Model 1b analytical performance specifications – report on the Prague 2025 workshop
Open Access
- 18 August 2026
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
Abstract
The main purpose of establishing APS is to ensure that test performance aligns with their specific clinical goals. Analytical performance specifications serve multiple functions: as acceptance criteria to verify that in vitro diagnostic medical devices (IVD MD) meet regulatory and quality standards before market release; for external quality assurance assessments; for quality control, monitoring reagent lot-to-lot variability, and allowing preanalytical variation assessments in labs; and for guiding purchasing decisions by healthcare providers, reimbursement agencies, and both public and private insurers. Over the years, various systems and projects have been established to evaluate the current state of the art (Model 3) of IVD MD through external quality assurance (EQA). Different national and international EQA providers often use distinct acceptance criteria tailored to their organisational goals and local healthcare settings. Model 2, which relies on biological variation data, has been effectively supported by the European Federation of Clinical Chemistry and Laboratory Medicine’s database and its interactive tools for calculating APS ( www.biologicalvariation.eu ). Nonetheless, debates continue about optimal APS setting methods and the most suitable models for different measurands and scenarios. To explore these issues further, workshops were held in Prague in 2023 and 2025. This report presents the expert presentations from the 2025 workshop, which exclusively focused on APS based on Model 1b.Keywords
This publication has 47 references indexed in Scilit:
- Fecal Immunochemical Test Positivity Thresholds: An International Survey of Population-Based Screening ProgramsDigestive Diseases and Sciences, 2024
- Verifying measurements on Siemens Atellica® instruments using clinically acceptable analytical performance specificationsScandinavian Journal of Clinical and Laboratory Investigation, 2023
- Clinical decision limits as criteria for setting analytical performance specifications for laboratory testsClinica Chimica Acta, 2023
- Troponin I after Cardiac Surgery and 30-Day MortalityNew England Journal of Medicine, 2022
- Downstream Consequences of Implementing High-Sensitivity Cardiac TroponinJACC, 2021
- Methods to assess the impact of test measurement uncertainty on downstream clinical outcomes: A case study of faecal calprotectin (FC) for the diagnosis of Inflammatory Bowel Disease (IBD)Clinica Chimica Acta, 2019
- The Role of Measurement Uncertainty in Health Technology Assessments (HTAs) of In Vitro TestsPharmacoEconomics, 2018
- Impact of analytical and biological variations on classification of diabetes using fasting plasma glucose, oral glucose tolerance test and HbA1cScientific Reports, 2017
- Consensus agreementScandinavian Journal of Clinical and Laboratory Investigation, 1999
- The influence of analytical bias on diagnostic misclassificationsClinica Chimica Acta, 1997