DPDaniel Pinos

Daniel Pinos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Pinos has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • Akos Varga-Szemes

    Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA

    5 shared publications
  • Tilman Emrich

    Department of Radiology and Radiological Science Medical University of South Carolina Charleston South Carolina USA

    5 shared publications
  • Uwe Joseph Schoepf

    Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC

    4 shared publications
  • Jens Ricke

    Department of Radiology, University Hospital, LMU Munich, Munich, Germany

    3 shared publications
  • Jim O' Doherty

    Centre for Translational MR Research (TMR), Yong Loo Lin School of Medicine, National University of Singapore, Singapore; R&D Collaborations, Siemens Medical Solutions, Malvern, PA, US; Diagnostic Imaging, School of Medicine, University College Dublin, Ireland

    3 shared publications
  • Emese Zsarnoczay

    Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Department of Radiology, Medical Imaging Centre, Semmelweis University, Budapest, Hungary

    2 shared publications

Latest Publications

  • Radiology: Cardiothoracic Imaging Highlights 2025

    by Daniel Pinos, Lucas de Pádua Gomes de Farias, Carlotta Onnis, Dominika Suchá, Joanna G. Escalon, Kate Hanneman, Suhny Abbara, Harold I. Litt, Gaurav S. Gulsin, Domenico Mastrodicasa

    Articles published in Radiology: Cardiothoracic Imaging in 2025 highlight advances in cardiothoracic imaging through technical innovation, quantitative biomarkers, and artificial intelligence applications that support improved diagnosis, risk stratification, and patient-centered management across cardiac, vascular, and thoracic disease.

  • Impact of Photon-counting CT–based Virtual Monoenergetic Imaging on Detecting Myocardial Late Iodine Enhancement Compared to Cardiac MRI

    by Chiara Gnasso, Milán Vecsey-Nagy, Muhammad Taha Hagar, U. Joseph Schoepf, Daniel Alfonso Pinos Sanchez, Emese Zsarnóczay, Dmitrij Kravchenko, Giuseppe Tremamunno, Robert J. Holtackers, Moritz C. Halfmann, et al.

    Photon-counting detector CT delayed enhancement with virtual monoenergetic reconstructions at 50 keV had the best diagnostic performance and agreement with MRI when compared with other kiloelectron volt levels in detecting myocardial focal fibrosis and scars and characterizing scar patterns.


  • Predicting mortality after transcatheter aortic valve replacement using AI-based fully automated left atrioventricular coupling index

    by Emese Zsarnoczay, Akos Varga-Szemes, U. Joseph Schoepf, Saikiran Rapaka, Daniel Pinos, Gilberto J. Aquino, Nicola Fink, Milan Vecsey-Nagy, Giuseppe Tremamunno, Dmitrij Kravchenko, et al.


  • Improved Detection of Small and Low-Density Plaques in Virtual Noncontrast Imaging–based Calcium Scoring at Photon-Counting Detector CT

    by Nicola Fink, Tilman Emrich, U. Joseph Schoepf, Emese Zsarnoczay, Jim O’dOherty, Moritz C. Halfmann, Joseph P. Griffith, Daniel Pinos, Pal Suranyi, Dhiraj Baruah, et al.

    Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


  • Open Access

    Artificial Intelligence Provides Accurate Quantification of Thoracic Aortic Enlargement and Dissection in Chest CT

    by Nicola Fink, Basel Yacoub, U. Joseph Schoepf, Emese Zsarnoczay, Daniel Pinos, Milan Vecsey-Nagy, Saikiran Rapaka, Puneet Sharma, Jim O’doherty, Jens Ricke, et al.

    This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists’ efficiency in clinical practice.


  • Open Access

    Radiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data

    by Nicola Fink, Emese Zsarnoczay, U. Joseph Schoepf, Jim O’doherty, Joseph P. Griffith, Daniel Pinos, Christian Tesche, Jens Ricke, Martin J. Willemink, Akos Varga-Szemes, et al.

    Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.