Type
Company
Locations
Fort Collins, United States

Latest Publications

  • Open Access

    Facility-wide assessment of occupational exposure to dust, noise, and formaldehyde

    by Emilio Molina Rueda, Ellison Carter, Christian L’ORange, Meghan R. Cosgrove, Elizabeth A. Williams, Ashley A. Anderson, Marie J. Andales, Jessica Tryner, Marilee Long, Ander Wilson, et al.

    Exposure to particulate matter, hazardous gases, and noise among workers causes millions of deaths, injuries, and disabilities annually. These exposures are not measured frequently, and most workers are never monitored because resources for monitoring are limited globally. Even in high-income countries, just two or three samples per workplace inspection are collected on average. Considerably larger sample sizes are required to estimate measures of central tendency and upper percentiles of common exposure distributions. Therefore, interventions and epidemiological studies often rely on poor estimates of those parameters. The objective of this study was to demonstrate that a small team can cost-effectively measure all workers' exposures to multiple hazards within a facility (~100 workers) in a single day while minimizing participant burden and loss of productivity. We deployed novel, compact personal monitors-called AirPens-to measure exposures to total particulates, formaldehyde, and A-weighted noise among workers at a furniture manufacturing facility during one full work shift. AirPens were preloaded with sampling media and preprogrammed to minimize field deployment time. On-board sensor data were used to identify sampling anomalies, confirm that AirPens were worn, and validate sampling results. Valid samples were then used to estimate exposure distribution parameters. A team of five people deployed 83 AirPens at the facility. After quality assurance screening, 67 PM, 67 noise, and 22 formaldehyde samples remained valid (or 72, 67, and 31, respectively if samples below the limit of detection are counted as valid). PM and noise exposure distribution parameters (e.g., arithmetic and geometric mean, 95th percentile) were estimated with high certainty. Uncertainty (i.e., confidence intervals) grew several fold when smaller sample sizes were analyzed. Use of streamlined multi-hazard monitoring technology enables dramatically higher sample throughput for workplace exposure assessment. This approach reduces the uncertainty of workplace risk assessment and facilitates more in-depth analyses of personal exposure. Comprehensive monitoring of personal exposure to air pollution is lacking due to technological and logistical limitations inherent to established monitoring methods. This lack of monitoring limits occupational health practice and epidemiologic research, which rely on sufficient sample sizes to support expert judgments or statistical inferences. This work demonstrates a new wearable sampler for particle, gas, and noise hazards, designed to overcome typical barriers to personal exposure assessment (e.g., cost, time, participant burden). Results show that this new sampling approach can produce measurements of similar quality, but on a much larger scale, compared to established technology.

  • Open Access

    Characterizing household air pollutant concentrations associated with an electrification program in the rural San Joaquin Valley

    by Michael A Johnson, Katherine A Kearns, Jesus Rivera, Sydney Jones, Jessica Tryner, Heather Miller, Ahana Ghosh, Maria Fe Aragon, Misbath Daouda, Ajay Pillarisetti, et al.

    Indoor nitrogen dioxide (NO2) and fine particulate matter (PM2.5) pollution is a concern in U.S. households, particularly those that cook using gas or propane stoves. These exposures are linked to a variety of adverse health outcomes, including asthma morbidity, that disproportionately affect low-income households. We conducted a cross-sectional study of 138 homes in four low-income rural communities in California’s San Joaquin Valley, comparing air pollutant concentrations in households that participated in a state electrification program against those using propane or natural gas for cooking. In each home, pollutants were monitored for approximately one month using Personal Air Monitors (PAMs) and for 48 hours using reference-grade instruments. Median 48-h average indoor NO2 concentrations were 63% lower in electric stove homes (electric: 6.0 ppb, gas: 16.0 ppb, p < 0.001). No electrified homes had 48-h indoor NO2 concentrations exceeding the California annual guideline of 30 ppb, while 17% of gas homes did. Additionally, no electric stove homes had 1-h rolling-average NO2 concentrations exceeding the 100 ppb level deemed unhealthy for sensitive groups by the US Environmental Protection Agency, whereas 41% of gas homes exceeded this threshold. PM2.5 concentrations were similar across groups, indicating that the cooking of food was the dominant contributor to PM2.5 mass concentrations, as opposed to particles generated from gas combustion. Our evaluation of monitoring durations showed that two to four days of NO2 data and one week of PM2.5 data provided reliable estimates of longer-term averages, suggesting that shorter campaigns may yield robust estimates of indoor air quality. These results (1) support the provision of electric cooking technologies as a strategy to address air quality-related health risks in rural, low-income communities and (2) provide new evidence from an understudied population that can inform future indoor air quality research and energy transition policies.

  • Open Access

    Personal and In-Home Exposures to Airborne Organophosphate Pesticides among Rural Residents of California’s Central Valley

    by Jessica Tryner, Grant Erlandson, Sherry WeMott, Luis Hernandez Ramirez, Mollie Phillips, Bonnie N. Young, Xiaoying Li, Gregory Dooley, Ander Wilson, John Volckens, et al.

    Residents of agricultural communities may experience higher exposures to pesticides due to their proximity to agricultural operations. We applied a novel measurement approach, using Ultrasonic Personal Air Samplers (UPAS), to quantify particulate matter and organophosphate pesticides in air in California’s Central Valley. We collected 124 personal, 126 in-home, and 32 outdoor air samples with 66 adults from 37 rural households in 2023 and 2024. We detected chlorpyrifos, acephate, malathion, diazinon, and naled in air samples. We detected gas-phase chlorpyrifos in 63% of personal samples and 86% of homeseven though use of chlorpyrifos has been banned in California (with few exceptions) since January 2021at 24 h average concentrations ranging up to 13 ng m–3 (personal) and 5.8 ng m–3 (in-home). We did not detect chlorpyrifos in outdoor air samples. Using linear mixed models, we found that higher indoor air temperatures and having more carpets/rugs were associated with higher indoor chlorpyrifos concentrations. The concentrations we measured were well below the California Department of Pesticide Regulation’s health screening level of 510 ng m–3 for chronic exposure to chlorpyrifos in air; nevertheless, our results suggest that persistent chlorpyrifos in home environments continues to contribute to nondietary exposure among California residents.

  • Open Access

    Particulate Matter Pollution in an Agricultural Setting: A Community-Engaged Research Study

    by Bonnie N. Young, Jessica Tryner, Luis Hernandez Ramirez, Sherry WeMott, Grant Erlandson, Xiaoying Li, Grace Kuiper, Daniel Alan Dean, Nayamin Martinez, Mollie Phillips, et al.

    California’s San Joaquin Valley experiences some of the worst particulate matter (PM) air pollution in the U.S., but PM2.5 and PM10 exposures in agricultural communities are understudied. We collaborated with rural residents living adjacent to large-scale agricultural production and processing activities to assess 24-h-average personal and indoor PM2.5 and PM10 concentrations during different seasons. We visited 35 participants from 18 households during December 2023, May 2024, and the September 2024 harvest season to collect PM samples and survey data. Mixed effects linear regression models (with random effects for participant or household) assessed associations between natural log-transformed PM concentrations and regional ambient PM, harvest season, as well as participant/household characteristics. Participants were mostly female (69%) and Hispanic/Latino(a) (100%). Median household distance to processing facility silos was 633 m. Median personal exposures to PM2.5 and PM10 were 11.1 and 45.5 µg m−3. Median indoor PM2.5 and PM10 levels were 12.9 and 24.3 µg m−3. Overall, 29% of personal and indoor PM2.5 samples and 33% of personal and indoor PM10 samples exceeded WHO 24-h air quality guidelines (15 µg m−3 PM2.5, 45 µg m−3 PM10). The factors most strongly associated with personal and indoor PM were household members working in agriculture and regional ambient PM measures.


  • Open Access

    A national crowdsourced network of low-cost fine particulate matter and aerosol optical depth monitors: results from the 2021 wildfire season in the United States

    by Eric A. Wendt, Bonne Ford, Michael Cheeseman, Zoey Rosen, Jeffrey R. Pierce, Shantanu H. Jathar, Christian L'ORange, Casey Quinn, Marilee Long, John Mehaffy, et al.

    Fine particulate matter (PM2.5) is a leading contributor to premature death, disease, and environmental degradation globally. Wildfire smoke is a primary source of air pollution in the United States. However, reference-grade ground monitors are cost prohibitive to deploy at the spatial scales needed to assess the variability of wildfire smoke. In many regions lacking adequate monitoring, health impact assessments and epidemiological studies on smoke may rely on satellite-based instruments, which estimate PM2.5 based on Aerosol Optical Depth (AOD). However, AOD measurements may not capture surface-level impacts; thus, measurements in under-monitored regions are necessary to interpret satellite observations. While low-cost PM2.5 sensors have been deployed at large scales, these sensors typically lack AOD measurement capability. In prior work, we designed the Aerosol Mass and Optical Depth (AMODv2) sampler, which can simultaneously measure PM2.5 (optical and gravimetric filter-based) and AOD. In this work, we distributed AMODv2s to volunteers at 31 locations in the contiguous United States, forming a nationwide network for the summer of 2021. A majority of our network was successful, with 86.6% of sampling periods resulting in a valid sample. We found our AOD sensors agreed closely with nearby (< 25 km) reference monitor measurements (taken < 180 seconds apart), with mean absolute error results of 0.03, 0.02, 0.02, and 0.03 at 440, 500, 675, and 870 nm, respectively. In a regional analysis of wildfire smoke, we observed elevated PM2.5 and AOD on smoky days at study sites in most regions, which led to similar PM2.5:AOD ratios regardless of smoke. However, at the California study sites, median PM2.5 remained similar on smoky days relative to non-smoky days, while AOD increased, implying that the smoke may have been lofted above the surface during the study period. At the California study sites, the median PM2.5:AOD ratio was 67.2 µg m-3 on non-smoky days, compared with 30.2 µg m-3 on smoky days. At study sites in other regions, the average ratio was 24.7 to 33.5 µg m-3 on non-smoky days and 20.3 to 29.4 µg m-3 on smoky days We show that paired PM2.5 and AOD measurements collected by a crowdsourced network can highlight anomalies in air quality during smoke events and provide insights into the relationship between satellite-based and ground-based air quality observations.


  • Open Access

    Development and Evaluation of a Paper-Based Microfluidic Device for Detection of Listeria monocytogenes on Food Contact and Non-Food Contact Surfaces

    by Codi Jo Broten, John B. Wydallis, Thomas H. Reilly, Bledar Bisha

    Listeria monocytogenes is the third most deadly foodborne pathogen in the United States. The bacterium is found in soil and water, contaminating raw food products and the processing environment, where it can persist for an extended period. Currently, testing of food contact and non-food contact surfaces is performed using an array of sampling devices and endpoint technologies, offering various levels of sensitivity, cost, user skill, and time to detection. Paper-based microfluidic devices (µPADs) are a rapid detection platform amenable to low-cost, user-friendly, and portable diagnostics. In this study, we developed and evaluated a µPAD platform specific for the colorimetric detection of the Listeria genus following recovery from food contact and non-food contact surfaces. For detection, four colorimetric substrates specific for the detection of β-glucosidase, two broths selective for the detection of Listeria spp., and a nonselective broth were evaluated to facilitate detection of Listeria spp. The limit of detection and time to detection were determined by using pure bacterial cultures. After 8 h enrichment, L. monocytogenes (102 Colony Forming Units (CFU)/coupon) was detected on every surface. After 18 h enrichment, L. monocytogenes (102 CFU/coupon) was detected on all surfaces with all swabbing devices. This study demonstrated the ability of the µPAD-based method to detect potentially stressed cells at low levels of environmental contamination.


  • Open Access

    Multinational prediction of household and personal exposure to fine particulate matter (PM2.5) in the PURE cohort study

    by Matthew Shupler, Perry Hystad, Aaron Birch, Yen Li Chu, Matthew Jeronimo, Daniel Miller-Lionberg, Paul Gustafson, Sumathy Rangarajan, Maha Mustaha, Laura Heenan, et al.


  • Method for analysis of environmental lead contamination in soils

    by Chloe A. Beardsley, Kai Z. Fuller, Thomas H. Reilly, Charles S. Henry

    A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb—well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg−1 or 4000 ppb)—and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.


  • Open Access

    Design and testing of a low-cost sensor and sampling platform for indoor air quality

    by Jessica Tryner, Mollie Phillips, Casey Quinn, Gabe Neymark, Ander Wilson, Shantanu H. Jathar, Ellison Carter, John Volckens


  • Open Access

    A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth – Part 3: Automation and design improvements

    by Eric A. Wendt, Casey Quinn, Christian L'ORange, Daniel D. Miller-Lionberg, Bonne Ford, Jeffrey R. Pierce, John Mehaffy, Michael Cheeseman, Shantanu H. Jathar, David H. Hagan, et al.

    Atmospheric particulate matter smaller than 2.5 µm in diameter (PM2.5) has a negative impact on public health, the environment, and Earth's climate. Consequently, a need exists for accurate, distributed measurements of surface-level PM2.5 concentrations at a global scale. Existing PM2.5 measurement infrastructure provides broad PM2.5 sampling coverage but does not adequately characterize community-level air pollution at high temporal resolution. This motivates the development of low-cost sensors which can be more practically deployed in spatial and temporal configurations currently lacking proper characterization. Wendt et al. (2019) described the development and validation of a first-generation device for low-cost measurement of AOD and PM2.5: the Aerosol Mass and Optical Depth (AMODv1) sampler. Ford et al. (2019) describe a citizen-science field deployment of the AMODv1 device. In this paper, we present an updated version of the AMOD, known as AMODv2, featuring design improvements and extended validation to address the limitations of the AMODv1 work. The AMODv2 measures AOD and PM2.5 at 20 min time intervals. The sampler includes a motorized Sun tracking system alongside a set of four optically filtered photodiodes for semicontinuous, multiwavelength (current version at 440, 500, 675, and 870 nm) AOD sampling. Also included are a Plantower PMS5003 sensor for time-resolved optical PM2.5 measurements and a pump/cyclone system for time-integrated gravimetric filter measurements of particle mass and composition. AMODv2 samples are configured using a smartphone application, and sample data are made available via data streaming to a companion website (https://csu-ceams.com/, last access: 16 July 2021). We present the results of a 9 d AOD validation campaign where AMODv2 units were co-located with an AERONET (Aerosol Robotics Network) instrument as the reference method at AOD levels ranging from 0.02 ± 0.01 to 1.59 ± 0.01. We observed close agreement between AMODv2s and the reference instrument with mean absolute errors of 0.04, 0.06, 0.03, and 0.03 AOD units at 440, 500, 675, and 870 nm, respectively. We derived empirical relationships relating the reference AOD level to AMODv2 instrument error and found that the mean absolute error in the AMODv2 deviated by less than 0.01 AOD units between clear days and elevated-AOD days and across all wavelengths. We identified bias from individual units, particularly due to calibration drift, as the primary source of error between AMODv2s and reference units. In a test of 15-month calibration stability performed on 16 AMOD units, we observed median changes to calibration constant values of −7.14 %, −9.64 %, −0.75 %, and −2.80 % at 440, 500, 675, and 870 nm, respectively. We propose annual recalibration to mitigate potential errors from calibration drift. We conducted a trial deployment to assess the reliability and mechanical robustness of AMODv2 units. We found that 75 % of attempted samples were successfully completed in rooftop laboratory testing. We identify several failure modes in the laboratory testing and describe design changes that we have since implemented to reduce failures. We demonstrate that the AMODv2 is an accurate, stable, and low-cost platform for air pollution measurement. We describe how the AMODv2 can be implemented in spatial citizen-science networks where reference-grade sensors are economically impractical and low-cost sensors lack accuracy and stability.