Carolina Eyecare Physicians
Type
HealthcareLocations
Mt. Pleasant, United StatesLatest Publications
- 26 July 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
A Comparative Time-Based Profit Analysis of Retinal and Cataract Surgery in Ambulatory Surgery Centers
Purpose: To evaluate the time-adjusted economics of retinal and cataract surgery in order to clarify how the dynamics of ambulatory surgery centers influence access to urgent care. Methods: A time-driven activity-based costing model integrating Centers for Medicare & Medicaid Services ambulatory surgery center reimbursement, intraservice times, and cost data from a provider was applied to 18 421 retinal and 880 448 cataract procedures (2021–2024). Reimbursement, cost, and profit were converted to per-minute values, and a financial efficiency coefficient was used to quantify time-adjusted profitability. Variation in time and overhead allocation was assessed with sensitivity analyses. Results: Retinal procedures required 76.1 minutes vs 20.8 minutes for cataract surgery (ratio, 3.65). Time-normalized metrics favored cataract surgery, with reimbursement, cost, and profits per minute of $52.63, $29.28, and $23.35, compared with retinal procedures’ $24.61, $16.22, and $8.40. The profit per minute for retinal procedures was 36% of the cataract profit. The financial efficiency coefficient was 0.098, indicating retinal surgery was less than 10% efficient after adjusting for operative duration. Parity would require reducing operative time to 7.5 minutes or increasing reimbursement by $61.05 per minute (~71%). No retinal Current Procedural Terminology code achieved a financial efficiency coefficient ≥1. Block modeling showed adding 2 retinal cases to a cataract block converted a margin to a loss, with retinal blocks generating losses approaching $5,908. Conclusions: Although ambulatory surgery center reimbursement was higher for retinal than cataract surgery and the cost per minute was lower for retinal surgery, cataract surgery was more profitable per minute. These findings underscore the need for reform of time-based reimbursement that reflects the complexity of retinal surgery.
- 26 July 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
A Comparative Time-Based Profit Analysis of Retinal and Cataract Surgery in Ambulatory Surgery Centers
Purpose: To evaluate the time-adjusted economics of retinal and cataract surgery in order to clarify how the dynamics of ambulatory surgery centers influence access to urgent care. Methods: A time-driven activity-based costing model integrating Centers for Medicare & Medicaid Services ambulatory surgery center reimbursement, intraservice times, and cost data from a provider was applied to 18 421 retinal and 880 448 cataract procedures (2021–2024). Reimbursement, cost, and profit were converted to per-minute values, and a financial efficiency coefficient was used to quantify time-adjusted profitability. Variation in time and overhead allocation was assessed with sensitivity analyses. Results: Retinal procedures required 76.1 minutes vs 20.8 minutes for cataract surgery (ratio, 3.65). Time-normalized metrics favored cataract surgery, with reimbursement, cost, and profits per minute of $52.63, $29.28, and $23.35, compared with retinal procedures’ $24.61, $16.22, and $8.40. The profit per minute for retinal procedures was 36% of the cataract profit. The financial efficiency coefficient was 0.098, indicating retinal surgery was less than 10% efficient after adjusting for operative duration. Parity would require reducing operative time to 7.5 minutes or increasing reimbursement by $61.05 per minute (~71%). No retinal Current Procedural Terminology code achieved a financial efficiency coefficient ≥1. Block modeling showed adding 2 retinal cases to a cataract block converted a margin to a loss, with retinal blocks generating losses approaching $5,908. Conclusions: Although ambulatory surgery center reimbursement was higher for retinal than cataract surgery and the cost per minute was lower for retinal surgery, cataract surgery was more profitable per minute. These findings underscore the need for reform of time-based reimbursement that reflects the complexity of retinal surgery.
- 11 June 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 10 (6) , 1132-1137
Operating Room Access: Survey of the American Society of Retina Specialists
Purpose: To evaluate vitreoretinal surgeons’ access to operating rooms and potential barriers to care. Methods: An electronic survey of the American Society of Retina Specialists was performed in 2025. Results: Of the 276 respondents, most (90% [248]) were concerned about obtaining sufficient operating room time, with more than half (54% [150]) reporting increased difficulty accessing hospital operating rooms even during the weekdays and 45% (124) reporting increased difficulty accessing hospital operating rooms at nights and weekends. The most common reasons for limited access to operating rooms included block time/scheduling conflicts (61% [169]), anesthesia limitations (59% [162]), staffing limitations (51% [142]), and lower relative reimbursements for vitreoretinal surgeries (45% [125]). Most surgeons (94% [259]) believed that restricting operating room access adversely impacted patient care, leading to delays for urgent retinal detachment repairs (77% [212]), increased travel burden for patients (62% [170]), and worse patient outcomes (41% [113]). Patients treated in lower socioeconomic areas had to travel farther for surgery (median of 19 vs 9 miles for ambulatory surgery centers, P < .001, and 17 vs 9 miles for hospitals, P < .001). Practices have compensated by relying more on in-office procedures (46% [128]) and referrals to academic centers (39% [108]). Conclusions: Vitreoretinal surgeons were concerned about access restrictions to operating rooms and the potential impact on patients. Potential reasons for limited operating room access were likely multifactorial but included limited block time, restrictions in anesthesia and staff availability, and lower relative surgical reimbursements.
- 11 June 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 10 (6) , 1132-1137
Operating Room Access: Survey of the American Society of Retina Specialists
Purpose: To evaluate vitreoretinal surgeons’ access to operating rooms and potential barriers to care. Methods: An electronic survey of the American Society of Retina Specialists was performed in 2025. Results: Of the 276 respondents, most (90% [248]) were concerned about obtaining sufficient operating room time, with more than half (54% [150]) reporting increased difficulty accessing hospital operating rooms even during the weekdays and 45% (124) reporting increased difficulty accessing hospital operating rooms at nights and weekends. The most common reasons for limited access to operating rooms included block time/scheduling conflicts (61% [169]), anesthesia limitations (59% [162]), staffing limitations (51% [142]), and lower relative reimbursements for vitreoretinal surgeries (45% [125]). Most surgeons (94% [259]) believed that restricting operating room access adversely impacted patient care, leading to delays for urgent retinal detachment repairs (77% [212]), increased travel burden for patients (62% [170]), and worse patient outcomes (41% [113]). Patients treated in lower socioeconomic areas had to travel farther for surgery (median of 19 vs 9 miles for ambulatory surgery centers, P < .001, and 17 vs 9 miles for hospitals, P < .001). Practices have compensated by relying more on in-office procedures (46% [128]) and referrals to academic centers (39% [108]). Conclusions: Vitreoretinal surgeons were concerned about access restrictions to operating rooms and the potential impact on patients. Potential reasons for limited operating room access were likely multifactorial but included limited block time, restrictions in anesthesia and staff availability, and lower relative surgical reimbursements.
- 1 June 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (6) , 574-581
Comparison of visual and subjective outcomes between two EDOF intraocular lenses, with emphasis on mesopic performance
Purpose: To evaluate outcomes after implantation of 2 extended depth-of-focus intraocular lenses (IOLs), with emphasis on performance in dim light. Setting: 2 clinical practices in the United States. Design: Prospective, double-masked, randomized clinical trial. Methods: Participants were randomized to receive Symfony Optiblue or Vivity IOLs. Objective optical quality, aberrations, and simulated visual disturbances were measured before and 3 months postoperatively. Binocular visual acuity (VA), the defocus curve, and low contrast VA were measured under mesopic lighting conditions. Patient questionnaires were administered, and undirected patient comments were recorded. Results: 31 participants in each group completed the study. Refractive outcomes were not significantly different. The Symfony lens provided about a half line better monocular mesopic VA at distance when uncorrected and best corrected ( P < .05). There were no differences in binocular visual function between lenses except for the mesopic defocus curve at −1.00 diopters (D) and −1.50 D, with the Symfony lens providing better VA at those vergences ( P < .02). Objective optical measures improved after surgery, with improvements not different by group. There were no differences in the size or intensity of simulated glare, but simulated halos and starburst size and intensity were significantly worse with the Symfony lens ( P < .05). Satisfaction with distance and intermediate vision in both groups was high. Reported visual disturbances were not significantly different between groups. Conclusions: The 2 lenses provided similar visual performance in dim light, with the Symfony lens showing slightly better VA, but with more reports of halos and starbursts.
- 1 June 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (6) , 574-581
Comparison of visual and subjective outcomes between two EDOF intraocular lenses, with emphasis on mesopic performance
Purpose: To evaluate outcomes after implantation of 2 extended depth-of-focus intraocular lenses (IOLs), with emphasis on performance in dim light. Setting: 2 clinical practices in the United States. Design: Prospective, double-masked, randomized clinical trial. Methods: Participants were randomized to receive Symfony Optiblue or Vivity IOLs. Objective optical quality, aberrations, and simulated visual disturbances were measured before and 3 months postoperatively. Binocular visual acuity (VA), the defocus curve, and low contrast VA were measured under mesopic lighting conditions. Patient questionnaires were administered, and undirected patient comments were recorded. Results: 31 participants in each group completed the study. Refractive outcomes were not significantly different. The Symfony lens provided about a half line better monocular mesopic VA at distance when uncorrected and best corrected ( P < .05). There were no differences in binocular visual function between lenses except for the mesopic defocus curve at −1.00 diopters (D) and −1.50 D, with the Symfony lens providing better VA at those vergences ( P < .02). Objective optical measures improved after surgery, with improvements not different by group. There were no differences in the size or intensity of simulated glare, but simulated halos and starburst size and intensity were significantly worse with the Symfony lens ( P < .05). Satisfaction with distance and intermediate vision in both groups was high. Reported visual disturbances were not significantly different between groups. Conclusions: The 2 lenses provided similar visual performance in dim light, with the Symfony lens showing slightly better VA, but with more reports of halos and starbursts.
- 7 May 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 10 (5) , 1023-1028
Comparison of Medicaid Vs Medicare Reimbursement Rates for Vitreoretinal Surgeries in the United States
Purpose: To compare the Medicaid and Medicare physician reimbursement rates for the top 10 most common vitreoretinal surgeries. Methods: The Medicaid-to-Medicare reimbursement ratios were compared for the most frequently used Common Procedural Terminology (CPT) codes, adjusted for each state’s proportion of Medicaid enrollment in the United States. Results: The most used CPT codes were 67042 (26%), 67036 (20%), 67108 (17%), 67041 (11%), 67113 (11%), 67040 (6.5%), 67039 (4.1%), 67121 (2.8%), 67218 (0.44%), and 67107 (0.43%). The weighted average (±SD) of the Medicaid reimbursement rate was 88% ± 2.3% of the Medicare rates. New Jersey had the lowest Medicaid-to-Medicare ratio (52% ± 2.33% of all Medicaid enrollees). Thirty-six states, comprising 80% of all US Medicaid enrollees, had lower Medicaid than Medicare rates; 30 of those states had lesser-of policies, under which physicians would be reimbursed at the lower Medicaid rates despite patients being dually enrolled in both Medicaid and Medicare. Conclusions: There were significant variations between states, but Medicaid reimbursements were on average 12% lower than Medicare rates. In most states, there was a significant opportunity cost for the physician performing the same surgery on a patient with Medicaid compared with Medicare. State governments should work to improve patient access to care, match the Medicaid and Medicare rates, and eliminate lesser-of payment policies.
- 7 May 2026
- Published by SAGE Publications in Journal of Vitreoretinal Diseases
- Vol. 10 (5) , 1023-1028
Comparison of Medicaid Vs Medicare Reimbursement Rates for Vitreoretinal Surgeries in the United States
Purpose: To compare the Medicaid and Medicare physician reimbursement rates for the top 10 most common vitreoretinal surgeries. Methods: The Medicaid-to-Medicare reimbursement ratios were compared for the most frequently used Common Procedural Terminology (CPT) codes, adjusted for each state’s proportion of Medicaid enrollment in the United States. Results: The most used CPT codes were 67042 (26%), 67036 (20%), 67108 (17%), 67041 (11%), 67113 (11%), 67040 (6.5%), 67039 (4.1%), 67121 (2.8%), 67218 (0.44%), and 67107 (0.43%). The weighted average (±SD) of the Medicaid reimbursement rate was 88% ± 2.3% of the Medicare rates. New Jersey had the lowest Medicaid-to-Medicare ratio (52% ± 2.33% of all Medicaid enrollees). Thirty-six states, comprising 80% of all US Medicaid enrollees, had lower Medicaid than Medicare rates; 30 of those states had lesser-of policies, under which physicians would be reimbursed at the lower Medicaid rates despite patients being dually enrolled in both Medicaid and Medicare. Conclusions: There were significant variations between states, but Medicaid reimbursements were on average 12% lower than Medicare rates. In most states, there was a significant opportunity cost for the physician performing the same surgery on a patient with Medicaid compared with Medicare. State governments should work to improve patient access to care, match the Medicaid and Medicare rates, and eliminate lesser-of payment policies.
- Open Access
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Myopic and Astigmatic Laser in situ Keratomileusis Using a Ray Tracing−Based Treatment Algorithm with a Personalized Ablation Profile
Purpose: Evaluate the safety and efficacy of ray tracing‒based LASIK surgery to correct myopia in eyes with and without astigmatism. Patients and Methods: This prospective study included adults with myopia up to − 10.00 D, with or without astigmatism (NCT04219891). For each eye, a 3D virtual model and personalized ablation profile were developed using data from InnovEyes™ Sightmap and ray-tracing algorithm, followed by a wavelight plus LASIK treatment. Efficacy endpoints included percentage of eyes achieving manifest refraction spherical equivalent (MRSE) within 1.00 and 0.50 D of emmetropia at refractive stability and uncorrected distance visual acuity (UDVA) assessments. Follow-up was up to 12 months. Safety endpoints included percentage of eyes that lost ≥ 2 lines corrected distance visual acuity (CDVA) at refractive stability versus preoperative CDVA and non‒flap-related ocular serious adverse events (SAEs). Mean optical aberrations were assessed. Dry eye symptoms were evaluated using ocular surface disease index scores. Patient-reported outcomes were assessed using Patient-Reported Outcomes With LASIK questionnaire. Results: A total of 163 patients (326 eyes) completed the study. Refractive stability was achieved at 3 months; during a 1- to 3-month interval, 99.4% of eyes had ≤ 1.00 D change in MRSE. MRSE within 0.50 and 1.00 D of emmetropia was achieved in 92.0% and 98.5% of eyes. At 12 months, 94.4% of eyes achieved UDVA of 20/20 or better. No eyes lost ≥ 2 lines of CDVA; no ocular SAEs or non-ocular adverse device effects were reported. Slight increase in coma (0.086 μm) and decrease in spherical aberration (− 0.030 μm) were reported at 12 months. Dry eye symptoms improved after procedure (preoperative, 14.90± 13.07; 12 months, 7.69± 8.12). Postoperatively, 98% of patients reported being very/completely satisfied with their vision. Conclusion: Ray tracing‒guided LASIK treatment was safe and effective for correcting myopia in individuals with and without astigmatism, producing stable visual outcomes and high satisfaction.
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-12
Open AccessMyopic and Astigmatic Laser in situ Keratomileusis Using a Ray Tracing−Based Treatment Algorithm with a Personalized Ablation Profile
Purpose: Evaluate the safety and efficacy of ray tracing‒based LASIK surgery to correct myopia in eyes with and without astigmatism. Patients and Methods: This prospective study included adults with myopia up to − 10.00 D, with or without astigmatism (NCT04219891). For each eye, a 3D virtual model and personalized ablation profile were developed using data from InnovEyes™ Sightmap and ray-tracing algorithm, followed by a wavelight plus LASIK treatment. Efficacy endpoints included percentage of eyes achieving manifest refraction spherical equivalent (MRSE) within 1.00 and 0.50 D of emmetropia at refractive stability and uncorrected distance visual acuity (UDVA) assessments. Follow-up was up to 12 months. Safety endpoints included percentage of eyes that lost ≥ 2 lines corrected distance visual acuity (CDVA) at refractive stability versus preoperative CDVA and non‒flap-related ocular serious adverse events (SAEs). Mean optical aberrations were assessed. Dry eye symptoms were evaluated using ocular surface disease index scores. Patient-reported outcomes were assessed using Patient-Reported Outcomes With LASIK questionnaire. Results: A total of 163 patients (326 eyes) completed the study. Refractive stability was achieved at 3 months; during a 1- to 3-month interval, 99.4% of eyes had ≤ 1.00 D change in MRSE. MRSE within 0.50 and 1.00 D of emmetropia was achieved in 92.0% and 98.5% of eyes. At 12 months, 94.4% of eyes achieved UDVA of 20/20 or better. No eyes lost ≥ 2 lines of CDVA; no ocular SAEs or non-ocular adverse device effects were reported. Slight increase in coma (0.086 μm) and decrease in spherical aberration (− 0.030 μm) were reported at 12 months. Dry eye symptoms improved after procedure (preoperative, 14.90± 13.07; 12 months, 7.69± 8.12). Postoperatively, 98% of patients reported being very/completely satisfied with their vision. Conclusion: Ray tracing‒guided LASIK treatment was safe and effective for correcting myopia in individuals with and without astigmatism, producing stable visual outcomes and high satisfaction.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 578-584
Clinical performance after implantation of an EDOF intraocular lens in the dominant eye and a presbyopia-correcting intraocular lens in the nondominant eye
Purpose: To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL). Setting: 2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States. Design: Prospective, unmasked, multicenter, nonrandomized bilateral eye study. Methods: Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function. Results: Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to −2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were “completely” or “mostly” satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as “excellent” or “good” by 92% (34/37) of participants. Conclusions: This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 578-584
Clinical performance after implantation of an EDOF intraocular lens in the dominant eye and a presbyopia-correcting intraocular lens in the nondominant eye
Purpose: To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL). Setting: 2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States. Design: Prospective, unmasked, multicenter, nonrandomized bilateral eye study. Methods: Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function. Results: Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to −2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were “completely” or “mostly” satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as “excellent” or “good” by 92% (34/37) of participants. Conclusions: This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.
- Open Access
- 1 December 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3693-3702
Comparing Visual Performance and Subjective Outcomes with an Enhanced Monofocal Intraocular Lens When Targeted for Emmetropia or Monovision
Purpose: To evaluate relative visual performance and subjective outcomes after implantation of the TECNIS Eyhance™ intraocular lens (IOL) targeted for bilateral emmetropia or monovision. Methods: This was a prospective, single-center randomized, patient-masked trial. Patients were implanted with the enhanced IOL targeted for bilateral emmetropia or slight monovision (− 0.75 D in the non-dominant eye). At 3 months the binocular visual acuity (VA) was measured at distance, intermediate and near, along with low contrast VA in photopic and mesopic conditions, and the distance corrected defocus curve. Questionnaires related to spectacle independence, satisfaction, visual symptoms, and functional vision were administered. Results: Data from 71 subjects (34 Emmetropia, 37 Monovision) were analyzed. There was no difference in the mean uncorrected distance VA (p = 0.11), but uncorrected intermediate and near VAs were one line better in the Monovision group (p = 0.02 and 0.01, respectively). Mesopic and photopic low contrast VA were similar between groups. There was a trend for less difficulty and higher satisfaction with near and intermediate vision in the Monovision group, but no significant differences in any of the subjective questionnaires. Difficulty reading was the most reported concern in both groups, though 93% of all subjects reported “little” or “no” difficulty with daily activities. Overall, 82% of subjects were “completely” or “very” happy with their lens choice. Conclusion: Using this enhanced IOL with slight monovision in the non-dominant eye increased intermediate and near VA with no apparent effect on low contrast distance VA, subjective visual quality, or satisfaction.
- 1 December 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3693-3702
Open AccessComparing Visual Performance and Subjective Outcomes with an Enhanced Monofocal Intraocular Lens When Targeted for Emmetropia or Monovision
Purpose: To evaluate relative visual performance and subjective outcomes after implantation of the TECNIS Eyhance™ intraocular lens (IOL) targeted for bilateral emmetropia or monovision. Methods: This was a prospective, single-center randomized, patient-masked trial. Patients were implanted with the enhanced IOL targeted for bilateral emmetropia or slight monovision (− 0.75 D in the non-dominant eye). At 3 months the binocular visual acuity (VA) was measured at distance, intermediate and near, along with low contrast VA in photopic and mesopic conditions, and the distance corrected defocus curve. Questionnaires related to spectacle independence, satisfaction, visual symptoms, and functional vision were administered. Results: Data from 71 subjects (34 Emmetropia, 37 Monovision) were analyzed. There was no difference in the mean uncorrected distance VA (p = 0.11), but uncorrected intermediate and near VAs were one line better in the Monovision group (p = 0.02 and 0.01, respectively). Mesopic and photopic low contrast VA were similar between groups. There was a trend for less difficulty and higher satisfaction with near and intermediate vision in the Monovision group, but no significant differences in any of the subjective questionnaires. Difficulty reading was the most reported concern in both groups, though 93% of all subjects reported “little” or “no” difficulty with daily activities. Overall, 82% of subjects were “completely” or “very” happy with their lens choice. Conclusion: Using this enhanced IOL with slight monovision in the non-dominant eye increased intermediate and near VA with no apparent effect on low contrast distance VA, subjective visual quality, or satisfaction.
- Open Access
- 1 October 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3089-3102
Multi-Frequency RF Combined with Intense Pulsed Light Improves Signs and Symptoms of Dry Eye Disease Due to Meibomian Gland Dysfunction
Purpose: To evaluate the efficacy of multi-frequency RF and IPL + MGX combination for treatment of Meibomian Gland Dysfunction (MGD). Patients and Methods: Eligible subjects had signs and moderate-to-severe symptoms of DED (Dry Eye Disease) due to MGD. Subjects underwent 4 treatments at 2-week intervals. Each treatment consisted of intense pulsed light (IPL) followed by radiofrequency (RF) on the periocular skin, followed by meibomian gland expression (MGX). The main outcome measure was the quality of meibum in 15 meibomian glands along the lower eyelid, using the modified Meibomian Gland Score (mMGS). The main hypothesis was a reduction of mMGS between the baseline (BL) and the follow-up (FU). Other outcome measures, such as symptoms measured with the OSDI (Ocular Surface Disease Index) questionnaire, meibography, non-invasive tear break-up time (NIBUT), and matrix metallopeptidase 9 (MMP-9) levels in tear samples were evaluated as well. Results: 31 subjects completed the FU. Between BL and FU, mMGS decreased from 30.4 (8.5) to 9.3 (9.5) (− 69.3%, 95% CI: − 55.6% to − 82.9%, p< 0.0001); OSDI decreased from 63.6 (17.2) to 25.0 (20.6) (− 60.7%, 95% CI: − 47.8% to − 73.5%, p< 0.0001); NIBUT did not change (p=0.92). An adjusted model with a historical control was constructed to allow the comparison of these subjects with those treated similarly with IPL+MGX (but without RF) in a different study. This analysis identified that the change in mMGS was larger when RF was included (− 20.9 vs − 18.3, adjusted p-value (p_adjusted) < 0.05). The difference in OSDI change was not significant (− 38.1 vs − 25.5, p_adjusted = 0.196). Conclusion: Combination of multi-frequency RF and IPL+MGX improves signs and symptoms of MGD. In comparison to a historical control, improvements were generally larger. A randomized controlled study comparing the combination of RF and IPL+MGX with IPL+MGX alone is required to further elaborate the relative contribution of RF.
- 1 October 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3089-3102
Open AccessMulti-Frequency RF Combined with Intense Pulsed Light Improves Signs and Symptoms of Dry Eye Disease Due to Meibomian Gland Dysfunction
Purpose: To evaluate the efficacy of multi-frequency RF and IPL + MGX combination for treatment of Meibomian Gland Dysfunction (MGD). Patients and Methods: Eligible subjects had signs and moderate-to-severe symptoms of DED (Dry Eye Disease) due to MGD. Subjects underwent 4 treatments at 2-week intervals. Each treatment consisted of intense pulsed light (IPL) followed by radiofrequency (RF) on the periocular skin, followed by meibomian gland expression (MGX). The main outcome measure was the quality of meibum in 15 meibomian glands along the lower eyelid, using the modified Meibomian Gland Score (mMGS). The main hypothesis was a reduction of mMGS between the baseline (BL) and the follow-up (FU). Other outcome measures, such as symptoms measured with the OSDI (Ocular Surface Disease Index) questionnaire, meibography, non-invasive tear break-up time (NIBUT), and matrix metallopeptidase 9 (MMP-9) levels in tear samples were evaluated as well. Results: 31 subjects completed the FU. Between BL and FU, mMGS decreased from 30.4 (8.5) to 9.3 (9.5) (− 69.3%, 95% CI: − 55.6% to − 82.9%, p< 0.0001); OSDI decreased from 63.6 (17.2) to 25.0 (20.6) (− 60.7%, 95% CI: − 47.8% to − 73.5%, p< 0.0001); NIBUT did not change (p=0.92). An adjusted model with a historical control was constructed to allow the comparison of these subjects with those treated similarly with IPL+MGX (but without RF) in a different study. This analysis identified that the change in mMGS was larger when RF was included (− 20.9 vs − 18.3, adjusted p-value (p_adjusted) < 0.05). The difference in OSDI change was not significant (− 38.1 vs − 25.5, p_adjusted = 0.196). Conclusion: Combination of multi-frequency RF and IPL+MGX improves signs and symptoms of MGD. In comparison to a historical control, improvements were generally larger. A randomized controlled study comparing the combination of RF and IPL+MGX with IPL+MGX alone is required to further elaborate the relative contribution of RF.
- Open Access
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2277-2285
Visual Outcomes, Quality of Vision, Patient Satisfaction and Spectacle Independence After Bilateral Implantation of the Synergy™ Intraocular Lens
Purpose: To evaluate vision, visual quality, patient satisfaction and spectacle independence after bilateral implantation of the TECNIS Synergy™ intraocular lens. Setting: Two clinical practices in the USA. Design: Ambispective unmasked non-randomized clinical trial. Methods: Patients with a history of uneventful bilateral femtosecond laser assisted cataract surgery with the study IOL implanted, targeted for emmetropia, at least 3 months prior to the study visit were enrolled. Monocular and binocular visual acuity (VA) were measured at distance, intermediate and near, along with binocular mesopic VA. Low contrast binocular VA and reading speed in mesopic and photopic conditions were also measured. Patient satisfaction, spectacle independence, visual symptoms, and functional vision questionnaires were completed. Results: Results from 52 subjects were available for analysis. Mean binocular unaided visual acuity was ~0.1 logMAR (20/20) from distance to 33 cm, with 81% of subjects having 0.2 logMAR (20/25) vision or better at all test distances and 92% reporting never needing glasses at any distance. Average reading speed at 40 cm was only 10 words/minute slower in dim light (p = 0.03). Mesopic and low contrast acuity appeared good. Halos were the most frequent and bothersome visual disturbances, with the greatest effect on driving at night. Eighty-eight percent of subjects reported being “completely” or “mostly” satisfied with their overall unaided vision. Conclusion: This hybrid technology IOL provided a range of binocular visual acuity from distance to 33 cm and good functional vision, even in dim light. Patients should be advised of the likelihood of visual disturbances, particularly halos.
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2277-2285
Open AccessVisual Outcomes, Quality of Vision, Patient Satisfaction and Spectacle Independence After Bilateral Implantation of the Synergy™ Intraocular Lens
Purpose: To evaluate vision, visual quality, patient satisfaction and spectacle independence after bilateral implantation of the TECNIS Synergy™ intraocular lens. Setting: Two clinical practices in the USA. Design: Ambispective unmasked non-randomized clinical trial. Methods: Patients with a history of uneventful bilateral femtosecond laser assisted cataract surgery with the study IOL implanted, targeted for emmetropia, at least 3 months prior to the study visit were enrolled. Monocular and binocular visual acuity (VA) were measured at distance, intermediate and near, along with binocular mesopic VA. Low contrast binocular VA and reading speed in mesopic and photopic conditions were also measured. Patient satisfaction, spectacle independence, visual symptoms, and functional vision questionnaires were completed. Results: Results from 52 subjects were available for analysis. Mean binocular unaided visual acuity was ~0.1 logMAR (20/20) from distance to 33 cm, with 81% of subjects having 0.2 logMAR (20/25) vision or better at all test distances and 92% reporting never needing glasses at any distance. Average reading speed at 40 cm was only 10 words/minute slower in dim light (p = 0.03). Mesopic and low contrast acuity appeared good. Halos were the most frequent and bothersome visual disturbances, with the greatest effect on driving at night. Eighty-eight percent of subjects reported being “completely” or “mostly” satisfied with their overall unaided vision. Conclusion: This hybrid technology IOL provided a range of binocular visual acuity from distance to 33 cm and good functional vision, even in dim light. Patients should be advised of the likelihood of visual disturbances, particularly halos.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 686-690
Visual outcomes, satisfaction, and spectacle independence with a nondiffractive extended vision intraocular lens targeted for slight monovision
Purpose: To evaluate vision, satisfaction, and spectacle independence of the AcrySof® IQ Vivity® intraocular lens when the non-dominant eye is targeted for slight myopia. Setting: One clinical practice in the USA Design: Prospective unmasked non-randomized clinical trial. Methods: Subjects presenting for cataract surgery interested in reducing their dependence on spectacles were enrolled, with the dominant eye targeted for emmetropia and the non-dominant eye targeted for slight monovision (-0.50D). Visual disturbances, satisfaction and spectacle independence were evaluated. Visual acuity (VA) was tested at distance (4 m), intermediate (66 cm) and near (40 cm) 3 months after surgery when uncorrected, with both eyes corrected to emmetropia and with one eye adjusted for monovision. Two binocular defocus curves were also collected under the latter two conditions. Results: Data from 31 subjects were analyzed. The mean refractive spherical equivalent was 0.45 D more myopic in the non-dominant eye, resulting in worse uncorrected VA at distance but better uncorrected VA at near. The binocular defocus curve with monovision showed significantly better VA from -2.0 to -3.0 D and subjects reported less need for glasses (and better vision) at near than reported with binocular emmetropia. Glare, blurred vision, and starbursts were the most reported visual disturbances. While not correlated to the difference in refraction, glare and blurred vision were significantly correlated to overall satisfaction. Conclusions: Implanting this IOL with a target of slight myopia in the non-dominant eye appears to be a viable way to improve near vision, though with an increased potential for visual disturbances.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 686-690
Visual outcomes, satisfaction, and spectacle independence with a nondiffractive extended vision intraocular lens targeted for slight monovision
Purpose: To evaluate vision, satisfaction, and spectacle independence of the AcrySof® IQ Vivity® intraocular lens when the non-dominant eye is targeted for slight myopia. Setting: One clinical practice in the USA Design: Prospective unmasked non-randomized clinical trial. Methods: Subjects presenting for cataract surgery interested in reducing their dependence on spectacles were enrolled, with the dominant eye targeted for emmetropia and the non-dominant eye targeted for slight monovision (-0.50D). Visual disturbances, satisfaction and spectacle independence were evaluated. Visual acuity (VA) was tested at distance (4 m), intermediate (66 cm) and near (40 cm) 3 months after surgery when uncorrected, with both eyes corrected to emmetropia and with one eye adjusted for monovision. Two binocular defocus curves were also collected under the latter two conditions. Results: Data from 31 subjects were analyzed. The mean refractive spherical equivalent was 0.45 D more myopic in the non-dominant eye, resulting in worse uncorrected VA at distance but better uncorrected VA at near. The binocular defocus curve with monovision showed significantly better VA from -2.0 to -3.0 D and subjects reported less need for glasses (and better vision) at near than reported with binocular emmetropia. Glare, blurred vision, and starbursts were the most reported visual disturbances. While not correlated to the difference in refraction, glare and blurred vision were significantly correlated to overall satisfaction. Conclusions: Implanting this IOL with a target of slight myopia in the non-dominant eye appears to be a viable way to improve near vision, though with an increased potential for visual disturbances.