Associated Eyecare
Type
HealthcareLocations
Stillwater, United StatesLatest Publications
- Open Access
- 1 November 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-13
Evidence and Guidance for Contact Lenses in the Management of Pediatric Aphakia: A Narrative Review
Background: Effective, early optical rehabilitation is of critical importance to long-term visual and developmental outcomes in children with aphakia. While aphakia in adults is primarily managed through intraocular lens (IOL) implantation, the use of IOLs in children is not approved by the US Food and Drug Administration, and IOL implantation is particularly controversial in infants. Therefore, contact lenses (CLs) have an important role to play in the management of pediatric aphakia. In light of evolving regional lens availability, this narrative review aims to provide practical guidance, clinical pearls, and regional insights on CL choice and to discuss unmet needs in the management of pediatric aphakia, drawing on both contemporary evidence and expert testimony. Methods: A literature search was conducted in PubMed from 1 January 2006 to 1 January 2026 to evaluate CL use in children with aphakia, including soft (silicone elastomer and silicone hydrogel), rigid gas-permeable (RGP), and scleral lenses. Search results were reviewed for relevance, prioritizing contemporary evidence published from 2018 to 2026. Results: Silicone elastomer, silicone hydrogel, RGP, and scleral lenses may provide effective optical rehabilitation in children with aphakia. Silicone elastomer lenses have underpinned care due to high oxygen permeability and positive comfort, handling, and wear characteristics. Emerging silicone hydrogel designs provide effective alternatives with comparable visual outcomes, favorable tolerability, and an extended range of pediatric-specific geometries and wear characteristics. RGP lenses provide acceptable visual outcomes and safety characteristics but are limited by tolerability concerns. Evidence for scleral lenses remains limited but supports their use in longer-term management of pediatric aphakia. Conclusion: Individualized CL selection is essential to optimize visual outcomes in children with aphakia, integrating patient and caregiver needs with the strengths and limitations of available options. Further comparative evidence, practical guidance, caregiver support, and innovation in lens design are needed to improve outcomes in pediatric aphakia.
- 1 November 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-13
Open AccessEvidence and Guidance for Contact Lenses in the Management of Pediatric Aphakia: A Narrative Review
Background: Effective, early optical rehabilitation is of critical importance to long-term visual and developmental outcomes in children with aphakia. While aphakia in adults is primarily managed through intraocular lens (IOL) implantation, the use of IOLs in children is not approved by the US Food and Drug Administration, and IOL implantation is particularly controversial in infants. Therefore, contact lenses (CLs) have an important role to play in the management of pediatric aphakia. In light of evolving regional lens availability, this narrative review aims to provide practical guidance, clinical pearls, and regional insights on CL choice and to discuss unmet needs in the management of pediatric aphakia, drawing on both contemporary evidence and expert testimony. Methods: A literature search was conducted in PubMed from 1 January 2006 to 1 January 2026 to evaluate CL use in children with aphakia, including soft (silicone elastomer and silicone hydrogel), rigid gas-permeable (RGP), and scleral lenses. Search results were reviewed for relevance, prioritizing contemporary evidence published from 2018 to 2026. Results: Silicone elastomer, silicone hydrogel, RGP, and scleral lenses may provide effective optical rehabilitation in children with aphakia. Silicone elastomer lenses have underpinned care due to high oxygen permeability and positive comfort, handling, and wear characteristics. Emerging silicone hydrogel designs provide effective alternatives with comparable visual outcomes, favorable tolerability, and an extended range of pediatric-specific geometries and wear characteristics. RGP lenses provide acceptable visual outcomes and safety characteristics but are limited by tolerability concerns. Evidence for scleral lenses remains limited but supports their use in longer-term management of pediatric aphakia. Conclusion: Individualized CL selection is essential to optimize visual outcomes in children with aphakia, integrating patient and caregiver needs with the strengths and limitations of available options. Further comparative evidence, practical guidance, caregiver support, and innovation in lens design are needed to improve outcomes in pediatric aphakia.
- Open Access
- 22 February 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (4) , 693-704
Early Effects of Perfluorohexyloctane Ophthalmic Solution on Patient-Reported Outcomes in Dry Eye Disease: A Prospective, Open-Label, Multicenter Study
Introduction Perfluorohexyloctane ophthalmic solution (PFHO) is indicated for the treatment of signs and symptoms of dry eye disease (DED) and targets excessive tear evaporation. This study evaluated patient-reported outcomes early in treatment with PFHO. Methods This prospective, multicenter, open-label, phase 4 study enrolled adults with a history of DED for ≥ 6 months. PFHO was instilled in both eyes four times daily for 14 days. Patients completed early outcome surveys during four clinic visits (day 1 [pretreatment; 5 and 60 min post-PFHO instillation] and days 3, 7, and 14). Symptom severity, symptom frequency, and treatment satisfaction were rated on visual analog scales (range 0–100). The primary endpoint was mean change from baseline in overall DED symptom severity at day 7. Secondary endpoints included change in severity of individual DED symptoms (eye dryness, blurred vision, eye irritation, light sensitivity, eye tiredness, burning/stinging, eye itching, eye pain); change in frequency (measured as percentage of time experienced) of the most bothersome symptom, awareness of dry eye symptoms, and fluctuation in quality of vision; and treatment satisfaction. Results Ninety-nine patients enrolled (85.9% female; age range 35–81 years). The primary endpoint was met: mean (SD) overall symptom severity decreased significantly from 72.1 (17.0) at baseline to 27.8 (22.3) at day 7 (mean change, − 44.5; P < 0.0001). Mean (SD) percentage of time experiencing the most bothersome symptom decreased from 77.9% at baseline to 34.7% at day 14 (P < 0.0001). Significant reductions in severity and frequency also were observed for all symptoms at all postbaseline assessments (P < 0.0001). Median ratings of treatment satisfaction were 83.0 at day 3, 86.0 at day 7, and 90.0 at day 14. Conclusion Early in the course of treatment with PFHO, patients with DED experienced significant reductions in dry eye symptom frequency and severity. Treatment satisfaction with PFHO was high. Trial Registration ClinicalTrials.gov identifier NCT06309953.
- 22 February 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (4) , 693-704
Open AccessEarly Effects of Perfluorohexyloctane Ophthalmic Solution on Patient-Reported Outcomes in Dry Eye Disease: A Prospective, Open-Label, Multicenter Study
Introduction Perfluorohexyloctane ophthalmic solution (PFHO) is indicated for the treatment of signs and symptoms of dry eye disease (DED) and targets excessive tear evaporation. This study evaluated patient-reported outcomes early in treatment with PFHO. Methods This prospective, multicenter, open-label, phase 4 study enrolled adults with a history of DED for ≥ 6 months. PFHO was instilled in both eyes four times daily for 14 days. Patients completed early outcome surveys during four clinic visits (day 1 [pretreatment; 5 and 60 min post-PFHO instillation] and days 3, 7, and 14). Symptom severity, symptom frequency, and treatment satisfaction were rated on visual analog scales (range 0–100). The primary endpoint was mean change from baseline in overall DED symptom severity at day 7. Secondary endpoints included change in severity of individual DED symptoms (eye dryness, blurred vision, eye irritation, light sensitivity, eye tiredness, burning/stinging, eye itching, eye pain); change in frequency (measured as percentage of time experienced) of the most bothersome symptom, awareness of dry eye symptoms, and fluctuation in quality of vision; and treatment satisfaction. Results Ninety-nine patients enrolled (85.9% female; age range 35–81 years). The primary endpoint was met: mean (SD) overall symptom severity decreased significantly from 72.1 (17.0) at baseline to 27.8 (22.3) at day 7 (mean change, − 44.5; P < 0.0001). Mean (SD) percentage of time experiencing the most bothersome symptom decreased from 77.9% at baseline to 34.7% at day 14 (P < 0.0001). Significant reductions in severity and frequency also were observed for all symptoms at all postbaseline assessments (P < 0.0001). Median ratings of treatment satisfaction were 83.0 at day 3, 86.0 at day 7, and 90.0 at day 14. Conclusion Early in the course of treatment with PFHO, patients with DED experienced significant reductions in dry eye symptom frequency and severity. Treatment satisfaction with PFHO was high. Trial Registration ClinicalTrials.gov identifier NCT06309953.
- Open Access
- 1 August 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2405-2410
Evaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis
Purpose: To evaluate the rotational stability of a toric extended depth of focus (EDOF) intraocular lens (IOL), using either slit lamp evaluation or image-processing software. Setting: Three clinical practices in the USA. Design: Prospective unmasked randomized clinical trial. Methods: Subjects presenting for routine cataract surgery that were interested in improved near vision received toric EDOF lenses (TECNIS Symfony® Toric) in both eyes. The measures of interest in the current analysis were the change in orientation of the IOL between 1 day, 1 month and 3 months postoperative. Orientation was measured at the microscope on the day of surgery, and with the slit lamp at all other visits. Day 1, 1-month and 3-month images of the lens orientation were captured with a slit lamp camera. Differences in orientation were recorded and analyzed. Results: A total of 150 eyes had IOL orientation data available. Image analysis showed mean absolute lens orientation changes from 1 day to 1 month and 3 months of less than 2 degrees. The percentage of lenses exhibiting rotation of ≤ 5 degrees between any measured time points was 97% or higher. Results were similar, but significantly more variable, when IOL orientation was measured at the slit lamp. Conclusion: The toric EDOF lens evaluated here demonstrated rotational stability that exceeded the prior ANSI standard. The best method to determine IOL orientation changes was through image analysis.
- 1 August 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2405-2410
Open AccessEvaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis
Purpose: To evaluate the rotational stability of a toric extended depth of focus (EDOF) intraocular lens (IOL), using either slit lamp evaluation or image-processing software. Setting: Three clinical practices in the USA. Design: Prospective unmasked randomized clinical trial. Methods: Subjects presenting for routine cataract surgery that were interested in improved near vision received toric EDOF lenses (TECNIS Symfony® Toric) in both eyes. The measures of interest in the current analysis were the change in orientation of the IOL between 1 day, 1 month and 3 months postoperative. Orientation was measured at the microscope on the day of surgery, and with the slit lamp at all other visits. Day 1, 1-month and 3-month images of the lens orientation were captured with a slit lamp camera. Differences in orientation were recorded and analyzed. Results: A total of 150 eyes had IOL orientation data available. Image analysis showed mean absolute lens orientation changes from 1 day to 1 month and 3 months of less than 2 degrees. The percentage of lenses exhibiting rotation of ≤ 5 degrees between any measured time points was 97% or higher. Results were similar, but significantly more variable, when IOL orientation was measured at the slit lamp. Conclusion: The toric EDOF lens evaluated here demonstrated rotational stability that exceeded the prior ANSI standard. The best method to determine IOL orientation changes was through image analysis.
- Open Access
- 1 June 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1791-1798
Defocus Curve and Patient Satisfaction with a New Extended Depth of Focus Toric Intraocular Lens Targeted for Binocular Emmetropia or Slight Myopia in the Non-Dominant Eye
Purpose: To evaluate the defocus curve and patient satisfaction after implantation of an extended depth of focus (EDOF) toric IOL when both eyes were targeted for emmetropia and when the non-dominant eye was targeted for mini monovision (− 0.50D). Methods: A prospective unmasked randomized clinical trial in three clinical practices in the USA. Subjects presenting for routine cataract surgery were assigned to one of two groups, both receiving bilateral toric EDOF lenses. One group had the non-dominant eye targeted for slight myopia (− 0.50D). Measures of interest were the postoperative defocus curve and reported patient satisfaction and visual disturbances. Results: Questionnaire and defocus curve data were available from 37 subjects in the Emmetropia group, while the mini monovision group included questionnaire data from 39 subjects and valid defocus curve data from 14 subjects. Mini monovision subjects had significantly better VA (a half line to a line better, p < 0.05), from a defocus of − 1.50 D to − 3.00 D. Reported spectacle wear and satisfaction were not significantly different between groups at any distance, but more patients in the mini monovision group reported the ability to function comfortably without glasses at near and overall (near p = 0.02, overall p < 0.01). Halos and starbursts were the two phenomena reported most often for both groups, with reported starbursts slightly more common in the mini monovision group. Conclusions: A slightly myopic correction in the non-dominant eye improved binocular near vision by 0.5 to 1.0 lines based on defocus curve data. Patients reported better functional vision, but with a slight increase in reported starbursts in the mini monovision group.
- 1 June 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1791-1798
Open AccessDefocus Curve and Patient Satisfaction with a New Extended Depth of Focus Toric Intraocular Lens Targeted for Binocular Emmetropia or Slight Myopia in the Non-Dominant Eye
Purpose: To evaluate the defocus curve and patient satisfaction after implantation of an extended depth of focus (EDOF) toric IOL when both eyes were targeted for emmetropia and when the non-dominant eye was targeted for mini monovision (− 0.50D). Methods: A prospective unmasked randomized clinical trial in three clinical practices in the USA. Subjects presenting for routine cataract surgery were assigned to one of two groups, both receiving bilateral toric EDOF lenses. One group had the non-dominant eye targeted for slight myopia (− 0.50D). Measures of interest were the postoperative defocus curve and reported patient satisfaction and visual disturbances. Results: Questionnaire and defocus curve data were available from 37 subjects in the Emmetropia group, while the mini monovision group included questionnaire data from 39 subjects and valid defocus curve data from 14 subjects. Mini monovision subjects had significantly better VA (a half line to a line better, p < 0.05), from a defocus of − 1.50 D to − 3.00 D. Reported spectacle wear and satisfaction were not significantly different between groups at any distance, but more patients in the mini monovision group reported the ability to function comfortably without glasses at near and overall (near p = 0.02, overall p < 0.01). Halos and starbursts were the two phenomena reported most often for both groups, with reported starbursts slightly more common in the mini monovision group. Conclusions: A slightly myopic correction in the non-dominant eye improved binocular near vision by 0.5 to 1.0 lines based on defocus curve data. Patients reported better functional vision, but with a slight increase in reported starbursts in the mini monovision group.
- Open Access
- 1 December 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2591-2598
Patient-Reported Outcomes/Satisfaction and Spectacle Independence with Blended or Bilateral Multifocal Intraocular Lenses in Cataract Surgery
Purpose: To compare patient-reported outcomes (PROs) and satisfaction results after multifocal intraocular lens (IOL) implantation in three groups: two receiving bilateral implantation of the same IOL and another undergoing blended vision with two different multifocal IOLs. Patients and methods: A questionnaire was administered to patients who had undergone uncomplicated cataract surgery and 2 months of follow-up: the first group underwent bilateral implantation with Alcon’s AcrySof ReSTOR 3.0 lens (“3.0/3.0,” n=78); the second group underwent implantation with the ReSTOR ActiveFocus 2.5 or the ReSTOR ActiveFocus 2.5 toric lens (“2.5 mini-monovision,” n=102); and the third group underwent implantation with the ReSTOR 2.5 lens in the dominant eye and the ReSTOR 3.0 lens in the non-dominant eye (“2.5/3.0,” n=89). Results: Overall PROs and satisfaction was similar among the groups. Refractive outcomes and accuracy were similar among the groups, but the 2.5 mini-monovision group reported better intermediate vision. Refractive outcome differences were not meaningful among the groups and were not a differentiating factor in PROs. Substantially fewer patients in the 2.5 mini-monovision group noticed glare and halo compared with the 3.0/3.0 group (PConclusion: The 2.5 mini-monovision results in a higher percentage of patients being satisfied with intermediate vision than bilateral ReSTOR 3.0 or blended vision with ReSTOR 2.5/3.0 implants, but overall PRO differences were not statistically significant.
- 1 December 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2591-2598
Open AccessPatient-Reported Outcomes/Satisfaction and Spectacle Independence with Blended or Bilateral Multifocal Intraocular Lenses in Cataract Surgery
Purpose: To compare patient-reported outcomes (PROs) and satisfaction results after multifocal intraocular lens (IOL) implantation in three groups: two receiving bilateral implantation of the same IOL and another undergoing blended vision with two different multifocal IOLs. Patients and methods: A questionnaire was administered to patients who had undergone uncomplicated cataract surgery and 2 months of follow-up: the first group underwent bilateral implantation with Alcon’s AcrySof ReSTOR 3.0 lens (“3.0/3.0,” n=78); the second group underwent implantation with the ReSTOR ActiveFocus 2.5 or the ReSTOR ActiveFocus 2.5 toric lens (“2.5 mini-monovision,” n=102); and the third group underwent implantation with the ReSTOR 2.5 lens in the dominant eye and the ReSTOR 3.0 lens in the non-dominant eye (“2.5/3.0,” n=89). Results: Overall PROs and satisfaction was similar among the groups. Refractive outcomes and accuracy were similar among the groups, but the 2.5 mini-monovision group reported better intermediate vision. Refractive outcome differences were not meaningful among the groups and were not a differentiating factor in PROs. Substantially fewer patients in the 2.5 mini-monovision group noticed glare and halo compared with the 3.0/3.0 group (PConclusion: The 2.5 mini-monovision results in a higher percentage of patients being satisfied with intermediate vision than bilateral ReSTOR 3.0 or blended vision with ReSTOR 2.5/3.0 implants, but overall PRO differences were not statistically significant.
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (10) , 1398-1403
Extended depth-of-focus toric intraocular lens targeted for binocular emmetropia or slight myopia in the nondominant eye: Visual and refractive clinical outcomes
To compare the visual and refractive outcomes with a diffractive toric extended depth-of-focus (EDOF) intraocular lens (IOL) when both eyes are targeted for emmetropia and the nondominant eye is targeted for slight myopia. Three clinical practices, United States. Prospective case series. Patients having routine cataract surgery with bilateral Tecnis Symfony toric EDOF IOL implantation were assigned to 1 of 2 groups. In 1 group, the nondominant eye was targeted for -0.50 diopter (D) (mini-monovision). Assessments included uncorrected monocular and binocular visual acuities (logarithm of the minimum angle of resolution) at distance (4 m), intermediate (66 cm), and near (40 cm) and the postoperative residual refractive error. Forty patients were enrolled in each group, with 1 dropout. The mean postoperative residual refractive astigmatism was 0.25 D in both groups, with no statistically significant difference. The mean residual refractive astigmatism was 0.50 D or lower in 92% of eyes (72/78) in the mini-monovision group and 95% of eyes (74/78) in the emmetropia group 3 months postoperatively. The mini-monovision group had slightly worse uncorrected visual acuity at 4 m than the emmetropia group (0.16 versus 0.09; P = .002) but better uncorrected acuity at 40 cm (0.25 versus 0.34; P < .001). Binocular uncorrected acuity was not statistically significantly different between groups at 4 m (-0.03 versus -0.01; P = .33) or 66 cm (0.06 versus 0.04; P = .34) but was statistically significant at 40 cm (0.25 versus 0.19; P = .03). The EDOF toric IOL provided functional distance, intermediate, and near vision. A slight monovision approach appears to improve near visual acuity.
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (10) , 1398-1403
Extended depth-of-focus toric intraocular lens targeted for binocular emmetropia or slight myopia in the nondominant eye: Visual and refractive clinical outcomes
To compare the visual and refractive outcomes with a diffractive toric extended depth-of-focus (EDOF) intraocular lens (IOL) when both eyes are targeted for emmetropia and the nondominant eye is targeted for slight myopia. Three clinical practices, United States. Prospective case series. Patients having routine cataract surgery with bilateral Tecnis Symfony toric EDOF IOL implantation were assigned to 1 of 2 groups. In 1 group, the nondominant eye was targeted for -0.50 diopter (D) (mini-monovision). Assessments included uncorrected monocular and binocular visual acuities (logarithm of the minimum angle of resolution) at distance (4 m), intermediate (66 cm), and near (40 cm) and the postoperative residual refractive error. Forty patients were enrolled in each group, with 1 dropout. The mean postoperative residual refractive astigmatism was 0.25 D in both groups, with no statistically significant difference. The mean residual refractive astigmatism was 0.50 D or lower in 92% of eyes (72/78) in the mini-monovision group and 95% of eyes (74/78) in the emmetropia group 3 months postoperatively. The mini-monovision group had slightly worse uncorrected visual acuity at 4 m than the emmetropia group (0.16 versus 0.09; P = .002) but better uncorrected acuity at 40 cm (0.25 versus 0.34; P < .001). Binocular uncorrected acuity was not statistically significantly different between groups at 4 m (-0.03 versus -0.01; P = .33) or 66 cm (0.06 versus 0.04; P = .34) but was statistically significant at 40 cm (0.25 versus 0.19; P = .03). The EDOF toric IOL provided functional distance, intermediate, and near vision. A slight monovision approach appears to improve near visual acuity.
- Open Access
- 25 September 2019
- Published by Springer Nature in Cureus
- Vol. 11 (9) , e5760
Optical Coherence Tomography Angiography Findings in a Case of Cosmetic Laser Induced Retinal Injury
We report the first known case of iris and retinal injury using optical coherence tomography angiography (OCTA) images following cosmetic laser injury. A 23-year-old female developed left iris and retinal injury post inadvertent firing of a 755 nm Alexandrite cosmetic laser. The patient had no significant past medical history and the injury resulted from inappropriate eye protection during laser use. Injury from the laser caused damage to the retinal pigment epithelium (RPE), iris pigment epithelium (IPE), and ciliary body epithelium (CPE). The OCTA imaging modality detected the vascular injury caused by the Alexandrite 755 nm laser to the choroid and RPE with subsequent images visualizing the healing response in the months postinjury.
- 25 September 2019
- Published by Springer Nature in Cureus
- Vol. 11 (9) , e5760
Open AccessOptical Coherence Tomography Angiography Findings in a Case of Cosmetic Laser Induced Retinal Injury
We report the first known case of iris and retinal injury using optical coherence tomography angiography (OCTA) images following cosmetic laser injury. A 23-year-old female developed left iris and retinal injury post inadvertent firing of a 755 nm Alexandrite cosmetic laser. The patient had no significant past medical history and the injury resulted from inappropriate eye protection during laser use. Injury from the laser caused damage to the retinal pigment epithelium (RPE), iris pigment epithelium (IPE), and ciliary body epithelium (CPE). The OCTA imaging modality detected the vascular injury caused by the Alexandrite 755 nm laser to the choroid and RPE with subsequent images visualizing the healing response in the months postinjury.
- 1 February 2019
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 143 (2) , e20181182
Retinal Findings in Young Children With Increased Intracranial Pressure From Nontraumatic Causes
OBJECTIVES: Increased intracranial pressure (ICP) has been suggested in legal settings as an alternative cause of retinal hemorrhages (RHs) in young children who may have sustained abusive head trauma. We assessed the prevalence and characteristics of RHs in children with increased ICP. METHODS: We conducted a prospective, multicenter study of children <4 years old with newly diagnosed increased ICP as determined by using direct measurement and/or clinical criteria. Infants who were premature, neonates, and suspected survivors of abusive head trauma were excluded on the basis of nonocular findings. Fundus examinations were performed; extent, number, and type of RH in each of 4 distinct retinal zones were recorded. RESULTS: Fifty-six children (27 boys) were studied (mean age 15.4 months; range 1–43 months). All of the children had elevated ICP that required intervention. One child had papilledema. No child (0%; 95% confidence interval: 0%–6.4%) or eye (0%; 95% confidence interval: 0%–3.3%) was found to have an RH. Causes of increased ICP included hydrocephalus, intraventricular hemorrhage, congenital malformations, malfunctioning shunts, and the presence of intracranial space-occupying lesions. CONCLUSIONS: Although acute increased ICP can present in children with a pattern of peripapillary superficial RHs in the presence of papilledema, our study supports the conclusion that RHs rarely occur in the absence of optic disc swelling and do not present beyond the peripapillary area in the entities we have studied.
- 1 February 2019
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 143 (2) , e20181182
Retinal Findings in Young Children With Increased Intracranial Pressure From Nontraumatic Causes
OBJECTIVES: Increased intracranial pressure (ICP) has been suggested in legal settings as an alternative cause of retinal hemorrhages (RHs) in young children who may have sustained abusive head trauma. We assessed the prevalence and characteristics of RHs in children with increased ICP. METHODS: We conducted a prospective, multicenter study of children <4 years old with newly diagnosed increased ICP as determined by using direct measurement and/or clinical criteria. Infants who were premature, neonates, and suspected survivors of abusive head trauma were excluded on the basis of nonocular findings. Fundus examinations were performed; extent, number, and type of RH in each of 4 distinct retinal zones were recorded. RESULTS: Fifty-six children (27 boys) were studied (mean age 15.4 months; range 1–43 months). All of the children had elevated ICP that required intervention. One child had papilledema. No child (0%; 95% confidence interval: 0%–6.4%) or eye (0%; 95% confidence interval: 0%–3.3%) was found to have an RH. Causes of increased ICP included hydrocephalus, intraventricular hemorrhage, congenital malformations, malfunctioning shunts, and the presence of intracranial space-occupying lesions. CONCLUSIONS: Although acute increased ICP can present in children with a pattern of peripapillary superficial RHs in the presence of papilledema, our study supports the conclusion that RHs rarely occur in the absence of optic disc swelling and do not present beyond the peripapillary area in the entities we have studied.
- Open Access
- 7 April 2017
- Published by Springer Nature in Eye
- Vol. 31 (8) , 1250-1252
Assessment of a three-generation pedigree with Fuchs endothelial corneal dystrophy with anticipation for expansion of the triplet repeat in the TCF4 gene
- 7 April 2017
- Published by Springer Nature in Eye
- Vol. 31 (8) , 1250-1252
Open AccessAssessment of a three-generation pedigree with Fuchs endothelial corneal dystrophy with anticipation for expansion of the triplet repeat in the TCF4 gene
- 22 July 2016
- Published by Taylor & Francis in Current Medical Research and Opinion
- Vol. 32 (10) , 1759-1765
Lifitegrast clinical efficacy for treatment of signs and symptoms of dry eye disease across three randomized controlled trials
Objective: Report efficacy findings from three clinical trials (one phase 2 and two phase 3 [OPUS-1, OPUS-2]) of lifitegrast ophthalmic solution 5.0% for treatment of dry eye disease (DED). Research design and methods: Three 84-day, randomized, double-masked, placebo-controlled trials. Adults (≥18 years) with DED were randomized (1:1) to lifitegrast 5.0% or matching placebo. Changes from baseline to day 84 in signs and symptoms of DED were analyzed. Main outcome measures: Phase 2, pre-specified endpoint: inferior corneal staining score (ICSS; 0–4); OPUS-1, coprimary endpoints: ICSS and visual-related function subscale (0–4 scale); OPUS-2, coprimary endpoints: ICSS and eye dryness score (EDS, VAS; 0–100). Results: Fifty-eight participants were randomized to lifitegrast 5.0% and 58 to placebo in the phase 2 trial; 293 to lifitegrast and 295 to placebo in OPUS-1; 358 to lifitegrast and 360 to placebo in OPUS-2. In participants with mild-to-moderate baseline DED symptomatology, lifitegrast improved ICSS versus placebo in the phase 2 study (treatment effect, 0.35; 95% CI, 0.05–0.65; p = 0.0209) and OPUS-1 (effect, 0.24; 95% CI, 0.10–0.38; p = 0.0007). Among more symptomatic participants (baseline EDS ≥40, recent artificial tear use), lifitegrast improved EDS versus placebo in a post hoc analysis of OPUS-1 (effect, 13.34; 95% CI, 2.35–24.33; nominal p = 0.0178) and in OPUS-2 (effect, 12.61; 95% CI, 8.51–16.70; p < 0.0001). Limitations: Trials were conducted over 12 weeks; efficacy beyond this period was not assessed. Conclusions: Across three trials, lifitegrast improved ICSS in participants with mild-to-moderate baseline symptomatology in two studies, and EDS in participants with moderate-to-severe baseline symptomatology in two studies. Based on the overall findings from these trials, lifitegrast shows promise as a new treatment option for signs and symptoms of DED.
- 22 July 2016
- Published by Taylor & Francis in Current Medical Research and Opinion
- Vol. 32 (10) , 1759-1765
Lifitegrast clinical efficacy for treatment of signs and symptoms of dry eye disease across three randomized controlled trials
Objective: Report efficacy findings from three clinical trials (one phase 2 and two phase 3 [OPUS-1, OPUS-2]) of lifitegrast ophthalmic solution 5.0% for treatment of dry eye disease (DED). Research design and methods: Three 84-day, randomized, double-masked, placebo-controlled trials. Adults (≥18 years) with DED were randomized (1:1) to lifitegrast 5.0% or matching placebo. Changes from baseline to day 84 in signs and symptoms of DED were analyzed. Main outcome measures: Phase 2, pre-specified endpoint: inferior corneal staining score (ICSS; 0–4); OPUS-1, coprimary endpoints: ICSS and visual-related function subscale (0–4 scale); OPUS-2, coprimary endpoints: ICSS and eye dryness score (EDS, VAS; 0–100). Results: Fifty-eight participants were randomized to lifitegrast 5.0% and 58 to placebo in the phase 2 trial; 293 to lifitegrast and 295 to placebo in OPUS-1; 358 to lifitegrast and 360 to placebo in OPUS-2. In participants with mild-to-moderate baseline DED symptomatology, lifitegrast improved ICSS versus placebo in the phase 2 study (treatment effect, 0.35; 95% CI, 0.05–0.65; p = 0.0209) and OPUS-1 (effect, 0.24; 95% CI, 0.10–0.38; p = 0.0007). Among more symptomatic participants (baseline EDS ≥40, recent artificial tear use), lifitegrast improved EDS versus placebo in a post hoc analysis of OPUS-1 (effect, 13.34; 95% CI, 2.35–24.33; nominal p = 0.0178) and in OPUS-2 (effect, 12.61; 95% CI, 8.51–16.70; p < 0.0001). Limitations: Trials were conducted over 12 weeks; efficacy beyond this period was not assessed. Conclusions: Across three trials, lifitegrast improved ICSS in participants with mild-to-moderate baseline symptomatology in two studies, and EDS in participants with moderate-to-severe baseline symptomatology in two studies. Based on the overall findings from these trials, lifitegrast shows promise as a new treatment option for signs and symptoms of DED.