Chronic Apical and Nonapical Right Ventricular Pacing in Patients with High-Grade Atrioventricular Block: Results of the Right Pace Study
Open Access
- 22 May 2018
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-7
Abstract
Objective. The aim of the study was to compare the two approaches to chronic right ventricular pacing currently adopted in clinical practice: right ventricular apical (RVA) and non-RVA pacing. Background. Chronic RVA pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. Non-RVA pacing may yield more physiologic ventricular activation and provide potential long-term benefits and has recently been adopted as standard procedure at many implanting centers. Methods. The Right Pace study was a multicenter, prospective, single-blind, nonrandomized trial involving 437 patients indicated for dual-chamber pacemaker implantation with a high percentage of RV pacing. Results. RV lead-tip target location was the apex or the interventricular septum. RVA (274) and non-RVA patients (163) did not differ in baseline characteristics. During a median follow-up of 19 months (25th–75th percentiles, 13–25), 17 patients died. The rates of the primary outcome of death due to any cause or hospitalization for heart failure were comparable between the groups (log-rank test, ), as were the rates of the composite of death due to any cause, hospitalization for heart failure, or an increase in left ventricular end-systolic volume ≥ 15% as compared with the baseline evaluation (secondary outcome, ). After central adjudication of X-rays, comparison between adjudicated RVA (239 patients) and non-RVA (170 patients) confirmed the absence of difference in the rates of primary () and secondary () outcome. Conclusions. In patients with indications for dual-chamber pacemaker who require a high percentage of ventricular stimulation, RVA or non-RVA pacing resulted in comparable outcomes. This study is registered with ClinicalTrials.gov (identifier: NCT01647490).
Keywords
This publication has 18 references indexed in Scilit:
- Is there a right place to pace the right ventricle? Evaluation of apical and septal positions in a pacemaker population: Study protocol for a prospective intervention-control trialContemporary Clinical Trials, 2014
- Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association surveyEP Europace, 2013
- A Randomized Study of Defibrillator Lead Implantations in the Right Ventricular Mid‐Septum versus the Apex: The SEPTAL StudyτJournal of Cardiovascular Electrophysiology, 2012
- Pacing the right ventricular outflow tract septum: time to embrace the futureEP Europace, 2011
- Beneficial effects of right ventricular non-apical vs. apical pacing: a systematic review and meta-analysis of randomized-controlled trialsEP Europace, 2011
- Intramural Dyssynchrony from Acute Right Ventricular Apical Pacing in Human Subjects with Normal Left Ventricular FunctionJournal of Cardiovascular Translational Research, 2010
- Acute Effects of Right Ventricular Apical Pacing on Left Ventricular Synchrony and MechanicsCirculation: Arrhythmia and Electrophysiology, 2009
- Effects of Right Ventricular Pacing on Intra-Left Ventricular Electromechanical Activation in Patients With Native Narrow QRSThe American Journal of Cardiology, 2006
- Selective Site Pacing:Pacing and Clinical Electrophysiology, 2004
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003