Abstract
A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb—well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg−1 or 4000 ppb)—and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.Keywords
Funding Information
- National Institute of Environmental Health Sciences (R44ES024041)
This publication has 49 references indexed in Scilit:
- ICP-OES assessment of heavy metal contamination in tropical marine sediments: A comparative study of two digestion techniquesMicrochemical Journal, 2013
- Land Application of Treated Sewage Sludge: Community Health and Environmental JusticeEnvironmental Health Perspectives, 2013
- CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational ApplicationsPLOS ONE, 2011
- The effect of acetate concentration, solution pH and conductivity on the anodic stripping voltammetry of lead and cadmium ions at in situ bismuth-plated carbon microelectrodesJournal of Electroanalytical Chemistry, 2011
- Highly selective in situ metal ion determination by hybrid electrochemical “adsorption–desorption” and colorimetric methodsAnalytica Chimica Acta, 2011
- Bismuth-modified electrodes for lead detectionTrAC Trends in Analytical Chemistry, 2010
- A rapid field procedure for screening trace elements in polluted soil using portable X-ray fluorescence (PXRF)Geoderma, 2010
- Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodesAnalytica Chimica Acta, 2007
- Determination of heavy metals (Cd, Cr, Cu, Fe, Ni, Pb, Zn) by ICP-OES and their speciation in Algerian Mediterranean Sea sediments after a five-stage sequential extraction procedureEnvironmental Monitoring and Assessment, 2007
- Assessment of Mehlich3 and Ammonium Bicarbonate‐DTPA Extraction for Simultaneous Measurement of Fifteen Elements in SoilsCommunications in Soil Science and Plant Analysis, 2003