Silver discharge electrode for suppression of ozone generation in positive dc corona
Authors:
- A. MizunoAMA. Mizuno
- 24 October 2005
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (01972618) , 1828-1832
Abstract
The aim of this paper is to suppress the ozone production in dc corona discharges, and is to report the effect of material of the discharge electrode on the ozone production. In this study, corona discharges were generated in a coaxial wire-cylinder reactor stressed by positive or negative dc voltage. A set of high purity wires made of different metals, and has constant radii, was tested as discharge electrodes. The reactor was fed by either dry air or oxygen flowing with a constant rate at atmospheric conditions. In the positive dc corona discharge, the ozone production was affected by material of the discharge electrode, and silver was effective to suppress the ozone production in dry air up to about 1/10 compare with that using tungsten electrode.Keywords
This publication has 11 references indexed in Scilit:
- On the characteristics of the corona discharge in a wire-duct reactorJournal of Physics D: Applied Physics, 2000
- On assessment of ozone generation in dc coronasJournal of Physics D: Applied Physics, 2000
- Optimization of a Corona Wire-to-Cylinder Ozonizer Critical Comparison With Other Authors Results Part II: Air and N2+ O2MixturesOzone: Science & Engineering, 1998
- Ozone Generation by Indoor, Electrostatic Air CleanersAerosol Science and Technology, 1997
- Silent-discharge driven excimer UV sources and their applicationsApplied Surface Science, 1992
- Nonequilibrium volume plasma chemical processingIEEE Transactions on Plasma Science, 1991
- Technological parameters that influence the production of ozone in A .D. C. Corona discharfeOzone: Science & Engineering, 1986
- Ozone generation in oxygen by corona discharges in a point-to-plane gap subjected to a chopped DC positive voltageJournal of Physics D: Applied Physics, 1981
- Ozone Generation in Positive Corona Electrostatic PrecipitatorsIEEE Transactions on Industry and General Applications, 1969
- D.C. corona on smooth conductors in air. Steady-state analysis of the ionisation layerProceedings of the Institution of Electrical Engineers, 1969