-packaging oral oncolytics on medication adherence and healthcare costs. Methods: An economic model was designed to assess the potential impact of blister-packaging oral oncolytics for chronic lymphocytic leukemia (CLL) patients in the U.S. The model took the perspective of the U.S. healthcare system and assessed newly diagnosed CLL cases initiating therapy, utilizing a one-year time horizon. The intervention of interest was blister-packaging oral therapies in the treatment of CLL, while the model evaluated the impact of this intervention on healthcare costs through improved patient adherence based on peer-reviewed literature. Results: This analysis consisted of 20,700 newly diagnosed patients with CLL initiating therapy. Initiating blister-packed oral therapies saw adherence increase by 1004 patients from 12,979 patients (62.7%) to 13,983 patients (67.5%). While an increase in pharmacy costs by $61,589,670 (+$247.95 per-patient per-month (PPPM)) was seen for the population, medical costs decreased by $82,285,847 (-$331.26 PPPM). Overall, this led to a net reduction in total healthcare costs of $20,696,177 (-$83.32 PPPM). Conclusions: Blister-packaging oral oncology drugs in CLL has the potential to reduce total healthcare expenditures by increasing medication adherence. Future studies are needed to evaluate the direct effects of blister-packaging oral oncolytics on clinical, healthcare resource utilization, and financial outcomes.

  • Top Cited Papers
    Open Access

    Mortality and morbidity after total intravenous anaesthesia versus inhalational anaesthesia: a systematic review and meta-analysis

    by Jasper M. Kampman, Jeroen Hermanides, Markus W. Hollmann, Coenraad N. Gilhuis, Wouter Ah. Bloem, Stefan Schraag, Lorenzo Pradelli, Sjoerd Repping, Nicolaas H. Sperna Weiland


  • To Fall is Not to Fail

    by Emma Rondele Quentin

  • Open Access

    Burden of invasive pneumococcal disease, non-invasive all-cause pneumonia, and acute otitis media in hospitalized US children: a retrospective multi-center study from 2015-2020

    by Salini Mohanty, Nicole Cossrow, Meghan White, Kalvin C. Yu, Gang Ye, Kristen A. Feemster, Vikas Gupta

    Background Despite effective pneumococcal vaccines, pneumococcal disease (PD) exerts a substantial burden on children. This study explored the clinical and economic burden of invasive PD (IPD), non-invasive all-cause pneumonia (ACP), and acute otitis media (AOM) in hospitalized children, including those with antibiotic-resistant Streptococcus pneumoniae. Methods Data from the BD Insights Research Database of hospitalized children (<18 years) in the US were analyzed retrospectively. The study cohort included patients with an ICD10 code for IPD, ACP, or AOM and/or a positive culture for S. pneumoniae. Descriptive statistics and multivariable analyses evaluated the following outcomes: length of stay [LOS], hospital cost per admission, hospital margin per admission [costs – payments], and in-hospital mortality. Results The study included 4575 pediatric patients with IPD, ACP, or AOM admitted to 57 US hospitals from October 2015 to February 2020. Approximately half (50.7%) were under 2 years of age. The in-hospital mortality rate was 0.6% (n=28). The observed median (interquartile range) LOS was 4 (3, 5) days, cost per admission was $4,240 ($2,434, $8,311) US dollars, and hospital margin per admission was -$63 (‑$2,118, $2,025). Forty-one patients had S. pneumoniae-positive cultures and 56.1% of those cultures were resistant to ≥1 antibiotic class. Key variables associated with poor outcomes were having a moderate- or high-risk condition (chronic or immunocompromising), intensive care unit admission, and prior 90-day admission. Conclusions IPD, ACP, and AOM are associated with substantial clinical and economic burden in hospitalized pediatric patients in the US. S. pneumoniae isolates also showed high rates of resistance to antibiotics. Our data indicate the need for ongoing prevention efforts including vaccination and antimicrobial stewardship programs.