Abstract
This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists’ efficiency in clinical practice.Keywords
Funding Information
- Siemens Healthineers
This publication has 25 references indexed in Scilit:
- Automated Stanford classification of aortic dissection using a 2-step hierarchical neural network at computed tomography angiographyEuropean Radiology, 2021
- Automated segmentation and quantification of the healthy and diseased aorta in CT angiographies using a dedicated deep learning approachEuropean Radiology, 2021
- Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-upEuropean Journal of Radiology, 2021
- Classification of Aortic Dissection and Rupture on Post-contrast CT Images Using a Convolutional Neural NetworkJournal of Digital Imaging, 2019
- Automated 3D segmentation and diameter measurement of the thoracic aorta on non-contrast enhanced CTEuropean Radiology, 2019
- A novel software tool for semi-automatic quantification of thoracic aorta dilatation on baseline and follow-up computed tomography angiographyThe International Journal of Cardiovascular Imaging, 2018
- Association of Mortality and Acute Aortic Events With Ascending Aortic AneurysmJAMA Network Open, 2018
- Under-reporting of cardiovascular findings on chest CTLa radiologia medica, 2015
- Proximal thoracic aortic diameter measurements at CT: repeatability and reproducibility according to measurement methodThe International Journal of Cardiovascular Imaging, 2012
- Measurements and detection of abdominal aortic aneurysm growth: Accuracy and reproducibility of a segmentation softwareEuropean Journal of Radiology, 2012